Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RONGTA TECHNOLOGY (M) SDN. BHD. 10, Jalan Korporat 9/KU9, Taman Perindustrian Meru, 42200 Kapar, Selangor D.E Malaysia Date: 04-15-2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BSZZ-RP410 FRN: 0037635489 US Agent – Attestation Statement / Part 2.911(d)(7) RONGTA TECHNOLOGY (M) SDN. BHD. that as of 04-15-2026, we have designated FCC US Agent, LLC to accept service of process on our behalf for FCC ID: 2BSZZ-RP410. RONGTA TECHNOLOGY (M) SDN. BHD. accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. FCC US Agent, LLC, accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of R RONGTA TECHNOLOGY (M) SDN. BHD. for FCC ID: 2BSZZ-RP410. Designated Agent Information: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, Company: RONGTA TECHNOLOGY (M) SDN. BHD. Designated Agent: FCC US Agent, LLC Company Representative: LIN Bruce Designated Agent Representative: Tim Payne Signature: Signature:
RONGTA TECHNOLOGY (M) SDN. BHD. 11‐21‐2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2BSZZ‐RP410 RONGTA TECHNOLOGY (M) SDN. BHD. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber‐security or anti‐virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (LIN Bruce) RONGTA TECHNOLOGY (M) SDN. BHD. 11‐21‐2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2BSZZ‐RP410 RONGTA TECHNOLOGY (M) SDN. BHD. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (LIN Bruce)
RONGTATECHNOLOGY(M)SDN.BHD. Date:Nov.21,2025 FederalCommunicationsCommission AuthorizationandEvaluationDivision ConfidentialityRequestregardingapplicationforcertificationofFCCID:2BSZZ-RP410 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestconfidential treatmentofinformationaccompanyingthisapplicationasoutlinedbelow: ExhibitTypeFileName Long-termconfidentiality: Schematics BlockDiagram OperationalDescription Schematics.pdf BlockDiagram.pdf OperationalDescription.pdf Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthesematerialsmaybeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors. TheapplicantunderstandsthatpursuanttoSection0.457oftheRules,disclosureofthis applicationandallaccompanyingdocumentationwillnotbemadebeforethedateoftheGrant forthisapplication. Sincerely, RONGTATECHNOLOGY(M)SDN.BHD. Signature LINBruce/Manager TypednameandTitle
Appendix- RP410-Photos Page 3 of 9 2. Photographs –Constructional Details 2.1. EUT – External View Model RP410 FCC ID: 2BSZZ-RP410 Appendix- RP410-Photos Page 4 of 9 Appendix- RP410-Photos Page 5 of 9 Appendix- RP410-Photos Page 6 of 9 Appendix- RP410-Photos Page 7 of 9
Appendix- RP410-Photos Page 8 of 9 2.2. EUT – Internal View Model RP410 FCC ID: 2BSZZ-RP410 Appendix- RP410-Photos Page 9 of 9 ======End====== Ant.
Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 8 TEST REPORT Referen ce No. .................... : WTD25D10273413W004 FCC ID ................................ : 2BSZZ-RP410 Applicant ............................ : RONGTA TECHNOLOGY (M) SDN. BHD. Address .............................. : 10, Jalan Korporat 9/KU9, Taman Perindustrian Meru, 42200 Kapar, Selan gor D.E Malaysia Manufacturer .................... : RONGTA TECHNOLOGY (M) SDN. BHD. Address .............................. : 10, Jalan Korporat 9/KU9, Taman Perindustrian Meru, 42200 Kapar, Selan gor D.E Malaysia Product ............................... : Label Printer Model(s). ............................ : RP410 Standards........................... : FCC 47CFR Part 2 Subpart J Section 2.1091 Date of Receipt Sample .... : 2025-10-23 Date of Test ....................... : 2025-10-27 to 2026-04-07 Date of Issue ...................... : 2026-04-07 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian / Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD25D10273413W004 Page 2 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2. Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2. CONTENTS ............................................................................................................................................................ 2 3. REVISION HISTORY ............................................................................................................................................ 3 4. GENERAL INFORMATION .................................................................................................................................. 4 4.1. GENERAL DESCRIPTION OF E.U.T. ............................................................................................................ 4 4.2. DETAILS OF E.U.T. ..................................................................................................................................... 4 4.3. TEST FACILITY ............................................................................................................................................ 5 4.4. SUBCONTRACTED ....................................................................................................................................... 5 4.5. ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 5 5. TEST SUMMARY .................................................................................................................................................. 6 6. RF EXPOSURE ...................................................................................................................................................... 7 6.1. REQUIREMENTS .......................................................................................................................................... 7 6.2. THE PROCEDURES / LIMIT ........................................................................................................................... 7 6.3. MPE CALCULATION METHOD .................................................................................................................... 8 6.4. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ......................................................................... 8 Reference No.: WTD25D10273413W004 Page 3 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 3. Revision History Test Report No. Date of Receipt Sample Date of Test Date of Issue Purpose Comment Approved WTD25D10273413W004 2025-10-23 2025-10-27 to 2026-04-07 2026-04-07Original - Valid Reference No.: WTD25D10273413W004 Page 4 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4. General Information 4.1. General Description of E.U.T. Product: Label Printer Model(s): RP410 Additional models: RP410A, RP410B, RP410C, RP410D, RP410E, RP410F, RP410G, RP410H, RP410I, RP410J, RP410K, RP410L, RP410M, RP410N, RP410O, RP410P, RP410Q, RP410R, RP410S, RP410T, RP410U, RP410V, RP410W, RP410X, RP410Y, RP410Z, RP410HD, MP410, RP411, RP412, RP413, RP414, RP514, RP416, RP417, RP418, RP419, RP***** (*=0-9 or A-Z or blank), MP***** (*=0-9 or A-Z or blank) Model Description: Only the models name, appearance color and screen printing of the shell are different. Model RP410 was tested in this report. Test Sample No.: 1-1/1 Bluetooth Version: BT_8051_V1.0_201203 Hardware Version: RP410_GD303_WBU_V1.0_240315 Software Version: V4.20_250306 4.2. Details of E.U.T. Operation Frequency: Bluetooth: 2402-2480MHz, 79 Channels in total BLE: 2402-2480MHz, 40 Channels in total Max. RF output power: Bluetooth: 6.29dBm BLE: 6.22dBm Modulation Technology: Bluetooth: GFSK, π/4DQPSK, 8DPSK BLE: GFSK Antenna installation: PCB Antenna Antenna Gain: -0.58dBi Note: #: The antenna gain is provided by the applicant, and the applicant should be responsible for its authenticity, WALTEK lab has not verified the authenticity of its information. Ratings: DC 24V ⎓ 2.5A Adapter: Model: ADP-60D24 Input: 100-240V ~ 50/60Hz 1.5A MAX Output: +24.0V ⎓ 2.5A 60.0W Manufacturer: Hunan Dajing Power Technology Co., Ltd Reference No.: WTD25D10273413W004 Page 5 of 8 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 4.3. Test Facility The test facility has a test site registered with the following organizations: ISED CAB…
Text truncated - open the document above for the full version.
Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Horizontal Vertical 2400MHz 2400MHz2500MHz2400MHz2400MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dB Polarization Horizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance 50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) No.333No.333 Kexing Road, Nanping Town, Zhuhai ,China. Address Address Kexing Road, Nanping Town, Zhuhai ,China. Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 -0.585582 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.
Waltek Testing Group Co., Ltd. http://www.waltek.com.cn Page 1 of 34 TEST REPORT Referen ce No. .................... : WTD25D10273413W003 FCC ID ................................ : 2BSZZ-RP410 Applicant ............................ : RONGTA TECHNOLOGY (M) SDN. BHD. Address .............................. : 10, Jalan Korporat 9/KU9, Taman Perindustrian Meru, 42200 Kapar, Selangor D.E Malaysia Manufacturer .................... : RONGTA TECHNOLOGY (M) SDN. BHD. Address .............................. : 10, Jalan Korporat 9/KU9, Taman Perindustrian Meru, 42200 Kapar, Selangor D.E Malaysia Product ............................... : Label Printer Model(s). ............................ : RP410 Standards........................... : FCC 47CFR Part 15.247 Date of Receipt Sample .... : 2025-10-23 Date of Test ....................... : 2025-10-27 to 2026-04-07 Date of Issue ...................... : 2026-04-07 Test Result ......................... : Pass Remarks: The re sults shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group Co., Ltd. Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China Tel: +86-769-2267 6998 Fax: +86-769-2267 6828 Compiled by: Approved by: Estel Qian/ Project Engineer Deval Qin / Designated Reviewer Reference No.: WTD25D10273413W003 Page 2 of 34 Waltek Testing Group Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 CONTENTS ............................................................................................................................................... 2 3 REVISION HISTORY ................................................................................................................................. 4 4 GENERAL INFORMATION ....................................................................................................................... 5 4.1 General Description of E.U.T. ....................................................................................................... 5 4.2 Details of E.U.T. ............................................................................................................................ 5 4.3 Channel List .................................................................................................................................. 6 4.4 Test Facility ................................................................................................................................... 7 4.5 Subcontracted ............................................................................................................................... 7 4.6 Abnormalities from Standard Conditions ...................................................................................... 7 4.7 Test Mode ..................................................................................................................................... 7 5 TEST SUMMARY ...................................................................................................................................... 8 6 EQUIPMENT USED DURING TEST ......................................................................................................... 9 6.1 Equipments List ............................................................................................................................ 9 6.2 Description of Support Units ....................................................................................................... 10 6.3 Measurement Uncertainty .......................................................................................................... 10 6.4 Test Equipment Calibration ........................................................................................................ 10 7 DUTY CYCLE .......................................................................................................................................... 11 8 CONDUCTED EMISSION ....................................................................................................................... 12 8.1 E.U.T. Operation ......................................................................................................................... 12 8.2 EUT Setup .................................................................................................................................. 12 8.3 Measurement Description ........................................................................................................... 12 8.4 Conducted Emission Test Result ............................................................................................... 13 9 RADIATED EMISSIONS ......................................................................................................................... 15 9.1 EUT Operation ............................................................................................................................ 15 9.2 Test Setup .................................................................................................................................. 16 9.3 Spectrum Analyzer Setup ........................................................................................................... 17 9.4 Test Procedure ........................................................................................................................... 18 9.5 Corrected Amplitude & Margin Calculation ................................................................................ 18 9.6 Summary of Test Results ........................................................................................................... 19 10 CONDUCTED SPU…
Text truncated - open the document above for the full version.
Appendix- RP410-Photos Page 1 of 9 1. Test Setup photos Model RP410 FCC ID: 2BSZZ-RP410 1.1 Photograph – Conducted Emission For Conducted Emission Test Site 1# 1.2 Photograph – Radiated Emissions For 9kHz-30MHz Test Site 2# Appendix- RP410-Photos Page 2 of 9 For 30MHz-1000MHz Test Site 2# For Above 1GHz Test Site 1#
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.00 mW |