Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MONKEY Manual MONKEY is an ultra-portable and versatile 2-octave Bluetooth MIDI keyboard. For further support, please email us or join our discord server. Hardware overview MONKEY features a 2-octave keybed starting on the F-key. Play it as a typical MIDI keyboard, or access its extended capabilities through the SHIFT key. Functions The functions are organized into groups. The functions highlighted with a white circle are the MIDI effects, going from ARP to DRM. The functions to the left of these effects are general settings, and to the right, we have the loop recorder + WAKE. Each of the functions has a simple interface. There are two types of functions: 1. Function is directly applied by pressing the key 2. Function is applied after pressing the key followed by a sequence of numbers using the numbered keys Furthermore each function might also have a long press function. When prompted to type in numbers for a long press function, the light tower will blink but with a different blink pattern than with a normal press blink pattern. This way you can distinguish whether you are about to do a normal press action or a long press action. The long press action is activated if you keep a function key pressed for more than 1 second. Below you can see a table of how each of the functions behave, according to the two function types listed above. The light tower will directly indicate what you should do or what happened. For the function which toggle (HOLD and the effects) the light tower will blink once when activating and blink twice when deactivating. WAKE The first function you should get familiar with is the WAKE key. Pressing SHIFT + WA K E will reset the device, and SHIFT + long pressing WAKE reboots the device. If you ever get lost, use WAKE to quickly reset the device state back to it’s default state. Show - reset demo Show - reboot demo OCT- and OCT+ OCT- and OCT+ are the most straightforward functions as they only change the octave range of the keybed. OCT- decrements the current octave while OCT+ increments the current octave. The light tower will blink once when you change the octave. When you hit the octave limits it will blink 4 times indicating it is unable to increment or decrement any further. Show - octave select demo BPM BPM stands for beats per minute and lets you change the global tempo of MONKEY. WHile pressing SHIFT, press BPM followed by typing your desired BPM using the numbered keys. By default the BPM on MONKEY is 120. Show - BPM select demo CH To use MONKEY with multiple instruments at the same time, you can configure each instrument to receive notes on different channels. Then you can use the CH function on MONKEY to change between these instruments. While pressing SHIFT, press CH followed by your desired channel. Selecting 0 corresponds to MIDI channel 10. CAUTION: Make sure to distinguish between a short press and long press on CH key. Long pressing CH allows you to mute/unmute specific MIDI channels. Use the numbered keys to select the channels which you would like to mute/unmute. This is useful paired together with the loop recorder, muting parts of your loop. Show - channel select demo HOLD Toggle note hold using the HOLD function. Notice the light tower LED blinking once if the function was enabled and twice if it was disabled. Show - hold demo MIDI effects MONKEY has in total 6 MIDI effects each with 10 presets. Similarly to HOLD, the effects are toggled on and off. Only one effect might be enabled at once. • If you enable a new effect and a previous effect was enabled, this new effect will be enabled and the previous disabled. • If you press on the effect which is already enabled, it will disable and no effects will be enabled. Once an effect is enabled, you can change its preset. This is simply done by directly pressing the numbered keys while in SHIFT mode. Show - effect select demo Show - effect preset select demo ARP Arpeggio effect. Presets change the arpeggio algorithm. DBL Double effect. For each key you press, this effect will add extra notes. The presets change which notes are added and with what delay. STTR Stutter effect. Plays the notes which are pressed in a rhythmic pattern. The presets change the pattern. ECHO The echo effect will repeat the notes you play in a feedback loop. The behavior of each preset is varied and unconventional by design. Some presets have an infinite feedback loop where the note is not removed from the loop until the velocity of the key reaches 0. PAT Pattern effect. Pre-made note patterns. Preset changes the swing. DRM Drum effect. The bottom keys are drum loops and the upper keys are drum modifiers. Manage and edit your drum loops through our device utility page. Loop recorder The loop recorder is your playground to combine recordings from multiple instruments into an idea. Currently, the loop recorder is fixed with a length of 16 beats. The loop recorder uses the following keys: • PLAY: Toggle on and off loop playback. The monkey LEDs will blink in tempo during playback. • REC: Toggle on and off loop recording. The behavior of this key depends on if the loop is currently playing or not. If it is not playing, it will toggle on and off “arm to record.” The monkey LEDs will then be solid. As soon as you start playing on the keys, the looper will start playing and recording. If the looper is already playing, then recording will be toggled on and off. Notice how the monkey LEDs blink differently between only playback and playback with recording. When recording, the LEDs will remain lit longer. • UNDO: Every time you stop recording, a new record checkpoint is generated. Pressing UNDO will erase the last checkpoint. Long pressing UNDO will allow you to select an entire MIDI channel to erase. After SHIFT + long press UNDO, while keeping SHIFT pressed, select the MIDI channel to erase by pressing a corresponding numbered key. As always, the number 0 is MIDI channel 10 and is reserved for the drums. Recommendations It’s a good idea …
Text truncated - open the document above for the full version.
Wavy Industries AS, org nr. 935955335 Federal Communica/ons Commission Authoriza/on and Evalua/on Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026/2/25 Ref: AKesta/on Statements Part 2.911(d)(7) Filing FCC ID: 2BUD6-WIMKYOO1 Applicant FRN: 0037865631 [Wavy Industries AS, org nr. 935955335] cer/fies that, as of the date of the filing of the applica/on, [FCC US Agent, LLC] is our designated U.S. agent for service of process for the above referenced FCC ID. [Wavy Industries AS, org nr. 935955335] accepts to maintain an agent for no less than one year aVer the grantee has terminated all marke/ng and importa/on or the conclusion of any Commission-related proceeding involving the equipment. [FCC US Agent, LLC] accepts, as of the date of the filing of the applica/on, the obliga/on of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Informa/on: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Sincerely, [Wavy Industries AS, org nr. 935955335]FCC US Agent, LLC [Rein Gundersen Bentdal] Tim Payne Rev 1/26/2023
(Wavy Industries AS, org nr. 935955335) (2026/4/24) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for (FCC ID: 2BUD6-WIMKYOO1) [Wavy Industries AS, org nr. 935955335] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Rein Gundersen Bentdal (Wavy Industries AS, org nr. 935955335) (2026/4/24) Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for (FCC ID: 2BUD6-WIMKYOO1) [Wavy Industries AS, org nr. 935955335] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Rein Gundersen Bentdal
Wavy Industries AS, org nr. 935955335 2026/2/25 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title : Rein Gundersen Bentdal / Manager Contact information / address: Suttestadvegen 6, 2613 Lillehammer, Norway
Wavy Industries AS, org nr. 935955335 2026/2/25 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: MONKEY Trademark: N/A MODEL: WIMKYOO1 FCC ID: 2BUD6-WIMKYOO1 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the -Block Diagram -Schematics -Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title : Rein Gundersen Bentdal / Manager Contact information / address: Suttestadvegen 6, 2613 Lillehammer, Norway
EFGX26010012-IE-01-External Photos 1 / 4 External Photos Model Name: WIMKYOO1 EFGX26010012-IE-01-External Photos 2 / 4 EFGX26010012-IE-01-External Photos 3 / 4 EFGX26010012-IE-01-External Photos 4 / 4
Location: Label FCC ID: 2BUD6-WIMKYOO1
EFGX26010012-IE-01-Internal Photos 1 / 3 Internal Photos Model Name: WIMKYOO1 EFGX26010012-IE-01-Internal Photos 2 / 3 Internal Photos EFGX26010012-IE-01-Internal Photos 3 / 3 Antenna
Radio frequency radiation exposure evaluation: portable devices RESULT : Pass Test Specification Test item : MONKEY Identification / Type No. : WIMKYOO1 FCC ID : 2BUD6-WIMKYOO1 Test standard : CFR47 FCC Part 2: Section 2.1093 FCC KDB Publication 447498 D04 Calculation Method according to KDB 447498 D04 and f is in GHz, d is the separation distance (cm), and ERP20cm is per Formula (B.1). The example values shown in Table B.2 are for illustration only. FCC Measurement Record: Test Mode Conducted Power (dBm) Conducted Power (mW) ERP (dBm) ERP (mW) Minimum Separation Distances (mm) Limit (mW) BLE -3.16 0.483 -1.41 0.722 5 2.72
EUROFINS ELECTRICAL TESTING SERVICE (SHENZHEN) CO., LTD. RADIO TEST - REPORT FCC Compliance Test Report for Product name: MONKEY Model name: WIMKYOO1 FCC ID: 2BUD6-WIMKYOO1 Test Report Number: EFGX26010012-IE-01-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Phone: +86-0755-829118671 Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8 Fax: +86-0755-82910749 Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 1 of 26 1 General Information 3 1.1 Notes 3 1.2 Testing laboratory 4 1.3 Details of applicant 4 1.4 Details of manufacturer 4 1.5 Application details 5 1.6 Test item 5 1.7 Test standards 6 2 Technical test 7 2.1 Summary of test results 7 2.2 Test environment 7 2.3 Measurement uncertainty 7 2.4 Test mode 8 2.5 Test equipment utilized 9 2.6 Auxiliary equipment used during test 10 2.7 Test software information 10 2.8 Test setup 11 2.9 Test results 13 3 Technical Requirement 14 3.1 Conducted emission AC power port 14 3.2 Duty cycle 15 3.3 6dB bandwidth 16 3.4 99% Occupied Bandwidth 17 3.6 Conducted Peak output power 18 3.7 Power spectral density 19 3.8 Conducted Spurious Emissions 20 3.9 Band edge 21 3.10 Spurious radiated emissions for transmitter 24 4 Test Setup Photos 26 5 External Photo 26 6 Internal Photos 26 7 Appendix 26 Test Report No.: EFGX26010012-IE-01-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 3 of 26 1 General Information 1.1 Notes The results of this test report relate exclusively to the item tested as specified in chapter “Description of test item” and are not transferable to any other test items. Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Is not responsible for any generalisations and conclusions drawn from this report. Any modification of the test item can lead to invalidity of test results and this test report may therefore be not applicable to the modified test item. The test report may only be reproduced or published in full. Reproducing or publishing extracts of the report requires the prior written approval of the Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. This document is subject to the General Terms and Conditions and the Testing and Certification System of Eurofins Electrical Testing Service (Shenzhen) Co., Ltd., available on request or accessible at www.eurofins.com. Operator: 2026-01-05 Bruce Zheng / Project Engineer Date Eurofins-Lab. Name / Title Signature Technical responsibility for area of testing: 2026-01-05 Albert Xu / Lab Manager Date Eurofins-Lab. Name / Title Signature Test Report No.: EFGX26010012-IE-01-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 4 of 26 1.2 Testing laboratory Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Telephone : +86-755-82911867 Fax : +86-755-82910749 The Laboratory has passed the Accreditation by the American Association for Laboratory Accrediation (A2LA). The Accreditation number is 5376.01 The Laboratory has been listed by industry Canada to perform electromagnetic emission measurements, The CAB identifier is CN0088 1.3 Details of applicant Name : Wavy Industries AS, org nr. 935955335 Address : Suttestadvegen 6, 2613 Lillehammer, Norway Telephone : +4748114725 Fax : / 1.4 Details of manufacturer Name : Wavy Industries AS, org nr. 935955335 Address : Suttestadvegen 6, 2613 Lillehammer, Norway Telephone : +4748114725 Fax : / 1.5 Details of factory Name : Wavy Industries AS, org nr. 935955335 Address : Suttestadvegen 6, 2613 Lillehammer, Norway Telephone : +4748114725 Fax : / Test Report No.: EFGX26010012-IE-01-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 5 of 26 1.6 Application details Date of receipt of application : 2025-12-23 Date of receipt of test item : 2025-12-23 Date of test : 2025-12-23 to 2026-01-05 Date of issue : 2026-01-05 1.7 Test item Product type : MONKEY Test Model : WIMKYOO1 Sample ID : 260104-14-001 Brand : N/A Serial number : N/A Hardware Version : WIMKY001 Software / Firmware Version : 1.2.0 Ratings : 3V Test voltage : 3V RadioTechnical data Frequency range : 2402MHz – 2480MHz Radio Tech. : Bluetooth Low Energy Frequency channel : 40 Channels Modulation : GFSK 1Mbps Antenna type : PCB antenna Maximum antenna gain : 3.9dBi Additional information : N/A The above sample(s) and sample information was/were submitted and identified on behalf of the applicant. Eurofins assures objectivity and impartiality of the test, and fulfills the obligation of confidentiality for applicant’s commercial infor- mation and technical documents. Test Report No.: EFGX26010012-IE-01-E01 Eurofins Electrical Testing Service (Shenzhen) Co., Ltd. Room 20 of 2/F., 1/F., Building 2, Spring Block & Room 102, Building 8, Autumn Block, Meishenghuigu Innovation Park, No.83, Dabao Road, Bao’an District, Shenzhen, Guangdong, China Page 6 of 26 1.8 Test standards Test Standards FCC Part 15 Subpart C PART 15 – RADIO FREQUENCY DEVICES Subpart C – Intentional Radiators Test Method 1: ANSI C63.4-2014, American National Standard for Methods of Measurement of Radio-Noise Emis- sions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. 2: ANSI C63.10-2020, American National Standard for Testing Unlicensed Wireless Devi…
Text truncated - open the document above for the full version.
Appendix A: DTS Bandwidth Test Result TestMode Antenna Frequency[MHz] DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.692 2401.648 2402.340 0.5 PASS BLE_1M Ant1 2440 0.704 2439.656 2440.360 0.5 PASS BLE_1M Ant1 2480 0.748 2479.640 2480.388 0.5 PASS Test Graphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS BLE_1M-Ant1-2480-PASS Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Frequency[MHz] OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0441 2401.4799 2402.5240 --- --- BLE_1M Ant1 2440 1.0871 2439.4596 2440.5467 --- --- BLE_1M Ant1 2480 1.0714 2479.4682 2480.5396 --- --- Test Graphs BLE_1M-Ant1-2402 BLE_1M-Ant1-2440 BLE_1M-Ant1-2480 Appendix C: Maximum conducted output power Test Result Peak TestMode Antenna Frequency[MHz] Conducted Peak Power[dBm] Conducted Limit[dBm] EIRP[dBm] EIRP Limit[dBm] Verdict BLE_1M Ant1 2402 -4.59 ≤30 -0.69 ≤36 PASS BLE_1M Ant1 2440 -3.16 ≤30 0.74 ≤36 PASS BLE_1M Ant1 2480 -3.27 ≤30 0.63 ≤36 PASS Note: EIRP=Conducted Peak Power+Antenna Gain(3.9dBi). Test Graphs Peak BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS BLE_1M-Ant1-2480-PASS Appendix D: Maximum power spectral density Test Result TestMode Antenna Frequency[MHz] Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -17.27 ≤8.00 PASS BLE_1M Ant1 2440 -16.13 ≤8.00 PASS BLE_1M Ant1 2480 -17.26 ≤8.00 PASS Test Graphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2440-PASS BLE_1M-Ant1-2480-PASS Appendix E: Band edge measurements Test Result TestMode Antenna ChName Frequency[ MHz] RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 -5.60 -50.24 ≤-25.6 PASS BLE_1M Ant1 High 2480 -3.93 -49.9 ≤-23.93 PASS Test Graphs BLE_1M-Ant1-2402-PASS BLE_1M-Ant1-2480-PASS Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Frequency [MHz] FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 0~Reference -6.75 -6.75 --- PASS BLE_1M Ant1 2402 30~1000 -6.75 -62.56 ≤-26.75 PASS BLE_1M Ant1 2402 1000~26500 -6.75 -53.55 ≤-26.75 PASS BLE_1M Ant1 2440 0~Reference -4.91 -4.91 --- PASS BLE_1M Ant1 2440 30~1000 -4.91 -62.41 ≤-24.91 PASS BLE_1M Ant1 2440 1000~26500 -4.91 -48.86 ≤-24.91 PASS BLE_1M Ant1 2480 0~Reference -4.49 -4.49 --- PASS BLE_1M Ant1 2480 30~1000 -4.49 -62.64 ≤-24.49 PASS BLE_1M Ant1 2480 1000~26500 -4.49 -49.34 ≤-24.49 PASS Test Graphs BLE_1M-Ant1-2402-0~Reference-PASS BLE_1M-Ant1-2402-30~1000-PASS BLE_1M-Ant1-2402-1000~26500-PASS BLE_1M-Ant1-2440-0~Reference-PASS BLE_1M-Ant1-2440-30~1000-PASS BLE_1M-Ant1-2440-1000~26500-PASS BLE_1M-Ant1-2480-0~Reference-PASS BLE_1M-Ant1-2480-30~1000-PASS BLE_1M-Ant1-2480-1000~26500-PASS Appendix G: Duty Cycle Test Result TestMode Antenna Frequency[MHz] ON Time [ms] Period [ms] Duty Cycle [%] BLE_1M Ant1 2402 2.12 6.99 30.33 BLE_1M Ant1 2440 2.12 6.99 30.33 BLE_1M Ant1 2480 2.12 6.99 30.33 Test Graphs NTNV-BLE_1M-Ant1-2402 NTNV-BLE_1M-Ant1-2440 NTNV-BLE_1M-Ant1-2480 Appendix H: Emissions in Restricted Bands-Left Test Result Mode: BLE 1M-2402 Final Data List NO. Frequency [MHz] Factor [dB] PK Reading [dBμV/ m] PK Value [dBμV/m] PK Limit [dBμV/m] PK Margin [dB] AV Reading [dBμV/ m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Height [cm] Angle [°] Polarity Verdict 1 2310.0000 4.67 37.32 41.99 74.00 32.01 34.80 39.47 54.00 14.53 100 315 Horizontal PASS 2 2322.4300 4.87 38.96 43.83 74.00 30.17 36.80 41.67 54.00 12.33 100 87 Horizontal PASS 3 2337.0600 4.81 38.54 43.35 74.00 30.65 35.27 40.08 54.00 13.92 100 215 Horizontal PASS 4 2353.1200 4.96 38.64 43.60 74.00 30.40 36.81 41.77 54.00 12.23 100 289 Horizontal PASS 5 2377.8700 5.08 40.87 45.95 74.00 28.05 37.52 42.60 54.00 11.40 100 21 Horizontal PASS 6 2390.0000 4.95 38.69 43.64 74.00 30.36 36.05 41.00 54.00 13.00 100 61 Horizontal PASS Final Data List NO. Frequency [MHz] Factor [dB] PK Reading [dBμV/ m] PK Value [dBμV/m] PK Limit [dBμV/m] PK Margin [dB] AV Reading [dBμV/ m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Height [cm] Angle [°] Polarity Verdict 1 2310.0000 4.67 37.55 42.22 74.00 31.78 34.47 39.14 54.00 14.86 100 65 Vertical PASS 2 2320.8900 4.91 38.9 43.81 74.00 30.19 35.87 40.78 54.00 13.22 100 332 Vertical PASS 3 2341.0200 4.87 39.23 44.10 74.00 29.90 36.76 41.63 54.00 12.37 100 46 Vertical PASS 4 2347.4000 4.93 38.66 43.59 74.00 30.41 36.96 41.89 54.00 12.11 100 106 Vertical PASS 5 2363.1300 4.92 38.87 43.79 74.00 30.21 37.52 42.44 54.00 11.56 100 334 Vertical PASS 6 2390.0000 4.95 37.78 42.73 74.00 31.27 36.19 41.14 54.00 12.86 100 328 Vertical PASS Mode: BLE 1M-2480 Final Data List NO. Frequency [MHz] Factor [dB] PK Reading [dBμV/ m] PK Value [dBμV/m] PK Limit [dBμV/m] PK Margin [dB] AV Reading [dBμV/ m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Height [cm] Angle [°] Polarity Verdict 1 2483.5000 5.46 41.54 47.00 74.00 27.00 41.33 46.79 54.00 7.21 100 71 Horizontal PASS 2 2484.5803 5.51 42.59 48.10 74.00 25.90 42.46 47.97 54.00 6.03 100 64 Horizontal PASS 3 2487.9377 5.46 39.08 44.54 74.00 29.46 38.96 44.42 54.00 9.58 100 60 Horizontal PASS 4 2490.9353 5.55 38.92 44.47 74.00 29.53 38.81 44.36 54.00 9.64 100 130 Horizontal PASS 5 2496.3149 5.57 38.45 44.02 74.00 29.98 38.32 43.89 54.00 10.11 100 60 Horizontal PASS 6 2500.0000 5.50 37.35 42.85 74.00 31.15 36.70 42.20 54.00 11.80 100 360 Horizontal PASS Final Data List NO. Frequency [MHz] Factor [dB] PK Reading [dBμV/ m] PK Value [dBμV/m] PK Limit [dBμV/m] PK Margin [dB] AV Reading [dBμV/ m] AV Value [dBμV/m] AV Limit [dBμV/m] AV Margin [dB] Height [cm] Angle [°] Polarity Verdict 1 2483.5000 5.46 38.85 44.31 74.00 29.69 38.81 44.27 54.00 9.73 100 43 Vertical PASS 2 2487.0743 5.53 38.49 44.02 74.00 29.98 38.27 43.80 54.00 10.20 100 20 Vertical PASS 3 2491.3030 5.55 38.57 44.12 74.00 29.88 38.31 43.86 54.00 10.14 100 157 Vertical PASS 4 2494.4764 5.58 39.19 44.77 74.00 29.23 39.08 44.66 54.00 9.34 100 47 Vertical PASS 5 2498.3373 5.55 38.45 44.00 74.00 30.00 38.30 43.85 54.00 10.15 100 337 Vertical PASS 6 2500.0000 5.50 37.23 42.73 74.00 31.27 37.16 42.66 54.0…
Text truncated - open the document above for the full version.
Report No.: Ti-EE26030726-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 1 / 14 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China TEST REPORT Applicant: Wavy Industries AS, org nr. 935955335 Address: Suttestadvegen 6, 2613 Lillehammer Norway Equipment Type: MONKEY Model Name: WIMKYOO1 Brand Name: N/A Test Standard: IEEE Std 149-2021 Sample Arrival Date: Mar. 26, 2026 Test Date: Mar. 27, 2026 Date of Issue: Apr. 23, 2026 ISSUED BY: Shenzhen BALUN Technology Co., Ltd. Tested by: Mai Jintian Checked by: Xia Long Approved by: Tolan Tu (Technical Director) _______________ _______________ _______________ Report No.: Ti-EE26030726-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 2 / 14 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China Revision History Version Issue Date Revisions Rev. 01 Apr. 23, 2026 Initial Issue TABLE OF CONTENTS 1 GENERAL INFORMATION ........................................................................................................ 3 1.1 Test Laboratory .................................................................................................................. 3 1.2 Test Location ...................................................................................................................... 3 2 PRODUCT INFORMATION ....................................................................................................... 4 2.1 Applicant Information .......................................................................................................... 4 2.2 Manufacturer Information .................................................................................................... 4 2.3 General Description for Equipment under Test (EUT) ......................................................... 4 2.4 Ancillary Equipment ............................................................................................................ 4 3 SUMMARY OF TEST RESULTS ............................................................................................... 5 3.1 Test Standards ................................................................................................................... 5 3.2 Test Verdict ........................................................................................................................ 5 3.3 Test Uncertainty ................................................................................................................. 5 4 GENERAL TEST CONFIGURATIONS ...................................................................................... 6 4.1 Test Condition .................................................................................................................... 6 4.2 Test Equipment List ............................................................................................................ 6 4.3 Test Setup .......................................................................................................................... 7 4.4 Test Frequencies ................................................................................................................ 7 ANNEX A TEST RESULTS .......................................................................................................... 8 A.1 Gain and Efficiency ............................................................................................................. 8 A.2 VSWR ................................................................................................................................. 9 ANNEX B RADIATION PATTERN ............................................................................................. 10 ANNEX C TEST SETUP PHOTOS ............................................................................................ 13 ANNEX D EUT PHOTO.............................................................................................................. 13 Report No.: Ti-EE26030726-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 3 / 14 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1 GENERAL INFORMATION 1.1 Test Laboratory Name Shenzhen BALUN Technology Co., Ltd. Address Building 2, Intelligent Connected Vehicle Industrial Park, No. 55, Xiangshan Road, Luotian Community, Yanluo Sub-district, Bao'an District, Shenzhen, Guangdong Province, China Phone Number +86 755 6685 0100 1.2 Test Location Name Shenzhen BALUN Technology Co., Ltd. Location Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 1/F, Building B, Ganghongji High-tech Intelligent Industrial Park, No. 1008, Songbai Road, Yangguang Community, Xili Sub-district, Nanshan District, Shenzhen, Guangdong Province, P. R. China Building 2, Intelligent Connected Vehicle Industrial Park, No. 55, Xiangshan Road, Luotian Community, Yanluo Sub-distict Report No.: Ti-EE26030726-901 Tel: +86-755-66850100 E-mail: [email protected] Page No. 4 / 14 Web: www.titcgroup.com Template No.: TRP-Passive-EN (2022-09-07) Add: Block B, 1/F, Baisha Science and Technology Park, Shahe Xi Road, Nanshan District, Shenzhen, Guangdong Province, P. R. China 2 PRODUCT INFORMATION 2.1 Applicant Information Applicant Wavy Industries AS, org nr. 935955335 Address Suttestadvegen 6, 2613 Lillehammer Norway 2.2 Manufacturer Information Manufacturer N/A Address N/A 2.3 General Description for Equipment under Test (EUT) EUT Name MONKEY Model Name Under Test WIMKYOO1 Antenna Type PCB Antenna Dimensions 15mm * 1mm 2.4 Ancillary Equipment Note: Not applicable. Report No.: Ti-EE26030726-901 Tel: …
Text truncated - open the document above for the full version.
Report No.: Ti -EE26030726-AA 1 / 1 EUT PHOTO --BLANK BELOW-- Antenna
Report No.: Ti-EE26030726-AO 1 / 1 TEST SETUP PHOTOS --BLANK BELOW--
EFGX26010012-IE-01-Setup Photos 1 / 1
3722 Illinois Avenue · Saint Charles, 60174 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 480.00 µW |