Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
HALEMEIER GmbH * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID:2BUDKHA-ZSM-MW2 FRN of applicant:0037860731 Per section 2.911(d)(7) of the FCC rules,HALEMEIER GmbH certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: GLOCERTS TECHNOLOGY INC FCC Registration Number (FRN):0036339737 Physical U.S. Company Address:19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507 Contact Person:Huiying Fan Agent Email Address:[email protected] Telephone No: (626) 588-8039 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name:SvenLubahn Title:head of R&D Company Name: HALEMEIER GmbH Date: 4/28/2026 Agent Signed: Signed: Printed name:Huiying Fan Title:Director Company Name: GLOCERTS TECHNOLOGY INC Date: 4/28/2026
HALEMEIER GmbH Section 2.911(d)(5)(i) Certification – EquipmentType Company name:HALEMEIER GmbH Address: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Product Name:Smart sender FCC ID: 2BUDKHA-ZSM-MW2 Model(s): HA-ZSM-MW², SR-ZG9001K17-CCT, 31.122.01, 31.122.02, 31.122.03, 31.122.04, 3112201, 3112202, 3112203, 3112204 2.911(d)(5)(i) EquipmentType We, [HALEMEIER GmbH] certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Signature: Name:Sven Lubahn Date: 2026-3-11 Title and Company name: head of R&D and HALEMEIER GmbH NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
HALEMEIER GmbH Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name:HALEMEIER GmbH Address: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Product Name:Smart sender FCC ID: 2BUDKHA-ZSM-MW2 Model(s): HA-ZSM-MW², SR-ZG9001K17-CCT, 31.122.01, 31.122.02, 31.122.03, 31.122.04, 3112201, 3112202, 3112203, 3112204 2.911(d)(5)(ii) Applicant filing We, [HALEMEIER GmbH] certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Signature: Name:Sven Lubahn Date: 2026-3-11 Title and Company name: head of R&Dand HALEMEIER GmbH NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
DifferencesDeclaration Towhomconcern, WecompanyHALEMEIERGmbHherebydeclares: TheproductmodelsSR-ZG9001K17-CCT,HA-ZSM-MW ² ,31.122.01, 31.122.02,31.122.03,31.122.04,3112201,3112202,3112203,3112204are identicalinthesamePCBlayout,interiorstructureandelectricalcircuits,the onlydifferenceisthemodelnameforcommercialpurpose. Authorizedsignature: Date:2026-4-8
Agent Authorization Company name:HALEMEIER GmbH Address: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Product Name:Smart sender Model(s): HA-ZSM-MW², SR-ZG9001K17-CCT, 31.122.01, 31.122.02, 31.122.03, 31.122.04, 3112201, 3112202, 3112203, 3112204 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2026-3-11 Name: Sven Lubahn Title: head of R&D Company: HALEMEIER GmbH
Responsibility Declaration Letter v1.0 Responsibility Declaration Letter Company name:HALEMEIER GmbH Address: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Product Name:Smart sender FCC ID: 2BUDKHA-ZSM-MW2 Model(s):SR-ZG9001K17-CCT, HA-ZSM-MW², 31.122.01, 31.122.02, 31.122.03, 31.122.04, 3112201, 3112202, 3112203, 3112204 We, [HALEMEIER GmbH], hereby acknowledge that all the product information (including all original, drafted, or modified documents) provided to the TCB either by us or our agent or representative(s)for the purposes of FCC certification will meet FCC regulations and requirements; and that any modifications or changes made as a result of TCB review of the documents will be formally implemented into the manufacturing process and product documentation shipped with equipment. We also confirm that all information provided is legitimate and does not contain any false content such as forgery, fabrication, alteration, tampering and concealment. We assume all economic and legal responsibilities in matters that may arise as a result of disclosure on sample products and associated product documentation provided for product certification that may subsequently be found to be a mis-representation of the final product and accompanying documentation when produced, marketed, or sold in the United States, Canada, or anywhere in the world. Your sincerely, Name:Sven Lubahn Date: 2026-3-11 Title and Company name: head of R&D and HALEMEIER GmbH Signature of FCC grant holder (Include Title, Company name, date, and official company stamp):
<HALEMEIERGmbH> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2026-3-11 Subject;RequestforLongTermConfidentiality FCCID:2BUDKHA-ZSM-MW2 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription PursuanttoPublicNoticeDA04-1705oftheCommission'spolicy,inordertocomplywiththe marketingregulationsin47CFT§2.803andtheimportationrulesin47CFR§2.1204,while ensuringthatbusinesssensitiveinformationremainsconfidentialuntiltheactualmarketingof newlyauthorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:SvenLubahn Title:headofR&D
FCC ID:2BUDKHA-ZSM-MW2 RF Exposure evaluation According to 447498 D04 Interim General RF Exposure Guidance v01 ERP/EIRP = P T +G T −L C ERP/EIRP is the equivalent (or effective) radiated power [in same units as P T , typically dBW, dBm, or power spectral density (psd)], relative to either a dipole antenna (ERP) or an isotropic antenna (EIRP). P T is the transmitter output power, in dBW, dBm, or psd (power over a specified reference bandwidth). G T is the gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP). L C is the signal attenuation in the connecting cable between the transmitter and the antenna, in dB. For ZigBee mode Frequenc y (MHz) Output power (dBm) Ant gain (dBi) EIRP (dBm) EIRP (mw) ERP(dBm) ERP(mw) Distanc e (cm) P th (mW) 2405 2.95 1.23 4.18 2.62 2.03 1.60 0.5 2.78 ERP = EIRP −2.15 dB WORSE CASE 2.62mW<2.78mW Then SAR evaluation is not required
Page 1 of 10 Testing Report Manufacture Name: Shenzhen Sunricher Technology Limited Product Name: Wireless Remote Sample Model: SR-ZG9001K17-CCT Reference Standard: GB/T 9410-2008; ANSI/IEEE Std149-1979 Issue Date: 2025.9.23 Engineer:Date: Auditor:Date: Approver:Date: 2025.9.23 2025.9.23 2025.9.23 Page 2 of 10 Version Version No.DateDescriptionFormulateApproval A02025.9.23For the first time, formulateZkrisEason Page 3 of 10 1.General Information Testing principle Page 4 of 10 Test equipment EquipmentModel No.Serial No.Manufacturer Calibration date Next calibration date OTA Test System RayZone-5000 RFI-LAB-RF -D00 GTS2025.3.142027.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2025.5.112026.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2025.5.112026.5.10 Test environment Temperature 24.2°C Humidity 58%RH Pressure 100.21kPa Page 5 of 10 2.Sample Information Client information Name Shenzhen Sunricher Technology Limited Address / Contacts / Tel / E-mail / Manufacturer Shenzhen Sunricher Technology Limited Description of EUT(S) Product Name Wireless Remote Sample Model SR-ZG9001K17-CCT Serial No. Antenna Size / Antenna Type PCB Antenna Test Item VSWR;Antenna gain; Efficiency; Radiation pattern Frequency Range 2400-2500MHz Received Date 2025.9.22 Test Date 2025.9.23 Remark / / Page 6 of 10 EUT appearance EUT setup photo of free space OTA testing Planform Front view Page 7 of 10 3.Test Results Test standard NameParameterMethodStandard no. Mobile communication antenna Antenna gain Generic specification for antennas used in the mobile communications GB/T 9410-2008 Radiation pattern VSWR Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 Gain and directivity Test uncertainty The uncertainty was calculated on t he basis of the GUM published by I SO, using t he inclusion factor of K=2 and the 95% confidence level to express the extended uncertainty. ItemUncertainty VSWR±0.3 Antenna gain±0.72dB Radiation efficiency±0.72dB Page 8 of 10 3.3 Test data VSWR parameters VSWR data Typical free space efficiency and gain Frequency/MHz 240024502500 VSWR 1.90342.15153.1852 Frequency/MHz 24002410242024302440245024602470248024902500 Peak Gain/dBi 1.230.910.630.570.580.560.440.250.15-0.01-0.06 Efficiency/% 18.6517.8316.7216.2515.8315.2014.3413.7413.4812.8112.35 Page 9 of 10 Typical free space radiation pattern (1) X-Z Plane (unit:dBi): (2) Y-Z Plane (unit:dBi): Page 10 of 10 (3) X-Y Plane (unit:dBi): (4)TypicalFree Space3D RadiationPatternat 2.4GHz (unit:dBi): -------------------------------------------------End------------------------------------------------ (Thefollowingis blank)
ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 1 of 12 1.DutyCycle 1.1TestResult 1.1.1Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) DutyCycle (%) DutyCycle CorrectionFactor(dB) Max.DC Variation(%) O-QPSKSISO 24051.2451.49383.390.790.03 24451.2451.49283.450.790.03 24800.5720.82169.671.570.04 1.2TestGraph 1.2.1Ant1 O-QPSK_LCH_2405MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 2 of 12 O-QPSK_MCH_2445MHz_Ant1_NTNV O-QPSK_HCH_2480MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 3 of 12 2.Bandwidth 2.1TestResult 2.1.1OBW Mode TX Type Frequency (MHz) ANT 99%OccupiedBandwidth(MHz) Verdict ResultLimit O-QPSKSISO 240512.215/Pass 244512.218/Pass 248012.225/Pass 2.1.26dBBW Mode TX Type Frequency (MHz) ANT 6dBBandwidth(MHz) Verdict ResultLimit O-QPSKSISO 240511.147>=0.5Pass 244511.146>=0.5Pass 248011.096>=0.5Pass 2.2TestGraph 2.2.1OBW O-QPSK_LCH_2405MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 4 of 12 O-QPSK_MCH_2445MHz_Ant1_NTNV O-QPSK_HCH_2480MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 5 of 12 2.2.26dBBW O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 6 of 12 O-QPSK_HCH_2480MHz_Ant1_NTNV 3.MaximumConductedOutputPower 3.1TestResult 3.1.1Power Mode TX Type Frequency (MHz) MaximumPeakConductedOutputPower(dBm) Verdict ANT1Limit O-QPSKSISO 24052.95<=30Pass 24452.81<=30Pass 24802.70<=30Pass Note1:AntennaGain:Ant1:1.23dBi; 4.MaximumPowerSpectralDensity 4.1TestResult 4.1.1PSD Mode TX Type Frequency (MHz) MaximumPSD(dBm) Verdict ANT1Limit O-QPSKSISO 24052.74<=8Pass 24452.61<=8Pass 24802.50<=8Pass Note1:AntennaGain:Ant1:1.23dBi; ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 7 of 12 4.2TestGraph 4.2.1PSD O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 8 of 12 O-QPSK_HCH_2480MHz_Ant1_NTNV 5.UnwantedEmissionsInNon-restrictedFrequencyBands 5.1TestResult 5.1.1Ref Mode TX Type Frequency (MHz) ANT LevelofReference (dBm) O-QPSKSISO 240512.75 244512.60 248012.50 Note1:RefertoFCCPart15.247(d)andANSIC63.10-2013,thechannelcontainsthemaximumPSDlevelwasusedtoestablishthe referencelevel. 5.1.2CSE Mode TX Type Frequency (MHz) ANT LevelofReference (dBm) Limit (dBm) Verdict O-QPSKSISO 240512.75-17.25Pass 244512.60-17.40Pass 248012.50-17.50Pass Note1:RefertoFCCPart15.247(d)andANSIC63.10-2013,thechannelcontainsthemaximumPSDlevelwasusedtoestablishthe referencelevel. ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 9 of 12 5.2TestGraph 5.2.1Ref O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 10 of 12 O-QPSK_HCH_2480MHz_Ant1_NTNV 5.2.2CSE O-QPSK_LCH_2405MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 11 of 12 O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 12 of 12 O-QPSK_HCH_2480MHz_Ant1_NTNV O-QPSK_HCH_2480MHz_Ant1_NTNV ------End------
GlobalUnitedTechnologyServicesCo.,Ltd. ReportNo.:GTS2025100227F01 AuthorizedSignature: RobinsonLuo LaboratoryManager Thisresultsshowninthistestreportreferonlytothesample(s)tested,thistestreportcannotbereproduced,exceptin full,withoutpriorwrittenpermissionofthecompany.Thereportwouldbeinvalidwithoutspecificstampoftestinstitute andthesignaturesofcompilerandapprover. Page1of30 TESTREPORT Applicant:HALEMEIERGmbH AddressofApplicant:LangeStrasse5149326Melle,Neuenkirchen,Germany Manufacturer:HALEMEIERGmbH Addressof Manufacturer: LangeStrasse5149326Melle,Neuenkirchen,Germany EquipmentUnderTest(EUT) ProductName:Smartsender ModelNo.: HA-ZSM-MW²,SR-ZG9001K17-CCT,31.122.01,31.122.02, 31.122.03,31.122.04,3112201,3112202,3112203,3112204 FCCID:2BUDKHA-ZSM-MW2 Applicablestandards:FCCCFRTitle47Part15SubpartCSection15.247 Dateofsamplereceipt:October17,2025 DateofTest:October17,2025-November04,2025 Dateofreportissued:April30,2026 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 2 of 30 2Version VersionNo.DateDescription 00April30,2026Original TestedBy:Date:April30,2026 TestEngineer PreparedBy:Date:April30,2026 ProjectEngineer CheckBy:Date:April30,2026 Reviewer ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 3 of 30 3Contents Page 1COVERPAGE .......................................................................................................................................................... 1 2VERSION.........................................................................................................................................................2 3CONTENTS.....................................................................................................................................................3 4TESTSUMMARY............................................................................................................................................4 5GENERALINFORMATION.............................................................................................................................5 5.1GENERALDESCRIPTIONOFEUT................................................................................................................5 5.2TESTMODE................................................................................................................................................7 5.3DESCRIPTIONOFSUPPORTUNITS...............................................................................................................7 5.4DEVIATIONFROMSTANDARDS....................................................................................................................7 5.5ABNORMALITIESFROMSTANDARDCONDITIONS..........................................................................................7 5.6TESTFACILITY...........................................................................................................................................7 5.7TESTLOCATION.........................................................................................................................................7 5.8ADDITIONALINSTRUCTIONS........................................................................................................................7 6TESTINSTRUMENTSLIST............................................................................................................................8 7TESTRESULTSANDMEASUREMENTDATA..........................................................................................10 7.1ANTENNAREQUIREMENT...........................................................................................................................10 7.2CONDUCTEDOUTPUTPOWER...................................................................................................................11 7.3CHANNELBANDWIDTH..............................................................................................................................12 7.4POWERSPECTRALDENSITY.....................................................................................................................13 7.5SPURIOUSEMISSIONINNON-RESTRICTED&RESTRICTEDBANDS..............................................................14 7.5.1ConductedEmissionMethod..........................................................................................................14 7.5.2RadiatedEmissionMethod.............................................................................................................15 8TESTSETUPPHOTO...................................................................................................................................30 9EUTCONSTRUCTIONALDETAILS............................................................................................................30 ReportNo.:GTS2025100227F01 GlobalUnitedTechnologyServicesCo.,Ltd. No.123-128,TowerA,JinyuanBusinessBuilding,No.2,LaodongIndustrialZone, XixiangRoad,BaoanDistrict,Shenzhen,Guangdong,China518102 Telephone:+86(0)75527798480Fax:+86(0)75527798960Page 4 of 30 4TestSummary TestItemSectioninCFR47Result Antennarequirement15.203/15.247(c)Pass ACPowerLineConductedEmission15.207N/A ConductedOutputPower15.247(b)(3)Pass ChannelBandwidth15.247(a)(2)Pass PowerSpectralDensity15.247(e)Pass BandEdge15.247(d)Pass SpuriousEmission15.205/15.209Pass Remarks: 1.Pass:TheEUTcomplieswiththeessentialrequirementsinthestandard. 2.TestaccordingtoANSIC63.10:2020 MeasurementUncertainty No.ItemMeasurementUncertainty 1RadioFrequency±7.25×10 -8 2Dutycycle±0.37% 3OccupiedBandwidth±3% 4RFconductedpower±0.75dB 5RFpowerdensity±3dB…
Text truncated - open the document above for the full version.
19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507 · RIVERSIDE, California, 92507 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.97 mW |