Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Odyssey Robot LLC Applicant as U.S. Agent Letter of Attestation Date: 2026-01-12 To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BSYT-YMAWZOD Odyssey Robot LLC (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID . The applicant acknowledges that they will maintain an agent for no less than one year after t he grantee has terminated all marketing and importation or t he conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. Designated U.S. Agent from Applicant Company Company Name: Odyssey Robot LLC Contact Person: Randolph Howard Eason Address: 21 Miller Alley Suite210, Pasadena, CA 91103 E-mail: [email protected] Phone: +1 702-266-3242 FCC FRN: 0037628245 Sincerely yours, Signature Printed Name: Randolph Howard Eason E-mail: [email protected] Phone:+1 702-266-3242
Odyssey Robot LLC Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 2026-01-12 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BSYT-YMAWZOD [Odyssey Robot LLC] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Printed Name: Randolph Howard Eason Title: Compliance Director Address: 21 Miller Alley Suite210, Pasadena, CA 91103 E-mail: [email protected] Phone: +1 702-266-3242
Odyssey Robot LLC Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 2026-01-12 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BSYT-YMAWZOD [Odyssey Robot LLC] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Randolph Howard Eason Title: Compliance Director Address: 21 Miller Alley Suite210, Pasadena, CA 91103 E-mail: [email protected] Phone: +1 702-266-3242
TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 Odyssey Robot LLC Authority to Act as Agent Date: 2026-01-12 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TUV Rheinland of North American Inc., 1279 Quarry Lane, Suite A, Pleasanton, CA 94566, USA to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with 21 Miller Alley Suite210, Pasadena, CA 91103 For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 2026-01-12 Agreement is valid for 12 months from the above date. By: ______________________ (Signature) Compliance Director (Title) Randolph Howard Eason (Print name) +1 702-266-3242 (Telephone) On behalf of: Odyssey Robot LLC (Company Name)
Request for Confidentiality Letter Number: MS0044715 Revision: 1 Effective date: Sep 12, 2022 Author: William Graff Owner: William Graff MS-0044715 Page 1 of 1 Revision 1 Legal Scope: Global Business Scope: Cross Business Process Scope: Cross Process Odyssey Robot LLC Date: 2026-01-12 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BSYT-YMAWZOD Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent User’s Manual*** Short Term Permanent Part List Short Term Permanent Software Security Information Odyssey Robot LLC has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: _______________________________________________ Randolph Howard Eason (Signature/Title) (Print name) E-mail: [email protected] Phone: +1 702-266-3242
Odyssey Robot LLC 21 Miller Alley Suite 210, Pasadena, CA 91103 Contact No.: +1 702-266-3242 Contact Email: [email protected] Date: 02-06-2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Subject: Declaration Letter for FCC ID 2BSYT-YMAWZOD Dear Sir/Madam, We, Odyssey Robot LLC, hereby declare that the product Remote Controller, with FCC ID 2BSYT- YMAWZOD, has been developed, designed, manufactured, and assembled by the following companies: 1.Designed by: Company : Odyssey Robot LLC Address: 21 Miller Alley Suite 210, Pasadena, CA 91103 2.Manufactured by: Company : Odyssey Robot LLC Address: 21 Miller Alley Suite 210, Pasadena, CA 91103 3.Assembled by: Company : ETak Worldwide Corporation Address: 901 Avenue S., Suite A, Grand P Prairie, TX 75050 United States 4.Developed by: Company : Odyssey Robot LLC Address: 21 Miller Alley Suite 210, Pasadena, CA 91103 We confirm that the above information is accurate and true to the best of our knowledge. Should you have any questions or require further information, please do not hesitate to contact us. Sincerely, Company Name: Odyssey Robot LLC Contact Person: Randolph Howard Eason Title:Compliance Director By: _______________________ (Signature) Address: 21 Miller Alley Suite210, Pasadena, CA 91103 E-mail: [email protected]; Phone: +1 702-266-3242
Label and Location Label: Location: on the botton of the device.
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26NHAO 004 Auftrags-Nr.: Order no.: 168585292 Seite 1 von 31 Page 1 of 31 Kunden-Referenz-Nr.: Client reference no.: Auftragsdatum: Order date: 2025-11-16 Auftraggeber: Client: Odyssey Robot LLC Address: 21 Miller Alley Suite210, Pasadena, CA 91103 Prüfgegenstand: Test item: Remote Controller Bezeichnung / Typ-Nr.: Identification / Type no.: YMAWZOD Auftrags-Inhalt: Order content: SAR Test Report Prüfgrundlage: Test specification: FCC 47 CFR § 2.1093 IEEE Std 1528-2013 Published RF exposure KDB procedures Wareneingangsdatum: Date of sample receipt: 2025-11-18 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004141367-007 Prüfzeitraum: Testing period: 2025-12-18 ~ 2025-12-19 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Bell Hu genehmigt von: authorized by: X Signed by: Jonathan Li Datum: Date: 2026-01-09 Ausstellungsdatum: Issue date: 2026-01-09 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BSYT-YMAWZOD Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26NHAO 004 Test report no.: Seite 2 von 31 Page 2 of 31 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based on numerical measurem…
Text truncated - open the document above for the full version.
1 Antenna Specification Sheet 2 Content SECTION Page 1 Basic Specifications 3 2 Gain Specifications 4 3 Detailed Radiation Pattern 5 4 Structure drawing 9 3 1 Basic Specifications Antenna Name: RC Ant 1, and RC Ant 2 Operation Frequency: 2.4~2.4835GHz, 5.725~5.850GHz Gain: 2.9dBi (2.4~2.483GHz), 3.9dBi (5.725~5.850GHz) Antenna type: Integral Antenna Connector Type: Ipex-1 Impedance: 50ohm Efficiency: ≥50% VSWR: ≤2 Manufacturer: Shenzhen ZTX Communication Technology Co., LTD. No.34 Shilong Road, Bao'an District, Shenzhen, Guangdong Province 4 2 Gain Specifications Antenna efficiency/Return Loss/VSWR Frequency gain(dBi)R efficiency(%)R Gain(dBi)L efficiency(%)L 2400MHz 2.0 65% 2.1 65% 2420MHz 2.9 68% 2.8 67% 2440MHz 2.965% 2.5 67% 2450MHz 2.3 69% 2.2 66% 2460MHz 2.1 63% 2.2 68% 2480MHz 2.0 64% 2.1 66% 5700MHz 3.5 59% 3.6 59% 5750MHz 3.5 59% 3.6 59% 5800MHz 3.8 61% 3.7 61% 5850MHz 3.9 62% 4.0 63% 5 3 Detailed Radiation Pattern Test lab Satimo SG24 Test date 2025/11/16 Ant 1 6 7 Ant 2 8 9 4 Structure drawing
Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26NHAO 002 Auftrags-Nr.: Order no.: 168585292 Seite 1 von 22 Page 1 of 22 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-11-16 Auftraggeber: Client: Odyssey Robot LLC Address: 21 Miller Alley Suite210, Pasadena, CA 91103 Prüfgegenstand: Test item: Remote Controller Bezeichnung / Typ-Nr.: Identification / Type no.: YMAWZOD Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15: Subpart C Section 15.247 CFR Title 47 FCC Part 15: Subpart C Section 15.209 Wareneingangsdatum: Date of sample receipt: 2025-11-16 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004155498-001~008 Prüfzeitraum: Testing period: 2025-11-20 - 2025-12-29 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Bell Hu genehmigt von: authorized by: X Signed by: Jonathan Li Datum: Date: 2026-01-09 Ausstellungsdatum: Issue date: 2026-01-09 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BSYT-YMAWZOD This report is for 2.4GHz DTS. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26NHAO 002 Test report no.: Seite 2 von 22 Page 2 of 22 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2021, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision r…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 1 of 114 Appendix B: Test Results of 2.4GHz Band APPENDIX B: TEST RESULTS OF 2.4GHZ BAND ............................................................................................................... 1 APPENDIX B.1: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY ..................................................................................... 2 2.4GHz Band, 1.4MHz BW ............................................................................................................................................ 2 2.4GHz Band, 3MHz BW ............................................................................................................................................... 5 2.4GHz Band, 5MHz BW ............................................................................................................................................... 8 2.4GHz Band, 10MHz BW ........................................................................................................................................... 11 2.4GHz Band, 20MHz BW ........................................................................................................................................... 14 2.4GHz Band, 40MHz BW ........................................................................................................................................... 17 APPENDIX B.2: TEST RESULTS OF 6DB BANDWIDTH .................................................................................................................. 20 2.4GHz Band, 1.4MHz BW .......................................................................................................................................... 20 2.4GHz Band, 3MHz BW ............................................................................................................................................. 22 2.4GHz Band, 5MHz BW ............................................................................................................................................. 24 2.4GHz Band, 10MHz BW ........................................................................................................................................... 26 2.4GHz Band, 20MHz BW ........................................................................................................................................... 28 2.4GHz Band, 40MHz BW ........................................................................................................................................... 30 APPENDIX B.3: TEST RESULTS OF 99% BANDWIDTH ................................................................................................................. 32 2.4GHz Band, 1.4MHz BW .......................................................................................................................................... 32 2.4GHz Band, 3MHz BW ............................................................................................................................................. 34 2.4GHz Band, 5MHz BW ............................................................................................................................................. 36 2.4GHz Band, 10MHz BW ........................................................................................................................................... 38 2.4GHz Band, 20MHz BW ........................................................................................................................................... 40 2.4GHz Band, 40MHz BW ........................................................................................................................................... 42 APPENDIX B.4: TEST RESULTS OF CONDUCTED SPURIOUS EMISSIONS MEASURED IN 100 KHZ BANDWIDTH ....................................... 44 Conducted Spurious Emission .................................................................................................................................... 44 2.4GHz Band, 1.4MHz BW .......................................................................................................................................... 44 2.4GHz Band, 3MHz BW ............................................................................................................................................. 48 2.4GHz Band, 5MHz BW ............................................................................................................................................. 52 2.4GHz Band, 10MHz BW ........................................................................................................................................... 56 2.4GHz Band, 20MHz BW ........................................................................................................................................... 60 2.4GHz Band, 40MHz BW ........................................................................................................................................... 64 Band edge................................................................................................................................................................... 68 2.4GHz Band, 1.4MHz BW .......................................................................................................................................... 68 2.4GHz Band, 3MHz BW ............................................................................................................................................. 69 2.4GHz Band, 5MHz BW ............................................................................................................................................. 70 2.4GHz Band, 10MHz BW ........................................................................................................................................... 71 2.4GHz Band, 20MHz BW .........................................................................................................................…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 29 of 114 2.4GHz Band_Ant1_2414.48 2.4GHz Band_Ant1_2437.48 2.4GHz Band_Ant1_2460.48 Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 30 of 114 2.4GHz Band, 40MHz BW TestMode Antenna Channel DTS BW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 2.4GHz Band Ant1 2414.48 17.840 2405.660 2423.500 0.5 PASS 2437.48 17.960 2428.500 2446.460 0.5 PASS 2460.48 17.920 2451.540 2469.460 0.5 PASS Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 31 of 114 2.4GHz Band_Ant1_2414.48 2.4GHz Band_Ant1_2437.48 2.4GHz Band_Ant1_2460.48 Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 32 of 114 Appendix B.3: Test Results of 99% Bandwidth Note: This testing was carried out on both antenna port 1 and port 2, but only the worst case was presented in this report. 2.4GHz Band, 1.4MHz BW TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 2.4GHz Band Ant1 2414.48 4.4000 2412.3063 2416.7063 --- --- 2434.48 4.3986 2432.3215 2436.7201 --- --- 2459.48 4.3814 2457.3287 2461.7101 --- --- Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 33 of 114 2.4GHz Band_Ant1_2414.48 2.4GHz Band_Ant1_2434.48 2.4GHz Band_Ant1_2459.48 Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 34 of 114 2.4GHz Band, 3MHz BW TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 2.4GHz Band Ant1 2411.48 2.2448 2410.3789 2412.6237 --- --- 2435.48 2.2529 2434.3721 2436.6250 --- --- 2459.48 2.2396 2458.3799 2460.6195 --- --- Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 35 of 114 2.4GHz Band_Ant1_2411.48 2.4GHz Band_Ant1_2435.48 2.4GHz Band_Ant1_2459.48 Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 36 of 114 2.4GHz Band, 5MHz BW TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 2.4GHz Band Ant1 2414.48 4.4000 2412.3063 2416.7063 --- --- 2434.48 4.3986 2432.3215 2436.7201 --- --- 2459.48 4.3814 2457.3287 2461.7101 --- --- Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 37 of 114 2.4GHz Band_Ant1_2414.48 2.4GHz Band_Ant1_2434.48 2.4GHz Band_Ant1_2459.48 Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 38 of 114 2.4GHz Band, 10MHz BW TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 2.4GHz Band Ant1 2408.48 9.0345 2403.9811 2413.0156 --- --- 2437.48 9.0182 2432.9937 2442.0119 --- --- 2466.48 9.0168 2461.9900 2471.0068 --- --- Prüfbericht - Produkte Test Report - Products Appendix B CN26NHAO 002 Page 39 of 114 2.4GHz Band_Ant1_2408.48 2.4GHz Band_Ant1_2437.48 2.4GHz Band_Ant1_2466.48 Prüfbericht - Produkte Test R…
Text truncated - open the document above for the full version.
21 Miller Alley Suite210 · Pasadena, California, 91103 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 273.50 mW |
| 2 | 15C | 2.41 GHz - 2.46 GHz | 510.50 mW |
| 3 | 15C | 2.41 GHz - 2.46 GHz | 505.80 mW |
| 4 | 15C | 2.41 GHz - 2.47 GHz | 587.50 mW |
| 5 | 15C | 2.41 GHz - 2.46 GHz | 597.00 mW |
| 6 | 15C | 2.42 GHz - 2.45 GHz | 127.10 mW |