FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dongguan City JuPinMeisheng Electronic Technology Co., Ltd./
  3. 2BTJK-F115

2BTJK-F115A phone stand with wireless charging

Dongguan City JuPinMeisheng Electronic Technology Co., Ltd.
A phone stand with wireless charging - FCC ID 2BTJK-F115 - Dongguan City JuPinMeisheng Electronic Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Dec 19, 2025
Application Purpose
Original Equipment
Equipment Note
A phone stand with wireless charging
Frequency Range
2402.00000000 - 2480.00000000
Company
Dongguan City JuPinMeisheng Electronic Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTRUCTIONS Wireless charging area Product parameters Product model: F115 Product color: Black Product Material: ABS+PC Input voltage: 5V-9V Speaker: SW Bluetooth version: 5.4 Battery model: 18650 Output power: 5W Playback mode: Mobile connection pilot lamp playback/USB+ TF card playback Tcardslot Charginginterface USAGE METHOD: 1. Open the packaging and fully charge before first use. 2. Slide the power switch to the right to turn on the device, and the audio system will display a voice prompt for Bluetooth pairing (Bluetoolh Mode). At the same time, the audio indicator light wUI flash blue (if the charging cable is plugged in at this time, it will flash red and blue). Search for the Bluetooth device of the speaker using the Bluetooth function on your phone and connect ii (device model F115) to this blue speaker. The sound system displays a voice prompt (ding dong sound) indicating a successful Bluetoolh connection. Open the mobile music player and the speaker to play mobile music through Bluetooth. 3. Play USB flash drivefTF caret You can directly insert the USB flash drive into the USB interf a ce (or insert the TF card speaker to automatically play TF card music (with Iha printed side of the TF card facing downwards), and the speaker will automatically switch to playing songs from the USB flash drive/TF card. 4. During the music playback process (regardless of the playback mode), press I◄◄ to control the previous song, press ►►Ito control the next song ►U\.to control play/pause, MODE key mode switching, and rotate the button to adjust the volume during the music playback process WIRELESS CHARGING METHOD; 1. Ensure that the phone supports wireless charging function 2. Insert the 5V3A or f a st charging adapter into the charging port of the phone holder. 3. Align the phone with the charging panel on the phone holder to ensure light contact between them. The indicator light will tum into a stable blue light. Indicates that the phone is charging (if there is a metal object on the panel, the wireless charging status is incorrect and the indicator light wil flash) FCC warning statements: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The device has been evaluated to meet general RF exposure requirement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: Companyname:HOPEKCORPORATIONINC FRN:0034562900 ContactName:PeterDavis Address:16755CoyoteBushDrUnit84,SanDiego,CA92127UnitedStates TelephoneNo:561-235-6113 Email:[email protected] Applicant: Companyname:DongguanCityJuPinMeishengElectronicTechnologyCo.,Ltd. GranteeCode:2BTJK FCCID:2BTJK-F115 FRN:0037722295 ContactName:JingsongZeng Address:No.19-1YangmeiyuanStreet,TangxiaTown,DongguanCity,China TelephoneNo:13798350738 FaxNo:/ Email:[email protected] DongguanCityJuPinMeishengElectronicTechnologyCo.,Ltd.certifiesthat,asofthedate ofthisfilingoftheapplicationwiththeTCB,[HOPEKCORPORATIONINC]isourdesignated USagentforserviceofprocessfortheabovereferencedFCCID.DongguanCity JuPinMeishengElectronicTechnologyCo.,Ltd.acceptstomaintainanagentfornoless thanoneyearafterthegranteehasterminatedallmarketingandimportationortheconclusion ofanycommissionrelatedproceedinginvolvingequipment.[HOPEKCORPORATIONINC] accepts,asofthedateofthefilingoftheapplication,theobligationofthedesignatedUSagent forserviceofprocessfortheabovereferenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,and clause§2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2025-12-12 Applicant’sName:JingsongZengUSAgent’sName:PeterDavis Title:ProjectmanagerTitle:Manager Signature:Signature:

Attestation Statements

Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. December 11, 2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2BTJK-F115 [Dongguan City JuPinMeisheng Electronic Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, Jingsong Zeng Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. December 11, 2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2BTJK-F115 [Dongguan City JuPinMeisheng Electronic Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Jingsong Zeng

Cover Letter(s)

Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. 12/11/2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: CONFIDENTIALITY REQUEST FOR Product Name: A phone stand with wireless charging FCC ID: 2BTJK-F115 Model(s): F115 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the (Schematic Diagram, Block Diagram, Operational Description) required to be submitted with this application be permanently withheld from public review. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market Please contact me if there is any information you may need. Sincerely, Signature: December 11, 2025 Name Jingsong Zeng Position Project manager Company Name Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. Address No.19-1 Yangmeiyuan Street, Tangxia Town, Dongguan City, China Tel 13798350738 Fax / Email [email protected]

Cover Letter(s)

Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. 12/11/2025 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize (Shenzhen PSI Testing Co., Ltd.) to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This agreement expires one year from the current date. Sincerely, Signature: December 11, 2025 Name Jingsong Zeng Position Project manager Company Name Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. Address No.19-1 Yangmeiyuan Street, Tangxia Town, Dongguan City, China Tel 13798350738 Fax / Email [email protected]

External Photos

Page 1 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix II external photos FCC ID: 2BTJK-F115 Page 2 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 3 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 4 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------

ID Label/Location Info

Label and Location Material: Silk-screen Font color: White  Size: L: 6cm*W: 3cm Label and Location W FCC ID: 2BTJK-F115 Model No.: F115 L

Internal Photos

Page 1 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix III internal photos FCC ID: 2BTJK-F115 Page 2 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China BT ANT Page 3 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 4 of 4 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China ------End------ Coil ANT

RF Exposure Info

Page 1 of 2 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix IV MPE FCC ID: 2BTJK-F115 Prediction of MPE at a given distance 1. Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) KDB Test Methodology: KDB 447498 D01 v06. 2. Test Procedure Equation from page 18 of OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to the antenna G = numeric gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the centre of radiation of the antenna Page 2 of 2 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China 3. Result Mode Frequency (MHz) Prediction distance (cm) RF output power(Max) (dBm) Tune-up power (Max) MPE (mW/cm 2 ) Limit (mW/cm 2 ) SAR Test Exclusion dBm mW BT EDR 2402-2480 20 0.39 1 1.2589 0.0002 1 Yes BT Antenna: max gain -0.23dBi, 0.95(numeric) Therefore this device complies with FCC's RF radiation exposure limits for general population without SAR evaluation.

Test Report

MeanderInvertedFAntenna Specification ProductName:BT-ANT-MIFA_01 Description:MeanderInvertedFAntenna Revision:V1.0 Writtenby:HuMingbo Checkedby:__________ Data:2025-9-12 DateVersionAotherChangements 2025-9-12V1.0MingboHuInitialversion 1.TestProcedure 1.1TestProcedure Puttheantennaintotheanechoicchamber,connecttheantennatotheVNAandstart measurement. 1.2TestSetup 2.TestData 2.1.Characteristics. 2.2.S11parameters No.NameSpecification 1Frequencyrange2400MHz~2500MHz 2Impendence50ohm 3MaterialFR-4 2.3.VSWR 2.4.Gain 2.5.Efficiency 2.4.RadiationPattern 2.4.1X-ZPlaneVPHI=0 No.Frequency(MHz)VSWR 124001.76 224501.28 325001.41 No.Frequency(MHz)Gain(dBi) 12400-0.23 22450-0.25 32500-2.01 No.Frequency(MHz)Efficiency(%) 1240023.9 2245024.5 3250024.1 2.4.2Y-ZPlaneVPHI=90 2.4.3Y-XPlane HPHI=90 2.4.43DRadiationPatternat2.45GHz 3.Construction 4.Recommendedoperatingandstoringconditions. 5.Applications ThisMeanderlineantennaspecificationcouldbesuitableforthefollowingmodules: 1.BT-MC89-JK1 2.BT-MC89-JKx No.ItemConditions 1OperatingTemperature-40°C~+85°C 2StorageTemperature-40°C~+90°C

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 87 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2BTJK-F115 On Behalf of Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. A phone stand with wireless charging Model No.: F115 Prepared for : Dongguan City JuPinMeisheng Electronic Technology Co., Ltd. Address : No.19-1 Yangmeiyuan Street, Tangxia Town, Dongguan City, China Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2509099-C01-R06 Date of Receipt : September 12, 2025 Date of Test : September 12, 2025 – November 13, 2025 Date of Report : November 15, 2025 Version Number : V0 Page 2 of 87 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Page 1. Summary Of Standards And Results............................................................................................ 6 1.1. Description of Standards and Results ..................................................................................... 6 2. General Information........................................................................................................................ 7 2.1. Description of Device (EUT) .................................................................................................... 7 2.2. Accessories of Device (EUT) .................................................................................................. 8 2.3. Tested Supporting System Details .......................................................................................... 8 2.4. Block Diagram of connection between EUT and simulators ................................................... 8 2.5. Test Mode Description ............................................................................................................. 9 2.6. Software test version and power setting information .............................................................. 9 2.7. Test Conditions ...................................................................................................................... 10 2.8. Test Facility ............................................................................................................................ 10 2.9. Measurement Uncertainty ..................................................................................................... 10 2.10. Test Equipment List ............................................................................................................... 11 3. Maximum Conducted Output Power ........................................................................................... 12 3.1. Test Limit ............................................................................................................................... 12 3.2. Test Procedure ...................................................................................................................... 12 3.3. Test Setup .............................................................................................................................. 12 3.4. Test Results ........................................................................................................................... 13 4. Occupied Bandwidth .................................................................................................................... 14 4.1. Test Limit ............................................................................................................................... 14 4.2. Test Procedure ...................................................................................................................... 14 4.3. Test Setup .............................................................................................................................. 15 4.4. Test Results ........................................................................................................................... 15 5. Carrier Frequency Separation ..................................................................................................... 26 5.1. Test Limit ............................................................................................................................... 26 5.2. Test Procedure ...................................................................................................................... 26 5.3. Test Setup .............................................................................................................................. 26 5.4. Test Results ........................................................................................................................... 27 6. Number Of Hopping Channel ...................................................................................................... 29 6.1. Limit ....................................................................................................................................... 29 6.2. Test Procedure ...................................................................................................................... 29 6.3. Test Setup .............................................................................................................................. 29 6.4. Test Results ........................................................................................................................... 30 7. Dwell Time .....................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix I Test Setup Photo FCC ID: 2BTJK-F115 Spurious Radiation Emissions Test (9KHz-30MHz) Spurious Radiation Emissions Test (<1G) Page 2 of 2 Report No.: psi2509099-C01-R06 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Spurious Radiation Emissions Test (>1G) Conducted emission Test ------End------

Contact Information

Applicant

Jingsong Zeng(Project manager)
[email protected]Fax: N/A

Technical Contact

HOPEK CORPORATION INCPeter Davis
[email protected]

16755 Coyote Bush Dr Unit 84 · CA, 92127 · United States

Test Firm

Shenzhen PSI Testing Co., Ltd.Simple Guan
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.09 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter device