2BTCMYCL-ACW01AC EV Charger

Shenzhen Yuanchuangli Electronic Co., Ltd.
AC EV Charger - FCC ID 2BTCMYCL-ACW01 - Shenzhen Yuanchuangli Electronic Co., Ltd.
Click to zoom

Application Details

Equipment Class
JAD - Part 15 Class A Digital Device
Date of Grant
Dec 11, 2025
Application Purpose
Original Equipment
Equipment Note
AC EV Charger
Company
Shenzhen Yuanchuangli Electronic Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USERMANUAL ACEVCHARGER InstallationandoperationguideV.1.1 1. 2. 2 1.Forewords Thankyouforpurchasingourhomechargingpile.Thisproductisspeciallydesignedforelectricvehicleusers, providingasafeandconvenientchargingsolution. Theproductadoptsa32-bitcontrolsystem,integratingintelligentcontrolfunctionssuchaschargingcontrol, overcurrentdetection,andovervoltagedetection. Thechargingdeviceiseasytoinstallandoperate.Itallowscharginganytimeandanywhereaslongasthereis anACpowersupply. 1.1ProductFeatures •Compatiblewithmostelectricvehiclemodels •Fastchargingcapabilitytoshortenchargingtime •Intelligentchargingmanagementtopreventovercharging •Waterproofdesignsuitableforindoorandoutdoorinstallation •IntuitiveLCDdisplayorLEDstatusindicator •Remotemonitoringandcontrolfunctions(requiresAPPsupport) 2.Importantnotices Beforeinstallationandcommissioning. Observeallsafetyregulationsandinstructionsinthismanual! Readthemanualandthedatasheetcarefullyandkeepthemforfuturereference.Thedocumentsareintendedto helpyou: •Tousetheproductsafelyandproperly •Increasethedurabilityandreliability •Toavoiddamagetothedeviceorproperty •Topreventathreattolifeandlimb SafetyInstructions: •Thefollowinginstructionsareveryimportant.Pleasereadthemcarefullytoensuresafety! •Thechargingstationmustbekeptawayfromwater,fire,smoke,hazardousgases,etc. •Thechargingstationshouldbeinstalledvertically,withaninclinationofnomorethan5°fromthevertical. •Beforeuse,ensurethatthechargingstationisreliablygrounded. •Whenthechargingstationispoweredon,operatorsmustmaintainasafedistancefromthechargingstation. •Whenunpluggingthechargingcable,becarefulnottouseexcessiveforce.Donotunplugorremovethe chargingcableviolently. •Donotunplugthechargingplugwhilethesystemisoperating. •Donotpresstheemergencybuttonunlessabsolutelynecessary. •Ifanyabnormalsound,vibration,sparks,smoke,orotherserioussymptomsoccurduringoperation,pressthe emergencybuttonimmediately. •Electricshockcanbefatal.Donotplugintothesocketorplugsystembyhandorwiththehelpoftechnical aids. •Installationandmaintenancemustbecarriedoutbyaqualifiedelectricianorspecialistpersonnel. Attention:Disregardingthesecuritynoticecanhaveseriousconsequences.Thecompanydeclinesanyliability fordamagecausedbydisregardingtheoperatinginstructions,orwarningsontheunit. Dailychecks : •Promptlycleanthechargerasneeded,includingtheexterior,cables,andchargingplugs,focusingonchecking forcrackedordamagedcables. 3 •Everyyearrequiredtocheckwhethertheterminalsandwiringcablesareinsulatedandsturdy;testthe contactorandrelaycontactsandcontactforceoftheaction,whetherthejumpercapsolderpinsofthecircuit boardarelooseandwhetherthecomponentsaresturdy;pressthecircuitbreakerleakagetestbuttonofthe chargingpile,whetherthecircuitbreakercanautomaticallydisconnect;testtheemergencybutton;check whetherthecontrolfunctionandstateswitchingofeachmodulearecorrect. Wheninspectingequipmentonadailycheck,focusonthefollowingsections: (1)Observetheappearanceforintegrity,ensurenocracks,nodeformation,noelectricshockscorch. (2)Slightlyshakethechargertoseeifitisfixedstablyandwithoutlooseness. (3)Duringcharging,lightlytouchtheboxtomakesurewhetherthesurfaceofthechargingpileisover-heated. 3.Productoverview Technicaldata TheEVchargerisdesigned,produced,andtestedinstrictcompliancewithrelevantEuropeanstandards (IEC61851-1,IEC61851-21,IEC61000,andROHSdirective).Itisequippedwithreliableelectricalprotection, andmoisture-proof,dust-proof,waterproof,anti-mildew,anti-saltsprayandotherfunctions. 4.Installationinstruction Package list: AC EV Charger × 1 Gun Holder × 1 Wall-mounted Bracket (including screws) User Manual × 1 7KW11KW22KW Displayscreen:4.3-inchLCDscreen4.3-inchLCDscreen4.3-inchLCDscreen Chargingplug:GBT/Type1/Type2/TeslaGBT/Type1/Type2/TeslaGBT/Type1/Type2/Tesla Powersupply:1P+N+PE3P+N+PE3P+N+PE Ratedinput/output:230VAC400VAC400VAC Ratedpower:7KW11KW22KW RCDbuilt-in:30mATypeA30mATypeA+6mADC30mATypeA+6mADC Over/underVoltage:230VAC400VAC400VAC OverTemperature:85°C85°C85°C RatedFrequency:50/60Hz50/60Hz50/60Hz RatedCurrent:8A/10A/13A/16A/32A8A/10A/13A/16A8A/10A/13A/16A/32A OperatingTemperature:-30°C~+50°C-30°C~+50°C-30°C~+50°C StorageTemperature-30~+60°C-30~+60°C-30~+60°C IPDegreeofProtectionIP55IP55IP55 Netweight:3.5kg3.5kg3.5kg 4 Prepare When transporting or moving the charging station, pay attention to the following points to ensure product safety: This product is electrical equipment. It should be handled with care to avoid violent vibration and impact. The LCD screen part cannot be used as a stressed part for handling. The charging station shall not be transported by dragging the charging connector and its charging cable. In order to ensure the long-term stable operation of the product, it is recommended to avoid installing charging stations in extreme weather as far as possible, especially low or high ambient temperature may affect the installation effect due to thermal expansion and cold contraction. It is suggested that the charging station should be installed in a place with good ventilation, no direct sunlight and shelter from wind and rain. Please avoid to be installed around wet place, like pool, water tap, etc. If must, its clear distance must be more than 2 meters far from the wet place. Installation steps A. Confirm the installation position with users. For wall mounting, the charging station should be mounted vertically and leave enough space. The recommended minimum space requirements are shown below: B. Mark the four mounting holes with a pencil, based on below hole’s position or with the reference of wall mounting plate/post. Wall-mounted C.Drillfourholesatthemarkedpositions. UseØ8drillbittodrill4holesof8mmborediameterand45mmdepth.HammertheM8*40mmplastic expansionboltintothewallholes. D.Fixthemountingplate/postandsecurethechargingstation. Usethescrewdrivertofixtheself-tappingscrewstothemountingplateonthewall,thensecurethecharging stationtotheplate,andlockthechargingstationandmountingplatewithascrewonbottom. E.Installthehanginghook Placethehanginghookinanappropriatepo…

Text truncated - open the document above for the full version.

Attestation Statements

Rev1/26/2023 ShenzhenYuanchuangliElectronicCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:December11,2025 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BTCMYCL-ACW01 [ShenzhenYuanchuangliElectronicCo.,Ltd.]certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. [ShenzhenYuanchuangliElectronicCo.,Ltd.]certifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, ContactName:Joshzhang Rev1/26/2023 ShenzhenYuanchuangliElectronicCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:eDecember11,2025 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BTCMYCL-ACW01 [ShenzhenYuanchuangliElectronicCo.,Ltd.]certifiesthat,asofthedateofthefilingoftheapplication, theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofitssubsidiaries oraffiliates)asanentityproducing“covered”equipment. Sincerely, ContactName:Joshzhang

Attestation Statements

ShenzhenYuanchuangliElectronicCo.,Ltd. Address:4thFloor,BuildingD,XinxiongIndustrialPark,Bao'anDistrict,ShenzhenCity, China FRN:0037683828 Date:2025-12-02 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BTCMYCL-ACW01 (“ShenzhenYuanchuangliElectronicCo.,Ltd”)certifiesthat,asofthedateofthefilingofthe application,(PlethyInc.)isourdesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID.(“2BTCMYCL-ACW01”)acceptstomaintainanagentforno lessthanoneyearafterthegranteehasterminatedallmarketingandimportationorthe conclusionofanyCommission-relatedproceedinginvolvingtheequipment. (PlethyInc.)accepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:PlethyInc FRN:0035219609 Address:2362QumeDr,Suite#DSanJose,CA95131UnitedStates ContactPerson:RajaSundaram/CEO Tel.:(408)607-7646 Email:[email protected] Sincerely, ShenzhenYuanchuangliElectronicCo.,Ltd PlethyInc Name:Joshzhang Name:RajaSundaram Title:SalesManagerTitle:CEO Date:2025-12-09Date:2025-12-09

Cover Letter(s)

ShenzhenYuanchuangliElectronicCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:December10,2025 Subject;RequestforConfidentiality FCCID:2BTCMYCL-ACW01 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram OperationalDescription Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:Joshzhang Title:SalesManager

Cover Letter(s)

EffectiveDate:April2,2020QSF7.6.4-8–AgentAuthorizationLetterTemplatePage1of1 RevisionDate:Revision:0 ShenzhenYuanchuangliElectronicCo.,Ltd. Date:2025.12.09 ProductModelNumber:YCL-ACW01 FCCID:2BTCMYCL-ACW01 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C.CanadaV5J5K5to actonourbehalfonallmattersconcerningtheabovenamedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformationrelatedtothe approvalprojecttotheappliedcertificationbodyandtothenotificationentitiesandtodiscuss anyissuesconcerningtheapprovalapplication.AnyandallactscarriedoutbyQAILaboratories Ltd.onourbehalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:legalperson Email:[email protected] Telephone:+8613826525914 Onbehalfof:ShenzhenYuanchuangliElectronicCo.,Ltd.

Cover Letter(s)

ShenzhenYuanchuangliElectronicCo.,Ltd. To:QAILABORATORIESLTD. DECLARATIONOFIDENTITY Herebywe: ShenzhenYuanchuangliElectronicCo.,Ltd. (NameofManufacturer) FCCID:2BTCMYCL-ACW01 BasicModelNumber:YCL-ACW01 BasicBrandName:/ BasicProductName:ACEVCharger BasicTestReportApplication Number:DL-202511230198E DeclaretheCircuit,PCBLayout;ElectricalPartsandOutlookofthefollowing product(s)areidenticaltothebasicmodel:  New/☑AdditionalModelNumber(s):YCL-ACW(01~10) □New/□AdditionalBrandName(s): □New/□AdditionalProductName(s): Exceptthefollowing(s):Note:PCBboard,structureandinternalofthese model(s)arethesame,Justdifferentmodelnames Remarks: SignaturewithCompanyChop: PrintedName:Joshzhang DATE:2025.12.09

External Photos

FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01

ID Label/Location Info

FCCID:2BTCMYCL-ACW01 LabelLocation Length:120mm Width:50mm

Internal Photos

FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 Antenna FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01 FCCID:2BTCMYCL-ACW01

Test Report

ShenzhenDLTestingTechnologyCo.,Ltd.ReportNo.:DL-202511230198E TestReportTel:400-688-3552Web:www.dl-cert.comEmail:[email protected] 1 of 20 FCCPart15BTestReport FCCID:2BTCM YCL-ACW01 Applicant:ShenzhenYuanchuangliElectronicCo.,Ltd. Address:4thFloor,BuildingD,XinxiongIndustrialPark,Bao'anDistrict,ShenzhenCity,China Manufacturer:ShenzhenYuanchuangliElectronicCo.,Ltd. Address:4thFloor,BuildingD,XinxiongIndustrialPark,Bao'anDistrict,ShenzhenCity,China EUT:ACEVCharger TradeMark:N/A ModelNumber:YCL-ACW01,YCL-ACW(01~10) DateofReceipt:Nov.01,2025 TestDate:Nov.01,2025-Nov.18,2025 DateofReport:Nov.18,2025 PreparedBy:ShenzhenDLTestingTechnologyCo.,Ltd. Address: 101-201,BuildingC,Shuanghuan,No.8,BaoqingRoad,BaolongIndustrialZone, BaolongStreet,LonggangDistrict,Shenzhen,Guangdong,China Applicable Standards: FCC47CFRPart15SubpartB:2022 ANSIC63.4:2014 TestResult:Pass ReportNumber:DL-202511230198E Prepared(TestEngineer):AlisaSong Reviewer(Supervisor):JackBu Approved(Manager):JadeYang Thistestreportisbasedonasingleevaluationofonesampleofabovementionedproducts.Itisnotpermittedto beduplicatedinextractswithoutwrittenapprovalofShenzhenDLTestingTechnologyCo.,Ltd. ShenzhenDLTestingTechnologyCo.,Ltd.ReportNo.:DL-202511230198E TestReportTel:400-688-3552Web:www.dl-cert.comEmail:[email protected] 2 of 20 TableofContentsPage 1.SUMMARYOFTESTRESULTS...............................................................................3 1.1MEASUREMENTUNCERTAINTY....................................................................................3 1.2TESTFACILTY..................................................................................................................3 2.GENERALINFORMATION........................................................................................4 2.1GENERALDESCRIPTIONOFEUT.................................................................................4 2.2DESCRIPTIONOFTESTMODE......................................................................................4 2.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED..............4 2.4DESCRIPTIONOFSUPPORTUNITS..............................................................................5 2.5EQUIPMENTSLISTFORALLTESTITEMS...................................................................6 3.POWERLINECONDUCTEDEMISSIONTEST........................................................7 3.1CONDUCTEDEMISSIONLimits(FREQUENCYRANGE150KHZ-30MHZ).................7 3.2TESTPROCEDURE..........................................................................................................7 3.3DEVIATIONFROMTESTSTANDARD.............................................................................7 3.4TESTSETUP.....................................................................................................................8 3.5EUTOPERATINGCONDITIONS......................................................................................8 3.6TESTRESULTS.................................................................................................................8 4.RADIATEDEMISSIONTEST.................................................................................11 4.1RADIATEDEMISSIONLIMITS(FREQUENCYRANGE9KHZ-1000MHZ)...................11 4.2TESTPROCEDURE........................................................................................................12 4.3DEVIATIONFROMTESTSTANDARD...........................................................................13 4.4TESTSETUP...................................................................................................................13 4.5EUTOPERATINGCONDITIONS....................................................................................14 4.6TESTRESULTS..............................................................................................................14 5.TESTSEUUPPHOTO..............................................................................................19 ShenzhenDLTestingTechnologyCo.,Ltd.ReportNo.:DL-202511230198E TestReportTel:400-688-3552Web:www.dl-cert.comEmail:[email protected] 3 of 20 1.SUMMARYOFTESTRESULTS Testproceduresaccordingtothetechnicalstandards: FCCPart15SubpartB Standard Section TestItemJudgmentRemark §15.107PowerLineConductedEmissionTestPASS §15.109 RadiatedEmissionTest(Below1GHz) PASS §15.109 RadiatedEmissionTest(Above1GHz) PASS NOTE: (1)”N/A”denotestestisnotapplicableinthisTestReport 1.1MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±U,whereexpendeduncertaintyUisbasedonastandard uncertaintymultipliedbyacoveragefactorofk=2,providingalevelofconfidenceofapproximately95%。 No.ItemUncertainty 1ConductedEmissionTest±2.56dB 2Allemissions,radiated(<1G)±3.65dB 3Allemissions,radiated(>1G)±4.89dB 4Temperature±0.5°C 5Humidity±2% 1.2TESTFACILTY ShenzhenDLTestingTechnologyCo.,Ltd. Add.:101-201,BuildingC,Shuanghuan,No.8,BaoqingRoad,BaolongIndustrialZone, BaolongStreet,LonggangDistrict,Shenzhen,Guangdong,China FCCTestFirmRegistrationNumber:854456 DesignationNumber:CN1307 ICRegistteredNo.:CN0118 ShenzhenDLTestingTechnologyCo.,Ltd.ReportNo.:DL-202511230198E TestReportTel:400-688-3552Web:www.dl-cert.comEmail:[email protected] 4 of 20 2.GENERALINFORMATION 2.1GENERALDESCRIPTIONOFEUT ProductName:ACEVCharger Trademark:N/A ModelNo.:YCL-ACW01 ModelDifference: YCL-ACW(01~10) Allmodelshavesamecircuitsdiagram,PCBLayout,constructionandrated power,onlydifferentisthemodelname. SampleNo.:DL-202511230198# PowerSupply: RatedInput:120V1240VAC,50160Hz,6A-40A RatedOutput:120V1240VAC,50/60Hz,6A-40A Note: 1.Foramoredetailedfeaturesdescription,pleaserefertothemanufacturer’sspecificationsortheUser's Manual. 2.TheEUT’sallinformationprovidedbyclient. 2.2DESCRIPTIONOFTESTMODE 2.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED ForMode1BlockDiagramofTestSetup PretestModeDescription Mode1On(Theproductisworkingnormally) ACMains EUT Output ShenzhenDLTestingTechnologyCo.,Ltd.ReportNo.:DL-202511230198E TestReportTel:400-688-3552Web:www.dl-cert.comEmail:[email protected] 5 of 2…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BTCMYCL-ACW01 RadiatedEmission(Below1G) RadiatedEmission(Above1G) FCCID:2BTCMYCL-ACW01 ConductedMeasurementPhotos

Contact Information

Applicant

Josh zhang
[email protected]Fax: 13826525914

Technical Contact

Plethy Inc
[email protected]

United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--
Confidentiality
Long Term