FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Senxia Technology Co., Ltd/
  3. 2BTPE-AC10

2BTPE-AC10Bluetooth Remote Control Set

Shenzhen Senxia Technology Co., Ltd
Bluetooth Remote Control Set - FCC ID 2BTPE-AC10 - Shenzhen Senxia Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 23, 2025
Application Purpose
Original Equipment
Equipment Note
Bluetooth Remote Control Set
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Senxia Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. * RF warning for Portable device: The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Attestation Statements

Attestation Statements Date: 2025-12-22 TO:Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for(FCC ID:2BTPE-AC10) Shenzhen Senxia Technology Co., Ltdthe undersigned, hereby authorize HOPEK CORPORATION INCto act as our designated U.S. agent for service of process,Shenzhen Senxia Technology Co., Ltdaccepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. HOPEK CORPORATION INCaccepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: Shenzhen Senxia Technology Co., Ltd Contact Name:shengwuzhou Address: 1st Floor, Building 9, Shen'ao Cultural Industry Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Telephone No: 18374521976 Email: [email protected] FRN: 0037755204 Signature: shengwu zhou U.S. Agent Information: Company Name:HOPEK CORPORATION INC Address:16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN:0034562900 Contact Name:Peter Davis Telephone No:561-235-6113 Email:[email protected] Signature: Peter Davis

Attestation Statements

Rev 1/26/2023 Shenzhen Senxia Technology Co., Ltd Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-12-22 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2BTPE-AC10 Shenzhen Senxia Technology Co., Ltd certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Shenzhen Senxia Technology Co., Ltd certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) ( shengwu zhou) Rev 1/26/2023 Shenzhen Senxia Technology Co., Ltd Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2025-12-22 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2BTPE-AC10 Shenzhen Senxia Technology Co., Ltd certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) ( shengwu zhou)

Cover Letter(s)

Manufacture: Shenzhen Senxia Technology Co., LtdAddress: 1st Floor, Building 9, Shen'ao Cultural Industry Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Antenna Specification By Alfred Grau Tested Products.• Antenna 1: integrated antenna. • Frequency = 2.402GHz. • Frequency = 2.441GHz. • Frequency = 2.480GHz. Coordinate System Reference: Antenna 1. Antenna Layout & module on the system board Unit: mm Radiation pattern: Antenna 1. XZ Plane at f = 2.402GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. YZ Plane at f = 2.402GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XY Plane at f = 2.402GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XZ Plane at f = 2.441GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. YZ Plane at f = 2.441GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XY Plane at f = 2.441GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XZ Plane at f = 2.480GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. YZ Plane at f = 2.480GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Radiation pattern: Antenna 1. XY Plane at f = 2.480GHz Co-cross polarization field (dBi) Solid line: vertical polarizationDash line: horizontal polarization Total field (dBi) 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 -15 -20 -20 -25 -25 -30 -30 -35 0 45 90 135 180 225 270 315 0 0 -5 -5 -10 -10 -15 Return Loss: Antenna 1 BW(-10dB) ¡ 13.48% 2 2.2 2.4 2.6 2.8 3 Frequency (GHz) -16-14-12-10 -8-6-4-2 R e t u r n L o s s ( d B ) Measurements summary Frequency (GHz) Plane Return Loss (dB) Polarization Gain max. (dBi) θ for Gain max. φ for Gain max. Antenna 1 2.402 XZ -10.90 Vertical -7.8 290 2.402 XZ -10.90 Horizontal 0.786 182 2.402 YZ -10.90 Vertical 1.21 226 2.402 YZ -10.90 Horizontal -7.75 10 2.402 XY -10.90 Vertical -15.4 20 2.402 XY -10.90 Horizontal 0.93 180 2.441 XZ -12.20 Vertical -7.36 318 2.441 XZ -12.20 Horizontal 1.32 180 2.441 YZ -12.20 Vertical 0.981 204 2.441 YZ -12.20 Horizontal -8.23 24 2.441 XY -12.20 Vertical -14.1 -14 2.441 XY -12.20 Horizontal 1.74 180 2.48 XZ -13.80 Vertical -7.95 312 2.48 XZ -13.80 Horizontal 1.81 186 2.48 YZ -13.80 Vertical 0.204 214 2.48 YZ -13.80 Horizontal -8.38 8 2.48 XY -13.80 Vertical -15.8 12 2.48 XY -13.80 Horizontal 1.87 180

Cover Letter(s)

Differences Description We Shenzhen Senxia Technology Co., Ltd state: Product: Bluetooth Remote Control Set Model(s) Name: AC10, IN002, IN003, AC2023, AC6031, AC5026_1, AC5026_2, AC5026_3 Brand Name: N/A FCC ID: 2BTPE-AC10 All models internal circuit design is the same, only some of the appearance colors are different. Sincerely, Name: shengwu zhou Tel.: 18374521976 Email: [email protected]

Cover Letter(s)

Shenzhen Senxia Technology Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: December 22, 2025 Subject; Request for Confidentiality FCC ID: 2BTPE-AC10 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: shengwu zhou Title: General Manager

Cover Letter(s)

Effective Date: April 2, 2020 QSF 7.6.4-8 – Agent Authorization Letter Template Page 1 of 1 Revision Date: Revision: 0 Shenzhen Senxia Technology Co., Ltd Date:12/22/2025 Product Model Number: AC10 FCC ID:2BTPE-AC10 To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: shengwu zhou Contact Listed on FCC Wesbite Title: General Manager Email: [email protected] On behalf of: Shenzhen Senxia Technology Co., Ltd

External Photos

Page 1 of 4 Report No.: FCS202512102 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Model: AC10 Photo 1 Photo 2 Page 2 of 4 Report No.: FCS202512102 Photo 3 Photo 4 Page 3 of 4 Report No.: FCS202512102 Photo 5 Photo 6 Page 4 of 4 Report No.: FCS202512102 Photo 7 Photo 8

ID Label/Location Info

Label Size: 7mm * 5mm The label is silk-screen on the sample Bluetooth Remote Control Set Model: AC10 FCC ID: 2BTPE-AC10

Internal Photos

Page 1 of 3 Report No.: FCS202512102 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Model: AC10 Photo 1 Photo 2 Page 2 of 3 Report No.: FCS202512102 Photo 3 Photo 4 BLE Antenna Page 3 of 3 Report No.: FCS202512102 Photo 5

RF Exposure Info

FCC Test Report Report No: FCS202512102H01 Issued for Applicant: Shenzhen Senxia Technology Co., Ltd Address: 1st Floor, Building 9, Shen'ao Cultural Industrial Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Product Name: Bluetooth Remote Control Set Brand Name: N/A Model Name: AC10 Series Model: IN002, IN003, AC2023, AC6031, AC5026_1, AC5026_2, AC5026_3 FCC ID: 2BTPE-AC10 Test Standard: FCC 47CFR §2.1093 Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Te c h Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 8 Report No.: FCS202512102H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicant’s Name .................... : Shenzhen Senxia Technology Co., Ltd Address .................................. : 1st Floor, Building 9, Shen'ao Cultural Industrial Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Manufacture's Name ............... : Shenzhen Senxia Technology Co., Ltd Address .................................. : 1st Floor, Building 9, Shen'ao Cultural Industrial Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Product Description Product Name ......................... : Bluetooth Remote Control Set Brand Name ........................... : N/A Model Name ........................... : AC10 Series Model ........................... : IN002, IN003, AC2023, AC6031, AC5026_1, AC5026_2, AC5026_3 Test Standards ........................ : FCC 47CFR §2.1093 447498 D01 Interim General RF Exposure Guidance v06 This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document. Date of Test ............................... : Date (s) of performance of tests : Dec. 04, 2025 ~ Dec. 10, 2025 Date of Issue .............................. : Dec. 10, 2025 Test Result .................................. : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Jack Wang) Page 3 of 8 Report No.: FCS202512102H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TABLE OF CONTENTS 1. GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST FACTORY 6 2. FCC 47CFR §2.1093 REQUIREMENT 7 2.1 TEST STANDARDS 7 2.2 LIMIT 7 2.3 TEST RESULT 8 Page 4 of 8 Report No.: FCS202512102H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Contents 00 Dec. 10, 2025 Initial Issue Page 5 of 8 Report No.: FCS202512102H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name Bluetooth Remote Control Set Brand N/A Model Number AC10 Series Model(s) IN002, IN003, AC2023, AC6031, AC5026_1, AC5026_2, AC5026_3 Model Difference All models internal circuit design is the same, only some of the appearance colors are different. Product Description The EUT is Bluetooth Remote Control Set Operation Frequency: BLE: 2402~2480 MHz Modulation Type: BLE: GFSK Antenna gain: BLE: 1.87dBi Antenna Designation: BLE: PCB Battery DC 3.7V 150mAh Hardware version number V1.0 Software version number V1.0 Page 6 of 8 Report No.: FCS202512102H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1.2 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number:5545.01 ISED Number:25801 CAB ID :CN0097 Page 7 of 8 Report No.: FCS202512102H01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 2. FCC 47CFR §2.1093 REQUIREMENT 2.1 TEST STANDARDS According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1093 RF exposure requirement KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2.2 LIMIT According to KDB447498 D01 General RF Exposure Guidance v06 Section 4.3.1 Standalone SAR test exclusion considerations: “Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition, listed below, is satisfied. These test exclusion cond…

Text truncated - open the document above for the full version.

Test Report

FCC Test Report Report No: FCS202512102W01 Issued for Applicant: Shenzhen Senxia Technology Co., Ltd Address: 1st Floor, Building 9, Shen'ao Cultural Industry Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Product Name: Bluetooth Remote Control Set Brand Name: N/A Model Name: AC10 Series Model: IN002, IN003, AC2023, AC6031, AC5026_1, AC5026_2, AC5026_3 FCC ID: 2BTPE-AC10 Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Te c h Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 51 Report No.: FCS202512102W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicant’s Name ................... : Shenzhen Senxia Technology Co., Ltd Address .................................. : 1st Floor, Building 9, Shen'ao Cultural Industry Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Manufacture's Name .............. : Shenzhen Senxia Technology Co., Ltd Address .................................. : 1st Floor, Building 9, Shen'ao Cultural Industry Park, Dafa Pu Community, Bantian Street, Longgang District, Shenzhen Product Description Product Name ........................ : Bluetooth Remote Control Set Brand Name ........................... : N/A Model Name ........................... : AC10 Series Model .......................... : IN002, IN003, AC2023, AC6031, AC5026_1, AC5026_2, AC5026_3 Test Standards ....................... : FCC Part15.247 Test Procedure ....................... : ANSI C63.10-2020 KDB558074 D01 15.247 Meas Guidance v05r02 This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document. Date of Test ............................... : Date (s) of performance of tests : Dec. 04, 2025 ~ Dec. 10, 2025 Date of Issue .............................. : Dec. 10, 2025 Test Result .................................. : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Jack Wang) Page 3 of 51 Report No.: FCS202512102W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.5 EQUIPMENTS LIST 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 20 4.4 EUT OPERATING CONDITIONS 20 4.5 FIELD STRENGTH CALCULATION 21 4.6 TEST RESULTS 22 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 27 5.1 LIMIT 27 5.2 TEST PROCEDURE 27 5.3 TEST SETUP 27 5.4 EUT OPERATION CONDITIONS 27 5.5 TEST RESULTS 27 6. POWER SPECTRAL DENSITY TEST 28 6.1 LIMIT 28 6.2 TEST PROCEDURE 28 Page 4 of 51 Report No.: FCS202512102W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents 6.3 TEST SETUP 28 6.4 EUT OPERATION CONDITIONS 28 6.5 TEST RESULTS 28 7. BANDWIDTH TEST 29 7.1 LIMIT 29 7.2 TEST PROCEDURE 29 7.3 TEST SETUP 29 7.4 EUT OPERATION CONDITIONS 29 7.5 TEST RESULTS 29 8. PEAK OUTPUT POWER TEST 30 8.1 LIMIT 30 8.2 TEST PROCEDURE 30 8.3 TEST SETUP 31 8.4 EUT OPERATION CONDITIONS 31 8.5 TEST RESULTS 31 9. ANTENNA REQUIREMENT 32 9.1 STANDARD REQUIREMENT 32 9.2 EUT ANTENNA 32 APPENDIX I:TEST RESULTS 33 DUTY CYCLE 33 MAXIMUM PEAK CONDUCTED OUTPUT POWER 36 -6DB BANDWIDTH 39 MAXIMUM POWER SPECTRAL DENSITY LEVEL 42 BAND EDGE 45 CONDUCTED RF SPURIOUS EMISSION 48 Page 5 of 51 Report No.: FCS202512102W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Contents 00 Dec. 10, 2025 Initial Issue Page 6 of 51 Report No.: FCS202512102W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247, Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 51 Report No.: FCS202512102W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building …

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Report No.: FCS202512102 DTS Setup photo Model Number: AC10 DTS radiation L DTS radiation H Page 2 of 2 Report No.: FCS202512102 DTS Conduction

Contact Information

Applicant

shengwu zhou(General Manager)
[email protected]Fax: 18374521976

Technical Contact

HOPEK CORPORATION INC
[email protected]

United States

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.50 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.