FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen Jisu Technology Co., Ltd./
  3. 2BU97-TABLEFANPRO3

2BU97-TABLEFANPRO3Table Fan Pro3 S

Shenzhen Jisu Technology Co., Ltd.
Table Fan Pro3 S - FCC ID 2BU97-TABLEFANPRO3 - Shenzhen Jisu Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 29, 2026
Application Purpose
Original Equipment
Equipment Note
Table Fan Pro3 S
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Jisu Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Manufacturer: Shenzhen Jisu Technology Co., Ltd. Address: Room 2707-2710, Building 4, Phase ll, Tianan Yungu Industrial Park, Gangtou Community, Bantian Street, Longgang District, Shenzhen 518000,CN Web: http://jisulife.com China Domestic Tel: 400-011-8812 Light Color/Wireless Connection Button 01~08 09~15 16~22 23~29 30~36 37~43 44~50 51~57 58~64 14. It is not recommended to use the product on airplanes, including charging it or turning it on. Manual Bedienungsanleitung Manuel d'utilisation Manuale Manual de instrucciones 取扱説明書 الكتيب Manual de instruções Kullanım Kılavuzu USB-C Input Port 17 Wireless connection icon C. Wireless Connection Function When the fan is on, press and hold (1.5s) the light color/wireless connection button to turn the wireless connection on/off, and press and hold (5s) to clear paired devices. When the fan is on, short press the swing button to cycle through 45°, 90°, 120°, and off (return to the initial position); if the fan is turned off during the swing, the swing will return to the initial position; press and hold to directly turn off the swing function and stop at the current position; if the fan is turned off at this point, the swing will stop at the current position. Ambient Light On/Mode Button:Short press to cycle through Constant On, Breathing, Color Gradient, and Off modes; long press to turn off the ambient light directly in any state. Ambient Light Color Button:When the light is in Constant On or Breathing mode, short press to cycle through colors. Double-click the light color/wireless connection button to turn off the current screen display, allowing the fan to run normally; double-click again to restore the screen display. Double-click the swing button to display the current battery percentage. 12 13 14 15 16 17 1 2 3 5 8 4 6 7 9 10 11 D. Swing Function Turn Off Screen Display The screen turns off, and the fan runs normally; if the fan function is adjusted, the screen will light up for 10s and turn off again after no operation. To ensure battery safety, the product has temperature protection features: 1. Charging temperature protection Charging is paused when the temperature is below 0°C or above 45°C, and resumes automatically once the temperature returns to normal. 2. Working (discharge) temperature protection When the temperature is below -20°C or above 60°C, the product will display "H1" and automatically shut down after about 5 seconds. It needs to be manually restarted once the temperature returns to normal. G H I Table Fan Pro3 S This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. -This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Table Fan Pro3 S*1 Table Fan Pro3 S Table Fan Pro3 S 36.5Wh 14.6V

Attestation Statements

Shenzhen Jisu Technology Co., Ltd. Covered Equipment Certification Attestation Letter 6/23/2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2BU97-TABLEFANPRO3 Shenzhen Jisu Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. Shenzhen Jisu Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Shenzhen Jisu Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). <Signature>: Name: Jack Bu Title: Manager Company: Shenzhen Jisu Technology Co., Ltd. Date: 6/23/2026

Attestation Statements

Shenzhen Jisu Technology Co., Ltd. * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter 6/23/2026 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2BU97-TABLEFANPRO3 FRN of applicant: 0038176376 Per section 2.911(d)(7) of the FCC rules, [Shenzhen Jisu Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Herland International Trading Inc FCC Registration Number (FRN): 0036324101 Physical U.S. Company Address: 1370 Valley Vista Dr Ste 200 Diamond Bar, CA 91765 Contact Person: Jianfeng Gao Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Jack bu Title: Manager Company Name: Shenzhen Jisu Technology Co., Ltd. Date: 6/23/2026 Agent Signed (if different from Applicant): Signed: Printed name: Jianfeng Gao Title: Manager Company Name: Herland International Trading Inc Date: 6/23/2026

Cover Letter(s)

Shenzhen Jisu Technology Co., Ltd. 2026-06-23 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen DL Testing Technology Co., Ltd.(101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China)to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Shenzhen Jisu Technology Co., Ltd.(Room 2707-2710, Building 4, Phase ll, Tianan Yungulndustrial Park, Gangtou Community, Bantian Street Longgang District, Shenzhen 518000 China) <Signature>: Name: Jack Bu Title: Manager Company: Shenzhen Jisu Technology Co., Ltd.

Cover Letter(s)

Shenzhen Jisu Technology Co., Ltd. 2026-06-23 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Compliance Testing, LLC to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). Sincerely, <Signature>: Name: Jack Bu Title: Manager Company: Shenzhen Jisu Technology Co., Ltd.

Cover Letter(s)

Shenzhen Jisu Technology Co., Ltd. 2026-06-23 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BU97-TABLEFANPRO3 Product Name: Table Fan Pro3 S Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commission’s rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...)  Schematics  Block diagram  Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature>: Name: Jack Bu Title: Manager Company: Shenzhen Jisu Technology Co., Ltd.

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size:15*12mm M/N: Table Fan Pro3 FCC ID: 2BU97-TABLEFANPRO3 Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ANT Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

RF Exposure Info

FCC ID: 2BU97-TABLEFANPRO3 RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in KDB 447498 D01 V06 and 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. EIRP=EMeas+20log(dMeas)-104.7 EIRP is the equivalent isotropically radiated power, in dBm EMeas is the field strength of the emission at the measurement distance, in dBμV/m dMeas is the measurement distance, in m Test Result of RF Exposure Evaluation BLE mode Channel Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 2402 2.64 1.8 0.0002 1.0 PASS Remark: antenna gain=-3.15dBi

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260327031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 33 FCC Part 15C Test Report FCC ID: 2BU97-TABLEFANPRO3 Applicant: Shenzhen Jisu Technology Co., Ltd. Address: Room 2707-2710, Building 4, Phase ll, Tianan Yungulndustrial Park, Gangtou Community, Bantian Street Longgang District, Shenzhen 518000 China Manufacturer: Shenzhen Jisu Technology Co., Ltd. Address: Room 2707-2710, Building 4, Phase ll, Tianan Yungulndustrial Park, Gangtou Community, Bantian Street Longgang District, Shenzhen 518000 China Product Name: Table Fan Pro3 S Trade Mark: N/A Model Number: Table Fan Pro3 S Date of Receipt: Mar. 27, 2026 Test Date: Mar. 27, 2026 - Apr. 17, 2026 Date of Report: Apr. 17, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10:2020+Cor.1:2023 Test Result: Pass Report Number: DLE-260327031R Prepared (Test Engineer): Alisa Song Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260327031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 33 Table of Contents Page 1. . SUMMARY OF TEST RESULTS 4 1.1. MEASUREMENT UNCERTAINTY 4 2. . GENERAL INFORMATION 5 2.1. GENERAL DESCRIPTION OF EUT 5 2.2. DESCRIPTION OF TEST MODES 6 2.3. BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4. DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 7 2.5. TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 7 2.6. EQUIPMENTS LIST FOR ALL TEST ITEMS 8 3. . EMC EMISSION TEST 9 3.1. CONDUCTED EMISSION MEASUREMENT 9 3.1.1. POWER LINE CONDUCTED EMISSION LIMITS 9 3.1.2. TEST PROCEDURE 9 3.1.3. DEVIATION FROM TEST STANDARD 9 3.1.4. TEST SETUP 10 3.1.5. EUT OPERATING CONDITIONS 10 3.1.6. TEST RESULTS 11 3.2. RADIATED EMISSION MEASUREMENT 13 3.2.1. RADIATED EMISSION LIMITS 13 3.2.2. TEST PROCEDURE 14 3.2.3. DEVIATION FROM TEST STANDARD 14 3.2.4. TEST SETUP 14 3.2.5. EUT OPERATING CONDITIONS 15 3.2.6. TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 16 3.2.7. TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 17 3.2.8. TEST RESULTS (1GHZ~25GHZ) 19 3.3 RADIATED BAND EMISSION MEASUREMENT 20 3.3.1 TEST REQUIREMENT: 20 3.3.2 TEST PROCEDURE 20 3.3.3 DEVIATION FROM TEST STANDARD 20 3.3.4 TEST SETUP 21 3.3.5 EUT OPERATING CONDITIONS 21 3.4 CONDUCTED BAND EDGE EMISSION&CONDUCTED SPURIOUS EMISSIONS MEASUREMENT 23 3.4.1 APPLICABLE STANDARD 23 3.4.2 TEST PROCEDURE 23 3.4.3 DEVIATION FROM STANDARD 23 3.4.4 TEST SETUP 23 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260327031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 33 Table of Contents Page 3.4.5 EUT OPERATION CONDITIONS 23 3.4.6 TEST RESULTS 23 4. . PEAK OUTPUT POWER 26 4.1. APPLIED PROCEDURES / LIMIT 26 4.1.1. TEST PROCEDURE 26 4.1.2. DEVIATION FROM STANDARD 26 4.1.3. TEST SETUP 26 4.1.4. EUT OPERATION CONDITIONS 26 4.1.5. TEST RESULTS 27 5. . POWER SPECTRAL DENSITY TEST 29 5.1. APPLIED PROCEDURES / LIMIT 29 5.1.1. TEST PROCEDURE 29 5.1.2. DEVIATION FROM STANDARD 29 5.1.3. TEST SETUP 29 5.1.4. EUT OPERATION CONDITIONS 29 5.1.5. TEST RESULTS 29 6. . 6DB BANDWIDTH TEST 31 6.1. APPLIED PROCEDURES / LIMIT 31 6.1.1. TEST PROCEDURE 31 6.1.2. DEVIATION FROM STANDARD 31 6.1.3. TEST SETUP 31 6.1.4. EUT OPERATION CONDITIONS 31 6.1.5. TEST RESULTS 31 7. . ANTENNA REQUIREMENT 33 7.1. STANDARD REQUIREMENT 33 7.2. EUT ANTENNA 33 8. . TEST SEUUP PHOTO 33 9. . EUT PHOTO 33 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260327031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 33 1.. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS 15.205, 15.209, 15.247(d) Radiated Spurious Emission PASS 15.209, 15.205 Band Edge Emission PASS 15.247(b) Peak Output Power PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(e) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Test lab: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China FCC Test Firm Registration Number: 854456 Designation Number: CN1307 IC Registered No.: 27485 CAB ID.: CN0118 1.1. MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 6dB Bandwidth ±0.2MHz 9 Power Spectral Density ±0.3dBm Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260327031R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 33 2.. GENERAL INFORMATION 2.1. GENERAL DESCRIPTION OF EUT Product Name: Table Fan Pro3 S Trade Mark: N/A Model Number: Table Fan Pro3 Test Model: Table Fan Pro3 Model Difference: N/A Operation Frequency: 2402~2480MHz Channel numbers: 40 Channels Channel separation: 2MHz Data Rate: 1Mbps Modulation technology: GFSK Antenna Type: Internal Antenna Antenna gain: -3.15 dBi Power supply: DC 5V from charger DC 14.6V from battery Note:…

Text truncated - open the document above for the full version.

Test Report

版本:R-A生效日期:202 5-12-29 第 1 页 共 4 页 深圳市华讯视通科技有限公司 ShenzhenHuaxunshitongTechnologyCo.,Ltd. Antenna Specification Document Address: Building 43, Zhongwu Industrial Zone, Bao'an District, Shenzhen City 版本:R-A生效日期:202 5-12-29 第 2 页 共 4 页 1.Testing items and equipment Testing itemsEquipment 1. S参 数 (S-parameter) 1.回波损耗(ReturnLoss) 2.电压驻波比(VSWR) 网络分析仪:AgilentE5071B HP8753D 2.有源测试 (Active) 1.发射功率(TRP) 2.接收灵敏度(TIS) 1.暗室:ETS7x4x3m(3D)Chamber ETS5x3x3m(3D)Chamber 2.综合测试仪:Agilent8960E5515B×2 StarPointSP6011 3.无源测试 (Passive) 1.天线增益(Gain)2.天线效 率 (Efficiency) 1.暗室:ETS7x4x3m(3D)Chamber ETS5x3x3m(3D)Chamber 2.网络分析仪:AgilentE5071B HP8753D 2.匹配电路-BT天线: 我司未对匹配电路做任何修 版本:R-A生效日期:202 5-12-29 第 3 页 共 4 页 3 Efficiency and Gain 版本:R-A生效日期:2025-12-29 第 4 页 共 4 页 5 Structural drawing

Test Setup Photos

Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos Shenzhen DL Testing Technology Co., Ltd. Conducted Measurement Photos ※※※※※ END OF REPORT ※※※※※

Contact Information

Applicant

Jack bu
[email protected]Fax: 18906679427

Technical Contact

Herland International Trading IncJianfeng Gao
[email protected]

1370 Valley Vista Dr Ste 200 Diamond Bar, CA 91765 · Diamond Bar, California · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.80 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. This equipment should be installed and operated with minimum 20cm between the radiator and your body. This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter.