Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
GuangdongHanyingPhotoelectricTechnologyCo.,Ltd 2.911(d)(7)USAAgentv1.5 Section2.911(d)(7)USAAgentforServiceofProcess Companyname:GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Address:Room201,Building3,No.3simalndustrialRoad,ChangpingTown, DongguanCity,GuangdongProvince,China FCCID:2BTMB-HY350MAX 2.911(d)(7)USADesignatedAgentforServiceofProcess We,[GuangdongHanyingPhotoelectricTechnologyCo.,Ltd]designate[LinkwldLLC] NOTE1 forthepurposeofacceptingserviceofprocessonbehalfoftheapplicant. Applicantconsent:Weacknowledgeourconsenttoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddressofthedesignatedagentandacknowledgeour acceptanceofourobligationtomaintainanagentforserviceofprocessintheUnited Statesfornolessthanoneyearaftereitherwethegranteehavepermanently terminatedallmarketingandimportationoftheapplicableequipmentwithintheU.S., orattheconclusionofanyCommission-relatedadministrativeorjudicialproceeding involvingtheequipment,whicheverislater. Agentobligation:Weacknowledgeourobligationtoacceptserviceofprocessinthe UnitedStatesformattersrelatedtotheapplicableequipmentatourphysicalU.S. addressandemailaddressfornolessthanoneyearaftereitherthegranteehas permanentlyterminatedallmarketingandimportationoftheapplicableequipment withintheU.S.,orattheconclusionofanyCommission-relatedadministrativeor judicialproceedinginvolvingtheequipment,whicheverislater. USAAgentApplicant Companyname:LinkwldLLCCompanyname:GuangdongHanying PhotoelectricTechnologyCo.,Ltd USAAddress:7595TechnologyWaySte 100,Denver,CO80237,US Address:Room201,Building3,No.3sima lndustrialRoad,ChangpingTown, DongguanCity,GuangdongProvince, China FRNNumber:0033625682GranteeFRNNumber:0037735552 ContactName:TimothyZhu FCCGranteeCode:2BTMB TelephoneNo:(747)717-2691ContactName:GuoyangWang Email:[email protected]:19117952999 Email:[email protected] Signature: GuangdongHanyingPhotoelectricTechnologyCo.,Ltd 2.911(d)(7)USAAgentv1.5 Title:Manager Signature: Title:Manager Date:2026-01-09Date:2026-01-09 NOTE1:AnapplicantlocatedintheUnitedStatesmaydesignateitselfastheagentforservice ofprocess. Reference;FederalRegisterdocument2022-28263publishedon02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the
GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity,GuangdongProvince, China 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:Jan.14,26 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:2BTMB-HY350MAX ProductName:SmartProjector Thisletterservesasanattestationthattheequipmentidentifiedaboveisnot(selectone)"covered"software asdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,asoutlined inFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, PrintedName:GuoyangWang Title:Manager Address:Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity,Guangdong Province,China Tel.:19117952999 Email:[email protected] GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity,GuangdongProvince, China 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☐ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☐ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☐ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☐ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☒ EvaluationBasedonSoftware BillofMaterials(SBoM) Seeattached“SBoM“ Note:TheSBoMcontentislimited tothescopeofcoveredlist software(e.g.antivirusand cybersecuritysoftware). ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck SBoM(SoftwareBillofMaterials): SectionComponentNameVersionSupplier 1Android14Google
GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity,Guangdong Province,China AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:1/9/2026 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BTMB-HY350MAX GuangdongHanyingPhotoelectricTechnologyCo.,Ltdcertifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002of referencechapter,asanentityproducing“covered”communicationequipment.Theequipmentfor whichauthorizationissoughtisnot“covered”telecommunicationsequipmentandvideosurveillance equipmentproducedbyentitiesidentifiedontheCommission’sCoveredListthatprohibitedfrom receivinganequipmentauthorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, PrintedName:GuoyangWang Title:Manager Address:Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity,Guangdong Province,China Tel.:19117952999 Email:[email protected]
GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity, GuangdongProvince,China 2026/1/9 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BTMB-HY350MAX I,theundersigned,herebyauthorize(ShenzhenAnbotekComplianceLaboratoryLimited.)toactonour behalfinallmattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(ShenzhenAnbotekComplianceLaboratoryLimited.)shallhavethesameeffectas ourownandIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsof certification,asspecifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith (GuangdongHanyingPhotoelectricTechnologyCo.,Ltd). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, PrintedName:GuoyangWang Title:Manager Tel.:19117952999 Fax:N/A Email:[email protected]
GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Room201,Building3,No.3simalndustrialRoad,ChangpingTown, DongguanCity,GuangdongProvince,China ProductSimilarityDeclaration Productname:SmartProjector Modelname:HY350Max,top-2,Gimbal7,Gimbal7Pro, HY350MAX,HY350Ultra FCCID:2BTMB-HY350MAX We(GuangdongHanyingPhotoelectricTechnologyCo.,Ltd)hereby statethatallthemodelsareelectricalidenticalincludingthesame softwareparameterandhardwaredesign(i.e.,circuitdesign,PCB Layout,RFmodule/circuit,antennatype(s)andantennalocation, componentsonPCB,etc.,),samemechanicalstructureanddesign (includingproductenclosure,materials,etc.,),Allsamplesarethe sameexceptthemodelnumber,exteriordesignandexteriorcolor. Signature: Name:GuoyangWang Title:Manager Date:Jan.9,26
GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity, GuangdongProvince,China FCCSoftwareConfigurationControlDeclarationRev1 FCCSoftwareConfigurationControlDeclaration Date:January9,2026 FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Attn:OETDept. Product/ModelNumber:SmartProjector/HY350Max,top-2,Gimbal7,Gimbal7 Pro,HY350MAX,HY350Ultra RegardingFCCCountryCodeSelectionguidelinesidentifiedinKDB594280. “Allapplicationsforequipmentauthorizationfortransmittersthatcanhaveradio parameters,orothertechnicalparameters,reportedtotheCommissionsetbysoftware musthaveanattestationindicatingthatnothirdpartywillhavesoftware,orconfiguration control,toprogramthedeviceoutofcomplianceofthetechnicalrulesunderwhichithas beencertified.” Wedeclarethatnothirdpartywillhavesoftware,orconfigurationcontrol,toprogramthedevice outofcomplianceofthetechnicalrulesunderwhichithasbeencertified. Name:GuoyangWangDate:Jan.9,26 Title:Manager Tel:19117952999 Fax:N/A Email:[email protected]
GuangdongHanyingPhotoelectricTechnologyCo.,Ltd Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity, GuangdongProvince,China 1/9/2026 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BTMB-HY350MAX PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow: BlockDiagram Schematics OperationalDescription PartsList FCCSoftwareSecurityRequirementsforUNIIdevicesRev1.0 Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. PursuanttoDA04-1705,theapplicantalsorequeststemporaryconfidentialtreatmentoftheexhibits outlinedbelowforaperiodof(upto180)daysfromthedateofequipmentauthorizationandpriorto marketingintheUnitedStatestopreventtheprematurereleaseofanysensitiveinformation.Applicantis awareoftheirresponsibilitytonotifyDERYCOMintheeventinformationregardingtheproductorthe productismadeavailabletothepublicbeforetherequestedperiodhasexpired. UserManual InternalPhotos ExternalPhotos TestSetupPhotos Sincerely, Title:Manager Address:Room201,Building3,No.3simalndustrialRoad,ChangpingTown,DongguanCity, GuangdongProvince,China Tel.:19117952999 Email:[email protected]
LabelLocationOnEUT Confirmtheuseofrealappearancephotosasreferences Label
RFEXPOSUREEVALUATION KDB447498D01MobileandPortableDevicesRFExposureProceduresand EquipmentAuthorizationPoliciesv06. AccordingtoFCC1.1310:Thecriterialistedinthefollowingtableshallbeused toevaluatetheenvironmentimpactofhumanexposuretoradiofrequency(RF) Radiationasspecifiedin§1.1307(b) EUTSpecification FCCID2BTMB-HY350MAX EUT SmartProjector Frequencyband(Operating)BT:2.402GHz~2.480GHz WLAN:2.412GHz~2.462GHz RLAN:5.180GHz~5.240GHz RLAN:5.260GHz~5.320GHz RLAN: 5.500 GHz~ 5.700 GHz RLAN:5.745GHz~5.825GHz Others: DevicecategoryPortable(<20cmseparation) Mobile(>20cmseparation) Others___ ExposureclassificationOccupational/Controlledexposure(S=5mW/cm2) GeneralPopulation/Uncontrolledexposure(S=1mW/cm2) AntennadiversitySingleantenna Multipleantennas Txdiversity Rxdiversity Tx/Rxdiversity Antennagain(Max)Wi-Fi2.4G/BT:-3.91dBi Wi-Fi5.2G:4.45dBi Wi-Fi5.8G:2.51dBi EvaluationappliedMPEEvaluation SAREvaluation LimitsforMaximumPermissibleExposure(MPE) Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) Power Density(mW/cm 2 ) Average Time (A)LimitsforOccupational/ControlExposures 300-1500----F/3006 1500-100000----56 (B)LimitsforGeneralPopulation/UncontrolExposures 300-1500----F/15006 1500-100000----130 Friistransmissionformula:Pd=(Pout*G)\(4*pi*R2) Where Pd=PowerdensityinmW/cm 2 Pout=outputpowertoantennainMw G=gainofantennainlinearscale Pi=3.1416 R=distancebetweenobservationpointandcenteroftheradiatorincm PdthelimitofMPE,1mW/cm2.Ifweknowthemaximumgainoftheantenna andtotalpowerinputtotheantenna,throughthecalculation,wewillknowthe distancewheretheMPElimitisreached. MaxMeasurementResult OperatingMode Measured Power Tuneup tolerance Max.Tune upPower Antenna Gain Power densityat 20cm Power densityLimits (mW/cm 2 ) (dBm)(dBm)(dBm)(dBi)(mW/cm 2 ) BDR&EDR3.023.02±14.02-3.910.00021 BLE2.982.98±13.98-3.910.00021 WiFi2.4G15.7315.73±116.73-3.910.00381 WiFi5.2G1616±117.004.450.02781 WiFi5.8G15.8715.87±116.872.510.01731 Result:PASS.
ReportNo.:1812C50634012504-01 Page 1 of 123 AppendixTestData ReportNo.:1812C50634012504-01TestSampleNo.:1-2-2 StartTestDate:2025-12-3FinishTestDate:2025-12-3 TestEngineer:Auditor: Temperature:23.7°CRelativeHumidity:55% Pressure:101kPa AppendixA1:26dBBandwidth TestResult TestModeAntenna Frequency [MHz] 26dbEBW [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11AAnt1518020.2005169.9205190.120------ 11AAnt1522025.0405207.2405232.280------ 11AAnt1524021.0405229.7605250.800------ 11AAnt1574522.2805733.2805755.560------ 11AAnt1578524.8805772.3205797.200------ 11AAnt1582525.4405811.6405837.080------ 11N20SISOAnt1518022.4805168.4805190.960------ 11N20SISOAnt1522020.6805209.6405230.320------ 11N20SISOAnt1524021.8805228.4805250.360------ 11N20SISOAnt1574524.6805731.5605756.240------ 11N20SISOAnt1578528.0405771.3605799.400------ 11N20SISOAnt1582526.3605812.4005838.760------ 11N40SISOAnt1519040.8005169.5205210.320------ 11N40SISOAnt1523041.3605209.2005250.560------ 11N40SISOAnt1575552.9605726.8405779.800------ 11N40SISOAnt1579557.1205765.9605823.080------ 11AC20SISOAnt1518020.5605169.8005190.360------ 11AC20SISOAnt1522020.7605209.5605230.320------ 11AC20SISOAnt1524020.4805229.6805250.160------ 11AC20SISOAnt1574523.0405732.2405755.280------ 11AC20SISOAnt1578527.4005770.0805797.480------ 11AC20SISOAnt1582527.6405812.6805840.320------ 11AC40SISOAnt1519041.2805169.5205210.800------ 11AC40SISOAnt1523041.2005209.2005250.400------ 11AC40SISOAnt1575544.3205731.1605775.480------ ReportNo.:1812C50634012504-01 Page 2 of 123 11AC40SISOAnt1579556.9605768.7605825.720------ 11AX20SISOAnt1518020.4405169.8005190.240------ 11AX20SISOAnt1522020.4805209.8405230.320------ 11AX20SISOAnt1524020.6005229.6005250.200------ 11AX20SISOAnt1574524.5605732.2405756.800------ 11AX20SISOAnt1578527.0005771.2405798.240------ 11AX20SISOAnt1582527.9605811.4805839.440------ 11AX40SISOAnt1519041.3605169.4405210.800------ 11AX40SISOAnt1523041.2805209.4405250.720------ 11AX40SISOAnt1575554.0805725.4805779.560------ 11AX40SISOAnt1579554.8005768.3605823.160------ ReportNo.:1812C50634012504-01 Page 3 of 123 TestGraphs 11A-Ant1-5180 11A-Ant1-5220 ReportNo.:1812C50634012504-01 Page 4 of 123 11A-Ant1-5240 11A-Ant1-5745 ReportNo.:1812C50634012504-01 Page 5 of 123 11A-Ant1-5785 11A-Ant1-5825 ReportNo.:1812C50634012504-01 Page 6 of 123 11N20SISO-Ant1-5180 11N20SISO-Ant1-5220 ReportNo.:1812C50634012504-01 Page 7 of 123 11N20SISO-Ant1-5240 11N20SISO-Ant1-5745 ReportNo.:1812C50634012504-01 Page 8 of 123 11N20SISO-Ant1-5785 11N20SISO-Ant1-5825 ReportNo.:1812C50634012504-01 Page 9 of 123 11N40SISO-Ant1-5190 11N40SISO-Ant1-5230 ReportNo.:1812C50634012504-01 Page 10 of 123 11N40SISO-Ant1-5755 11N40SISO-Ant1-5795 ReportNo.:1812C50634012504-01 Page 11 of 123 11AC20SISO-Ant1-5180 11AC20SISO-Ant1-5220 ReportNo.:1812C50634012504-01 Page 12 of 123 11AC20SISO-Ant1-5240 11AC20SISO-Ant1-5745 ReportNo.:1812C50634012504-01 Page 13 of 123 11AC20SISO-Ant1-5785 11AC20SISO-Ant1-5825 ReportNo.:1812C50634012504-01 Page 14 of 123 11AC40SISO-Ant1-5190 11AC40SISO-Ant1-5230 ReportNo.:1812C50634012504-01 Page 15 of 123 11AC40SISO-Ant1-5755 11AC40SISO-Ant1-5795 ReportNo.:1812C50634012504-01 Page 16 of 123 11AX20SISO-Ant1-5180 11AX20SISO-Ant1-5220 ReportNo.:1812C50634012504-01 Page 17 of 123 11AX20SISO-Ant1-5240 11AX20SISO-Ant1-5745 ReportNo.:1812C50634012504-01 Page 18 of 123 11AX20SISO-Ant1-5785 11AX20SISO-Ant1-5825 ReportNo.:1812C50634012504-01 Page 19 of 123 11AX40SISO-Ant1-5190 11AX40SISO-Ant1-5230 ReportNo.:1812C50634012504-01 Page 20 of 123 11AX40SISO-Ant1-5755 11AX40SISO-Ant1-5795 ReportNo.:1812C50634012504-01 Page 21 of 123 AppendixA2:99%OccupiedBandwidth TestResult TestModeAntennaFrequency[MHz] OCB [MHz] FL[MHz]FH[MHz]Limit[MHz]Verdict 11AAnt1518016.8635171.55455188.4175------ 11AAnt1522017.0305211.45325228.4832------ 11AAnt1524016.8835231.60715248.4901------ 11AAnt1574516.9005736.45065753.3506------ 11AAnt1578516.8965776.53095793.4269------ 11AAnt1582516.9015816.62115833.5221------ 11N20SISOAnt1518017.9325171.06195188.9939------ 11N20SISOAnt1522017.8085211.09815228.9061------ 11N20SISOAnt1524017.9625231.08255249.0445------ 11N20SISOAnt1574517.8625736.02165753.8836------ 11N20SISOAnt1578517.9335776.03555793.9685------ 11N20SISOAnt1582517.8655816.11375833.9787------ 11N40SISOAnt1519036.0485172.01215208.0601------ 11N40SISOAnt1523036.0545211.90815247.9621------ 11N40SISOAnt1575536.2255736.70905772.9340------ 11N40SISOAnt1579536.4805776.70375813.1837------ 11AC20SISOAnt1518017.7415171.16225188.9032------ 11AC20SISOAnt1522017.8315211.06155228.8925------ 11AC20SISOAnt1524017.8465231.04525248.8912------ 11AC20SISOAnt1574517.8695736.02745753.8964------ 11AC20SISOAnt1578518.0065775.96335793.9693------ 11AC20SISOAnt1582517.9075816.07365833.9806------ 11AC40SISOAnt1519036.0845172.02425208.1082------ 11AC40SISOAnt1523036.0985211.93295248.0309------ 11AC40SISOAnt1575536.3865736.56275772.9487------ 11AC40SISOAnt1579536.3825776.78605813.1680------ 11AX20SISOAnt1518017.7725171.15145188.9234------ 11AX20SISOAnt1522017.7405211.11555228.8555------ 11AX20SISOAnt1524017.7685231.09745248.8654------ 11AX20SISOAnt1574517.9275735.96275753.8897------ 11AX20SISOAnt1578517.9165776.02455793.9405------ 11AX20SISOAnt1582517.8705816.10065833.9706------ 11AX40SISOAnt1519036.1315171.96575208.0967------ 11AX40SISOAnt1523036.0425211.91975247.9617------ 11AX40SISOAnt1575536.2515736.65885772.9098------ 11AX40SISOAnt1579536.3405776.81675813.1567------ ReportNo.:1812C50634012504-01 Page 22 of 123 TestGraphs 11A-Ant1-5180 11A-Ant1-5220 ReportNo.:1812C50634012504-01 Page 23 of 123 11A-Ant1-5240 11A-Ant1-5745 ReportNo.:1812C50634012504-01 Page 24 of 123 11A-Ant1-5785 11A-Ant1-5825 ReportNo.:1812C50634012504-01 Page 25 of 123 11N20SISO-Ant1-5180 11N20SISO-Ant1-5220 ReportNo.:1812C50634012504-01 Page 26 of 123 11N20SISO-Ant1-5240 11N20SISO-Ant1-5745 ReportNo.:1812C50634012504-01 Page 27 of 123 11N20SISO-Ant1-5785 11N20SISO-Ant1-5825 ReportNo.:1812C50634012504-01 Page 28 of 123 11N40SISO-Ant1-5190 11N40SISO-Ant1-5230 ReportN…
Text truncated - open the document above for the full version.
ReportNo.:1812C50634012504-01 Page 62 of 123 NTNV-11AC40SISO-Ant1-5190 NTNV-11AC40SISO-Ant1-5230 ReportNo.:1812C50634012504-01 Page 63 of 123 NTNV-11AC40SISO-Ant1-5755 NTNV-11AC40SISO-Ant1-5795 ReportNo.:1812C50634012504-01 Page 64 of 123 NTNV-11AX20SISO-Ant1-5180 NTNV-11AX20SISO-Ant1-5220 ReportNo.:1812C50634012504-01 Page 65 of 123 NTNV-11AX20SISO-Ant1-5240 NTNV-11AX20SISO-Ant1-5745 ReportNo.:1812C50634012504-01 Page 66 of 123 NTNV-11AX20SISO-Ant1-5785 NTNV-11AX20SISO-Ant1-5825 ReportNo.:1812C50634012504-01 Page 67 of 123 NTNV-11AX40SISO-Ant1-5190 NTNV-11AX40SISO-Ant1-5230 ReportNo.:1812C50634012504-01 Page 68 of 123 NTNV-11AX40SISO-Ant1-5755 NTNV-11AX40SISO-Ant1-5795 ReportNo.:1812C50634012504-01 Page 69 of 123 AppendixC:MaximumConductedOutputPower TestResultChannelPower Test Mode AntennaFrequency[MHz]Result[dBm]Limit[dBm]Verdict 11AAnt1518015.23≤23.98PASS 11AAnt1522015.36≤23.98PASS 11AAnt1524015.91≤23.98PASS 11AAnt1574515.87≤30.00PASS 11AAnt1578513.50≤30.00PASS 11AAnt1582514.28≤30.00PASS 11N20SISOAnt1518016.00≤23.98PASS 11N20SISOAnt1522014.94≤23.98PASS 11N20SISOAnt1524015.46≤23.98PASS 11N20SISOAnt1574515.43≤30.00PASS 11N20SISOAnt1578513.43≤30.00PASS 11N20SISOAnt1582514.09≤30.00PASS 11N40SISOAnt1519015.73≤23.98PASS 11N40SISOAnt1523015.21≤23.98PASS 11N40SISOAnt1575515.12≤30.00PASS 11N40SISOAnt1579513.63≤30.00PASS 11AC20SISOAnt1518015.38≤23.98PASS 11AC20SISOAnt1522015.76≤23.98PASS 11AC20SISOAnt1524014.92≤23.98PASS 11AC20SISOAnt1574515.72≤30.00PASS 11AC20SISOAnt1578513.62≤30.00PASS 11AC20SISOAnt1582514.29≤30.00PASS 11AC40SISOAnt1519015.64≤23.98PASS 11AC40SISOAnt1523015.22≤23.98PASS 11AC40SISOAnt1575514.87≤30.00PASS 11AC40SISOAnt1579513.42≤30.00PASS 11AX20SISOAnt1518015.84≤23.98PASS 11AX20SISOAnt1522015.51≤23.98PASS 11AX20SISOAnt1524014.86≤23.98PASS 11AX20SISOAnt1574515.65≤30.00PASS 11AX20SISOAnt1578513.72≤30.00PASS 11AX20SISOAnt1582514.23≤30.00PASS 11AX40SISOAnt1519015.80≤23.98PASS 11AX40SISOAnt1523015.24≤23.98PASS 11AX40SISOAnt1575515.12≤30.00PASS 11AX40SISOAnt1579513.59≤30.00PASS Note:1.Thecablelossarecompensatedinthegraph. ReportNo.:1812C50634012504-01 Page 70 of 123 TestGraphsChannelPower 11A-Ant1-5180-PASS 11A-Ant1-5220-PASS ReportNo.:1812C50634012504-01 Page 71 of 123 11A-Ant1-5240-PASS 11A-Ant1-5745-PASS ReportNo.:1812C50634012504-01 Page 72 of 123 11A-Ant1-5785-PASS 11A-Ant1-5825-PASS ReportNo.:1812C50634012504-01 Page 73 of 123 11N20SISO-Ant1-5180-PASS 11N20SISO-Ant1-5220-PASS ReportNo.:1812C50634012504-01 Page 74 of 123 11N20SISO-Ant1-5240-PASS 11N20SISO-Ant1-5745-PASS ReportNo.:1812C50634012504-01 Page 75 of 123 11N20SISO-Ant1-5785-PASS 11N20SISO-Ant1-5825-PASS ReportNo.:1812C50634012504-01 Page 76 of 123 11N40SISO-Ant1-5190-PASS 11N40SISO-Ant1-5230-PASS ReportNo.:1812C50634012504-01 Page 77 of 123 11N40SISO-Ant1-5755-PASS 11N40SISO-Ant1-5795-PASS ReportNo.:1812C50634012504-01 Page 78 of 123 11AC20SISO-Ant1-5180-PASS 11AC20SISO-Ant1-5220-PASS ReportNo.:1812C50634012504-01 Page 79 of 123 11AC20SISO-Ant1-5240-PASS 11AC20SISO-Ant1-5745-PASS ReportNo.:1812C50634012504-01 Page 80 of 123 11AC20SISO-Ant1-5785-PASS 11AC20SISO-Ant1-5825-PASS ReportNo.:1812C50634012504-01 Page 81 of 123 11AC40SISO-Ant1-5190-PASS 11AC40SISO-Ant1-5230-PASS ReportNo.:1812C50634012504-01 Page 82 of 123 11AC40SISO-Ant1-5755-PASS 11AC40SISO-Ant1-5795-PASS ReportNo.:1812C50634012504-01 Page 83 of 123 11AX20SISO-Ant1-5180-PASS 11AX20SISO-Ant1-5220-PASS ReportNo.:1812C50634012504-01 Page 84 of 123 11AX20SISO-Ant1-5240-PASS 11AX20SISO-Ant1-5745-PASS ReportNo.:1812C50634012504-01 Page 85 of 123 11AX20SISO-Ant1-5785-PASS 11AX20SISO-Ant1-5825-PASS ReportNo.:1812C50634012504-01 Page 86 of 123 11AX40SISO-Ant1-5190-PASS 11AX40SISO-Ant1-5230-PASS ReportNo.:1812C50634012504-01 Page 87 of 123 11AX40SISO-Ant1-5755-PASS 11AX40SISO-Ant1-5795-PASS ReportNo.:1812C50634012504-01 Page 88 of 123 AppendixD:MaximumPowerSpectralDensity TestResultB1 Test Mode AntennaFrequency[MHz] Result [dBm] Limit [dBm/MHz] Verdict 11AAnt151800.56≤11.00PASS 11AAnt152200.87≤11.00PASS 11AAnt152401.28≤11.00PASS 11N20SISOAnt151801.18≤11.00PASS 11N20SISOAnt152200.22≤11.00PASS 11N20SISOAnt152401.06≤11.00PASS 11N40SISOAnt15190-1.96≤11.00PASS 11N40SISOAnt15230-2.39≤11.00PASS 11AC20SISOAnt151800.51≤11.00PASS 11AC20SISOAnt152200.99≤11.00PASS 11AC20SISOAnt152400.22≤11.00PASS 11AC40SISOAnt15190-2.08≤11.00PASS 11AC40SISOAnt15230-2.41≤11.00PASS 11AX20SISOAnt151801.05≤11.00PASS 11AX20SISOAnt152200.68≤11.00PASS 11AX20SISOAnt152400.09≤11.00PASS 11AX40SISOAnt15190-1.91≤11.00PASS 11AX40SISOAnt15230-2.44≤11.00PASS Note:1.Thecablelossarecompensatedinthegraph. ReportNo.:1812C50634012504-01 Page 89 of 123 TestResultB4 Test Mode AntennaFrequency[MHz] Result [dBm/500KHz] Limit [dBm/500KHz] Verdict 11AAnt15745-1.39≤30.00PASS 11AAnt15785-3.63≤30.00PASS 11AAnt15825-3.01≤30.00PASS 11N20SISOAnt15745-1.99≤30.00PASS 11N20SISOAnt15785-4.03≤30.00PASS 11N20SISOAnt15825-3.39≤30.00PASS 11N40SISOAnt15755-5.43≤30.00PASS 11N40SISOAnt15795-6.65≤30.00PASS 11AC20SISOAnt15745-1.74≤30.00PASS 11AC20SISOAnt15785-3.85≤30.00PASS 11AC20SISOAnt15825-3.21≤30.00PASS 11AC40SISOAnt15755-5.30≤30.00PASS 11AC40SISOAnt15795-7.14≤30.00PASS 11AX20SISOAnt15745-1.92≤30.00PASS 11AX20SISOAnt15785-4.01≤30.00PASS 11AX20SISOAnt15825-3.38≤30.00PASS 11AX40SISOAnt15755-5.52≤30.00PASS 11AX40SISOAnt15795-7.03≤30.00PASS Note:1.ThecablelossandRBWFactorarecompensatedinthegraph. 2.Offset=cableloss(2dB)+RBWFactor(2.22dB) ReportNo.:1812C50634012504-01 Page 90 of 123 TestGraphsB1 11A-Ant1-5180-PASS 11A-Ant1-5220-PASS ReportNo.:1812C50634012504-01 Page 91 of 123 11A-Ant1-5240-PASS 11N20SISO-Ant1-5180-PASS ReportNo.:1812C50634012504-01 Page 92 of 123 11N20SISO-Ant1-5220-PASS 11N20SISO-Ant1-5240-PASS ReportNo.:1812C50634012504-01 Page 93 of 123 11N40SISO-Ant1-5190-PASS 11N40SISO-Ant1-5230-PASS ReportNo.:1812C50634012504-01 Page 94 of 123 11AC20SISO-Ant1-5180-PASS 11AC20SISO-Ant1-5220-PASS ReportNo.:1812C50634012504-01 Page 95 of 123 11AC20SISO-Ant1-5240-PASS 11AC40SISO-Ant1-5190-PASS ReportNo.:1812C50634012504-01 Page 96 of 123 1…
Text truncated - open the document above for the full version.
Page 1 of 50 FCC Test Report Report No.:1812C50634012504 Applicant: Guangdong Hanying Photoelectric Technology Co., Ltd Address: Room 201, Building 3, No. 3 sima lndustrial Road, Changping Town, Dongguan City, Guangdong Province, China Product Name:Smart Projector Report Date:2026-01-09 Shenzhen Anbotek Compliance Laboratory Limited #检测章# #资质章# Report No.:1812C50634012504Page 2 of 50 FCC ID: 2BTMB-HY350MAX Contents 1. General Information ...............................................................................................................................6 1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT) ........................................................................................................6 1.3. Auxiliary Equipment Used During Test........................................................................................8 1.4. Operation channel list..................................................................................................................8 1.5. Description of Test Modes...........................................................................................................9 1.6. Measurement Uncertainty ...........................................................................................................9 1.7. Additional Instructions ...............................................................................................................10 1.8. Test Summary ...........................................................................................................................11 1.9. Description of Test Facility ........................................................................................................12 1.10. Disclaimer................................................................................................................................12 1.11. Test Equipment List.................................................................................................................13 2. Conducted Emission at AC power line ................................................................................................15 2.1. EUT Operation ..........................................................................................................................15 2.2. Test Setup .................................................................................................................................15 2.3. Test Data ...................................................................................................................................16 3. Duty Cycle ...........................................................................................................................................18 3.1. EUT Operation ..........................................................................................................................18 3.2. Test Setup .................................................................................................................................18 3.3. Test Data ...................................................................................................................................18 4. Emission bandwidth and occupied bandwidth .....................................................................................19 4.1. EUT Operation ..........................................................................................................................20 4.2. Test Setup .................................................................................................................................21 4.3. Test Data ...................................................................................................................................21 5. Maximum conducted output power......................................................................................................22 5.1. EUT Operation ..........................................................................................................................22 5.2. Test Setup .................................................................................................................................23 5.3. Test Data ...................................................................................................................................23 6. Power spectral density ........................................................................................................................24 6.1. EUT Operation ..........................................................................................................................24 6.2. Test Setup .................................................................................................................................25 6.3. Test Data ...................................................................................................................................25 7. Band edge emissions (Conducted) .....................................................................................................26 7.1. EUT Operation ..........................................................................................................................28 7.2. Test Setup ................................................................................................................…
Text truncated - open the document above for the full version.
7595 Technology Way Ste 100 · Denver, Colorado, 80237 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 39.80 mW |
| 2 | 15E | 5.75 GHz - 5.83 GHz | 38.60 mW |
Smart Projector
Equipment Class
DTS - Digital Transmission SystemSmart Projector
Equipment Class
NII - Unlicensed National Information Infrastructure TXSmart Projector
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter