Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Qwerty keyboard App key Power button Caps Lock Appearance OverviewAppearance OverviewInsert/Remove Sim or TF Card •Push the SIM card metal contacts all the way down into the slot. •Pay attention to the chamfering direction. •The three-in-one card slot can accommodate two SIM cards at the same time, or one SIM card combined with one TF card. Waterproof Safety Notice: This device relies on waterproof plugs to ensure its water resistance. Always make sure the SIM/TF card and Type-C plugs are securely closed after use. An incompletely sealed plug can compromise waterproof protection and cause damage; The waterproof rating is only valid when the plugs are properly sealed; Periodically inspect the plugs for wear or looseness, and replace if necessary. WARNING: Water damage caused by improperly closed plugs is not covered under warranty. Caution Type-c waterproof plug SIM/TF card waterproof plug SIM/TF plug Type-c plug Side custom buttons survey key Function key Number keypad Touchscreen Android navigation key Enter key Camera Flashlight speaker NFC Nameplate Wristband fixation bar Built-in battery Light Sensor/ Indicator Light Directonkey The SIM card is pushed in. Touch Capability •Supports stylus and glove touch modes, ensuring dependable performance in industrial and outdoor usage scenarios. •The controller operates in touch mode by default. However, users may switch to stylus/glove mode via system settings. Once configured, the controller will retain the selected mode even after shutdown and reboot. Quick Start Guide Y55 Switching Machine •Android navigation buttons Corresponding virtual buttons implement the functions of Recent Apps, Home, and Back. •Power Key Hold down for 3 seconds to turn on/off. Hold down for 10seconds to reset. •Directional Keys Short press Up/Down/Left/Right to move accordingly. •APP Key program Associated Shortcuts. •FN Key Custom function keys can be set by software. •Aa Key Aa Input Method Case Switching •OK key Confirmation function. •Survey key In the survey application interface, you can directly start the survey or management function in a short time. •Space key Short press to enter a space, long press to continuously enter a space. •Key Combinations: FN + Up/Down: Adjust volume. FN + Left/Right: Adjust screen brightness. Power + Left: Record video Power + Right: Take screenshot 1.Useonlythebuilt-inrechargeablelithiumbattery.Chargewhenlow;allowfull dischargebeforerechargingforlongerbatterylife. 2.Unplugthechargerwhennotinuse.Donotleavechargingforoveraweek. 3.Chargewithinnormaltemperatures.Letbatterycoolorwarmifneeded. 4.Avoidshortcircuits;donotusedamagedbatteries. 5.Keepbatteryawayfromextremeheatorcold. 6.Donotburnbatteries.Disposeofproperlyperlocallaws . Safety & Battery Instructions ♻ 1.Donotuseinrestrictedareas(airports,hospitals,gasstations). 2.Donotusewhiledrivingornearairbags. 3.Avoiduseduringthunderstorms. 4.Waterproof,butavoidprolongedmoistureexposure. 5.Operatingtemp:-20°C~+65°C;Storage:-30°C~+70°C. 6.Extremetemperaturesmayaffectperformance. 7.Donotmisuseordisassemble.Contactauthorizedserviceforrepair. 8.Disposeresponsiblyatendoflife. 9.ThisisaClassBdeviceandmaycauseradiointerference. Usage Warnings Powered by Yaoyou Android data collector FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This Tablet computer meets the government's requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. Thestandards include a substantial safety margin designed to assure the safety of all persons regardless of age or health. The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. Device types: Android data collector (FCC ID: 2BT3Z-Y55) has also been tested against this SAR limit. The highest SAR value reported under this standard during product certification for when properly worn on the body is 1.245W/kg. This device was tested for typical body-worn operations with the back of the handset kept 0mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a 0mm separation distance between the user's body and the back of the handset. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. This device was tested for typical body-worn operation…
Text truncated - open the document above for the full version.
Anyreproductionofthisdocumentmustbedoneinfull.Nosinglepartofthisdocumentmaybereproducedwithout permissionfromSTS,AllTestDataPresentedinthisreportisonlyapplicabletopresentedTestsample. ShenZhenSTSTestServicesCo.,Ltd. A1/F,BuildingB,ZhuokeSciencePark,No.190ChongqingRoad,HepingShequ,FuyongSub-District,Bao’anDistrict,Shenzhen, GuangDong,China TEL:+86-75536886288FAX:+8 6-75 536886277E-mail:[email protected] S T L A B S SAR DipolePerformanceMeasurement Report EUTType : SARValidationDipoleandWaveguide ModelName : DIP0G750,DIP0G835,DIP1G800,DIP1G900, DIP2G450,DIP2G600,WGA32 BrandName: SATIMO TestConclusion: Pass TestDate:11Dec.2024&03Jul.2025 DateofIssue: 03Jul.2025 TestingEngineer: (Xin.Liu) TechnicalManager: (Shifan.Long) AuthorizedSignatory: (BoveyYang) ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. KindofEquipmentManufacturerTypeNo.SerialNo.LastCalibrationCalibratedUntil PCAcerN/AN/AN/AN/A E-FieldProbeMVGSSE2 SN08/21 EPGO352 2024.09.182025.09.17 DielectricProbeKitMVGSCLMP SN32/14 OCPG67 2024.09.182025.09.17 Phantom1MVGSAM SN32/14 SAM115 N/AN/A Phantom2MVGSAM SN32/14 SAM116 N/AN/A AttenuatorAgilent99899DC-18GHzN/AN/A DirectionalcouplerNarda4226-203305N/AN/A NetworkAnalyzerAgilentE5071CMY465203782024-09-252025-09-26 MultiMeterKeithley MultiMeter 2000 40500732024-09-252025-09-26 SignalGeneratorAgilentN5182AMY501405302024-09-252025-09-26 PowerAmplifierDESAYZHL-42W96382024-09-252025-09-26 PowerMeterR&SNRP1005102024-09-252025-09-26 PowerSensorR&SNRP-Z111019192024-09-252025-09-26 PowerSensorKeysightU2021XAMY562800022024-09-252025-09-26 Temperature hygrometer SuWeiSW-108N/A2024.10.152025.10.14 ThermographElitechRC-4 S/N EF7176501537 2024.10.152025.10.14 ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. KindofEquipmentManufacturerTypeNo.SerialNo.LastCalibrationCalibratedUntil SARTestSystemSATIMON/A V5.3.15.11 N/AN/A DielectricProbeKitMVGSCLMPSN32/14OCPG672025.09.152026.09.14 AntennaMVGANTA3SN07/13ZNTA52N/AN/A Phantom1MVGSAMSN32/14SAM115N/AN/A Phantom3MVGSAMSN21/21ELLI48N/AN/A PhoneholderMVGN/ASN32/14MSH97N/AN/A LaptopholderMVGN/ASN32/14LSH29N/AN/A AttenuatorAgilentHXT-10-8-SMA2403270172025-02-222026-02-21 DirectionalcouplerXi'anXingboXBOH-OA08-20dB211123-4-32025-02-222026-02-21 NetworkAnalyzerAgilentE5071CMY465203782025-09-262026-09-24 MultiMeterKeithleyMultiMeter200040500732025-09-222026-09-21 SignalGeneratorAgilentN5182AMY501405302025-09-262026-09-25 WirelessCommunication TestSet Agilent8960-E5515CMY483607512025-02-222026-02-21 WirelessCommunication TestSet R&SCMW5001563242025-09-252026-09-24 PowerAmplifierDESAYWCS-DLNA50M8G50G1CSKJLNA231227A2025-09-292026-09-28 PowerMeterR&SNRP1005102025-09-252026-09-24 PowerSensorR&SNRP-Z111019192025-09-252026-09-24 PowerSensorKeysightU2021XAMY562800022025-09-252026-09-24 TemperaturehygrometerTOPRIETP502V4-P67000001241982025.10.092026.10.08 ThermographElitechRC-4S/NEF71765015372025.10.172026.10.16 ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. 2.<Justificationoftheextendedcalibration> ReferringtoKDB865664D01,ifdipolesareverifiedinreturnloss<-20dB,(within20%of priorcalibration),andinimpedance(within5ohmofpriorcalibration),theannualcalibration isnotnecessaryandthecalibrationintervalcanbeextended. Head750MHz Dateof Measurement ReturnLoss (dB) Delta(%)ImpedanceDelta(ohm) 2023.07.04-25.47-55.2- 2024.07.01-25.982.0054.86-0.62 2025.07.03-25.992.0253.45-3.16 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5ohmof priorcalibration.Thereforetheverificationresultshouldsupportextendedcalibration. <DipoleVerificationData> Head750MHz ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. Head835MHz Dateof Measurement ReturnLoss (dB) Delta(%)ImpedanceDelta(ohm) 2023.07.04-28.13-51.4- 2024.07.01-28.431.0752.622.37 2025.07.03-28.832.4752.512.16 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5ohmof priorcalibration.Thereforetheverificationresultshouldsupportextendedcalibration. <DipoleVerificationData> Head835MHz ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. Head1800MHz Dateof Measurement ReturnLoss (dB) Delta(%)ImpedanceDelta(ohm) 2023.12.20-27.38/50.2/ 2024.12.11-27.04-1.2348.48-3.43 2025-12-09-27.911.9448.53-7.56 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5ohmof priorcalibration.Thereforetheverificationresultshouldsupportextendedcalibration. <DipoleVerificationData> Head1800MHz ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. Head1900MHz Dateof Measurement ReturnLoss (dB) Delta(%)ImpedanceDelta(ohm) 2023.09-14-23.66-51.4- 2024.07.01-23.62-0.1750.73-1.30 2025.07.03-23.890.9650.62-1.52 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5ohmof priorcalibration.Thereforetheverificationresultshouldsupportextendedcalibration. <DipoleVerificationData> Head1900MHz ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. Head2450MHz Dateof Measurement ReturnLoss (dB) Delta(%)ImpedanceDelta(ohm) 2023.07.04-26.03-46.3- 2024.07.01-26.421.5047.252.05 2025.07.03-26.913.3847.42.37 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5ohmof priorcalibration.Thereforetheverificationresultshouldsupportextendedcalibration. <DipoleVerificationData> Head2450MHz ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. Head2600MHz Dateof Measurement ReturnLoss (dB) Delta(%)ImpedanceDelta(ohm) 2023.07.04-34.32-50.3- 2024.07.01-33.58-2.1649.61-1.37 2025.07.03-34.781.3448.94-2.71 Thereturnlossis<-20dB,within20%ofpriorcalibration;theimpedanceiswithin5ohmof priorcalibration.Thereforetheverificationresultshouldsupportextendedcalibration. <DipoleVerificationData> Head2600MHz ISSUEDBY ShenzhenSTSTestServicesCo.,Ltd. Head5000MHz Dateof Measurement ReturnLoss (dB) Delta(%)ImpedanceDelta(ohm) 2023.07.04<-8.23--- 2024.07.01-9.1010.57-- 2025.07.03-9.7017.86--- Thereturnlossis<-8dB,within20%ofpriorcalibration;Thereforetheverificationresult shouldsupportextendedcalibration. <DipoleVerificationData> Head5000MHz
Page 1 of 2 FCC ID: 2BT3Z-Y55 Setup photo AC Conduction RF Conduction Page 2 of 2 FCC ID: 2BT3Z-Y55 RE (Below 1GHz) RE (Above 1GHz)
SARSetupphotosforFCCID:2BT3Z-Y55 Frontside(separationdistanceis0mm) BackSide(separationdistanceis0mm) Leftside(separationdistanceis0mm) Topside(separationdistanceis0mm) Bottomside(separationdistanceis0mm)
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2512229W03 Issued for Shanghai Yaoyou Information Technology Co., Ltd. Room 201,South Side,1B Floor,Lianzhi Valley,No.1366,Qixin Road,Minhang District, Shanghai,China. Product Name: Android data collector Brand Name: YAOYOU Model Name: Y55 Series Model(s): Y55G, Y55pro, Y55E, Y55L, Y55S, Y55U, P8III, P8IIIH, P40, P40PRO, PCR100Y, PCR550, PDA006, RC320, RC325, A-Tab, HP-Tab, S60III, S60III Pro, MC200, MC200G, MC200pro, CS5i, CS5i Pro, HC12, T7, D5, SC280 FCC ID: 2BT3Z-Y55 Test Standards: FCC Part15.247 Page 2 of 69 Report No.: STS2512229W03 TEST REPORT Applicant’s Name ................. : Shanghai Yaoyou Information Technology Co., Ltd. Address .................................. : Room 201,South Side,1B Floor,Lianzhi Valley,No.1366,Qixin Road,Minhang District, Shanghai,China. Manufacturer's Name ........... : Shanghai Yaoyou Information Technology Co., Ltd. Address .................................. : Room 201,South Side,1B Floor,Lianzhi Valley,No.1366,Qixin Road,Minhang District, Shanghai,China. Product Description Product Name ........................ : Android data collector Brand Name ........................... : YAOYOU Model Name ........................... : ... : Y55 Series Model(s) .................... : Y55G, Y55pro, Y55E, Y55L, Y55S, Y55U, P8III, P8IIIH, P40, P40PRO, PCR100Y, PCR550, PDA006, RC320, RC325, A-Tab, HP-Tab, S60III, S60III Pro, MC200, MC200G, MC200pro, CS5i, CS5i Pro, HC12, T7, D5, SC280 Test Standards ..................... : FCC Part15.247 Test Procedure ....................... : ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the IC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item...................... : 24 Dec. 2025 Date (s) of performance of tests ............. : 24 Dec. 2025~04 Feb. 2026 Date of Issue .......................................... : 04 Feb. 2026 Test Result .............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 69 Report No.: STS2512229W03 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.6 EQUIPMENTS LIST 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 20 4.4 EUT OPERATING CONDITIONS 20 4.5 FIELD STRENGTH CALCULATION 21 4.6 TEST RESULTS 22 5. DUTY CYCLE 35 5.1 TEST STANDARD 35 5.2 TEST PROCEDURE 35 5.3 DEVIATION FROM STANDARD 35 5.4 TEST SETUP 35 5.6 TEST RESULTS 35 6. CONDUCTED SPURIOUS & BAND EDGE EMISSION 36 6.1 LIMIT 36 6.2 TEST PROCEDURE 36 6.3 TEST SETUP 36 Page 4 of 69 Report No.: STS2512229W03 Table of Contents Page 6.4 EUT OPERATION CONDITIONS 36 6.5 TEST RESULTS 36 7. POWER SPECTRAL DENSITY TEST 37 7.1 LIMIT 37 7.2 TEST PROCEDURE 37 7.3 TEST SETUP 37 7.4 EUT OPERATION CONDITIONS 37 7.5 TEST RESULTS 37 8. BANDWIDTH TEST 38 8.1 LIMIT 38 8.2 TEST PROCEDURE 38 8.3 TEST SETUP 38 8.4 EUT OPERATION CONDITIONS 38 8.5 TEST RESULTS 38 9. PEAK OUTPUT POWER TEST 39 9.1 LIMIT 39 9.2 TEST PROCEDURE 39 9.3 TEST SETUP 39 9.4 EUT OPERATION CONDITIONS 39 9.5 TEST RESULTS 39 10. ANTENNA REQUIREMENT 40 10.1 STANDARD REQUIREMENT 40 10.2 EUT ANTENNA 40 APPENDIX 1-TEST DATA 41 DUTY CYCLE 41 MAXIMUM PEAK CONDUCTED OUTPUT POWER 45 -6DB BANDWIDTH 49 MAXIMUM POWER SPECTRAL DENSITY LEVEL 53 BAND EDGE 57 CONDUCTED RF SPURIOUS EMISSION 62 APPENDIX 2- EUT TEST PHOTO 69 Page 5 of 69 Report No.: STS2512229W03 Revision History Rev. Issue Date Report No. Effect Page Contents 00 04 Feb. 2026 STS2512229W03 ALL Initial Issue Page 6 of 69 Report No.: STS2512229W03 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted bands of operation PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- Note: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 69 Report No.: STS2512229W03 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.751dB 2 Unwanted Emissions,…
Text truncated - open the document above for the full version.
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2512229W02 Issued for Shanghai Yaoyou Information Technology Co., Ltd. Room 201,South Side,1B Floor,Lianzhi Valley,No.1366,Qixin Road,Minhang District, Shanghai,China. Product Name: Android data collector Brand Name: YAOYOU Model Name: Y55 Series Model(s): Y55G, Y55pro, Y55E, Y55L, Y55S, Y55U, P8III, P8IIIH, P40, P40PRO, PCR100Y, PCR550, PDA006, RC320, RC325, A-Tab, HP-Tab, S60III, S60III Pro, MC200, MC200G, MC200pro, CS5i, CS5i Pro, HC12, T7, D5, SC280 FCC ID: 2BT3Z-Y55 Test Standards: FCC Part15.247 Page 2 of 80 Report No.: STS2512229W02 TEST REPORT Applicant’s Name ................. : Shanghai Yaoyou Information Technology Co., Ltd. Address .................................. : Room 201,South Side,1B Floor,Lianzhi Valley,No.1366,Qixin Road,Minhang District, Shanghai,China. Manufacturer's Name ........... : Shanghai Yaoyou Information Technology Co., Ltd. Address .................................. : Room 201,South Side,1B Floor,Lianzhi Valley,No.1366,Qixin Road,Minhang District, Shanghai,China. Product Description Product Name ........................ : Android data collector Brand Name ........................... : YAOYOU Model Name ........................... : Y55 Series Model(s) .................... : Y55G, Y55pro, Y55E, Y55L, Y55S, Y55U, P8III, P8IIIH, P40, P40PRO, PCR100Y, PCR550, PDA006, RC320, RC325, A-Tab, HP-Tab, S60III, S60III Pro, MC200, MC200G, MC200pro, CS5i, CS5i Pro, HC12, T7, D5, SC280 Standards ............................. : FCC Part 15.247 Test Procedure........................: ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ............................................ : Date of receipt of test item ...................... : 24 Dec. 2025 Date (s) of performance of tests ............. : 24 Dec. 2025~04 Feb. 2026 Date of Issue .......................................... : 04 Feb. 2026 Test Result .............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 80 Report No.: STS2512229W02 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 11 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 12 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 13 3. EMC EMISSION TEST 14 3.1 CONDUCTED EMISSION MEASUREMENT 14 3.2 RADIATED EMISSION MEASUREMENT 18 4. DUTY CYCLE 30 4.1 TEST STANDARD 30 4.2 TEST PROCEDURE 30 4.3 DEVIATION FROM STANDARD 30 4.4 TEST SETUP 30 4.6 TEST RESULTS 30 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 31 5.1 LIMIT 31 5.2 TEST PROCEDURE 31 5.3 DEVIATION FROM STANDARD 31 5.4 TEST SETUP 31 5.5 EUT OPERATION CONDITIONS 31 5.6 TEST RESULTS 31 6. POWER SPECTRAL DENSITY TEST 32 6.1 LIMIT 32 6.2 TEST PROCEDURE 32 6.3 DEVIATION FROM STANDARD 32 6.4 TEST SETUP 32 6.5 EUT OPERATION CONDITIONS 32 6.6 TEST RESULTS 32 Page 4 of 80 Report No.: STS2512229W02 Table of Contents Page 7. BANDWIDTH TEST 33 7.1 LIMIT 33 7.2 TEST PROCEDURE 33 7.3 DEVIATION FROM STANDARD 33 7.4 TEST SETUP 33 7.5 EUT OPERATION CONDITIONS 33 7.6 TEST RESULTS 33 8. PEAK OUTPUT POWER TEST 34 7.1 LIMIT 34 8.2 TEST PROCEDURE 34 8.3 DEVIATION FROM STANDARD 34 8.4 TEST SETUP 34 8.5 EUT OPERATION CONDITIONS 34 8.6 TEST RESULTS 34 9. ANTENNA REQUIREMENT 35 9.1 STANDARD REQUIREMENT 35 9.2 EUT ANTENNA 35 APPENDIX 1-TEST DATA 36 DUTY CYCLE 36 MAXIMUM PEAK CONDUCTED OUTPUT POWER 43 -6DB BANDWIDTH 44 MAXIMUM POWER SPECTRAL DENSITY LEVEL 51 BAND EDGE 58 CONDUCTED RF SPURIOUS EMISSION 67 APPENDIX 2-PHOTOS OF TEST SETUP 80 Page 5 of 80 Report No.: STS2512229W02 Revision History Rev. Issue Date Report No. Effect Page Contents 00 04 Feb. 2026 STS2512229W02 ALL Initial Issue Page 6 of 80 Report No.: STS2512229W02 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 80 Report No.: STS2512229W02 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.751dB 2 Unwanted Emissions, conducted ±2.888dB 3 All emissions, radiated 9K-30MHz ±2.48dB 4 All emissions, radiated 30M-1GHz ±2.52d…
Text truncated - open the document above for the full version.
Shenzhen Kuruijie Communication Technologies Co.,Ltd Antenna Test Report SHENZHEN KURUIJIE Customer:要友 Project: Y55 RF Engineer:李鑫 Testing Date:2025.04.25 Shenzhen Kuruijie Communication Technologies Co.,Ltd Index: 1. Testing Item & Equipments 2. Matching Circuits 3. Environmental Disposal 4. Test Data Shenzhen Kuruijie Communication Technologies Co.,Ltd 1: Anechoic Chamber 7x4x3 m (3D) 2: Rohde & Schwarz CMW500 3: AGILENT 8960 5515C 4: Network Analyzer-AGILENT ENA5071B 1. The Equipment of Active Test Shenzhen Kuruijie Communication Technologies Co.,Ltd 2. Matching Circuits- 位号匹配值 R205 0Ω L202 5.1NH R204 0Ω L201 1PF R201 0Ω R202 0Ω R203 NC 天线开关匹配逻辑 L202:5.1NH R204:0Ω L201;1PF R202:0Ω 逻辑软件版本:QP1A.190711.020 release-keys 开关路径位号匹配值2G3G4G RF1L2040Ω 900/1800/1900W1/2/4/8 B1/2/3/7/8/25/ 34/38/39/40/41 RF2L2064.7NH 850W5B5/20/26 RF3L20322NH B12/13/17/28A B RF4L205NC R203:NC R205:0Ω R201:0Ω Shenzhen Kuruijie Communication Technologies Co.,Ltd 三合一/分集 主板匹配未改动 三合一天线匹配 原主板匹配无修 改 WIFI天线匹配 原主板匹配无修 改 Shenzhen Kuruijie Communication Technologies Co.,Ltd 3. Environmental Disposal 主板接地 Shenzhen Kuruijie Communication Technologies Co.,Ltd 3. Environmental Disposal 喇叭贴导电泡棉与主板连接 Shenzhen Kuruijie Communication Technologies Co.,Ltd 天线增益 频段频率点最大增益平均增益 Band 1/2/3/25/39 G网1800/1900/ W1/2/4 1710-2170MHz1.6dBi0.8dBi Band5/8/20/26 G网850/900 W5/8 790-960MHz0.68dBi-1.8dBi Band12/13/17/28699-803MHz-1.3dBi-2.1dBi Band 342010-2025MHz0.8dBi0.2dBi Band 72500-2690MHz1.2dBi0.8dBi Band 402300-2400MHz1.2dBi0.8dBi Band 38/412496-2696MHz1.2dBi0.8dBi WIFI 2.4G/BT2400-2500MHz1.3dBi0.8dBi WIFI 5.8G5100-5800MHz1.3dBi0.8dBi GPS1575MHz1dBi0.5dBi Shenzhen Kuruijie Communication Technologies Co.,Ltd TestLTE1 TRPLTE2 TRPLTE3 TRPLTE5 TRPLTE7 TRPLTE8 TRP Result180501855018650191501925019900204502060020800214002150021750 Txp Ave(dBm)16.016.116.216.117.018.016.616.318.418.117.117.1 -90.4-90.3-90.6-90.5-90.2-90.5 TestLTE38 TRPLTE39 TRPLTE40 TRPLTE41 TRPLTE34 TRP Result37850381503835038550387503955040240411403625036300 Txp Ave(dBm)18.017.816.016.016.016.317.616.216.016.2 -90.1-90.0-90.1-88.5-91.0 4. Test Data TestLTE12 TRP LTE13 TRP LTE17 TRPLTE20 TRPLTE25 TRPLTE26 TRP Result2306023130232302378023800242002440026090266402674026990 Txp Ave(dBm)16.116.016.216.116.016.816.216.416.016.216.1 -90.7-90.1-90.4-90.5-90.7-90.4 TestLTE28 TRP Result27260274102746027610 Txp Ave(dBm)16.416.416.516.6 -89.2-90.1 Shenzhen Kuruijie Communication Technologies Co.,Ltd TestGSM850 TRPEGSM TRPDCS TRPPCS TRP Result1282511124512885512810 Txp Ave(dBm)25.125.326.326.224.425.124.823.7 -103.2-101.4-103.8-103.6 TestWCDMA_I TRPWCDMA_II TRPWCDMA_IV TRPWCDMA_V TRPWCDMA_VIII TRP Result9612988892629538131215134132423327122863 Txp Ave(dBm)16.416.517.716.418.318.415.515.717.117.3 -103.4-103.3-103.8-103.5-103.1 Shenzhen Kuruijie Communication Technologies Co.,Ltd GPS / WIFI WIFI2.4G(b/11m) 1611 TRP 13.615.214.3 TIS -80.4-80.7-80.3 GPS实测报告 位 置 测试结果 我司二楼 平台 冷启动60秒定位,最大CN值42.6可使用星数5颗以上. WIFI5.8G(a/54m) 36165 TRP 7.57.0 TIS -70.2-68.6 36165 12.512.8 WiFi传导 Shenzhen Kuruijie Communication Technologies Co.,Ltd BT 我司楼道可正常传输文件,直线距离≥15≤18米 Shenzhen Kuruijie Communication Technologies Co.,Ltd NFC Shenzhen Kuruijie Communication Technologies Co.,Ltd NFC Shenzhen Kuruijie Communication Technologies Co.,Ltd 匹配电路没有修改 NFC Shenzhen Kuruijie Communication Technologies Co.,Ltd 测试结果 B卡/身份证 15mm 卡4 15mm 卡2 30mm 卡30 25mm IOS 15693 50mm Shenzhen Kuruijie Communication Technologies Co.,Ltd 测试主板