ElectricalFireplaceStovewithHeater OWNER’SMANUAL ModelNo.FP201RW PLEASESAVETHESEINSTRUCTIONS WARNING:READTHISOWNER’SMANUALCAREFULLYBEFOREUSE. ThankyouforchoosingourElectricFireplace.Thisowner’smanualwillprovideyouwithvaluable informationnecessaryforthepropercareandmaintenanceofyournewproduct.Pleasetakeafew momentstothoroughlyreadtheinstructionsandfamiliarizeyourselfwithalltheoperationalaspectsof yournewheater. 2 IMPORTANTINSTRUCTIONS Whenusingthiselectricunit,basicsafetyprecautionsshouldalwaysbefollowedtoreducetheriskof fire,electricshock,andinjurytopersons,includingthefollowing: 1.ReadALLinstructionsbeforeusingthisunit. 2.CAUTION:RiskofElectricShock.DONOTopenortrytorepairtheheateryourself. 3.Thisheatermaygethotwheninuse.Toavoidburns,DONOTletbareskintouchhotsurfaces. 4.Keepcombustiblematerials,suchasfurniture,pillows,bedding,paper,clothes,andcurtainsatleast3 ftfromthefrontoftheheaterandkeepthemawayfromthesides,top,andrear.DONOTplace towelsorotherobjectsontheheater. 5.Extremecautionisnecessarywhenanyheaterisusedbyornearchildrenorthedisabled,orwhenthe heaterisleftoperatingandunattended. 6.DONOToperateanyheaterwithadamagedcordoraftertheheatermalfunctions,hasbeendropped ordamagedinanymanner.Returnheatertoauthorizedservicefacilityforexamination,electricalor mechanicaladjustment,orrepair. 7.Thisheaterisnotintendedforuseinbathrooms,laundryareasandsimilarindoorlocations.NEVER locateheaterwhereitmayfallintoabathtuborotherwatercontainer.Toprotectagainstelectrical hazards,DONOTimmerseinwaterorotherliquids. 8.DONOTtouchthecontrolpanelorplugwithawethand. 9.DONOTruncordundercarpeting.DONOTcovercordwiththrowrugs,runners,orsimilar coverings.Arrangecordawayfromtrafficareaandwhereitwillnotbetrippedover. 10.DONOTinsertorallowforeignobjectstoenteranyventilationorexhaustopeningasthismay causeanelectricshockorfire,ordamagetheheater. 11.Topreventapossiblefire,DONOTblocktheairintakesorexhaustinanymanner.DONOTuseon softsurfaces,likeabed,whereopeningsmaybecomeblocked. 12.Aheaterhashotandarcingorsparkingpartsinside.DONOTuseinareaswheregasoline,paint, explosiveand/orflammableliquidsareusedorstored.Keepunitawayfromheatedsurfacesand openflames. 13.Alwaysplugheatersdirectlyintoawalloutlet/receptacleNeverusewithanextensioncordor relocatablepowertap(outlet/powerstrip) 14.Toavoidfireorshockhazard,plugtheunitdirectlyintoa120VACelectricaloutlet. 15.Todisconnectheater,turncontrolstoOFF,thenremoveplugfromoutlet.Pullfirmlyontheplug, DONOTunplugbypullingonthecord. 16.Alwaysunplugtheunitbeforemovingorcleaning,orwhenevertheheaterisnotinuse. 17.Useonlyforintendedhouseholduseasdescribedinthismanual.Anyotherusenotrecommended bythemanufacturermaycausefire,electricshock,orinjurytopersons.Theuseofattachmentsnot recommendedorsoldbyunauthorizeddealersmaycausehazards. 18.Alwaysuseonadry,levelsurface.Useonflooronly. 19.DONOTuseoutdoors. 20.WARNING:Toreducetheriskoffireorelectricshock,DONOTusethisunitwithanysolid-state speedcontroldevice. 21.DONOTattempttorepairoradjustanyelectricalormechanicalfunctionsonthisunit.Doingso willvoidyourwarranty.Theinsideoftheunitcontainsnouserserviceableparts.Qualified personnelshouldperformallservicingonly. 3 SAVETHESEINSTRUCTIONS SPECIFICATIONS VoltageRating120V(60Hz) PowerConsumption1500W UnitSize20.5in.(W)x8.7in.(D)x12.2in.(H) UnitWeight5.5KG SAFETYFEATURES OverheatSafetyFeature Thisheaterisequippedwithaoverheatsafetyfeature.Whentheheater’sinternalcomponentsreacha certaintemperaturethatcouldcauseoverheatorpossiblefire,theheaterwillautomaticallyshutoff. WARNING:Itisnormalforthepowercordtofeelwarmtothetouch;however,aloosefitbetweenthe outletandtheplugmaycauseoverheatingoftheplug.Ifthisoccurs,tryinsertingtheplugintoa differentoutlet.Contactaqualifiedelectriciantoinspecttheoriginaloutletfordamage. INTHEBOX Electricalfireplacestovewithheater Remotecontrol(withbatteries) Instructionmanual 4 PRODUCTDIAGRAM Artificialcharcoalset Controlpanel Powerswitch Receivercover Airoutlet 5 ControlPanel Powerbutton:Powerstheheateronandoff. Timerbutton:Usersettingtimingbootor shutdown Timerlight:Indicatethetimermode Heaterbutton:Setuptheheatmodeand turnofftheheat. Flamebutton:Setthebrightnessofthe flame 6 PREPARATION Placetheheateronafirm,levelsurfaceandplugintoa120V60Hzpoweroutlet. Caution:Therearoftheheatershouldbeatleast4inchawayfromthewall. AUTOMATICCUT-OFF Acut-offswitchisfittedtotheheatingelementtopreventdamageduetooverheating.Ifitcuts-offdue toanobstructionintheairflow,theheatermustbeallowedtocoolfor5minutesandtheobstruction mustberemovedbeforerestarting. OPERATINGINSTRUCTIONS 1.FirstturnonthePowerswitchontherightsideoftheheater.ThePowerswitchsuppliespowertoallthe functionofthefireplace.Thisswitchmustbein“I”positionforanyfunctionsincludingtheremotecontrol towork. Remotecontrol 7 PressthePowerbuttonontheremotecontrol,theheatandflame effectwillbeon.PressthePowerbuttonagain,heatandflame effectwillbeoffimmediately(butthefanwillprolongworkingfor 30seconds),andthentheheatergoesintoastandbymode. 2.Settingtimer-power-off Caution!ONLYunderpower-onmodecanyousettimer-power-offfunction. Or Whentheunitispoweron,presstheTimerbuttontosettimer- power-offfunction(throughcontrolpanelorremotecontrol). 0 Underpower-on,thetimerlightdemonstratesthetimer-power- offmode.PresstheTimerbuttonmorethanonce,thetimevalue willvarythroughthepath0-1h-2h-4h-8h-0incirculation. Thecorrespondinglightisonwhentimer–power-offisset. 2.Settingtimer-power-on Caution!ONLYunderstandbymodecanyousettimer-power-onfunction. Or Understandbymode,presstheTimerbuttontosettimer- power-onfunction(throughcontrolpanelorremote control). 0 Understandby,timerlightdemonstratesthetimer-power- onmode.PresstheTimerbuttonmorethanonce,the timevaluewillvarythroughthepath0-1h-2h-4h-8h-0in circulation. Thecorrespondinglightisonwhentimer–power-onis set. 8 3.Settingheat Understandbymode,pressHeaterbuttontostartheater. Or Understandbymode,presstheHeaterbuttononthecontrolpanel orremotecontrol,theheaterwillstart(Theheaterindicatoris undertheartificialcharcoalset.Whenheatison,thecharcoalset wi…
Text truncated - open the document above for the full version.
Page1of10FCCID:2BSTA-201RReportNo.:LCSC08036023EC TRF-4-E-214A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation For NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. ElectricStove TestModel:FP201R Preparedfor:NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. Address:No.228,Xinxing4thRoad,CixiHigh-techIndustrialDevelopmentZone, Cixi,P.R.C Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:August03,2026 Numberoftestedsamples:2 SampleNo.:C260803004-1,C260803004-2 Serialnumber:Prototype DateofTest:August03,2026~August25,2026 DateofReport:August26,2026 Page2of10FCCID:2BSTA-201RReportNo.:LCSC08036023EC TRF-4-E-214A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation ReportReferenceNo......................:LCSC08036023EC DateofIssue.......................................:August26,2026 TestingLaboratoryName..............:GuangzhouLCSComplianceTestingLaboratoryLtd. Address................................................:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure.............:FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. Address................................................:No.228,Xinxing4thRoad,CixiHigh-techIndustrialDevelopmentZone, Cixi,P.R.C TestSpecification Standard..............................................:FCCKDBpublication447498D01GeneralRFExposureGuidancev06 FCCCFR47part11.1310 FCCCFR47part22.1091 TRFOriginator....................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheGuangzhou LCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthematerial. GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnotassumeliabilityfor damagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. TestItemDescription......................:ElectricStove TradeMark..........................................:N/A TestModel...........................................:FP201R Ratings.................................................:PleaseRefertoPage6 Result..................................................:Pass Compiledby:Supervisedby:Approvedby: LifengLe/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page3of10FCCID:2BSTA-201RReportNo.:LCSC08036023EC TRF-4-E-214A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation TestModel...............................: FP201R EUT.........................................: ElectricStove Applicant...............................:NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. Address..................................:No.228,Xinxing4thRoad,CixiHigh-techIndustrialDevelopment Zone,Cixi,P.R.C Telephone...............................:/ Fax..........................................:/ Manufacturer........................:NingboDesaElectricalApplianceManufacturingCo.,Ltd. Address...................................:IntelligentHouseholdElectricalIndustrialPark,GuanhaiweiTown, Cixi,Zhejiang315315 Telephone...............................: Fax..........................................: Factory...................................:NingboDesaElectricalApplianceManufacturingCo.,Ltd. Address...................................:IntelligentHouseholdElectricalIndustrialPark,GuanhaiweiTown, Cixi,Zhejiang315315 Telephone...............................:/ Fax..........................................:/ TestResultPass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC08036023EC August26,2026 Dateofissue Page4of10FCCID:2BSTA-201RReportNo.:LCSC08036023EC TRF-4-E-214A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000August26,2026InitialIssue--- Page5of10FCCID:2BSTA-201RReportNo.:LCSC08036023EC TRF-4-E-214A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.ProductInformation.........................................................................................................................................6 2.EvaluationMethod............................................................................................................................................7 3.Limit......................................................................................................................................................................7 4.MPECalculationMethod................................................................................................................................7 5.AntennaInformation......…
Text truncated - open the document above for the full version.
Page1of2FCCID:2BSTA-201R GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 Page2of2FCCID:2BSTA-201R GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3 TestSetupPhoto(s)ofRFConductedMeasurement Fig.4
Page1of35FCCID:2BSTA-201RReportNo.:LCSC08036023EA TRF-4-E-145A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT For NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. ElectricStove TestModel:FP201R Preparedfor:NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. Address:No.228,Xinxing4thRoad,CixiHigh-techIndustrialDevelopment Zone,Cixi,P.R.C Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:August03,2026 Numberoftestedsamples:2 SampleNo.:C260803004-1,C260803004-2 Serialnumber:Prototype DateofTest:August03,2026~August25,2026 DateofReport:August26,2026 Page2of35FCCID:2BSTA-201RReportNo.:LCSC08036023EA TRF-4-E-145A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSC08036023EA DateofIssue.......................................:August26,2026 TestingLaboratoryName..............:GuangzhouLCSComplianceTestingLaboratoryLtd. Address................................................:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. Address................................................:No.228,Xinxing4thRoad,CixiHigh-techIndustrialDevelopment Zone,Cixi,P.R.C TestSpecification Standard..............................................: FCCCFR47PART15C(15.247) TRFOriginator....................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:ElectricStove TradeMark..........................................:N/A TestModel...........................................:FP201R Ratings.................................................:PleaseRefertoPage6 Result...................................................:Pass Compiledby:Supervisedby:Approvedby: LifengLe/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page3of35FCCID:2BSTA-201RReportNo.:LCSC08036023EA TRF-4-E-145A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCC--TESTREPORT TestModel..........................:FP201R EUT....................................:ElectricStove Applicant...........................:NINGBOKONWINELECTRICALAPPLIANCECO.,LTD. Address..............................:No.228,Xinxing4thRoad,CixiHigh-techIndustrial DevelopmentZone,Cixi,P.R.C Telephone..........................:/ Fax.....................................:/ Manufacturer.....................:NingboDesaElectricalApplianceManufacturingCo., Ltd. Address..............................:IntelligentHouseholdElectricalIndustrialPark,Guanhaiwei Town,Cixi,Zhejiang315315 Telephone..........................: Fax.....................................: Factory..............................:NingboDesaElectricalApplianceManufacturingCo., Ltd. Address..............................:IntelligentHouseholdElectricalIndustrialPark,Guanhaiwei Town,Cixi,Zhejiang315315 Telephone..........................:/ Fax.....................................:/ TestResultPass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC08036023EA August26,2026 Dateofissue Page4of35FCCID:2BSTA-201RReportNo.:LCSC08036023EA TRF-4-E-145A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000August26,2026InitialIssue--- Page5of35FCCID:2BSTA-201RReportNo.:LCSC08036023EA TRF-4-E-145A/0 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT).........................................................................................................................6 1.2.SUPPORTEQUIPMENTLIST..................................................................................................................................7 1.3.EXTERNALI/OCABLE..........................................................................................................................................7 1.4.DESCRIPTIONOFTESTFACILITY.........................................................................................................................7 1.5.STATEMENTOFTHEMEASUREMENTUNCERTAINTY…
Text truncated - open the document above for the full version.
Page 1 of 36 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB TRF-4-E-147 A/0 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For NINGBO KONWIN ELECTRICAL APPLIANCE CO.,LTD. Electric Stove Test Model: FP201R Prepared for : NINGBO KONWIN ELECTRICAL APPLIANCE CO.,LTD. Address : No. 228, Xinxing 4th Road, Cixi High-tech Industrial Development Zone, Cixi, P.R.C Prepared by : Guangzhou LCS Compliance Testing Laboratory Ltd. Address : No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel : (+86) 020-39166689 Fax : (+86) 020-39166619 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : August 03, 2026 Number of tested samples : 2 Sample No. : C260803004-1, C260803004-2 Serial number : Prototype Date of Test : August 03, 2026 ~ August 25, 2026 Date of Report : August 26, 2026 Page 2 of 36 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB TRF-4-E-147 A/0 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSC08036023EB Date of Issue ................................... : August 26, 2026 Testing Laboratory Name ............ : Guangzhou LCS Compliance Testing Laboratory Ltd. Address ........................................... : No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : NINGBO KONWIN ELECTRICAL APPLIANCE CO.,LTD. Address ........................................... : No. 228, Xinxing 4th Road, Cixi High-tech Industrial Development Zone, Cixi, P.R.C Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) TRF Originator ................................ : Guangzhou LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Guangzhou LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Guangzhou LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Guangzhou LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Electric Stove Trade Mark ..................................... : N/A Test Model ...................................... : FP201R Ratings ............................................ : Please Refer to Page 6 Result ........................................... : Pass Compiled by: Supervised by: Approved by: Lifeng Le/ Administrators Justin Zhu/ Technique Director Gavin Liang/ Manager Page 3 of 36 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB TRF-4-E-147 A/0 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Model............................... : FP201R EUT......................................... : Electric Stove Applicant............................... : NINGBO KONWIN ELECTRICAL APPLIANCE CO.,LTD. Address.................................. : No. 228, Xinxing 4th Road, Cixi High-tech Industrial Development Zone, Cixi, P.R.C Telephone............................... : / Fax.......................................... : / Manufacturer........................ : Ningbo Desa Electrical Appliance Manufacturing Co., Ltd. Address................................... : Intelligent Household Electrical Industrial Park, Guanhaiwei Town, Cixi, Zhejiang 315315 Telephone............................... : Fax.......................................... : Factory................................... : Ningbo Desa Electrical Appliance Manufacturing Co., Ltd. Address................................... : Intelligent Household Electrical Industrial Park, Guanhaiwei Town, Cixi, Zhejiang 315315 Telephone............................... : / Fax.......................................... : / Test Result Pass The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSC08036023EB August 26, 2026 Date of issue Page 4 of 36 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB TRF-4-E-147 A/0 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 August 26, 2026 Initial Issue -- Page 5 of 36 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB TRF-4-E-147 A/0 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 6 1.1. DESCRIPTION OF DEVICE (EUT) ................…
Text truncated - open the document above for the full version.
Page 31 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11N20SISO_Ant1_2437_1000~26500 11N20SISO_Ant1_2462_0~Reference Page 32 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11N20SISO_Ant1_2462_30~1000 11N20SISO_Ant1_2462_1000~26500 Page 33 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Page 34 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com B.6 Duty Cycle Test Result TestMode Antenna Frequency [MHz] Transmission Duration [ms] Transmission Period [ms] Duty Cycle [%] xFactor 11B Ant1 2412 12.42 12.54 99.04 0.04 2437 12.41 12.54 98.96 0.05 2462 12.41 12.55 98.88 0.05 11G Ant1 2412 2.06 2.19 94.06 0.27 2437 2.07 2.20 94.09 0.26 2462 2.07 2.20 94.09 0.26 11N20SISO Ant1 2412 1.92 2.05 93.66 0.28 2437 1.92 2.05 93.66 0.28 2462 1.92 2.05 93.66 0.28 Page 35 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Page 36 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11G_Ant1_2412 11G_Ant1_2437 Page 37 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11G_Ant1_2462 11N20SISO_Ant1_2412 Page 38 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Page 39 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Page 40 of 47 FCC ID: 2BSTA-201R Report No.: LCSC08036023EB Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com B.7 Emissions in Restricted Bands Test Result TestMode Antenna ChName Frequency [MHz] Detector Freq [MHz] Result [dBm] Limit [dBm] Gain [dBi] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict 11B Ant1 Low 2412 AV 2310.000 -47.33 ≤-43.78 2.54 0.04 50.45 ≤54 PASS AV 2374.620 -44.27 ≤-43.78 2.54 0.04 53.51 ≤54 PASS AV 2390.000 -45.28 ≤-43.78 2.54 0.04 52.50 ≤54 PASS Peak 2310.000 -40.75 ≤-23.74 2.54 0.00 56.99 ≤74 PASS Peak 2386.580 -35.78 ≤-23.74 2.54 0.00 61.96 ≤74 PASS Peak 2390.000 -40.85 ≤-23.74 2.54 0.00 56.89 ≤74 PASS High 2462 AV 2483.500 -47.01 ≤-43.79 2.54 0.05 50.78 ≤54 PASS AV 2488.510 -44 ≤-43.79 2.54 0.05 53.79 ≤54 PASS AV 2500.000 -45.57 ≤-43.79 2.54 0.05 52.22 ≤54 PASS Peak 2483.500 -40.08 ≤-23.74 2.54 0.00 57.66 ≤74 PASS Peak 2497.860 -37.18 ≤-23.74 2.54 0.00 60.56 ≤74 PASS Peak 2500.000 -42.73 ≤-23.74 2.54 0.00 55.01 ≤74 PASS 11G Ant1 Low 2412 AV 2310.000 -47.69 ≤-44.01 2.54 0.27 50.32 ≤54 PASS AV 2388.920 -45.36 ≤-44.01 2.54 0.27 52.65 ≤54 PASS AV 2390.000 -45.98 ≤-44.01 2.54 0.27 52.03 ≤54 PASS Peak 2310.000 -39.4 ≤-23.74 2.54 0.00 58.34 ≤74 PASS Peak 2389.310 -33.8 ≤-23.74 2.54 0.00 63.94 ≤74 PASS Peak 2390.000 -34.39 ≤-23.74 2.54 0.00 63.35 ≤74 PASS High 2462 AV 2483.500 -46.66 ≤-44.00 2.54 0.26 51.34 ≤54 PASS AV 2493.350 -46 ≤-44.00 2.54 0.26 52.00 ≤54 PASS AV 2500.000 -46.81 ≤-44.00 2.54 0.26 51.19 ≤54 PASS Peak 2483.500 -38.58 ≤-23.74 2.54 0.00 59.16 ≤74 PASS Peak 2485.430 -35.4 ≤-23.74 2.54 0.00 62.34 ≤74 PASS Peak 2500.000 -36.8 ≤-23.74 2.54 0.00 60.94 ≤74 PASS 11N20SISO Ant1 Low 2412 AV 2310.000 -47.93 ≤-44.02 2.54 0.28 50.09 ≤54 PASS AV 2389.310 -46.1 ≤-44.02 2.54 0.28 51.92 ≤54 PASS AV 2390.000 -46.26 ≤-44.02 2.54 0.28 51.76 ≤54 PASS Peak 2310.000 -39.09 ≤-23.74 2.54 0.00 58.65 ≤74 PASS Peak 2389.440 -34.81 ≤-23.74 2.54 0.00 62.93 ≤74 PASS Peak 2390.000 -36.99 ≤-23.74 2.54 0.00 60.75 ≤74 PASS High 2462 AV 2483.500 -46.94 ≤-44.02 2.54 0.28 51.08 ≤54 PASS AV 2484.000 -45…
Text truncated - open the document above for the full version.
1408 Pinon Place Fullerton, · California, 92835 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.20 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 29.40 mW |