FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen FEVITH Technology Co., Ltd./
  3. 2BT4O-F6

2BT4O-F6AC Charging pile

Shenzhen FEVITH Technology Co., Ltd.
AC Charging pile - FCC ID 2BT4O-F6 - Shenzhen FEVITH Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 12, 2026
Application Purpose
Original Equipment
Equipment Note
AC Charging pile
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen FEVITH Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

UserOperationManualofF6 ACChargingPile Catalogue 1、TechnicalSpecifications..........................................................................................1 2、Appearancedescription............................................................................................2 3、Descriptionoftheindicatorlightandthekeybutton...........................................3 3.1Indicatorlightdescription.................................................................................3 3.2Key s description ...............................................................................................4 4、TheWiFichargingoperationprocess......................................................................6 5、Appendix..................................................................................................................8 5.1Precautionsforuse...........................................................................................8 5.2Warrantyregulations.......................................................................................9 ACChargingPileUserManual 1 1、 TechnicalSpecifications ProductName Single-phaseSingle-phasethree-phase Ratedinput/output voltage AC220VAC220VAC220*3 Ratedinput/output current 16A32A16A Ratedoutput power 3.5KW7KW11KW Frequency 50Hz/60Hz Operatingambient temperature -30°C~+50°C Ambienthumidity5%to95%withoutcondensation Altitude Notexceeding2000meters RCD GBT:A;Type1:CCID20;Type2:A+DC6mA Protectionlevel IP55 Protectionfunction Overvoltageprotection,Undervoltageprotection,Grounding protection,Lightningprotection,Leakageprotection,Overcurrent protection,Overtemperatureprotection,Relayadhesion protection ACChargingPileUserManual 2 2、 AppearanceDescription 1input 2Workstatusdisplayarea 3touchbutton 4indicatorlight 5output 1 2 3 5 4 ACChargingPileUserManual 3 3、Descriptionoftheindicatorlightandthekeybutton 3.1Indicatorlightdescription Table3-1Lampstripspecification sequencestateChargingpilestatusLEDstatecommentsonaform 1 normal condition standby Bluelightsare oftenbright 2Readytocharge Thegreenlight isalwaysbright Theplug-ingunisnot activated 3chargingstate Thegreenlight flashing Insertguntostartstate (500mson,500msoff) 4Chargecompletestate Thegreenlight isalwaysbright Thecarisfullychargedor stopschargingwhenthe chargingiscomplete 5 Faultstate Fault state Emergencyfault Theredlightis alwaysbright Incaseoffailure,theredlight flashesonfor200msandoff for200ms 6 Ungroundedfault/LN connectionisreversed Theredlight flashestwice every5S 7CPerrorfault Theredlight flashes3times every5S 8Overcurrentfault Theredlight wasflashed4 timesevery5S 9Overvoltagefault Theredlight flashes5times every5S 10Undervoltagefault Theredlight wasflashed6 timesevery5S 11Relayadhesionfault Theredlight wasflashed7 timesevery5S 12Leakagefault Theredlight wasflashed8 timesevery5S 13Overtemperaturefailure Theredlight flashes9times every5S ACChargingPileUserManual 4 3.2Keysdescription Table3-2F8LButtonInstructions Currentsetting PressandholdtheCURRENTbuttonfor3secondstoenterthe currentsettingmode.ThecurrentLEDwillblinkduringthis time.ShortpresstheCURRENTbuttontodecreasethecurrent value,orshortpresstheTIMEbuttontoincreaseit.Pressand holdtheCURRENTbuttonagainfor3secondstoconfirmthe setting.PressandholdtheTIMEbuttonfor3secondstoexitthe currentsettingmode. Setthereservation chargingtime PressandholdtheTIMEbuttonfor3secondstoenterthe appointmentsettingmode.ThetimeLEDwillblinkduringthis process.ShortpresstheCURRENTbuttontodecreasethevalue, orshortpresstheTIMEbuttontoincreaseit.Pressandholdthe TIMEbuttonagainfor3secondstoconfirmthesetting.Press andholdtheCURRENTbuttonfor3secondstoexitthe appointmentsettingmode. ChargingStopped Duringthechargingprocess,pressandholdtheCURRENTand TIMEbuttonssimultaneouslyfor5secondstostopcharging. One-touchCancel GroundingDetection Setting PressandholdtheCURRENTbuttonfor5secondstocancel groundingdetection.ThecurrentLEDstripwillflashonandoff 3timesconsecutively. RestoreDefaultSettings PressandholdtheTIMEbuttonfor5secondstorestoredefaults (allfunctionswillbereset),andthetimeLEDstripwillflashon andoff3timesconsecutively. ACChargingPileUserManual 5 Table3-3F8ButtonInstructions Currentsetting PressandholdtheCURRENTbuttonfor3secondstoenterthe currentsettingmode.Thecurrentvaluewillflashduringthis time.ShortpresstheCURRENTbuttontodecreasethevalue,or shortpresstheTIMEbuttontoincreaseit.Pressandholdthe CURRENTbuttonagainfor3secondstoconfirmthecurrent setting. Setthereservation chargingtime PressandholdtheTIMEbuttonfor3secondstoenterthe appointmentsettingmode.Thestarttimevaluewillflashatthis time.ShortpresstheCURRENTbuttontodecreasethevalue,or shortpresstheTIMEbuttontoincreaseit.Aftersettingthestart time,pressandholdtheTIMEbuttonfor3secondsagain—at thispoint,theendtimevaluewillflash,allowingyoutosetthe endtime.Oncebothtimesareset,pressandholdtheRIGHT buttonfor3secondstoconfirmtheappointmentsettings. ChargingStopped Duringthechargingprocess,pressandholdtheCURRENTand TIMEbuttonssimultaneouslyfor5secondstostopcharging. One-touchCancel GroundingDetection Setting PressandholdtheCURRENTbuttonfor5secondstocancel groundingdetection. SettingInterface Whenthecharginggunisnotinserted,pressandholdboth buttonssimultaneouslyfor5secondstoenterthesetting interface.Bothbuttonscanbeusedforselection.Pressandhold theTIMEbuttonfor3secondstoconfirmtheoperation,and pressandholdtheCURRENTbuttonfor3secondstoexitthe settinginterface. ACChargingPileUserManual 6 4、 TheWiFichargingoperationprocess Note:Thechargingpiledoesnotsupport5GWiFinetwork,makesurethatthe WiFiis2.4Gnetwork;ThefirstconnectionrequiresBluetoothonthephoneatthe sametime.IfthechargingpileWIFIhasbeenconnectedandbound,youcanresetthe WIFIthroughthesettinginterfaceorclearthebindingbyrestoringfactorySettings Operationprocess 1.Download"Tuya"or"SmartLife"APPfrommobileappStoreorGoogleplay 2.Openthemobileapp,clickAdddeviceonthehomepage,searchforthedevice, clickAddandentertheWiFipasswordtoconnect 3.Aftertheconnectionissuccessful,tapthedevicetoaccesstheu…

Text truncated - open the document above for the full version.

External Photos

FCCID:2BT4O-F6 ExternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2BT4O-F6 Fig.3 Fig.4 FCCID:2BT4O-F6 Fig.5 Fig.6

ID Label/Location Info

FCCID:2BT4O-F6 labelandlocation Fig.1 FCCID:2BT4O-F6 ACChargingpile Model:F6 Input:AC100-265V,50/60Hz ShenzhenFEVITHTechnologyCo.,Ltd.

Internal Photos

FCCID:2BT4O-F6 InternalPhotosoftheEUT Fig.1 Fig.2 FCCID:2BT4O-F6 Fig.3 Fig.4 BT&WIFI Antenna FCCID:2BT4O-F6 Fig.5 Fig.6 FCCID:2BT4O-F6 Fig.7

RF Exposure Info

ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China RFExposureevaluation ReportReferenceNo........................: FCCID.................................................: GRCTR250903098-03 2BT4O-F6 Compiledby (position+printedname+signature) .. : TestingEngineerJimmyWang Supervisedby (position+printedname+signature)..: ProjectEngineerKelleyZhang Approvedby (position+printedname+signature)..: ManagerSamWang Dateofissue.........................................:Jan.04,2026 TestingLaboratoryName................:ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address ................................................. : 101#,BuildingK&BuildingT,TheSecondIndustrialZone, JiazitangCommunity,FenghuangStreet,GuangmingDistrict, Shenzhen,China Applicant’sname ............................... :ShenzhenFEVITHTechnologyCo.,Ltd. Address ................................................. : Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China Testspecification..............................: Standard................................................: 47CFR§2.1091 KDB447498D01v06 ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerand sourceofthematerial.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesno responsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthe reproducedmaterialduetoitsplacementandcontext. Testitemdescription........................:ACChargingpile TradeMark............................................: / Manufacturer.........................................: ShenzhenFEVITHTechnologyCo.,Ltd. Model/Typereference.........................: F6 ListedModels......................................: F3,F3L,F5,F5L,F6L,F8,F8L,F9,F9L,L5,L5L,L6,L6L,L8,L8L,L9,L9L,H 5,H6,H7,H8,H9,P5,P6,P7,P8,P9 HardwareVersion...............................:V1.0 SoftwareVersion..................................:V1.0 Frequency..............................................From2402MHzto2480MHz Ratings...................................................:AC100-265V,50/60Hz Result ..................................................... :PASS ReportNo.:GRCTR250903098-03Page2of9 TESTREPORT EquipmentunderTest:ACChargingpile Model/Type:F6 ListedModels:F3,F3L,F5,F5L,F6L,F8,F8L,F9,F9L,L5,L5L,L6,L6L,L8,L8L,L9,L 9L,H5,H6,H7,H8,H9,P5,P6,P7,P8,P9 Applicant : ShenzhenFEVITHTechnologyCo.,Ltd. Address: Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China Manufacturer : ShenzhenFEVITHTechnologyCo.,Ltd. Address: Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China TestResult : PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR250903098-03Page3of9 Contents 1.SUMMARY...............................................................................................................................................4 1.1.GeneralRemarks.........................................................................................................................................4 1.2.ProductDescription....................................................................................................................................4 1.3.EquipmentUnderTest................................................................................................................................5 1.4.ShortdescriptionoftheEquipmentunderTest(EUT)............................................................................5 1.5.EUTconfiguration........................................................................................................................................5 1.6.Modifications................................................................................................................................................5 2.TESTENVIRONMENT.......................................................................................................................6 2.1.Addressofthetestlaboratory...................................................................................................................6 2.2.TestFacility..................................................................................................................................................6 2.3.Environmentalconditions...........................................................................................................................6 2.4.Statementofthemeasurementuncertainty.............................................................................................6 3.METHODOFMEASUREMENT.....................................................................................................8 3.1.ApplicableStandard....................................................................................................................................8 3.2.Limit...............................................................................................................................................................8 3.3.MPECalculationMethod.............................................................................................................................8 3.4.AntennaInformation....................................................................................................................................9 3.5.ManufacturingTolerance............................................................................................................................9 4.E…

Text truncated - open the document above for the full version.

Test Report

Antennaspec FCCID:2BT4O-F6 1.AntennaDescription: AntennatypePCBAntenna ModelWBR3 Frequencyrange2400MHz~2500MHz ManufacturerHangzhouTuyaInformationTechnologyCo.,Ltd AddressRoom701,Building3,MoreCenter,No.87GuDun Road.Hangzhou,Zhejiang,China 2.AntennaPhoto: Unit:mm 3.AntennaEfficiencyandGain: 4.2DRadiationPattern 5.3DRadiationPattern

Test Report

ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China FCCPART15SUBPARTCTESTREPORT FCCPART15.247 ReportReferenceNo........................: FCCID.................................................: GRCTR250903098-01 2BT4O-F6 Compiledby (position+printedname+signature) .. : TestingEngineerJimmyWang Supervisedby (position+printedname+signature)..: ProjectEngineerKelleyZhang Approvedby (position+printedname+signature)..: ManagerSamWang Dateofissue.........................................:Jan.04,2026 TestingLaboratoryName................: ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address ................................................. : 101#,BuildingK&BuildingT,TheSecondIndustrialZone,Jiazitang Community,FenghuangStreet,GuangmingDistrict,Shenzhen, China Applicant’sname...............................: ShenzhenFEVITHTechnologyCo.,Ltd. Address.................................................: Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China Testspecification .............................. : Standard................................................:FCCPart15.247 ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerand sourceofthematerial.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesno responsibilityforandwillnotassumeliabilityfordamagesresultingfromthereader'sinterpretationofthe reproducedmaterialduetoitsplacementandcontext. Testitemdescription ........................ : ACChargingpile TradeMark ............................................ : / Manufacturer.........................................: ShenzhenFEVITHTechnologyCo.,Ltd. Model/Typereference ......................... : F6 ListedModels ...................................... : F3,F3L,F5,F5L,F6L,F8,F8L,F9,F9L,L5,L5L,L6,L6L,L8,L8L,L9,L9L,H5 ,H6,H7,H8,H9,P5,P6,P7,P8,P9 FirmwareVersion ................................. :V1.0 HardwareVersion................................:V1.0 Modulation ........................................... : GFSK Frequency.............................................. From2402MHzto2480MHz Ratings ................................................... : AC100-265V,50/60Hz Result.....................................................: PASS ReportNo.:GRCTR250903098-01Page 2 of 35 TESTREPORT EquipmentunderTest:ACChargingpile Model/Type:F6 ListedModels:F3,F3L,F5,F5L,F6L,F8,F8L,F9,F9L,L5,L5L,L6,L6L,L8,L8L,L9,L9L, H5,H6,H7,H8,H9,P5,P6,P7,P8,P9 Applicant : ShenzhenFEVITHTechnologyCo.,Ltd. Address: Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China Manufacturer : ShenzhenFEVITHTechnologyCo.,Ltd. Address: Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China TestResult:PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR250903098-01Page 3 of 35 Contents 1TESTSTANDARDS..............................................................................................................................4 2SUMMARY.................................................................................................................................................5 2.1GeneralRemarks..........................................................................................................................................5 2.2ProductDescription.....................................................................................................................................5 2.3EquipmentUnderTest.................................................................................................................................5 2.4ShortdescriptionoftheEquipmentunderTest(EUT).............................................................................5 2.5EUTconfiguration.........................................................................................................................................5 2.6EUToperationmode.....................................................................................................................................6 2.7BlockDiagramofTestSetup.......................................................................................................................6 2.8RelatedSubmittal(s)/Grant(s)...................................................................................................................6 2.9Modifications.................................................................................................................................................6 3TESTENVIRONMENT........................................................................................................................7 3.1Addressofthetestlaboratory....................................................................................................................7 3.2TestFacility...................................................................................................................................................7 3.3Environmentalconditions............................................................................................................................7 3.4Summaryofmeasurementresults..............................................................................................................8 3.5Statementofthemeasurementuncertainty..............................................................................................8 3.6EquipmentsUsedduringtheTest.............................................................…

Text truncated - open the document above for the full version.

Test Report

ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. 101#,BuildingK&BuildingT,TheSecondIndustrialZone,JiazitangCommunity, FenghuangStreet,GuangmingDistrict,Shenzhen,China FCCPART15SUBPARTCTESTREPORT FCCPART15.247 ReportReferenceNo. ....................... : FCCID.................................................: GRCTR250903098-02 2BT4O-F6 Compiledby (position+printedname+signature)..: TestingEngineerJimmyWang Supervisedby (position+printedname+signature) .. : ProjectEngineerKelleyZhang Approvedby (position+printedname+signature)..: ManagerSamWang Dateofissue ......................................... :Jan.04,2026 TestingLaboratoryName ................ :ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd. Address.................................................: 101#,BuildingK&BuildingT,TheSecondIndustrialZone,Jiazitang Community,FenghuangStreet,GuangmingDistrict,Shenzhen,China Applicant’sname...............................:ShenzhenFEVITHTechnologyCo.,Ltd. Address ................................................. : Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China Testspecification..............................: Standard ................................................ :FCCPart15.247 ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheShenzhen GUORENCertificationTechnologyServiceCo.,Ltd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenGUORENCertificationTechnologyServiceCo.,Ltd.takesnoresponsibilityforandwill notassumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. Testitemdescription........................:ACChargingpile TradeMark............................................: / Manufacturer ......................................... : ShenzhenFEVITHTechnologyCo.,Ltd. Model/Typereference ......................... : F6 ListedModels......................................: F3,F3L,F5,F5L,F6L,F8,F8L,F9,F9L,L5,L5L,L6,L6L,L8,L8L,L9,L9L,H5, H6,H7,H8,H9,P5,P6,P7,P8,P9 FirmwareVersion.................................:V1.0 HardwareVersion................................:V1.0 ModulationType .................................. :DSSS/OFDM OperationFrequency .......................... :From2412-2462MHz Rating.....................................................:AC100-265V,50/60Hz Result.....................................................:PASS ReportNo.:GRCTR250903098-02Page 2 of 36 TESTREPORT EquipmentunderTest:ACChargingpile Model/Type:F6 ListedModels: F3,F3L,F5,F5L,F6L,F8,F8L,F9,F9L,L5,L5L,L6,L6L,L8,L8L,L9,L9L, H5,H6,H7,H8,H9,P5,P6,P7,P8,P9 Applicant : ShenzhenFEVITHTechnologyCo.,Ltd. Address: Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China Manufacturer : ShenzhenFEVITHTechnologyCo.,Ltd. Address: Room401,Building5,NantaiCloudInnovationValley,No.759 TongyeRd.,TangweiCommunity,FenghuangSub-district, GuangmingDist.,Shenzhen,Guangdong,P.R.China TestResult : PASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. ReportNo.:GRCTR250903098-02Page 3 of 36 Contents 1TESTSTANDARDS..............................................................................................................................4 2SUMMARY.................................................................................................................................................5 2.1GeneralRemarks..........................................................................................................................................5 2.2ProductDescription.....................................................................................................................................5 2.3ShortdescriptionoftheEquipmentunderTest(EUT).............................................................................5 2.4EquipmentUnderTest.................................................................................................................................5 2.5EUTconfiguration.........................................................................................................................................6 2.6EUToperationmode.....................................................................................................................................6 2.7BlockDiagramofTestSetup.......................................................................................................................6 2.8RelatedSubmittal(s)/Grant(s)...................................................................................................................6 2.9Modifications.................................................................................................................................................6 3TESTENVIRONMENT........................................................................................................................7 3.1Addressofthetestlaboratory....................................................................................................................7 3.2TestFacility...................................................................................................................................................7 3.3Environmentalconditions............................................................................................................................7 3.4TestDescription............................................................................................................................................7 3.5Statementofthemeasurementuncertainty..............................................................................................8 3.6EquipmentsUsedduringtheTest.............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BT4O-F6 TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 FCCID:2BT4O-F6 TestSetupPhoto(s)ofConductedEmissionsMeasurement Fig.3 TestSetupPhoto(s)ofRFMeasurement Fig.4

Contact Information

Applicant

Ma Ke(Manager)
[email protected]Fax: 0755-23408306

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place, Fullerton, · China

Test Firm

Shenzhen GUOREN Certification Technology Service CSam Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.30 mW
215C2.41 GHz - 2.46 GHz31.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.