Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.
FCC ID: 2BSRQ-LM-018 External Photos of the EUT FCC ID: 2BSRQ-LM-018
Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BSRQ-LM-018
FCC ID: 2BSRQ-LM-018 Internal Photos of the EUT FCC ID: 2BSRQ-LM-018 FCC ID: 2BSRQ-LM-018 FCC ID: 2BSRQ-LM-018 ANT
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. .................... : FCC ID. ........................................... : CTA25093000102 2BSRQ-LM-018 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Oct. 10, 2025 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ........................................... : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ........................... : Shenzhen LM Technology Co., Ltd. Address ........................................... : A532, Nanfeng Building, Nanshan Yungu Innovation Industrial Park, Liuxian Avenue No. 4093, Nanshan, Shenzhen, Guangdong, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Electronic bobblehead figure Trade Mark ........................................ N/A Manufacturer .................................... : Dongguan Zhuoshun Electronic Co., Ltd. Model/Type reference ...................... : LM-018 Listed Models ................................... : N/A Rating ............................................... : DC 3.7V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA25093000102 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Electronic bobblehead figure Model /Type : LM-018 Listed Models : N/A Applicant : Shenzhen LM Technology Co., Ltd. Address : A532, Nanfeng Building, Nanshan Yungu Innovation Industrial Park, Liuxian Avenue No. 4093, Nanshan, Shenzhen, Guangdong, China Manufacturer : Dongguan Zhuoshun Electronic Co., Ltd. Address : Room 202, Building 2, Datan Road No.2, Guxia, Shipai Town, Dongguan, Guangdong, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25093000102 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 Conducted Power Results ....................................................................................... 7 4.3 Manufacturing tolerance .......................................................................................... 7 4.4 Evaluation Result ..................................................................................................... 8 4.5 Simultaneous Transmission for SAR Exclusion ...................................................... 8 5 Conclusion ........................................................................................................................... 8 Report No.: CTA25093000102 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] …
Text truncated - open the document above for the full version.
1. Antenna Description: Antenna type PCB antenna Model LM-018 Frequency range 2400-2500MHz Manufacturer Shenzhen LM Technology Co., Ltd. Address A532, Nanfeng Building, Nanshan Yungu Innovation Industrial Park, Liuxian Avenue No. 4093, Nanshan, Shenzhen, Guangdong, China ANT Peak Gain 0.78 dBi 2. Antenna Photo: Length :6.82mm Width:4.12mm 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. .................... : FCC ID. ........................................... : CTA25093000101 2BSRQ-LM-018 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Oct. 10, 2025 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ........................... : Shenzhen LM Technology Co., Ltd. Address ............................................ : A532, Nanfeng Building, Nanshan Yungu Innovation Industrial Park, Liuxian Avenue No. 4093, Nanshan, Shenzhen, Guangdong, China Test specification ........................... : Standard ........................................... : FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Electronic bobblehead figure Trade Mark ....................................... : N/A Manufacturer .................................... : Dongguan Zhuoshun Electronic Co., Ltd. Model/Type reference ...................... : LM-018 Listed Models ................................... : N/A Modulation ....................................... : GFSK, Π/4DQPSK Frequency ......................................... From 2402MHz to 2480MHz Ratings ............................................. : DC 3.7V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA25093000101 Page 2 of 37 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Electronic bobblehead figure Model /Type : LM-018 Listed Models : N/A Applicant : Shenzhen LM Technology Co., Ltd. Address : A532, Nanfeng Building, Nanshan Yungu Innovation Industrial Park, Liuxian Avenue No. 4093, Nanshan, Shenzhen, Guangdong, China Manufacturer : Dongguan Zhuoshun Electronic Co., Ltd. Address : Room 202, Building 2, Datan Road No.2, Guxia, Shipai Town, Dongguan, Guangdong, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25093000101 Page 3 of 37 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS .......................................................................................................................................... 4 2 SUMMARY ........................................................................................................................................................ 5 2.1 General Remarks .................................................................................................................................... 5 2.2 Product Description ................................................................................................................................. 5 2.3 Equipment Under Test ............................................................................................................................ 5 2.4 Short description of the Equipment under Test (EUT) ............................................................................ 5 2.5 EUT configuration .................................................................................................................................... 6 2.6 EUT operation mode ............................................................................................................................... 6 2.7 Block Diagram of Test Setup .................................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) .............................................................................................................. 6 2.9 Modifications ........................................................................................................................................... 6 3 TEST ENVIRONMENT ...................................................................................................................................... 7 3.1 Address of the test laboratory ................................................................................................................. 7 3.2 Test Facility ............................................................................................................................................. 7 3.3 Environmental conditions .............…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BT FCC ID : 2BSRQ-LM-018 Company : Shenzhen LM Technology Co., Ltd. EUT : Electronic bobblehead figure Model Number : LM-018 Report No. : CTA25093000101 Reviewed By : Eric Wang 2 Appendix A: 20dB Emission Bandwidth Test Result TestMode Antenna Freq(MHz) 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.954 2401.547 2402.501 --- --- 2441 0.936 2440.550 2441.486 --- --- 2480 0.948 2479.550 2480.498 --- --- 2DH5 Ant1 2402 1.305 2401.358 2402.663 --- --- 2441 1.278 2440.379 2441.657 --- --- 2480 1.275 2479.382 2480.657 --- --- 3 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 4 2DH5_Ant1_2402 2DH5_Ant1_2441 5 2DH5_Ant1_2480 6 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 0.88542 2401.5670 2402.4525 --- --- 2441 0.87033 2440.5710 2441.4414 --- --- 2480 0.87028 2479.5743 2480.4446 --- --- 2DH5 Ant1 2402 1.1910 2401.4151 2402.6061 --- --- 2441 1.1843 2440.4168 2441.6011 --- --- 2480 1.1867 2479.4162 2480.6029 --- --- 7 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 8 2DH5_Ant1_2402 2DH5_Ant1_2441 9 2DH5_Ant1_2480 10 Appendix C: Maximum conducted output power Test Result Peak Test Mode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict DH5 Ant1 2402 -0.17 ≤20.97 PASS 2441 -0.36 ≤20.97 PASS 2480 -0.45 ≤20.97 PASS 2DH5 Ant1 2402 -0.98 ≤20.97 PASS 2441 -1.15 ≤20.97 PASS 2480 -1.26 ≤20.97 PASS 11 Appendix D: Carrier frequency separation Test Result TestMode Antenna Freq(MHz) Result[MHz] Limit[MHz] Verdict DH5 Ant1 Hop 1.008 ≥0.954 PASS 2DH5 Ant1 Hop 1.148 ≥0.870 PASS 12 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 13 Appendix E: Time of occupancy Test Result TestMode Antenna Freq(MHz) BurstWidth [ms] TotalHops [Num] Result[s] Limit[s] Verdict DH1 Ant1 Hop 0.400 315 0.126 ≤0.4 PASS DH3 Ant1 Hop 1.650 160 0.264 ≤0.4 PASS DH5 Ant1 Hop 2.900 109 0.316 ≤0.4 PASS 2DH1 Ant1 Hop 0.400 312 0.125 ≤0.4 PASS 2DH3 Ant1 Hop 1.650 162 0.267 ≤0.4 PASS 2DH5 Ant1 Hop 2.900 112 0.325 ≤0.4 PASS 14 Test Graphs DH1_Ant1_Hop DH3_Ant1_Hop 15 DH5_Ant1_Hop 16 2DH1_Ant1_Hop 2DH3_Ant1_Hop 17 2DH5_Ant1_Hop 18 19 Appendix F: Number of hopping channels Test Result TestMode Antenna Freq(MHz) Result[Num] Limit[Num] Verdict DH5 Ant1 Hop 79 ≥15 PASS 2DH5 Ant1 Hop 79 ≥15 PASS 20 Test Graphs DH5_Ant1_Hop 2DH5_Ant1_Hop 21 Appendix G: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 Low 2402 -0.87 -51.83 ≤-20.87 PASS High 2480 -0.47 -62.68 ≤-20.47 PASS Low Hop_2402 -0.93 -59.97 ≤-20.93 PASS High Hop_2480 -0.90 -64.13 ≤-20.9 PASS 2DH5 Ant1 Low 2402 -3.66 -56.15 ≤-23.66 PASS High 2480 -6.43 -63.84 ≤-26.43 PASS Low Hop_2402 -4.33 -60.61 ≤-24.33 PASS High Hop_2480 -6.28 -63.54 ≤-26.28 PASS 22 Test Graphs DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 23 DH5_Ant1_High_Hop_2480 2DH5_Ant1_Low_2402 24 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 2DH5_Ant1_High_Hop_2480 25 26 Appendix H: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict DH5 Ant1 2402 Reference -1.19 -1.19 --- PASS 30~1000 -1.19 -67.14 ≤-21.19 PASS 1000~26500 -1.19 -43.73 ≤-21.19 PASS 2441 Reference -1.61 -1.61 --- PASS 30~1000 -1.61 -68.18 ≤-21.61 PASS 1000~26500 -1.61 -45.2 ≤-21.61 PASS 2480 Reference -0.90 -0.90 --- PASS 30~1000 -0.90 -68.18 ≤-20.9 PASS 1000~26500 -0.90 -42.99 ≤-20.9 PASS 2DH5 Ant1 2402 Reference -4.93 -4.93 --- PASS 30~1000 -4.93 -59.2 ≤-24.93 PASS 1000~26500 -4.93 -50.19 ≤-24.93 PASS 2441 Reference -5.21 -5.21 --- PASS 30~1000 -5.21 -66.9 ≤-25.21 PASS 1000~26500 -5.21 -50.93 ≤-25.21 PASS 2480 Reference -5.25 -5.25 --- PASS 30~1000 -5.25 -67.65 ≤-25.25 PASS 1000~26500 -5.25 -50.86 ≤-25.25 PASS 27 Test Graphs DH5_Ant1_2402_0~Reference DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 28 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 29 DH5_Ant1_2441_1000~26500 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 30 DH5_Ant1_2480_1000~26500 2DH5_Ant1_2402_0~Reference 31 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 2DH5_Ant1_2441_0~Reference 32 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 33 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 34 35 Appendix I: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] DC [%] xFactor Limit Verdict DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.91 3.75 77.60 1.10 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 2DH5 Ant1 2402 2.91 3.75 77.60 1.10 --- --- 2441 2.92 3.75 77.87 1.09 --- --- 2480 2.91 3.75 77.60 1.10 --- --- 36 Test Graphs DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 37 2DH5_Ant1_2402 2DH5_Ant1_2441 38 2DH5_Ant1_2480
FCC ID: 2BSRQ-LM-018 Test Setup Photos of the EUT FCC ID: 2BSRQ-LM-018
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.00 mW |