â Wristbandâ Deviceâ Charging base Whatâs Included in the Box Smart Health Band V8S User Manual â Type-C charging cableâ User manual Smart Health Band V8S User Manual 2.5cm Introduction This is a smart health bracelet which can monitor multiple body vital signs under many different activity modes. Note: The watch is not a medical device. The test results and suggestions are for reference only. Sleep Tracking Sleep Apnea Monitoring 24/7 Heart Rate Blood Glucose Female Wellness ECG Skin Temperature Trend Activity Tracking SpO2Blood Pressure HRVStress Instructions for Use 1. Initial Use & Wearing Initial Charging: For first-time use, please fully charge the device to activate it. If you perform a factory reset via the mobile App, you will also need to charge the device to turn it back on. Proper Wearing: Insert the main unit into the strap buckle and then wear it on your wrist. It is recommended to position the strap approximately 2.5cm above your wrist bone. Ensure it is snug but comfortable, allowing the sensors to maintain full contact with your skin without causing pressure. A simple test: If you can easily slide your little finger between the strap and your wrist, the fit is too loose. 2. ECG Measurements: When the bracelet is awake, the App initiates ECG measurement, which lasts 30 seconds. After the measurement is completed, the App can view the real-time ECG waveform, generate an ECG report, and the user can also download the ECG waveform. Cover the electrode area with your finger. SOS 3. Charging & Battery Life Charging the Device: Connect the charging base to a Type-C cable, then place the device on the charging base to begin charging. During charging, the green light flashes slowly. When fully charged, the green light remains steadily lit. Battery Indicator: The indicator light on the main unit displays the remaining battery level through color codes: SOS LED Indicator SOS Button HR & SpO2 Sensor ECG & Body Temperature Sensor ECG Electrodes Red light: Battery level is between 0%~20%. Green light: Battery level is between 20%~100%. Battery below 5%: The red light will flash three times, after which the device will automatically power off. Battery Life: Under full charge, the device supports approximately 15+ days of normal use or about 30 days on standby. Actual battery life depends on enabled features, usage frequency, and environmental conditions. If the device doesnât pair with your smartphone 1. Make sure your device is turned on. 2. Check your smartphone to ensure Bluetooth is on. 3. Check the app to make sure Bluetooth Troubleshooting permissions are turned on. This should be in your Bluetooth settings. 4. Restart the app and go to the app home screen. 5. The device battery should display on your app device screen. If the device isnât measuring any data Please contact our support team. If the device battery is draining too quickly 1. Calibrate your battery by charging it for at least three hours. 2. Start using your device again as you normally would. 3. Contact our support team if the problem persists. If the device causes an allergic reaction Please stop using the device right away. In the rare event of an anaphylactic reaction, seek medical attention immediately. If the issue isnât mentioned in these tips Please contact our support team and report the issue in detail. Failure to follow these safety instructions could result in fire, electric shock, injury, or damage to the device or other property. Read all the safety information below before using the device. Not a Medical Device Itâs not a medical device and should not be used as a substitute for professional medical judgment. It is not designed or intended for use in the diagnosis of disease or other conditions, or in the cure, mitigation, treatment, or prevention of any condition or disease. Please consult your healthcare professional prior to making any decisions related to your health. Handling Handle this device with care as it contains sensitive electronic components and can be damaged if dropped, burned, punctured, or crushed. Donât use a damaged Move Wearable as it may cause injury. Avoid heavy exposure to dust or sand. Children should not be allowed to play with the device without supervision. Battery Do not attempt to replace the device battery yourself, you may damage the battery, which could cause overheating and injury. The lithium-ion battery in the device should be serviced only by manufacturer or an authorized service provider. Batteries must be recycled or disposed of separately from household waste. Do not incinerate the battery. Do not dispose of the device in domestic waste. If you have any questions, please contact us. Operating Temperature This device is designed to work in ambient temperatures between 32°F and 113°F (0°C and 45°C) and be stored in temperatures between -4°F and 158°F (-20°C and 70°C). It can be damaged and battery life shortened if stored or operated outside of these temperature ranges. Avoid exposing this device to dramatic changes in temperature or humidity. Prolonged Heat Exposure Do not expose the device to extreme tempera- tures or extreme temperature fluctuations. Protect the device from direct sunlight. While this device is charging or the power plug is plugged into a power source, do not sleep on it or place it under a blanket, pillow, or your body. Take special care if you have a physical condition that affects your ability to detect heat against the body. Safety Notices Any changes or modifications not expressly approved by the party responsible for compliance could void the userâs authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class âŚ
Text truncated - open the document above for the full version.
GuangdongYouhongMedicalTechnologyCo.,Ltd Room902,Building6,No.4InformationRoad,SongshanhuDistrict,Dongguan, Guangdong,China FederalCommunicationsCommission AuthorizationandEvaluationDivision EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MD21046 DateďźJune3,2026 U.S.AgentDesignation {GuangdongYouhongMedicalTechnologyCo.,Ltd}acknowledgestheirconsentforthefollowingcontact locatedintheUnitedStatestoactastheiragentforserviceofprocessfortheequipmentforwhichauthorization issought(FCCID:2BTDQ-V8S): NameandcompanyofU.S.agent:BridgeportAdvisoryLLC PhysicalU.S.addressofagent:3330W38THPL,CHICAGO,IL60632,UnitedStates FRNofU.S.agent:0037566148 EmailaddressofU.S.agent:[email protected] ContactNO.:(708)680-6688 BridgeportAdvisoryLLCacknowledgestheirobligationtoacceptserviceofprocessonbehalfof{Guangdong YouhongMedicalTechnologyCo.,Ltd}. {GuangdongYouhongMedicalTechnologyCo.,Ltd}withtheFRN[0037688967]acceptsitsobligationto maintainanagentforserviceofprocessintheUnitedStatesfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S.,orthe conclusionofanyCommission-relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheveris later. Bysigningthisform,weconfirmtheaboveandthatweareawareoftheapplicationrequirementslistedunder§ 2.911(d)(7). TheinformationprovidedinthisletterisbasedonthereferencedrulepartsofTitle47oftheCFRaswellasKDB 986446D01. Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,thegranteeisobligatedtonotify theFCCwithin30daysviathegrantingTCB. Sincerely, Signature ZhangBo Manager GuangdongYouhongMedicalTechnologyCo.,Ltd Signature MrYongLiu ManagingMember BridgeportAdvisoryLLC 4 8 _ [ m o d e l ] U S _ A g e n t _ 2 . 9 1 1 ( d ) ( 7 ) - U , V 0 5
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commissionâs Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BTDQ-V8S V8S We, Applicant Company Name: Guangdong Youhong Medical Technology Co., Ltd Address: Room 902, Building 6, No. 4 Information Road, Songshanhu District, Dongguan, Guangdong, China Phone: +86-755 2664 8642 certify that the equipment for which authorization is sought is not âcoveredâ equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing âcoveredâ equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-06-03 Signature Date Name / Title: Bo Zhang / Manager Company: Guangdong Youhong Medical Technology Co., Ltd Address: Room 902, Building 6, No. 4 Information Road, Songshanhu District, Dongguan, Guangdong, China Phone: +86-755 2664 8642 Fax: N/A E-Mail: [email protected]
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2BTDQ-V8S V8S Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-06-15
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commissionâs Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BTDQ-V8S V8S For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: ⢠the Operational Description ⢠the Block Diagram ⢠the Schematics ⢠the Part List ⢠the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-06-03 Signature Date Name / Title: Bo Zhang / Manager Company: Guangdong Youhong Medical Technology Co., Ltd Address: Room 902, Building 6, No. 4 Information Road, Songshanhu District, Dongguan, Guangdong, China Phone: +86-755 2664 8642 Fax: N/A E-Mail: [email protected]
Externalphotos FCC ID: 2BTDQ-V8S
SmartHealthBand Mode: V8S Input:3.8V180mA FCCID:2BTDQ-V8S Size:25*8mm Labellocation
Internalphotos FCC ID: 2BTDQ-V8S Antenna
ShenzhenHuaxiaTestingTechnologyCo.,Ltd. SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD102A,102B,Building2,ShanghenglangNew IndustrialZone,ShanghenglangCommunity,DalangStreet,LonghuaDistrict,Shenzhen,Guangdong, PeopleâsRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V04 ReportTemplateRevisionDate:2018-07-06 TESTREPORT Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlytothe sample(s)tested.WithoutwrittenapprovalofCQA,thisreportcanâtbereproducedexceptinfull. ReportNo.: CQASZ20260501020E-02 Applicant:GuangdongYouhongMedicalTechnologyCo.,Ltd AddressofApplicant:Room902,Building6,No.4InformationRoad,SongshanhuDistrict,Dongguan, Guangdong,China EquipmentUnderTest(EUT): EUTName:SmartHealthBand ModelNo.:V8S TestModelNo.:V8S BrandName:N/A FCCID:2BTDQ-V8S Standards: 47CFRPart1.1307 47CFRPart1.1310 KDB447498D01GeneralRFExposureGuidancev06 DateofReceipt:2026-05-21 DateofTest: 2026-05-21to2026-05-29 DateofIssue: 2026-06-15 TestResult:PASS TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ20210400416E-03 Page: 2 of 6 1.Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260501020E-02Rev.01 Initialreport 2026-06-15 ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ20210400416E-03 Page: 3 of 6 2.Contents 1.VERSION....................................................................................................................................................................................2 2.CONTENTS................................................................................................................................................................................3 3.GENERALINFORMATION....................................................................................................................................................4 4.CLIENTINFORMATION........................................................................................................................................................4 5.GENERALDESCRIPTIONOFEUT......................................................................................................................................4 RFEXPOSUREEVALUATION..................................................................................................................................................5 RFEXPOSURECOMPLIANCEREQUIREMENT.............................................................................................................................5 StandardRequirement........................................................................................................................................................5 Limits......................................................................................................................................................................................5 EUTRFExposure................................................................................................................................................................6 ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ20210400416E-03 Page: 4 of 6 3.GeneralInformation 4.ClientInformation Applicant: GuangdongYouhongMedicalTechnologyCo.,Ltd AddressofApplicant: Room902,Building6,No.4InformationRoad,SongshanhuDistrict, Dongguan,Guangdong,China Manufacturer: GuangdongYouhongMedicalTechnologyCo.,Ltd AddressofManufacturer: Unit2,Building4,No.3NanshanRoad,SongshanhuDistrict,Dongguan, Guangdong,China Factory: GuangdongYouhongMedicalTechnologyCo.,Ltd AddressofFactory: Room902,Building6,No.4InformationRoad,SongshanhuDistrict, Dongguan,Guangdong,China 5.GeneralDescriptionofEUT ProductName:SmartHealthBand ModelNo.:V8S TestModelNo.:V8S TradeMark:N/A SoftwareVersion: V8S_V002 HardwareVersion: 2603_MB_V1.0 ModulationType: GFSK TransferRate: 1Mbps NumberofChannel: 40 AntennaType: FPCantenna AntennaGain: -3.69dBi ProductType: MobilePortable PowerSupply: Li-ionbattery:DC3.8V180mAh,ChargebyDC5Vforadapter ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ20210400416E-03 Page: 5 of 6 RFExposureEvaluation RFExposureComplianceRequirement StandardRequirement AccordingtoKDB447498D01GeneralRFExposureGuidancev06 4.3.1.StandaloneSARtestexclusionconsiderations UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone1- gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARExclusionThresholdcondition,listedbelow,issatisfied. Limits The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distancesâ¤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]¡[âf(GHz)]â¤3.0for1-gSARandâ¤7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation17 Theresultisroundedtoonedecimalplaceforcomparison Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceisâ¤50mm andfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmisappliedtodetermineSARtestexclusion ShenzhenHuaxiaTestingTechnologyCo.,Ltd ReportNo.:CQASZ20210400416E-03 Page: 6 of 6 EUTRFExposure 1)ForBLE MeasurementData Worstcase:GFSK TestChannel PeakOutputPower (dBm) Tuneuptolerance (dBm) Maximumtune-upPower (dBm)(mW) Lowest(2402MHz) 5.265.5Âą16.54.467 Middle(2440MHz) 6.607.0Âą186.310 Highest(2480MHz) 3.684.0Âą1 5 3.162 Worstcase:GFSK Channel MaximumtuneupPower (mW) Calculatedvalue Exclusion threshold Lowest (2402MHz) 4.4671.385 3.0 Middle (2440MHz) 6.3101.972 Highest (2480MHz) 3.1620.995 Conclusion:thecalculatedvalueâ¤3.0,SARisexempted. Remark:TheMaxConductedPeakOutputPowerdatarefertoreportReportNo.:CQASZ20210400416E-01
Antenna Specifications NameofthebuyerďźShenzhen Youhong Technology Co., Ltd Buyer's material numberďź Supplier company name: Shenzhen Xinrui Communication Technology Co., Ltd. Supplier product material numberďź2510A-BT-V0.2 Supplier product description:built-in BT antenna Remarksďź Signature of the demanderďźThe demander sealďź Signature of the supplierďźSeal of the Supplierďź MAKEďź YE WENJUAN DATEďź 2026.1.04 ADDRESSSupplier Address: 2nd Floor, Yulong Office Building, Longcheng Industrial Zone, No. 440, Longguan Avenue, Longhua New District, Shenzhen PHONE0755-29351613 FAX0755-29351510 Product model Date of productionPage number 2510A2026.01.04 2 / 5 MAKER Examine and verifyRatify YE WENJUANXingtu WuYe He 1ăAntenna pictures 2.1ăPhysical characteris 2.1ăPhysical characteristics Antenna Dimensions (mm)22.47*5.18Cable length (mm)N/A Connector modelN/AType of CableN/A Antenna materialFPCAntenna colourBlack Working temperature-30°C~75°CWorking humidity10%~95% Storage temperature-30°C~75°CStorage humidity10%~95% 2.2ăElectrical characterďźelectrical specification frequencyďźMHzďź2400~2500Impedance0 ćŹ§ĺ§ GainďźMAXďź-3.69 dBi銝VSWRâ¤3 PolarizationLine Product model Date of productionPage number 2510A2026.1.01 3 / 5 MAKER Examine and verifyRatify YE WENJUANXingtu WuYe He 3ăSParameter Product model Date of productionPage number 2510A2026.1.04 4 / 5 MAKER Examine and verifyRatify YE WENJUANXingtu WuYe He 4ă3D/2DRadiation Pattern Product model Date of productionPage number 2510A2026.1.04 5 / 5 MAKER Examine and verifyRatify YE WENJUANXingtu WuYe He 5ăSchedule Drawing
SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,PeopleâsRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcanâtbereproducedexceptinfull. ReportNo.:CQASZ20260501020E-01 Applicant:GuangdongYouhongMedicalTechnologyCo.,Ltd AddressofApplicant:Room902,Building6,No.4InformationRoad,SongshanhuDistrict,Dongguan, Guangdong,China EquipmentUnderTest(EUT): Product:SmartHealthBand ModelNo.:V8S TestModelNo.:V8S BrandName:N/A FCCID:2BTDQ-V8S Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2026-05-21 DateofTest:2026-05-21to2026-05-29 DateofIssue:2026-06-15 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260501020E-01 Page: 2 of 51 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260501020E-01Rev.01Initialreport2026-06-15 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260501020E-01 Page: 3 of 51 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203/15.247(c) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ACPowerLine Conducted Emission 47CFRPart15,SubpartCSection 15.207 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ConductedPeakOutput Power 47CFRPart15,SubpartCSection 15.247(b)(3) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS 6dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.247(a)(2) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS PowerSpectralDensity 47CFRPart15,SubpartCSection 15.247(e) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Band-edgeforRF ConductedEmissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RFConductedSpurious Emissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RadiatedSpurious Emissions 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260501020E-01 Page: 4 of 51 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................7 4.4TESTENVIRONMENT...................................................................................................................................................8 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................8 4.6TESTCONFIGURATION................................................................................................................................................8 4.7STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................9 4.8TESTLOCATION........................................................................................................................................................10 4.9TESTFACILITY..........................................................................................................................................................10 4.10DEVIATIONFROMSTANDARDS................................................................................................................................10 4.11OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..........................................................................................10 4.12EQUIPMENTLIST.....................................................................................................................................................11 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................12 5.1ANTENNAREQUIREMENT..........................................................................................................................................12 5.2CONDUCTEDEMISSIONS............................................................................................................................................13 5.3CONDUCTEDPEAKOUTPUTPOWER.....................................................âŚ
Text truncated - open the document above for the full version.
Setupphotos 1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2BTDQ-V8S Above1GHz: 1.2ConductedEmissionsTestSetup 1.3RFConductedmeasurement
3330 W 38TH PL, CHICAGO, ¡ Illinois, 60632 ¡ United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 4.60 mW |

Smart Health Ring
Equipment Class
DTS - Digital Transmission System