FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Boxing Electronic Co.,Ltd./
  3. 2BSU5-TRX-DT2-BLU

2BSU5-TRX-DT2-BLUTrax Dot 2

Shenzhen Boxing Electronic Co.,Ltd.
Trax Dot 2 - FCC ID 2BSU5-TRX-DT2-BLU - Shenzhen Boxing Electronic Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 02, 2025
Application Purpose
Original Equipment
Equipment Note
Trax Dot 2
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Boxing Electronic Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TraxDot2UserManual ProductOverview ProductName:TraxDot2 ModelNumber:TRX-DT2-BLU Productphoto: AppearanceandComponents 1.PowerButton:Forturningon/offandtriggeringfunctions 2.Horn:Emitsalertsounds 3.IndicatorLight:Showsoperationalstatus ElectricalParameters 1.PowerSource:User-replaceableCR2032coincellbattery 2.BatteryLife:Approximately6months(dependingonusage) 3.AlertType:Buzzer 4.PowerOn/OffMethod:Longpressthebutton CompatibleSystems ThelatestversionofiOS,iPadOS,ormacOSisrecommendedforusewiththe AppleFindMyapp. InstructionsforUse 1.PowerOn/Off •PowerOn:Brieflypressthefunctionbuttononce.Thehornwillbeeponce andtheindicatorlightwillturnon,signalingthedeviceispoweredon. •PowerOff:Pressandholdthefunctionbuttonfor3–5seconds.Release afterhearingbeepsconfirmingsuccessfulpoweroff. 2.ConnectingtotheFindMyApp 1.OpentheFindMyapponyouriPhoneoriPad. 2.Allownotificationsfromtheapp. 3.PoweronyourTraxDot2. 4.IntheFindMyapp,selectthe"Items"tab→Tap"AddItem"→Tap"Other SupportedItems". 5.OnceyourTraxDot2islocated,tap"Connect". 6.ChoosearecognizablenameandemojiforyourTraxDot2andtap “Continue”. 7.ConfirmaddingyourTraxDot2toyourAppleIDandcompletethesetup. 3.FindingaNearbyItem IntheFindMyapp,taponthecorrespondingitemandselect"PlaySound". YourTraxDot2willemitabeepingsound. Tap"StopSound"onceyoufindyouritem. 4.ViewingLastKnownLocation IntheFindMyapp,tapontheitem.Itslastknownlocationwillappearonthemap withthechosenemoji.Tap“Directions”toopentheMapsappfornavigation. 5.Enabling“NotifyWhenLeftBehind” Enablethe“NotifyWhenLeftBehind”toggleintheitem'ssettings.Youwillreceive anotificationifyouleaveyourTraxDot2behindanditisnolongerinrangeof yourdevice. 6.Enabling“NotifyWhenFound” Enablethe“NotifyWhenFound”toggle.Youwillreceiveanotificationwithan updatedlocationwhenyourTraxDot2isdetectedbyanotherFindMy-enabled device. Note:Thisfeaturecanonlybeactivatedwhenyouritemisoutofrange. 7.Enabling"LostMode" 1.Undertheitem'ssettings,tap"Enable"nexttoLostMode. 2.Enteraphonenumberoremailaddresswhereyoucanbereached,and optionally,amessageforthefinder. 3.Tap"Activate". Note: EnablingLostModeautomaticallyenables“NotifyWhenFound”. YourTraxDot2willbelockedandcannotbepairedtoanotherdevice. 8.RemovinganItemfromtheFindMyApp 1.Ensure"LostMode"isdisabled. 2.Scrolltothebottomoftheitem'sdetailsscreenintheFindMyappand tap"RemoveItem". 3.Confirmtheremoval. 9.FactoryReset 1.First,removetheitemfromtheFindMyapp(asdescribedabove). 2.Quicklypressthefunctionbuttonfourtimes,thenpressandholditafifth timeuntilyouheararingingchime.Thedeviceisnowresetandreadyto bepairedagain. BatteryReplacementInstructions Useasmallscrewdriverorcointoopenthebatterycompartmentcover. RemovetheoldbatteryandinsertanewCR2032coincellbattery(observe thecorrectpolarity). Closethecompartmentcover.Thedeviceisreadyforuseuponpowering on. ImportantNotes Pleaseuseacoincellbatterythatmeetsspecifications. Disposeofusedbatteriesaccordingtolocalregulations. ThisproducthasbeendesignedtoworkspecificallywithAppleFindMy technologyandcertifiedbytheproductmanufacturertomeetAppleFind Mynetworkproductspecificationsandrequirements.Appleisnot responsiblefortheoperationofthisdeviceoritscompliancewithsafety andregulatorystandards. Productsusedatadistanceoflessthan20cm: Thisdevicecomplieswithpart15oftheFCCRules.Operationissubject tothefollowingtwoconditions:  Thisdevicemaynotcauseharmfulinterference, thisdevicemustacceptanyinterferencereceived,including interferencethatmaycauseundesiredoperation. Anychangesormodificationsnotexpresslyapprovedbytheparty responsibleforcompliancecouldvoidtheuser'sauthoritytooperatethe equipment. NOTE: Thisequipmenthasbeentestedandfoundtocomplywiththelimitsfora ClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimits aredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgenerates,uses andcanradiateradiofrequencyenergyand,ifnotinstalledandusedin accordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewill notoccurinaparticularinstallation. Ifthisequipmentdoescauseharmfulinterferencetoradioortelevision reception, whichcanbedeterminedbyturningtheequipmentoffandon,theuser isencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures:  Reorientorrelocatethereceivingantenna.  Increasetheseparationbetweentheequipmentandreceiver.  Connecttheequipmentintoanoutletonacircuitdifferentfrom thattowhichthereceiverisconnected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement. Thedevicecanbeusedinportablexposureconditionwithoutrestriction. FCCID:2BSU5-TRX-DT2-BLU

Attestation Statements

Rev 1/26/2023 Shenzhen Boxing Electronic Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Nov. 26, 2025 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BSU5-TRX-DT2-BLU [Shenzhen Boxing Electronic Co.,Ltd.] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [Shenzhen Boxing Electronic Co.,Ltd.] certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name) Zhouchi Rev 1/26/2023 Shenzhen Boxing Electronic Co.,Ltd. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Nov. 26, 2025 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BSU5-TRX-DT2-BLU [Shenzhen Boxing Electronic Co.,Ltd.] certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Zhouchi

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:HOPEKCORPORATIONINC Address:16755CoyoteBushDrUnit84,SanDiego,CA92127UnitedStates FRN:0034562900 ContactName:PeterDavis TelephoneNo:561-235-6113 E-mail:[email protected] ThisletteristoconfirmthattheUSAgentforServiceofProcessacceptsresponsibilitytoactas alocalrepresentativeonbehalfofShenzhenBoxingElectronicCo.,Ltd. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. Applicant: CompanyName:ShenzhenBoxingElectronicCo.,Ltd. ProductDescription:TraxDot2 FRN:0037624061 GranteeCode:2BSU5 FCCID:2BSU5-TRX-DT2-BLU ContactName:Zhouchi Address:301and401Blk.5B,301Blk.5A,No.49,JiaoyuNorthRoad,PingdiStreet,Longgang District,ShenzhenCity TelephoneNo:13040853097 E-mail:[email protected] TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. ThisAgreementisvaliduntil(Permanentlyvalid). Date:2025/12/01 Applicant’sName: ShenzhenBoxingElectronicCo.,Ltd. USAgentforServiceofProcess’sName: HOPEKCORPORATIONINC Title:DeputyGeneralManagerTitle:Manager SignatureSignature

Cover Letter(s)

Shenzhen Boxing Electronic Co.,Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: November 27, 2025 Subject; Request for Confidentiality FCC ID: 2BSU5-TRX-DT2-BLU To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Zhouchi Title: Deputy General Manager

Cover Letter(s)

Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Shenzhen Boxing Electronic Co.,Ltd. Date: Nov. 26, 2025 Product Model Number: TRX-DT2-BLU FCC ID: 2BSU5-TRX-DT2-BLU To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following:  Testing  Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Contact Listed on FCC Wesbite Title: Deputy General Manager Email: [email protected] Telephone: 13040853097 On behalf of: Shenzhen Boxing Electronic Co.,Ltd.

Cover Letter(s)

Summary Inverted F Antenna Specification ITEM ANT SPEC Model Name PCB ANT Center Frequency Horizontal Vertical 2400MHz 2400MHz 2500MHz 2400MHz 2400MHz 2500MHz -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dBi Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 1Ohm Antenna Length 14.50mm Manufacture Shenzhen Boxing Electronic Co.,Ltd. Address 301 and 401 Blk.5B, 301 Blk.5A, No. 49, Jiaoyu North Road, Pingdi Street, Longgang District, Shenzhen City Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MH; 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs: Attestation of Global Compliance Co., Ltd.

External Photos

Ext Photos Model: TRX-DT2-BLU Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 Photo 6

Internal Photos

Int Photos Model: TRX-DT2-BLU Photo 1 Photo 2 Photo 3 Photo 4 Photo 5 ANT

RF Exposure Info

- Page 1 of 9 - Report No.: HB20251118052E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com RF EXPOSURE Test Report Product: Trax Dot 2 Trade Mark: woerxi Model Number: TRX-DT2-BLU FCC ID: 2BSU5-TRX-DT2-BLU Prepared for Shenzhen Boxing Electronic Co.,Ltd. 301 and 401 Blk.5B, 301 Blk.5A, No. 49, Jiaoyu North Road, Pingdi Street, Longgang District, Shenzhen City Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 9 - Report No.: HB20251118052E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ................................................................................................................................... 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 TEST FACILITIES AND ACCREDITATIONS ............................................................................................................ 6 2.1 TEST LABORATORY ..................................................................................................................................................... 6 2.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 6 2.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 6 2.4 TEST SOFTWARE ........................................................................................................................................................ 6 3 LIST OF TEST EQUIPMENT ................................................................................................................................ 7 4 RF EXPOSURE .................................................................................................................................................. 8 4.1 STANDALONE SAR TEST EXCLUSION CONSIDERATIONS........................................................................................................ 8 4.1.1. Limit ............................................................................................................................................................ 8 4.1.2. Test Procedures ........................................................................................................................................... 8 4.1.3. Test Result ................................................................................................................................................... 9 - Page 3 of 9 - Report No.: HB20251118052E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com TEST RESULT CERTIFICATION Applicant’s Name ................. : Shenzhen Boxing Electronic Co.,Ltd. Address ................................. : 301 and 401 Blk.5B, 301 Blk.5A, No. 49, Jiaoyu North Road, Pingdi Street, Longgang District, Shenzhen City Manufacturer's Name .......... : Shenzhen Boxing Electronic Co.,Ltd. Address ................................. : 301 and 401 Blk.5B, 301 Blk.5A, No. 49, Jiaoyu North Road, Pingdi Street, Longgang District, Shenzhen City Product description Product name ........................ : Trax Dot 2 Model Number ....................... : TRX-DT2-BLU Standards ............................. : FCC CFR 47 PART 1 , 1.1310 Test procedure ....................... : KDB 447498 D01 General RF Exposure Guidance v06 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report. Date of Test ............................................ : Date (s) of performance of tests ............. : Nov. 18, 2025~Nov. 26, 2025 Test Result ............................................... : Pass Testing Engineer : (Zoe Su) Technical Manager : ( G a r y Lu) Authorized Signatory : (L e o S u) - Page 4 of 9 - Report No.: HB20251118052E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Revision History Revised No. Date of Issue Description 01 Nov. 26, 2025 Original - Page 5 of 9 - Report No.: HB20251118052E-02 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com 1 General Description 1.1 Description …

Text truncated - open the document above for the full version.

Test Report

- Page 1 of 42 - Report No.: HB20251118052E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Test Report Product: Trax Dot 2 Trade Mark: woerxi Model Number: TRX-DT2-BLU FCC ID: 2BSU5-TRX-DT2-BLU Prepared for Shenzhen Boxing Electronic Co.,Ltd. 301 and 401 Blk.5B, 301 Blk.5A, No. 49, Jiaoyu North Road, Pingdi Street, Longgang District, Shenzhen City Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 42 - Report No.: HB20251118052E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION ................................................................................................................................... 6 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 6 1.2 TEST MODE .............................................................................................................................................................. 6 1.3 OPERATION CHANNEL LIST ........................................................................................................................................... 6 1.4 TEST SETUP .............................................................................................................................................................. 7 1.5 POWER SETTING CONFIGURATION PARAMETERS ............................................................................................................... 7 1.6 ANCILLARY EQUIPMENT .............................................................................................................................................. 7 2 SUMMARY OF TEST RESULT ............................................................................................................................. 8 3 TEST FACILITIES AND ACCREDITATIONS ............................................................................................................ 9 3.1 TEST LABORATORY ..................................................................................................................................................... 9 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 9 3.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 9 3.4 TEST SOFTWARE ...................................................................................................................................................... 10 4 LIST OF TEST EQUIPMENT .............................................................................................................................. 11 5 TEST ITEM AND RESULTS ............................................................................................................................... 13 5.1 ANTENNA REQUIREMENT .......................................................................................................................................... 13 5.1.1 Standard Requirement ............................................................................................................................. 13 5.1.2 Test Result ................................................................................................................................................. 13 5.2 CONDUCTED EMISSION ............................................................................................................................................. 14 5.2.1 Limits ........................................................................................................................................................ 14 5.2.2 Test Procedures ......................................................................................................................................... 14 5.2.3 Test Setup.................................................................................................................................................. 15 5.2.4 Test Result ................................................................................................................................................. 15 5.3 RADIATED EMISSION ................................................................................................................................................ 16 5.3.1 Limits ........................................................................................................................................................ 16 5.3.2 Test Procedures ......................................................................................................................................... 16 5.3.3 Test Setup.................................................................................................................................................. 16 5.3.4 Test Result ................................................................................................................................................. 17 5.3.5 Band Edge - Radiated ............................................................................................................................... 21 5.3.6 Spurious emission in restricted band 1000MHz-25000MHz ....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Photographs of the Test Setup Model: TRX-DT2-BLU Radiated Emission Below 1GHz Radiated Emission Above 1GHz

Contact Information

Applicant

Zhou chi(Deputy General Manager)
[email protected]Fax: 13040853097

Test Firm

Shenzhen HongBiao Certification& Testing Co., LtdLeo Su
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz300.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.