FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Financial Future(Beijing) Information Technology Co., Ltd./
  3. 2BSYS-A2515

2BSYS-A2515Intel BE200

Financial Future(Beijing) Information Technology Co., Ltd.
Intel BE200 - FCC ID 2BSYS-A2515 - Financial Future(Beijing) Information Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
6XD - 15E 6 GHz Low Power Indoor Client
Date of Grant
Mar 19, 2026
Application Purpose
Original Equipment
Equipment Note
Intel BE200
Frequency Range
5955.00000000 - 7115.00000000
Company
Financial Future(Beijing) Information Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗
↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Declaration Letter We (Financial Future(Beijing) Information Technology Co., Ltd.) declare that the module has shut down U-NII bands 5 & 8 through software and these bands are now under the control of a standard power access point. Only the function of U-NII bands 5 - 8 being under the control of a low-power indoor access point (P1) is retained.There are no other hardware changes or software parameter changes to the product.We re-provided the report in accordance with the requirements of the 6XD type, re-evaluated the power and power spectral density, and the CBP test items. Other test data refer to the original report of the module(FCC ID:PD9BE200NG). FCC Identifier: 2BSYS-A2515 Product Name: Intel BE200 Model Number: BE200NGW Name:Dong ZhiDate: 12/19/2025 Title: ProjectManager Signature of applicant:

Test Report

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`S!0& OaVVS`Xa] Xb_S + cdefghi ehi je hi klmnf >     4 o+  p)+  , +(  $ + $'$  ,$+$          ! !!! !! !!!! !!! !!""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" # #" $%&' () %* +,% %- ./!! !!! !!! ! !!!! !!""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" 0 1" 2*34%& ( ,5,% 6,5&/"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" 0 0" .5& 7 8/5 &4 25*,&,% 9 : ;< =  : >? ? @A = B C    ;D B  EF;GD=  G H" (-,&,% * I*&,5&,*5 ) %&%% '-- ,% 65& J'&)4"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" K L%%M L" JI & I5 N9 @ ;D O> 9P NC   = D QQ QQ QQQQ QQQ QQQ Q 9R L%%M S" L%& %% T*&,% U9 N  V O<= WG X<=G9Y UC N  ?G= G G<=G < @N ;G C         ! "# $% &' '(( )*+#, +*%-. /0 1 23456 78 978 :;< =2456 > 9 7 :;< =?456 7 9  :;< =@456 8A 9 A7 :;< =B456 A7 9  :;< =C456  9 D :;< @2456 D7 9E87 :;< @=456 E87 9E 7 :;< @F456 E 7 9EA :;< FG 456 EA 9A>7 :;< ;"+ :H' 7E 97 D IJK LJMN LJLL LJOM LJOM LJL LJKN LJOP LJOP LJNO 2 QRS  TUV 5VW TUV X TUV QYV ZVVS[ Q  -#.( \((0         ! "#$  "%& # &  ' ()*+ , -. /() 0 +1+, 2 /3.4 ( 5*66 7- 43 84(,9 + :   $        !"#$%&#' ()* +!,- . / '0. #1 ' 2.3 4& 2.3 4# 4& 567 89:;9< 69=>?:@ 7ABCDE9 F9D<;GH= 5IJKL MNOPKIQRO SISKTQTU SISUTQTU VW 8>;=XH F9D<;GH= UORR7 MNOSIIR 6LV 6LV MYC=;Z7[;< \?<;=;?A9: L?A=:?CC9: 5]8Z^;A_G:9A SIRI 6T7 6LV 6LV M9_;Y`ZaY=D \?<;=;?A9: 5]8Z^;A_G:9A SIK 6T7 6LV 6LV M9B<Y:9`9A= b?:A 7A=9AAB 5MLc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

Test Report

                 ! " # $%   &  ' ()*+ ,)-./0, 123 4567),89:/) ;<3 =>?@ )84A   B C        D CCE $ C !&   EE  FD  $$ G % HI% D G% J % KCLMC C$%  N C C OC'% CN    EP  CQE"  #GHGR SR HRT   ' ! " % C  @)84A C     U JC NQ P $$ !VC&W XYZ[\] H^ RH^ TL _YX[\] G R H TL _Y`[\] H R  TL _Ya[\] ^I R IH TL _Yb[\] IH R  TL _Yc[\]  R S TL aYX[\] SH RB^H TL aY_[\] B^H RB H TL aYd[\] B H RBI TL dYe [\] BI RIGH TL CQ E" HS ^  ^GG G G ^^  H ^IG ^^S ^SB OP $$ P'  EP   C fghij kl fghij ijmnop!& fghij qrgsjojt! & usvjqgmwj!M& fxmmjwoxt oyvj CQ E"  S GR SR RT GHz  GG D  T EJ W     U {C  |EC  P CJ  $ C $'$  P$C$          ! !!! !! !!!! !!! !! """"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" # #" $%&'() * +,+( -+,)."""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" / 0" 1,) 2 3., )' $,%+)+( 45 6 78 9  6 :; ; <= 9 > 44    7? > 4 @A7B?9  B > C" *D+)+( % E%)+,)+%, F ()(( GDD +( -,) HG)F'"""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""" I J((K J" HE ) E, L5 < 7? M: NOP QRST SUV WXRYY YY YYYY YYY YYY YOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOOO Z         !  "# $% "  &'()* +)), - - .-/         ! "#$  "%& # &  ' ()*+ , -. /() 0 +1+, 2 /3.4 ( 5*66 7- 43 84(,9 +    $ : ;<$  =            ! "#$%&' $ ()* ))+  +,-+*-) .+** /)0 12 345 ()* ))+  +,-+*-) .+** /)0 12 345                                      

Test Report

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC 47 CFR PART 15 SUBPART E TEST REPORT For Intel BE200 MODEL NUMBER: BE200NGW REPORT NUMBER: 4792146700.1-RF-7 ISSUE DATE: Mar 13, 2026 FCC ID: 2BSYS-A2515 Prepared for Financial Future(Beijing) Information Technology Co., Ltd. Room 12-01, 10th Floor, Building 38, Haidian Street, Haidian District, Beijing Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792146700.1-RF-7 Page 2 of 60 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 3/13/2026 Initial Issue REPORT NO.: 4792146700.1-RF-7 Page 3 of 60 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Test Item Clause Limit/Requirement Result On Time And Duty Cycle ANSI C63.10-2020+Cor 1- 2023, Clause 12.2 None; for reporting purposes only. Pass 26dB Emission Bandwidth And 99% Occupied Bandwidth KDB 789033 D02 v02r01 Section C.1 FCC Part 15.407 (a) (10) Pass Conducted Output Power KDB 789033 D02 v02r01 Section E.3.a (Method PM) FCC 15.407 (a) Pass Power Spectral Density KDB 789033 D02 v02r01 Section F FCC 15.407 (a) Pass In-Band Emissions (Mask) KDB 987594 D02 U-NII 6GHz EMC Measurement v01r01 J FCC 15.407 (b) Pass Frequency Stability ANSI C63.10-2020+Cor 1- 2023,Clause 6.8 FCC 15.407 (g) Pass Contention-based Protocol KDB 987594 D02 U-NII 6 GHz EMC Measurement v03 FCC 15.407 (d) (6) Pass Radiated Emissions And Band Edge Measurement KDB 789033 D02 v02r01 Section G.3, G.4, G.5, and G.6 FCC 15.407 (b) FCC 15.209 FCC 15.205 Pass AC Power Line Conducted Emission ANSI C63.10-2020+Cor 1- 2023, Clause 6.2. FCC 15.207 Pass Antenna Requirement N/A FCC 47 CFR Part 15.203/ 15.407(a)(1) (2) Pass *This test report is only published to and used by the applicant, and it is not for evidence purpose in China. *The measurement result for the sample received is <Pass> according to <FCC 47 CFR PART 15 SUBPART E Note: The FCC Equipment code of the module has been changed from 6CD to 6XD base on RF module(FCC ID: 2BSYS-A2515 ). So evaluated the Radiated Spurious Emission, contention based protocol and output power items. For the test results of all other test items please refer to module test reports. REPORT NO.: 4792146700.1-RF-7 Page 4 of 60 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO: 10-SL-F0035 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. CONTENTS 1. ATTESTATION OF TEST RESULTS ..................................................................................... 5 2. TEST METHODOLOGY ......................................................................................................... 7 3. FACILITIES AND ACCREDITATION ..................................................................................... 7 4. CALIBRATION AND UNCERTAINTY ................................................................................... 8 4.1. MEASURING INSTRUMENT CALIBRATION ........................................................... 8 4.2. MEASUREMENT UNCERTAINTY ............................................................................ 8 5. EQUIPMENT UNDER TEST .................................................................................................. 9 5.1. DESCRIPTION OF EUT ........................................................................................... 9 5.2. CHANNEL LIST ........................................................................................................ 9 5.3. MAXIMUM POWER ................................................................................................ 13 5.4. TEST CHANNEL CONFIGURATION ...................................................................... 14 5.5. THE WORSE CASE POWER SETTING PARAMETER .......................................... 16 5.6. DESCRIPTION OF AVAILABLE ANTENNAS ......................................................... 17 5.7. SUPPORT UNITS FOR SYSTEM TEST ................................................................. 18 6. MEASURING EQUIPMENT AND SOFTWARE USED......................................................... 19 7. ANTENNA PORT TEST RESULTS ..................................................................................... 22 7.1. CONDUCTED OUTPUT POWER ........................................................................... 22 7.2. POWER SPECTRAL DENSITY .............................................................................. 25 7.3. CONTENTION-BASED PROTOCOL ...................................................................... 27 8. RADIATED TEST RESULTS ............................................................................................... 31 8.1. RESTRICTED BANDEDGE .................................................................................... 39 8.2. SPURIOUS EMISSIONS(1 GHZ~40 GHZ) ............................................................. 43 8.3. SPURIOUS EMISSIONS(30 MHZ~1 GHZ) ............................................................. 49 9. ANTENNA REQUIREM…

Text truncated - open the document above for the full version.

Test Report

           ! "# $% &# ' ''       ( &)#  *+,-./0123456787/7497,4:7443;3:3<=77: >?@ABCDEAFAGH@AHIJKBGKLACHMNCHAF  OPQRQSTUVQRQWXRQXPYZ[T\STQZYW]^T_PQV[`SaRQSTUVQRQWXUT[WbSZ[TXV[\UXQZSc[TXQTXTdTXQR TPYeW [WXPQf[bUVQT\QaYeg  h?LACHMAHDijklDmiFAGHnmCH h?>?LACHMAHDi h?>?>?ompmqrLstuvwsuxxysuz{@|}~BGKompmvw€x‚s@|}~  h?>?h?ompmƒvw‚sy„sxx@|}~               ! "# $% &# ' ''       ( &#  )*)*+,-./01234,5.62-. )*7*8292:;<=>:<??@:<ABCDEFG5H8292I=>IJI?KIL:ICDEF  MNON,P2Q,+R3,SCTH,UV,W2GUOCG51XGQ.1W,W YZ[\YYY]^_`abcdefgeedh`c_ibcc_djk`alm]\nop[\ZqYqrZost]\ubhvwa`h YZ[\YZZm`dxga`j`hy]ifyzda`sm{g`xy|Z}Zqkgbevpr[~rZ~Y~st]\ubhvwa`h YZ[\YYZ]zbyc_€ixbybihbhwihyaie€edyfiaj sm`hy`aYYZqorqnst]\ubhvwa`h YZ[\YY[]‚xy`jlj^ebfb`amivge`ƒY}q\„…†‡ˆ]lm\YZ\st]\ubhvwa`h prZ\YYY]bwhdelhde‚‡`ao‰†‡Š„…†‡‹]u„ZYpZ~[Œi_v`]c_zda‡ Z[Y\YYY]bwhdew`h`adyia]mZYYlZrnpZrŒi_v`]c_zda‡  )*Ž*8292=>IL:I@:??CDEF  MNON,P2Q,+R3,SCTH,UV,W2GUOCG51XGQ.1W,W YYo\YYY]^_`abcdefgeedh`c_ibcc_djk`a‘€t€pnr„q\YY„qZ\YYZ\€ŒŒi_v`]c_zda‡ YYo\YYZm`dxga`j`hyxifyzda`ƒ|ZZ}[Yˆlm][pZYYYn~Œi_v`]c_zda‡ Zqp\YYYaixx\^iedab‡`v|b|devbdhy`hhdt\tlnq€ZYZYZnŒi_v`]c_zda‡ [~q\YYY]zbyc_ghby’u“lt\sulm€\”Zq[[}„[qY}YpŒi_v`]c_zda‡ [[q\YYY€ixbybihh`a“”Zr[Z„rqrrmdygai Z~[\YYY]^`cyagjdhde‚x`a•–l“oY~Y•]qrpZppZY—`‚xbw_y Z[Y\YYY]bwhdew`h`adyia]mZYYlZrnpZrŒi_v`]c_zda‡  7*˜5.,55GV3,Q2X2QG.2T5  !™š#› œ  › !› (#  lhy`hhd…dbhj`dxga`j`hyk`eiz„…†‡l}l‡b‡`…bek`ay lhy`hhd…dbhj`dxga`j`hydki|`„…†‡t}lhvabdjb_dab|iedj`hd 7*ž*˜5.,55G25XTW4G.2T5  CG51XGQ.1W,W+R3, ˜5.,55GŸGW. 514 ,W ¡G5HŸ,G¢=G25>H¡2F +GW£,.Ÿ,G¢=G25 >H¡2F ¤hy`e‘Œ‹udkŸM9˜ ‘Œ‹\tabdhv\ lhy`hhd :;<=DE p~YY\p~n[m†‡ p}oq[ I;:=DE q}ZqYŠq}pqYm†‡ q}ZZ q I;<=DE qpqY\q~rYm†‡ q}Zq I;=DE q~rY\qrpqm†‡ q}Zq I;A=DE qrpq\qopqm†‡ q}Z[ ;:=DE qopq\„~pqm†‡ q}Yp q ;I=DE „~pq\„qpqm†‡ q}Yp ;=DE „qpq\„nrqm†‡ ~}o„ =DE „nrq\rZpqm†‡ ~}o„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`abc  def_ghij_  k]l`]__]m      no p q   r s t p u vwx y vxz v{ vy | } ~ €p‚ƒ„…{†‡† ˆ‰Š‹oƒpŒq…†‡† Œ‰‰…v{†‡† no p q   r s t p u vwx y vxz v{ vy ~| } €p‚ƒ„…v{†‡† ˆ‰Š‹oƒpŒq…†‡† Œ‰‰…{†‡† no p q   r s t p u vwx y vxz v{ vy ~ } | €p‚ƒ„…xކ‡† ˆ‰Š‹oƒpŒq…v{†‡† Œ‰‰…†‡† no p q   r s t p u vwx y vxz v{ vy |~ } €p‚ƒ„…†‡† ˆ‰Š‹oƒpŒq…{†‡† Œ‰‰…†‡† no p q   r s t p u vwx y vxz v{ vy ~ |} €p‚ƒ„…{†‡† ˆ‰Š‹oƒpŒq…†‡† Œ‰‰…†‡† no p q   r s t p u vwx y vxz v{ vy } ~ | €p‚ƒ„…v{†‡† ˆ‰Š‹oƒpŒq…xކ‡† Œ‰‰…†‡†            ! "# $% &# ' ''       ( & #   )*+*,*-./0..121//03.456789:;  201<=1>. [email protected]D9:;E :F3>;F./1GDHI0/1EJ03/>B1GD2I>EHF/1G DKL>EDKL>EDKL>E   MNOPQROST UV   WXYZ[\]^_  `ab[cdef[  gYh\Y[[Yi      jk l m   n o p l q rst u rsv rsw rx ry ru z { | } ~l€‚ƒ„xz…z †‡ˆ‰k‚lŠm„z…z ‹Š‡‡„rxz…z jk l m   n o p l q rst u rsv rsw rx ry ru z }{ | ~l€‚ƒ„rxz…z †‡ˆ‰k‚lŠm„z…z ‹Š‡‡„xz…z jk l m   n o p l q rst u rsv rsw rx ry ru z | }{ ~l€‚ƒ„stz…z †‡ˆ‰k‚lŠm„rxz…z ‹Š‡‡„z…z jk l m   n o p l q rst u rsv rsw rx ry ru z { | } ~l€‚ƒ„z…z †‡ˆ‰k‚lŠm„xz…z ‹Š‡‡„z…z jk l m   n o p l q rst u rsv rsw rx ry ru z } {| ~l€‚ƒ„xz…z †‡ˆ‰k‚lŠm„z…z ‹Š‡‡„z…z jk l m   n o p l q rst u rsv rsw rx ry ru z | } { ~l€‚ƒ„rxz…z †‡ˆ‰k‚lŠm„stz…z ‹Š‡‡„z…z            ! "# $% &# ' ''       ( &'#  )*+*,*-./0..121//03.456789:;  201<=1>. [email protected]D9:;E :F3>;F./1GDHI0/1EJ03/>B1GD2I>EHF/1G DKL>EDKL>EDKL>E M NOPOQRPQS TU  VWXYZ[\]^  _`aZbcdeZ  fXg[XZZXh      ij k l   m n o k p qrs t quv qur qw x y z {|k}~€‚ƒ„ƒ …†‡ˆjk‰lƒ„ƒ Љ††q‚ƒ„ƒ ij k l   m n o k p qrs t quv qur qw zx y {|k}~€q‚ƒ„ƒ …†‡ˆjk‰lƒ„ƒ Љ††‚ƒ„ƒ ij k l   m n o k p qrs t quv qur qw z y x {|k}~€uvƒ„ƒ …†‡ˆjk‰lq‚ƒ„ƒ Љ††ƒ„ƒ ij k l   m n o k p qrs t quv qur qw xz y {|k}~€ƒ„ƒ …†‡ˆjk‰l‚ƒ„ƒ Љ††ƒ„ƒ ij k l   m n o k p qrs t quv qur qw z xy {|k}~€‚ƒ„ƒ …†‡ˆjk‰lƒ„ƒ Љ††ƒ„ƒ ij k l   m n o k p qrs t quv qur qw y z x {|k}~€q‚ƒ„ƒ …†‡ˆjk‰luvƒ„ƒ Љ††ƒ„ƒ            ! "# $% &# ' ''       ( &)#  *+,+-./.01203045067089:; *+,+<+=>?@>>ABA??@C>D030489:  B@AE1A.> /C@FG@>HI289:; 9JC.:J>?AK2LM@?A;N@C?.HAK2BM.;LJ?AK 2OP.;2OP.;2OP.; …

Text truncated - open the document above for the full version.

RF Exposure Info

The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. FCC RF EXPOSURE REPORT For Intel BE200 MODEL NUMBER: BE200NGW REPORT NUMBER: 4792146700.1-RF-8 ISSUE DATE: Feb 25, 2026 FCC ID: 2BSYS-A2515 Prepared for Financial Future(Beijing) Information Technology Co., Ltd. Room 12-01, 10th Floor, Building 38, Haidian Street, Haidian District, Beijing Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4792146700.1-RF-8 Page 2 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 2/25/2026 Initial Issue REPORT NO.: 4792146700.1-RF-8 Page 3 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 4 2. TEST METHODOLOGY ..................................................................................................... 6 3. FACILITIES AND ACCREDITATION ................................................................................. 6 4. REQUIREMENT ................................................................................................................. 7 REPORT NO.: 4792146700.1-RF-8 Page 4 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Applicant Information Company Name: Financial Future(Beijing) Information Technology Co., Ltd. Address: Room 12-01, 10th Floor, Building 38, Haidian Street, Haidian District, Beijing Manufacturer Information Company Name: Financial Future(Beijing) Information Technology Co., Ltd. Address: Room 12-01, 10th Floor, Building 38, Haidian Street, Haidian District, Beijing EUT Information EUT Name: Intel BE200 Model: BE200NGW Sample Received Date: Feb 10, 2026 Sample Status: Normal Sample ID: 9445241 Date of Tested: Feb 10, 2026- Feb 25, 2026 REPORT NO.: 4792146700.1-RF-8 Page 5 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. APPLICABLE STANDARDS STANDARD TEST RESULTS FCC 47CFR§2.1091 PASS KDB447498 D01 V06 PASS Prepared By: Checked By: Johnson Liu Fanny Huang Laboratory Engineer Project Engineer Approved By: Kebo Zhang Operations Leader REPORT NO.: 4792146700.1-RF-8 Page 6 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 2. TEST METHODOLOGY The tests documented in this report were performed in accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 and KDB 447498 D01 General RF Exposure Guidance v06. 3. FACILITIES AND ACCREDITATION Accreditation Certificate A2LA (Certificate No.: 4102.01) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1187) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. Has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. ISED (Company No.: 21320) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been registered and fully described in a report filed with ISED. The Company Number is 21320 and the test lab Conformity Assessment Body Identifier (CABID) is CN0046. VCCI (Registration No.: C-20202, G-20240, R-20248 and T-20202) UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch. has been assessed and proved to be in compliance with VCCI, the Membership No. is 3793. Facility Name: Chamber E, the VCCI registration No. is G-20240 and R-20248 Shielding Room F, the VCCI registration No. is C-20202 and T-20202 Note 1: All tests measurement facilities use to collect the measurement data are located at Room 101, Building 2, No.4, Information Road, Songshan Lake, Dongguan, Guangdong, China. Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site. Note 3: For below 30 MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. And these measurements below 30 MHz had been correlated to measurements performed on an OFS. REPORT NO.: 4792146700.1-RF-8 Page 7 of 8 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM No.: 10-SL-F0112 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 4. REQUIREMENT LIM…

Text truncated - open the document above for the full version.

External Photos

            !" #$ %" & &&       ' %(")  *+,-./--0123.3 453-.6078                   ! " #"$% &  ! " '(! )# ! *"+ ,-.  /-- /-01 201 3 4 505

External Photos

Page 1 of 1 Photos of the EUT Product Name : Intel BE200 Model Number : BE200NGW

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization <FinancialFuture(Beijing)InformationTechnologyCo.,Ltd.> Company:FinancialFuture(Beijing)InformationTechnologyCo.,Ltd. Address:Room12-01,10thFloor,Building38,HaidianStreet,HaidianDistrict, Beijing ProductName:IntelBE200 ModelNumber:BE200NGW FCCIdentifier:2BSYS-A2515 WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:DongZhiDate:12/19/2025 Title:ProjectManager Signatureofapplicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 <FinancialFuture(Beijing)InformationTechnologyCo.,Ltd.> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2025-12-19 Subject:RequestforConfidentiality FCCID:2BSYS-A2515 ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/LocationNoNo Attestation StatementNoNo External PhotosNo ☐ Block Diagram ☐☐ Schematics ☐ ☐ Test ReportNoNo Test Setup PhotosNo ☒ User’s Manual ☐NOTE 1 ☒ Internal Photos ☐NOTE 1 ☒ Parts List / Tune Up ☐☐ RF Exposure InfoNoNo Operational Description ☒☐ Cover Letter(s)NoNo SDR Software / Security InfoNo NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERM CONFIDENTIALITY,Section3ofKDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof___180___daysfromthedateof theGrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential C5266091_X10_Ed.2 1/1 documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, Signature: Name:DongZhi Title:ProjectManager

Attestation Statements

TCB CALL página 1 File FCC ID: 2BSYS-A2515 Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Dong Zhi(Project Manager)
[email protected]Fax: NA

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue, Saint Charles, IL, 60174, US · Saint Charles, 60174 · United States

Test Firm

UL Verification Services (Guangzhou) Co., Ltd.Stephen Guo
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.96 GHz - 7.12 GHz12.00 mW
215E5.96 GHz - 7.08 GHz25.00 mW
315E5.99 GHz - 7.03 GHz49.00 mW
415E6.03 GHz - 6.99 GHz93.00 mW
515E6.11 GHz - 6.91 GHz163.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Single Modular Approval. Power Output listed is EIRP. Device is a 2 x 2 MIMO configuration, enabled for 6 GHz operations as described in this filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. U-NII bands 5 ~ 8 are under the control of a standard power access point function is turned off by software for this module. Module just support U-NII bands 5~8 are under the control of a low-power indoor access point (P1) function.