FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Intelligent Locations/
  3. 2BTDPILATBC300

2BTDPILATBC300Asset Beacon

Intelligent Locations
Asset Beacon - FCC ID 2BTDPILATBC300 - Intelligent Locations
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 23, 2026
Application Purpose
Original Equipment
Equipment Note
Asset Beacon
Frequency Range
2402.00000000 - 2480.00000000
Company
Intelligent Locations
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Intelligent Locations Asset Beacon (ILA-TBC300) User Manual Introduction: Intelligent Locations’ asset beacons are quarter-sized wireless devices that broadcast signals using our Bluetooth Low Energy (BLE) technology. The asset beacons can be used to track hospital equipment in real-time to reduce find times, maximize utilization rates, and manage inventory and resources more efficiently. Small beacon using BLE technology with up to 3.5 years of battery life on a single coin cell battery. The beacon contains and ST Micro accelerometer which also features a temperature sensor. BLE advertisement packets broadcast data for Intelligent Locations systems to decipher. The beacon has two states: Active: the beacon is in motion, 1 second advertising interval. Inactive: the beacon is idle, 7.5 second advertising interval. The specifications for the asset beacon are as follows: PERFORMANCE ⎯ 32 –bit ARM ® Cortex®–M3 with 76.8 MHz ⎯ Bluetooth LE 5.2 (direction finding) POWER ⎯ 3v CR2032 Coin Cell Battery (non-serviceable) ⎯ Expected Lifetime Approximately 3 yrs(configuration-dependent) PHYSICAL DIMENSIONS L ⎯ 1.34 in(34.04mm) W⎯ 1.25 in(31.75mm) H ⎯ 0.25 in(6.35mm) The asset beacons are shipped in bulk to a customer site location. The Intelligent Locations Account team is responsible for installing these beacons. Additional Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Class B: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radi-ate radio frequency energy and, if not in- stalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/ TV technician for help.

Attestation Statements

2025-12- 08 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID : 2BTDPILATBC300 [Intelligent Locations] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Signature: Name:Daniel Mogin 2025-12-08 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID : 2BTDPILATBC300 Intelligent Locations certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Signature: Name: Daniel Mogin

Attestation Statements

U.S. Agent Designation for Service of Process (Applicant and U.S. Agent are Separate Parties) ATTENTION: FCC Certification – Section 2.911(d)(7) Information Designated U.S. Agent Company Name: Intelligent Locations Address: 8601 Six Forks Rd., Suite 205, Raleig, North Carolina, 27615-5236, United States FRN: 0037688892 Contact Name: Bogdan Nedelcu Telephone No: (847) 809-7172 Email: [email protected] This letter is to confirm that we (“the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: Intelligent Locations FRN: 0037688892 Grantee Code: 2BTDP FCC ID: 2BTDPILATBC300 Contact Name: Bogdan Nedelcu Address: 8601 Six Forks Rd., Suite 205, Raleig, North Carolina, 27615-5236, United States Telephone No: (847) 809-7172 Email: [email protected] Signature: Date: 2025-12-08 Signed by (Printed Name/Title): Daniel Mogin

Cover Letter(s)

Date: 2025-12-08 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR ( Asset Beacon / ILA-TBC300 / FCC ID: 2BTDPILATBC300) To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the ( Block Diagrams, Schematics, Operational Descriptions) required to be submitted with this application be permanently withheld from public review. The above documents are company proprietary information that could never get into the possession of your competition. Please contact me if there is any information you may need. Sincerely, Signature: Name: Daniel Mogin Applicant: Intelligent Locations Address: 8601 Six Forks Rd., Suite 205, Raleig, North Carolina, 27615-5236, United States

Cover Letter(s)

Date: 2026-04-20 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Daniel Mogin to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Signature: Name: Bogdan Nedelcu Applicant: Intelligent Locations Address: 8601 Six Forks Rd., Suite 205, Raleig, North Carolina, 27615-5236, United States

RF Exposure Info

Radio frequency radiation exposure evaluation: portable devices RESULT : Pass Test Specification Test item : Asset Beacon Identification / Type No. : ILA-TBC300 FCC ID : 2BTDPILATBC300 Test standard : CFR47 FCC Part 2: Section 2.1093 FCC KDB Publication 447498 D04 Measurement Record: Since maximum peak output power of the transmitter is -12.67dBm ≈ 0.054mW < 3 mW. Hence the EUT is excluded from SAR evaluation according to FCC KDB Publication 447498 D04

Test Report

Appendix A: DTS Bandwidth Test Result TestMode Antenna Frequency[MHz] DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.640 2401.700 2402.340 0.5 PASS 2440 0.644 2439.696 2440.340 0.5 PASS 2480 0.628 2479.704 2480.332 0.5 PASS Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0540 2401.5010 2402.5550 --- --- 2440 1.0593 2439.5009 2440.5602 --- --- 2480 1.0556 2479.5011 2480.5567 --- --- Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Appendix C: Maximum conducted output power Test Result Peak TestMode Antenna Frequency[MHz] Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -12.95 ≤30 PASS 2440 -13.36 ≤30 PASS 2480 -12.67 ≤30 PASS Test Graphs Peak BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Appendix D: Maximum power spectral density Test Result TestMode Antenna Frequency[MHz] Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -16.48 ≤8.00 PASS 2440 -16.69 ≤8.00 PASS 2480 -15.79 ≤8.00 PASS Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Appendix E: Band edge measurements Test Result TestMode Antenna ChName Frequency [MHz] RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 -15.45 -46.64 ≤-35.45 PASS High 2480 -14.73 -47.14 ≤-34.73 PASS Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Frequency [MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -15.71 -15.71 --- PASS 30~1000 -15.71 -58.1 ≤-35.71 PASS 1000~26500 -15.71 -50.73 ≤-35.71 PASS 2440 Reference -15.84 -15.84 --- PASS 30~1000 -15.84 -58.4 ≤-35.84 PASS 1000~26500 -15.84 -50.69 ≤-35.84 PASS 2480 Reference -14.96 -14.96 --- PASS 30~1000 -14.96 -58.89 ≤-34.96 PASS 1000~26500 -14.96 -46.02 ≤-34.96 PASS Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 BLE_1M_Ant1_2480_1000~26500 Appendix G: Duty Cycle Test Result TestMode Antenna Frequency[MHz] ON Time [ms] Period [ms] Duty Cycle [%] BLE_1M Ant1 2402 0.40 0.63 63.49 2440 0.40 0.63 63.49 2480 0.40 0.63 63.49 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 Appendix H: Restricted Band Mode: 1M Channel: 2402MHz Test Graph Suspected Data List NO. Frequency [MHz] Reading [dBμV/m] Level [dBμV/m] Factor [dB] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Det Polarity Verdict 1 2310.0000 39.86 46.82 6.96 74.00 27.18 150 64 PK Horizontal PASS 2 2323.6000 40.71 47.87 7.16 74.00 26.13 150 151 PK Horizontal PASS 3 2337.1200 41.60 48.69 7.09 74.00 25.31 150 78 PK Horizontal PASS 4 2351.4400 41.48 48.84 7.36 74.00 25.16 150 140 PK Horizontal PASS 5 2369.2000 40.75 48.28 7.53 74.00 25.72 150 126 PK Horizontal PASS 6 2390.0000 40.96 49.24 8.28 74.00 24.76 150 306 PK Horizontal PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level Mode: 1M Channel: 2402MHz Test Graph Suspected Data List NO. Frequency [MHz] Reading [dBμV/m] Level [dBμV/m] Factor [dB] Limit [dBμV/m] Margin [dB] Height [cm] Angle [°] Det Polarity Verdict 1 2310.0000 39.80 46.76 6.96 74.00 27.24 150 151 PK Vertical PASS 2 2318.5600 42.05 49.20 7.15 74.00 24.80 150 147 PK Vertical PASS 3 2338.0800 41.89 49.00 7.11 74.00 25.00 150 342 PK Vertical PASS 4 2357.6800 40.92 48.24 7.32 74.00 25.76 150 289 PK Vertical PASS 5 2368.9600 42.48 50.00 7.52 74.00 24.00 150 104 PK Vertical PASS 6 2390.0000 40.01 48.29 8.28 74.00 25.71 150 87 PK Vertical PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level Mode: 1M Channel: 2480MHz Test Graph Final Data List NO. Frequency [MHz] Factor [dB] PK Reading [dBμV/ m] PK Value [dBμV/m] PK Limit [dBμV/m] PK Margin [dB] AV Reading [dBμV/ m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Height [cm] Angle [°] Polarity Verdict 1 2483.5000 7.53 49.6 57.13 74.00 16.87 40.62 48.15 54.00 5.85 150 29 Horizontal PASS 2 2483.5990 7.53 56.964 55.88 74.00 18.12 36.455 43.99 54.00 10.01 150 316 Horizontal PASS 3 2486.2885 7.57 49.6 57.17 74.00 16.83 38.45 46.02 54.00 7.98 150 84 Horizontal PASS 4 2486.7505 7.60 49.38 56.98 74.00 17.02 35.56 43.16 54.00 10.84 150 47 Horizontal PASS 5 2488.1200 7.55 49.16 56.71 74.00 17.29 36.03 43.58 54.00 10.42 150 355 Horizontal PASS 6 2500.0000 7.60 47.49 55.09 74.00 18.91 34.53 42.13 54.00 11.87 150 193 Horizontal PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level Mode: 1M Channel: 2480MHz Test Graph Final Data List NO. Frequency [MHz] Factor [dB] PK Reading [dBμV/ m] PK Value [dBμV/m] PK Limit [dBμV/m] PK Margin [dB] AV Reading [dBμV/ m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Height [cm] Angle [°] Polarity Verdict 1 2483.5000 7.53 47.54 55.07 74.00 18.93 40.09 47.62 54.00 6.38 150 76 Vertical PASS 2 2484.6880 7.59 48.75 56.34 74.00 17.66 36.65 44.24 54.00 9.76 150 306 Vertical PASS 3 2486.5360 7.59 48.76 56.35 74.00 17.65 34.74 42.33 54.00 11.67 150 263 Vertical PASS 4 2488.2025 7.56 49.22 56.78 74.00 17.22 32.03 39.59 54.00 14.41 150 182 Vertical PASS 5 2493.2680 7.66 48.82 56.48 74.00 17.52 30.15 37.81 54.00 16.19 150 52 Vertical PASS 6 2500.0000 7.60 46.77 54.37 74.00 19.63 28.55 36.15 54.00 17.85 150 214 Vertical PASS Note:(1)Level=Reading+Factor (2)Margin=Limit-Level Appendix I: Spurious emissions Final Data List NO. Freq. [MHz] Factor [dB/m] QP Value [dBμV/m] QP Limit [dBμV/m] QP Margin [dB] Height [cm] Angle [°] Polarity Verdic t 1 36.3050 -14.36 18.01 40.00 21.99 200 312 Vertical PASS 2 46.2475 -14.21 16.32 40.00 23.68 200 52 Vertical PASS 3 581.9300 -7.27 26.35 46.00 19.65 200 145 Vertical PASS 4 696.7538 -5.12 25.59 46.00 20.41 100 264 Vertical PASS 5 844.3150 -2.55 27.73 46.00 18.27 200 305 Vertical PASS 6 955.6225 0.58 31.21 46.00 14.79 100 260 Vertical PASS Final Data List NO. Freq. [MHz] Fact…

Text truncated - open the document above for the full version.

Test Report

EUROFINS ELECTRICAL TESTING SERVICE (SHENZHEN) CO., LTD. RADIO TEST - REPORT FCC Compliance Test Report for Product name: Asset Beacon Model name: ILA-TBC300 FCC ID: 2BTDPILATBC300 Test Report Number: EFGX25090520-IE-06-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Phone: +86-0755-829118671 Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8 Fax: +86-0755-82910749 Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 1 of 26 1 General Information 3 1.1 Notes 3 1.2 Testing laboratory 4 1.3 Details of applicant 4 1.4 Details of manufacturer 4 1.5 Application details 5 1.6 Test item 5 1.7 Test standards 5 2 Technical test 6 2.1 Summary of test results 6 2.2 Test environment 6 2.3 Measurement uncertainty 6 2.4 Test mode 7 2.5 Test equipment utilized 8 2.6 Auxiliary equipment used during test 9 2.7 Test software information 9 2.8 Test setup 10 2.9 Test results 12 3 Technical Requirement 13 3.1 Conducted emission AC power port 13 3.2 Duty cycle 14 3.3 6dB bandwidth 15 3.4 99% Occupied Bandwidth 16 3.6 Conducted Peak output power 17 3.7 Power spectral density 18 3.8 Conducted Spurious Emissions 19 3.9 Band edge 20 3.10 Spurious radiated emissions for transmitter 23 4 Test Setup Photos 25 5 External Photo 25 6 Internal Photos 25 7 Appendix 25 Test Report No.: EFGX25090520-IE-06-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 3 of 25 1 General Information 1.1 Notes The results of this test report relate exclusively to the item tested as specified in chapter “Description of test item” and are not transferable to any other test items. Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. is not responsible for any generalisations and conclusions drawn from this report. Any modification of the test item can lead to invalidity of test results and this test report may therefore be not applicable to the modified test item. The test report may only be reproduced or published in full. Reproducing or publishing extracts of the report requires the prior written approval of the Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. This document is subject to the General Terms and Conditions and the Testing and Certification System of Eurofins Electrical Testing Service (Shenzhen) Co., Ltd., available on request or accessible at www.eurofins.com. Operator: 2025-12-08 Bruce Zheng / Project Engineer Date Eurofins-Lab. Name / Title Signature Technical responsibility for area of testing: 2025-12-08 Albert Xu / Lab Manager Date Eurofins-Lab. Name / Title Signature Test Report No.: EFGX25090520-IE-06-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 4 of 25 1.2 Testing laboratory Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Telephone : +86-755-82911867 Fax : +86-755-82910749 The Laboratory has passed the Accreditation by the American Association for Laboratory Accrediation (A2LA). The Accreditation number is 5376.01 The Laboratory has been listed by industry Canada to perform electromagnetic emission measurements, The CAB identifier is CN0088 1.3 Details of applicant Name : Intelligent Locations Address : 8601 Six Forks Rd., Suite 205, Raleig, North Carolina, 27615-5236, United States Telephone : ./. Fax : ./. 1.4 Details of manufacturer Name : Kaertech Limited Address : Suite 1601-02. Seaview Commercial Building, 21-24 Connaught Road West, Hong Kong Telephone : ./. Fax : ./. Test Report No.: EFGX25090520-IE-06-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 5 of 25 1.5 Application details Date of receipt of application : 2025-09-27 Date of receipt of test item : 2025-09-27 Date of test : 2025-09-27 to 2025-12-08 Date of issue : 2025-12-08 1.6 Test item Product type : Asset Beacon Test Model : ILA-TBC300 Sample ID : 250927-11-001 Brand : ./. Serial number : ./. Hardware Version : 3.0 Software / Firmware Version : 2.8 Ratings : DC 3V Test voltage : DC 3V RadioTechnical data Frequency range : 2402MHz – 2480MHz Radio Tech. : Bluetooth Low Energy Frequency channel : 40 Channels Modulation : GFSK Antenna type : PCB antenna Maximum antenna gain : 0.45 Additional information : ./. The above sample(s) and sample information was/were submitted and identified on behalf of the applicant. Eurofins assures objectivity and impartiality of the test, and fulfills the obligation of confidentiality for applicant’s commercial infor- mation and technical documents. 1.7 Test standards Test Standards FCC Part 15 Subpart C PART 15 - RADIO FREQUENCY DEVICES Subpart C - Intentional Radiators Test Method 1: ANSI C63.4-2014, American National Standard for Methods of Measurement of Radio-Noise Emis- sions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. 2: ANSI C63.10-2020, American National Standard for Testing Unlicensed Wireless Devices. 3: KDB558074 D01 15.247 Meas Guidance v05r02 Test Report No.: EFGX25090520-IE-06-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 6 of 25 2 Technical test 2.1 Summary of test results No deviations from the tec…

Text truncated - open the document above for the full version.

Test Report

NOTE:ThisdocumentisissuedbyShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,thetestreportshallnotbereproducedexceptin fullwithoutpriorwrittenpermissionofthecompany.Thetestresultsapplyonlytotheparticularsample(s)testedandtothespecifictestscarried outwhichisavailableonrequestforvalidationandinformationconfirmedatourwebsite. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.,FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page1of 11 REPORTNo.:SZ26020115E01 TESTREPORT APPLICANT:IntelligentLocations PRODUCTNAME:PCBAntenna MODELNAME:ILA-TBC300 TRADENAME:N/A BRANDNAME:N/A STANDARD(S):IEEEStd149-2021 RECEIPTDATE:2025-02-09 TESTDATE:2025-03-02 ISSUEDATE:2025-04-20 Editedby: GuoPenghua(Rapporteur) Approvedby: ChiShide(Supervisor) MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page2of11 REPORTNo.:SZ26020115E01 DIRECTORY 1.TechnicalInformation ........................................................................................................3 1.1.ApplicantandManufacturerInformation ....................................................................3 1.2.EquipmentUnderTest(EUT)Description...................................................................3 2.TestResults........................................................................................................................4 2.1.AppliedReferenceDocuments.....................................................................................4 2.2.TestConditions...............................................................................................................4 2.3.MeasurementUncertainty.............................................................................................4 2.4.TestResultslists.............................................................................................................5 AnnexATestSetupPhotos..................................................................................................6 AnnexBFigures .....................................................................................................................7 1.2DRadiationPattern .........................................................................................................7 2.3DRadiationPattern .........................................................................................................8 AnnexCTestingLaboratoryInformation .........................................................................10 1.IdentificationoftheResponsibleTestingLaboratory ................................................10 2.IdentificationoftheResponsibleTestingLocation....................................................10 3.TestEquipmentUtilized..................................................................................................10 3.1TestEquipments............................................................................................................10 3.2TestSoftware..................................................................................................................10 Notes......................................................................................................................................11 AnnexDEUTPhotos ChangeHistory VersionDateReasonforchange 1.02026-04-20Firstedition Note:thelatestrevisionofthereportsupersedesallpreviousversion. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page3of11 REPORTNo.:SZ26020115E01 1.TechnicalInformation Note:Providebyapplicant. 1.1.ApplicantandManufacturerInformation Applicant: IntelligentLocations ApplicantAddress: 8601SixForksRd.,Suite205,Raleig,NorthCarolina,27615-5236, UnitedStates Manufacturer: N/A ManufacturerAddress: N/A 1.2.EquipmentUnderTest(EUT)Description WirelessType N/A Frequency 2400MHz-2500MHz AntennaType N/A ProductHWVersion N/A ProductSWVersion N/A SerialNumber N/A SampleNo. 1# MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page4of11 REPORTNo.:SZ26020115E01 2.TestResults 2.1.AppliedReferenceDocuments Leadingreferencedocumentsfortesting: No.IdentityDocumentTitle 1IEEEStd149-2021 IEEERecommendedPracticeforAntenna Measurements Notes:Anyadditions,deviation,orexclusionsfromthemethodshallbenotedinthe"Remark". 2.2.TestConditions TestEnvironmentConditions : RelativeHumidity(%):25-75 Temperature(°C):10-30 2.3.MeasurementUncertainty Theuncertaintyiscalculatedusingthemethodssuggestedinthe“GuidetotheExpressionof UncertaintyinMeasurement”(GUM)publishedbyISO. MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page5of11 REPORTNo.:SZ26020115E01 2.4.TestResultslists 2.4.1.Gain Frequency (MHz) Gain(dBi) 24000.45 24100.43 24200.18 2430-0.22 2440-0.14 2450-0.24 2460-0.30 2470-0.61 2480-0.81 2490-0.74 2500-0.74 MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page6of11 REPORTNo.:SZ26020115E01 AnnexATestSetupPhotos MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8L…

Text truncated - open the document above for the full version.

Test Setup Photos

MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page1of3 REPORTNo.:SZ26020115E01 AnnexDEUTPhotos 1.Testenvironment MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page2of3 REPORTNo.:SZ26020115E01 2.EUT MORLAB ShenzhenMorlabCommunicationsTechnologyCo.,Ltd.FL.1-3,BuildingA, FeiYangSciencePark,No.8LongChangRoad,Block67,BaoAnDistrict, ShenZhen,GuangDongProvince,P.R.China Tel:86-755-36698555Fax:86-755-36698525 Http://www.morlab.cnE-mail:[email protected] Page3of3 REPORTNo.:SZ26020115E01

Contact Information

Applicant

Bogdan Nedelcu(CEO)
[email protected]Fax: N/A

Technical Contact

Intelligent LocationsBogdan Nedelcu
[email protected]

8601 Six Forks Rd., Suite 205 · Raleig · United States

Test Firm

Eurofins Electrical Testing Service (Shenzhen) Co.Lynn Su
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz54.00 µW
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted.