FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. HALEMEIER GmbH/
  3. 2BUDKHAL-MW12-M

2BUDKHAL-MW12-MLED Controller

HALEMEIER GmbH

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 12, 2026
Application Purpose
Original Equipment
Equipment Note
LED Controller
Frequency Range
2402.00000000 - 2480.00000000
Company
HALEMEIER GmbH
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

HALEMEIER GmbH Section 2.911(d)(5)(i) Certification – EquipmentType Company name: HALEMEIER GmbH Address: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Product Name: LED Controller FCC ID: 2BUDKHAL-MW12-M Model(s): HAL-MW12-M,HAL-MW24-M 2.911(d)(5)(i) EquipmentType We, [HALEMEIER GmbH] certify that the equipment for which authorization is sought through certification is not:  Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules.  Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Signature: Name: Sven Lubahn Date: 2026-01-13 Title and Company name: head of R&D and HALEMEIER GmbH NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

HALEMEIER GmbH Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: HALEMEIER GmbH Address: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Product Name: LED Controller FCC ID: 2BUDKHAL-MW12-M Model(s): HAL-MW12-M,HAL-MW24-M 2.911(d)(5)(ii) Applicant filing We, [HALEMEIER GmbH] certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely, Signature: Name: Sven Lubahn Date: 2026-01-13 Title and Company name: head of R&D and HALEMEIER GmbH NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Cover Letter(s)

HALEMEIER GmbH Agent Authorization Company: HALEMEIER GmbH Address: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Product Name: LED Controller Model Number(s): HAL-MW12-M,HAL-MW24-M We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2026-01-13 Name: Sven Lubahn Title: head of R&D Company: HALEMEIER GmbH

Cover Letter(s)

HALEMEIER GmbH Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-01-13 Subject; Request for Confidentiality FCC ID: 2BUDKHAL-MW12-M To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Sven Lubahn Title: head of R&D

ID Label/Location Info

R-R-GmbH-HAL-MW12-M 210-265802 FCC ID: 2BUDKHAL-MW12-M EXXXXXX SUITABLE FOR DAMP LOCATIONS. CONVIENT AUX EMPLACEMENTS HUMIDES. Class 2 85W SEC:48V 1.78A Max.85W R G R G R-R-GmbH-HAL-MW12-M XXX-XXXXXX FCC ID: 2BUDKHAL-MW12-M EXXXXXX Output/SEC: Total Max.60W SUITABLE FOR DAMP LOCATIONS. CONVIENT AUX EMPLACEMENTS HUMIDES. Class 2 SEC:48V 1.25A Max.60W R G R G

RF Exposure Info

FCC ID: 2BUDKHAL-MW12-M RF Exposure Evaluation Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. Test Result of RF Exposure Evaluation Band Frequency Max output power (dBm) Output power (mW) Antenna gain (dBi) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Verdict Zigbee 2405MHz 6.29 4.26 1.23 0.0011 1.0 PASS The max power density is less than MPE exempt limit, so it is compliance.

Test Report

Page 1 of 10 Testing Report Manufacture Name: Shenzhen Sunricher Technology Limited Product Name: LED Controller Sample Model: HAL-MW12-M, HAL-MW24-M Reference Standard: GB/T 9410-2008; ANSI/IEEE Std149-1979 Issue Date: 2025.9.24 Engineer:Date: Auditor:Date: Approver:Date: 2025.9.24 2025.9.24 2025.9.24 Page 2 of 10 Version Version No.DateDescriptionFormulateApproval A02025.9.24For the first time, formulateZkrisEason Page 3 of 10 1.General Information Testing principle Page 4 of 10 Test equipment EquipmentModel No.Serial No.Manufacturer Calibration date Next calibration date OTA Test System RayZone-5000 RFI-LAB-RF -D00 GTS2025.3.142027.3.13 Network Analyzer E5071C RFI-LAB-RF -D01 KEYSIGHT2025.5.112026.5.10 Network Analyzer E5071C RFI-LAB-RF -C02 KEYSIGHT2025.5.112026.5.10 Test environment Temperature 24.3°C Humidity 58%RH Pressure 100.21kPa Page 5 of 10 2.Sample Information Client information Name Shenzhen Sunricher Technology Limited Address / Contacts / Tel / E-mail / Manufacturer Shenzhen Sunricher Technology Limited Description of EUT(S) Product Name LED Controller Sample Model HAL-MW12-M, HAL-MW24-M Serial No. Antenna Size / Antenna Type PCB Antenna Test Item VSWR;Antenna gain; Efficiency; Radiation pattern Frequency Range 2400-2500MHz Received Date 2025.9.22 Test Date 2025.9.23 Remark / / Page 6 of 10 EUT appearance EUT setup photo of free space OTA testing Planform Front view Page 7 of 10 3.Test Results Test standard NameParameterMethodStandard no. Mobile communication antenna Antenna gain Generic specification for antennas used in the mobile communications GB/T 9410-2008 Radiation pattern VSWR Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 Gain and directivity Test uncertainty The uncertainty was calculated on t he basis of the GUM published by I SO, using t he inclusion factor of K=2 and the 95% confidence level to express the extended uncertainty. ItemUncertainty VSWR±0.3 Antenna gain±0.72dB Radiation efficiency±0.72dB Page 8 of 10 3.3 Test data VSWR parameters VSWR data Typical free space efficiency and gain Frequency/MHz 240024502500 VSWR 1.90342.15153.1852 Frequency/MHz 24002410242024302440245024602470248024902500 Peak Gain/dBi 1.230.910.630.570.580.560.440.250.15-0.01-0.06 Efficiency/% 18.6517.8316.7216.2515.8315.2014.3413.7413.4812.8112.35 Page 9 of 10 Typical free space radiation pattern (1) X-Z Plane (unit:dBi): (2) Y-Z Plane (unit:dBi): Page 10 of 10 (3) X-Y Plane (unit:dBi): (4)TypicalFree Space3D RadiationPatternat 2.4GHz (unit:dBi): -------------------------------------------------End------------------------------------------------ (Thefollowingis blank)

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS2025110376F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 47 TEST REPORT Applicant: HALEMEIER GmbH Address of Applicant: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Manufacturer: HALEMEIER GmbH Address of Manufacturer: Lange Strasse 51 49326 Melle, Neuenkirchen, Germany Equipment Under Test (EUT) Product Name: LED Controller Model No.: HAL-MW12-M,HAL-MW24-M FCC ID: 2BUDKHAL-MW12-M Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: November 21, 2025 Date of Test: November 22, 2025-December 23, 2025 Date of report issued: April 30, 2026 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 47 2 Version Version No. Date Description 00 April 30, 2026 Original Tested By: Date: April 30, 2026 Test Engineer Prepared By: Date: April 30, 2026 Project Engineer Check By: Date: April 30, 2026 Reviewer Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 47 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED EMISSIONS ................................................................................................................... 11 7.3 CONDUCTED OUTPUT POWER ........................................................................................................... 16 7.4 CHANNEL BANDWIDTH ...................................................................................................................... 17 7.5 POWER SPECTRAL DENSITY ............................................................................................................. 18 7.6 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 19 7.6.1 Conducted Emission Method ..................................................................................................... 19 7.6.2 Radiated Emission Method ........................................................................................................ 20 8 TEST SETUP PHOTO ............................................................................................................................ 47 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 47 Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 47 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203/15.247 (c) Pass AC Power Line Conducted Emission 15.207 Pass Conducted Output Power 15.247 (b)(3) Pass Channel Bandwidth 15.247 (a)(2) Pass Power Spectral Density 15.247 (e) Pass Band Edge 15.247(d…

Text truncated - open the document above for the full version.

Test Report

Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 13 1. Bandwidth 1.1 Test Result 1.1.1 OBW Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit O-QPSK SISO 2405 1 2.307 / Pass 2445 1 2.301 / Pass 2480 1 2.316 / Pass 1.1.2 6dB BW Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit O-QPSK SISO 2405 1 1.401 >=0.5 Pass 2445 1 1.396 >=0.5 Pass 2480 1 1.451 >=0.5 Pass Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 13 1.2 Test Graph 1.2.1 OBW O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 13 O-QPSK_HCH_2480MHz_Ant1_NTNV 1.2.2 6dB BW O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 13 O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 13 2. Maximum Conducted Output Power 2.1 Test Result 2.1.1 Power Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit O-QPSK SISO 2405 6.29 <=30 Pass 2445 5.99 <=30 Pass 2480 5.62 <=30 Pass Note1: Antenna Gain: Ant1: 1.23dBi; 3. Maximum Power Spectral Density 3.1 Test Result 3.1.1 PSD Mode TX Type Frequency (MHz) Maximum PSD (dBm) Verdict ANT1 Limit O-QPSK SISO 2405 4.54 <=8 Pass 2445 4.25 <=8 Pass 2480 3.90 <=8 Pass Note1: Antenna Gain: Ant1: 1.23dBi; Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 13 3.2 Test Graph 3.2.1 PSD O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 13 O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 13 4. Unwanted Emissions In Non-restricted Frequency Bands 4.1 Test Result 4.1.1 Ref Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) O-QPSK SISO 2405 1 4.55 2445 1 4.25 2480 1 3.90 Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. 4.1.2 CSE Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) Limit (dBm) Verdict O-QPSK SISO 2405 1 4.55 -15.45 Pass 2445 1 4.25 -15.75 Pass 2480 1 3.90 -16.10 Pass Note1: Refer to FCC Part 15.247 (d) and ANSI C63.10-2013, the channel contains the maximum PSD level was used to establish the reference level. Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 13 4.2 Test Graph 4.2.1 Ref O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_MCH_2445MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 13 O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 13 4.2.2 CSE O-QPSK_LCH_2405MHz_Ant1_NTNV O-QPSK_LCH_2405MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 13 O-QPSK_MCH_2445MHz_Ant1_NTNV O-QPSK_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025110376F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 13 O-QPSK_HCH_2480MHz_Ant1_NTNV ------End------

Contact Information

Applicant

Sven Lubahn(head of R&D)
[email protected]Fax: +49-(0)5428/50380-16

Technical Contact

GLOCERTS TECHNOLOGY INCHuiying Fan
[email protected]

19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507 · RIVERSIDE, California, 92507 · United States

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.26 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.