Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 08, 2026
Application Purpose
Original Equipment
Equipment Note
ETOE Starfish 2 Projector
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Etoe Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Starfish 2 User Manual Hey Google Safety Instructions Read all instructions before you use this device. Do not make any changes that are not described in this manual. If physical injury, loss of data, or damage is caused by failure to follow instructions, the warranty does not apply. Setup • To reduce the risk of fire and/or electric shock, do not expose the device to rain or moisture, and objects filled with liquids, such as vases, should not be placed on the device. • Do not place the device in areas susceptible to excessive dust and dirt or near any appliance generating a strong magnetic field. • To prevent overheating, do not block or clog the ventilation openings. Never place the device in a confined space. Always leave enough space around the device for ventilation. • Protect the device against direct sunlight, heat, large temperature fluctuations and moisture. • When the device runs for a long period of time and the surface becomes hot, shut it down and unplug the power cord. Resume operation only after the device has cooled. • Always handle the device with care. Avoid touching the lens. • Never place heavy or sharp objects on the device or the power cord. To avoid electric shock, do not disassemble. • Only use attachments or accessories specified by the manufacturer. Avoid extreme vibration. It may damage the internal components. Do not allow children to handle the device without supervision. • Under the following conditions, a layer of moisture can appear inside the device which can lead to malfunctions: To avoid any moisture, seal the device in a plastic bag before moving it to another room, and wait for one to two hours before you take it out of the bag. • Do not place the device on soft surfaces such as tablecloths or carpets as doing so could be a fire-hazard. a) if the device is moved from a cold to a warm area; b) after a cold room is heated; c) when the device is placed in a damp room. EN 01 EN 01 Power Supply • Use only the provided power adapter. • Power off the device before removing the power supply from the socket. • Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from this device. • Unplug this device if there are lightning storms or when unused for a long period of time. • Where the power plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable. • Before you make or change any connections, ensure that all devices are disconnected from the power outlet. • Do not touch the power cable or the power connector with wet hands. Hearing Safety • To avoid hearing damage, do not listen for extended periods at high volume. Set the volume at a safe level. Cleaning • Power off the device and remove it from the power supply before cleaning the surface. • Use a soft, lint-free cloth. Never use liquid, gaseous, or easily flammable cleansers (like sprays, abrasives, polishes, and alcohol). Wipe over the surfaces gently. Be careful that you do not scratch the surfaces. • Do not use any liquid cleaning agents to clean the lens as they may damage the protective coating on the lens. Use lens cleaning paper to clean the lens of the projector. Repairs • Do not make any repairs to the device by yourself. Only have your device repaired by an authorized service center. • Improper maintenance can result in injuries or damage to the device. • Refer all servicing to qualified service personnel. Caution • Do not stare at operating beam, the bright light may hurt your eyes. EN 02 What’s Included ProjectorRemote control Power AdapterUser manual ENENEN 03 EN User manual Note: The TV stick is already installed inside the product. EN 04 EN Autofocus Sensor Aux Port Lens USB Port HDMI Port Air ventilation(Outlet) ClockBluetooth speaker Alarm Clock Indicator: On: Alarm is set Off: Alarm is not set Ambient Light Button: Short press: Changes light color/style Long press: Switches between solid color and dynamic modes Projector Button Ambient Lighting Type C-inIR receiver • Do not look into the lens directly to avoid harm for your eyes. • Do not block the air ventilation(Outlet). • The alarm clock function only works when the power is on. • Keep the power on to ensure accurate time display. Attention: Overview 1 4 7 10 13 Status indicator light: Red: Standby Green: Projector is operating Blue: Bluetooth speaker is operating 16 2 5 8 11 14 Ambient light brightness: Press to switch brightness: Brightest -> Medium -> Darkest -> OFF 15 3 6 9 12 3 5 4 9 8 11 10 16 13 12 67 2 1 1 15 14 EN 05 Remote Control Note: • Install batteries before use.(Batteries not included). • Please pair the remote control for a better experience. • The distance between the remote and the projector should not exceed 10 m / 33 ft. • Press the button once: Power on • Press the button twice: Power off Activate Google Assistant Projector settings Press to confirm a selection or entry Navigate through menus or adjust selected content Return to the previous page Go to TV homepage Volume up/down Adjust the focus 1 2 3 4 5 6 7 8 9 10 11 Press to switch Ambient light brightness: Brightest -> Medium -> Darkest -> OFF Ambient Light Button: Short press: Changes light color/style Long press: Switches between solid color and dynamic modes Getting Started Placement Position the projector so that it is facing toward the projection surface to get a rectangular picture. The distance between the projector and the projection surface will determine the size of the picture. Check the projection distance and screen size in the Specifications section. Make sure there are no obstacles within 30 cm/11.8" blocking the vents. • The Projection distance should be between 1.5 m and 4.5 m. EN 06 100“ 80“ 60“ 1.62m 2.16m 2.70m 516275291335260 80 100 120 70 87 105 177 221 266 39 49 59 100 125 149 7 9 11 216 270 324 Screen size (inch) Width (inch) Width (cm) Height (cm) Distance (cm) Distance (ft) Height (inch) Ambient Lighti…

Text truncated - open the document above for the full version.

External Photos

FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of EUT FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Photo 3 Appearance of EUT Photo 4 Appearance of EUT FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Photo 5 Appearance of EUT Photo 6 Appearance of EUT FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Photo 7 Adapter Appearance

ID Label/Location Info

FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Appendix I Label Appendix II Label Location FCC ID:2BUEG-R2T Model:R2T

Internal Photos

FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Appendix IV EUT Internal Photographs Photo 8 Internal of EUT Photo 9 Internal of EUT FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Photo 10 Appearance of PCB Photo 11 Appearance of PCB FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Photo 12 Appearance of PCB Photo 13 Appearance of PCB BT Ant FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Photo 14 Appearance of PCB Photo 15 Appearance of PCB FCC ID:2BUEG-R2T www.cotecna-toby.com TB-RF-074-1.1 Photo 16 Appearance of PCB

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202512-0415-9 Page: 1 of 8 TB-RF-073-3.1 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Email: [email protected] www.cotecna-toby.com Maximum Permissible Exposure Evaluation FCC ID: 2BUEG-R2T Report No. : TBR-C-202512-0415-9 Applicant : Shenzhen Etoe Technology Co.,Ltd Equipment Under Test (EUT) EUT Name : ETOE Starfish 2 Projector Model No. : R2T Series Model No. : R2J, R2P, R2L, R2A Brand Name : ETOE Sample ID : HC-C-202512-0415-01-01 Receipt Date : 2026-01-29 Test Date : 2026-01-29 to 2026-03-30 Issue Date : 2026-03-30 Standards : FCC Part 2.1091 Test Method : KDB 447498 D01 General RF Exposure Guidance v06 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Test By : Gold zhang Reviewed By : Henry huang Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202512-0415-9 Page: 2 of 8 www.cotecna-toby.com TB-RF-073-3.1 CONTENTS CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 4 1.1 Client Information ................................................................................................................. 4 1.2 General Description of EUT (Equipment Under Test) ................................................... 4 2. MEASUREMENT UNCERTAINTY .......................................................................................... 5 3. TEST FACILITY.......................................................................................................................... 6 4. METHOD OF MEASUREMENT FOR FCC............................................................................ 7 5. TEST RESULT............................................................................................................................ 8 Report No.: TBR-C-202512-0415-9 Page: 3 of 8 www.cotecna-toby.com TB-RF-073-3.1 Revision History Report No. Version Description Issued Date TBR-C-202512-0415-9 Rev.01 Initial issue of report 2026-03-30 Report No.: TBR-C-202512-0415-9 Page: 4 of 8 www.cotecna-toby.com TB-RF-073-3.1 1. General Information about EUT 1.1 Client Information Applicant : Shenzhen Etoe Technology Co.,Ltd Address : 201,No.36,Hezhou Road, Hangcheng Street, Baoan District, Shenzhen, Guangdong, China Manufacturer : Shenzhen Etoe Technology Co.,Ltd Address : 201,No.36,Hezhou Road, Hangcheng Street, Baoan District, Shenzhen, Guangdong, China 1.2 General Description of EUT (Equipment Under Test) EUT Name : ETOE Starfish 2 Projector Models No. : R2T, R2J, R2P, R2L, R2A Model Different : All these models are identical in the same PCB, layout and electrical circuit, the only difference is model name for commercial. Product Description : Operation Frequency: Bluetooth: 2402MHz~2480MHz Modulation Type: Bluetooth: GFSK, Pi/4-DQPSK, 8DPSK Antenna Gain: -0.58dBi PCB Antenna Power Rating : Adapter: (Model:P1014UN) Input: 100-240V~50/60Hz 2.0A Output: 5.0V/9.0V/12.0V/15.0V⎓3.0A 20.0V⎓5.0A 100W Max Software Version : V1.0.0.7 Hardware Version : 3H078 Remark: The above antenna information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications, the laboratory shall not be held responsible. Report No.: TBR-C-202512-0415-9 Page: 5 of 8 www.cotecna-toby.com TB-RF-073-3.1 2. Measurement Uncertainty The reported uncertainty of measurement y±U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. Test Item Parameters Expanded Uncertainty (ULab) Conducted Emission Level Accuracy: 9kHz~150kHz 150kHz to 30MHz ±3.50 dB ±3.10 dB Radiated Emission Level Accuracy: 9kHz to 30 MHz ±4.60 dB Radiated Emission Level Accuracy: 30MHz to 1000 MHz ±4.50 dB Radiated Emission Level Accuracy: Above 1000MHz ±4.20 dB Temperature / ±0.6°C Humidity / ±4% Supply voltages / ±2% Time / ±4% Report No.: TBR-C-202512-0415-9 Page: 6 of 8 www.cotecna-toby.com TB-RF-073-3.1 3. Test Facility The testing report were performed by the Shenzhen Toby Technology Co., Ltd., in their facilities located at 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. At the time of testing, the following bodies accredited the Laboratory: CNAS (L5813) The Laboratory has been accredited by CNAS to ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories for the competence in the field of testing. And the Registration No.: CNAS L5813. A2LA Certificate No.: 4750.01 The laboratory has been accredited by American Association for Laboratory Accreditation(A2LA) to ISO/IEC 17025:2017 General Requirements for the Competence of Testing and Calibration Laboratories for the technical competence in the field of Electrical Testing. And the A2LA Certificate No.: 4750.01.FCC Accredited Test Site Number: 854351. Designation Number: CN1223. IC Registration No.: (11950A) The Laboratory has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing. The site registration: Site# 11950A. CAB identifier: CN0056. Report No.: TBR-C-202512-0415-9 Page: 7 of 8 www.cotecna-toby.com TB-RF-073-3.1 4. Method of Measurement for FCC 4.1 EUT Operation Condition: Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 4.2 Exposure Evaluation: Equatio…

Text truncated - open the document above for the full version.

Test Report

ANTENNASPECIFICATION Summary ITEMANTSPEC ModelName2.4GANT Center Frequency HorizontalVertical 2400MHz2450MHz2500MHz2400MHz2450MHz2500MHz -1.73-0.84-0.58-6.15-3.7-2.32 MAX.Gain-0.58dBi PolarizationHorizontalandVertical AzimuthBeam Pattern Omni-directional Impedance50Ohm AntennaLength41.1mm Manufacture ADDRESS AntennaPhoto&Length(mm) Horizontal:2400MHz2450MHz2500MHz Max:0Min:-40Scale:5/div FrequencyGain(dB) (MHz)MaxMinAvg 2400-1.73178-30.0815-8.48713 2450-0.845801-38.5605-7.88012 2500-0.585586-24.0318-6.79139 Vertical:2400MHz2450MHz2500MHz Max:0Min:-30Scale:5/div FrequencyGain(dB) (MHz)MaxMinAvg 2400-6.153-24.142-13.0295 2450-3.7054-26.5836-10.67 2500-2.32122-30.4301-9.70536

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 1 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 RF Test Data for Bluetooth (BR+EDR) (Conducted Measurements) General Description of EUT EUT Name: ETOE Starfish 2 Projector Model: R2T Sample ID: HC-C-202512-0415-01-01 Test Standard: FCC Part 15.247 Environmental Conditions Ambient Temperature: 25.2°C Ambient Humidity: 45.8%RH Test Power Supply: DC 20V Test Engineer: Lily zhang Note: For a more detailed features description, please refer to the report TBR-C-202512-0415-6 Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 2 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 Contents 1: 20dB Emission Bandwidth ............................................................................................................................. 3 1.1 Test Result ......................................................................................................................................... 3 1.2 Test Graphs ....................................................................................................................................... 4 2: Occupied Channel Bandwidth ....................................................................................................................... 6 2.1 Test Result ......................................................................................................................................... 6 2.2 Test Graphs ....................................................................................................................................... 7 3: Maximum conducted output power .............................................................................................................. 9 3.1 Test Result Peak ............................................................................................................................... 9 3.2 Test Graphs ..................................................................................................................................... 10 4: Carrier frequency separation ....................................................................................................................... 12 4.1 Test Result ....................................................................................................................................... 12 4.2 Test Graphs ..................................................................................................................................... 13 5: Time of occupancy ....................................................................................................................................... 14 5.1 Test Result ....................................................................................................................................... 14 5.2 Test Graphs ..................................................................................................................................... 15 6: Number of hopping channels ...................................................................................................................... 18 6.1 Test Result ....................................................................................................................................... 18 6.2 Test Graphs ..................................................................................................................................... 19 7: Band edge measurements ........................................................................................................................... 20 7.1 Test Result ....................................................................................................................................... 20 7.2 Test Graphs ..................................................................................................................................... 21 8: Conducted Spurious Emission...................................................................................................................... 23 8.1 Test Result ....................................................................................................................................... 23 8.2 Test Graphs ..................................................................................................................................... 24 9: Duty Cycle .................................................................................................................................................... 29 9.1 Test Result ....................................................................................................................................... 29 9.2 Test Graphs ..................................................................................................................................... 30 10: Emissions in Restricted Bands .................................................................................................................... 32 10.1 Test Result ..................................................................................................................................... 32 10.2 Test Graphs ................................................................................................................................... 33 Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 3 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 1: 20dB Emission Bandwidth 1.1 Test Result Test Mode Antenna Frequency[MHz] 20dB EBW[MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict DH5 Ant1 2402 1.00 2401.49 2402.50 --- --- DH5 Ant1…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 30 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 9.2 Test Graphs NTNV-DH5-Ant1-2402 NTNV-DH5-Ant1-2441 NTNV-DH5-Ant1-2480 NTNV-2DH5-Ant1-2402 NTNV-2DH5-Ant1-2441 NTNV-2DH5-Ant1-2480 Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 31 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 NTNV-3DH5-Ant1-2402 NTNV-3DH5-Ant1-2441 NTNV-3DH5-Ant1-2480 Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 32 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 10: Emissions in Restricted Bands 10.1 Test Result Test Mode Antenna ChName Frequency [MHz] Detector Freq [MHz] Result [dBm] Limit [dBm] Result [dBuV/m] Limit [dBuV/m] Verdict DH5 Ant1 Low 2402 Peak 2390.000 -47.08 ≤-21.20 48.12 ≤74 PASS DH5 Ant1 Low 2402 Peak 2310.000 -56.86 ≤-21.20 38.34 ≤74 PASS DH5 Ant1 Low 2402 Peak 2381.413 -45.26 ≤-21.20 49.94 ≤74 PASS DH5 Ant1 Low 2402 AV 2390.000 -56.06 ≤-41.20 39.14 ≤54 PASS DH5 Ant1 Low 2402 AV 2310.000 -63.27 ≤-41.20 31.93 ≤54 PASS DH5 Ant1 Low 2402 AV 2379.739 -53.56 ≤-41.20 41.64 ≤54 PASS DH5 Ant1 High 2480 Peak 2483.500 -52.87 ≤-21.20 42.33 ≤74 PASS DH5 Ant1 High 2480 Peak 2500.000 -45.17 ≤-21.20 50.03 ≤74 PASS DH5 Ant1 High 2480 Peak 2497.594 -43.63 ≤-21.20 51.57 ≤74 PASS DH5 Ant1 High 2480 AV 2483.500 -57.92 ≤-41.20 37.28 ≤54 PASS DH5 Ant1 High 2480 AV 2500.000 -53.54 ≤-41.20 41.66 ≤54 PASS DH5 Ant1 High 2480 AV 2497.478 -52.47 ≤-41.20 42.73 ≤54 PASS 2DH5 Ant1 Low 2402 Peak 2390.000 -46.28 ≤-21.20 48.92 ≤74 PASS 2DH5 Ant1 Low 2402 Peak 2310.000 -53.92 ≤-21.20 41.28 ≤74 PASS 2DH5 Ant1 Low 2402 Peak 2386.283 -44.85 ≤-21.20 50.35 ≤74 PASS 2DH5 Ant1 Low 2402 AV 2390.000 -54.5 ≤-41.20 40.70 ≤54 PASS 2DH5 Ant1 Low 2402 AV 2310.000 -62.95 ≤-41.20 32.25 ≤54 PASS 2DH5 Ant1 Low 2402 AV 2383.391 -53.07 ≤-41.20 42.13 ≤54 PASS 2DH5 Ant1 High 2480 Peak 2483.500 -50.83 ≤-21.20 44.37 ≤74 PASS 2DH5 Ant1 High 2480 Peak 2500.000 -45.57 ≤-21.20 49.63 ≤74 PASS 2DH5 Ant1 High 2480 Peak 2495.623 -43.27 ≤-21.20 51.93 ≤74 PASS 2DH5 Ant1 High 2480 AV 2483.500 -57.12 ≤-41.20 38.08 ≤54 PASS 2DH5 Ant1 High 2480 AV 2500.000 -52.92 ≤-41.20 42.28 ≤54 PASS 2DH5 Ant1 High 2480 AV 2494.928 -52.44 ≤-41.20 42.76 ≤54 PASS 3DH5 Ant1 Low 2402 Peak 2390.000 -47.16 ≤-21.20 48.04 ≤74 PASS 3DH5 Ant1 Low 2402 Peak 2310.000 -53.08 ≤-21.20 42.12 ≤74 PASS 3DH5 Ant1 Low 2402 Peak 2379.739 -43.03 ≤-21.20 52.17 ≤74 PASS 3DH5 Ant1 Low 2402 AV 2390.000 -55.23 ≤-41.20 39.97 ≤54 PASS 3DH5 Ant1 Low 2402 AV 2310.000 -63.39 ≤-41.20 31.81 ≤54 PASS 3DH5 Ant1 Low 2402 AV 2381.109 -52.9 ≤-41.20 42.30 ≤54 PASS 3DH5 Ant1 High 2480 Peak 2483.500 -50.8 ≤-21.20 44.40 ≤74 PASS 3DH5 Ant1 High 2480 Peak 2500.000 -44.9 ≤-21.20 50.30 ≤74 PASS 3DH5 Ant1 High 2480 Peak 2498.522 -43.03 ≤-21.20 52.17 ≤74 PASS 3DH5 Ant1 High 2480 AV 2483.500 -58.06 ≤-41.20 37.14 ≤54 PASS 3DH5 Ant1 High 2480 AV 2500.000 -52.64 ≤-41.20 42.56 ≤54 PASS 3DH5 Ant1 High 2480 AV 2499.681 -52.54 ≤-41.20 42.66 ≤54 PASS Note: 1. The Antenna Gain is compensated in the graph. 2. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 33 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 10.2 Test Graphs DH5-Ant1-2402-PASS DH5-Ant1-2402-PASS DH5-Ant1-2480-PASS DH5-Ant1-2480-PASS 2DH5-Ant1-2402-PASS 2DH5-Ant1-2402-PASS Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202512-0415-6 Page: 34 of 34 FCC ID: 2BUEG-R2T TB-RF-073-3.1 2DH5-Ant1-2480-PASS 2DH5-Ant1-2480-PASS 3DH5-Ant1-2402-PASS 3DH5-Ant1-2402-PASS 3DH5-Ant1-2480-PASS 3DH5-Ant1-2480-PASS -----END OF THE REPORT-----

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202512-0415-6 Page: 1 of 39 TB-RF-073-3.1 1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Email: [email protected] www.cotecna-toby.com Radio Test Report FCC ID: 2BUEG-R2T Report No. : TBR-C-202512-0415-6 Applicant : Shenzhen Etoe Technology Co.,Ltd Equipment Under Test (EUT) EUT Name : ETOE Starfish 2 Projector Model No. : R2T Series Model No. : R2J, R2P, R2L, R2A Brand Name : ETOE Sample ID : HC-C-202512-0415-01-01&HC-C-202512-0415-02-01 Receipt Date : 2026-01-29 Test Date : 2026-01-29 to 2026-03-30 Issue Date : 2026-03-30 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2020 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Test By : Gold zhang Reviewed By : Henry huang Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202512-0415-6 Page: 2 of 39 www.cotecna-toby.com TB-RF-073-3.1 Contents CONTENTS ............................................................................................................................................ 2 1. GENERAL INFORMATION ABOUT EUT ............................................................................. 5 1.1 Client Information ................................................................................................................ 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 7 1.4 Description of Support Units .............................................................................................. 7 1.5 Description of Test Mode ................................................................................................... 8 1.6 Description of Test Software Setting ................................................................................ 9 1.7 Measurement Uncertainty ................................................................................................ 10 1.8 Test Facility......................................................................................................................... 11 2. TEST SUMMARY..................................................................................................................... 12 3. TEST SOFTWARE .................................................................................................................. 12 4. TEST EQUIPMENT AND TEST SITE .................................................................................. 13 5. CONDUCTED EMISSION ...................................................................................................... 14 5.1 Test Standard and Limit ................................................................................................... 14 5.2 Test Setup........................................................................................................................... 14 5.3 Test Procedure .................................................................................................................. 14 5.4 Deviation From Test Standard......................................................................................... 14 5.5 EUT Operating Mode ........................................................................................................ 15 5.6 Test Data............................................................................................................................. 15 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 16 6.1 Test Standard and Limit ................................................................................................... 16 6.2 Test Setup........................................................................................................................... 17 6.3 Test Procedure .................................................................................................................. 18 6.4 Deviation From Test Standard......................................................................................... 19 6.5 EUT Operating Mode ........................................................................................................ 19 6.6 Test Data............................................................................................................................. 19 7. RESTRICTED BANDS AND BAND EDGE REQUIREMENT .......................................... 20 7.1 Test Standard and Limit ................................................................................................... 20 7.2 Test Setup........................................................................................................................... 20 7.3 Test Procedure .................................................................................................................. 21 7.4 Deviation From Test Standard......................................................................................... 21 7.5 EUT Operating Mode ........................................................................................................ 21 7.6 Test Data............................................................................................................................. 21 8. 99% OCCUPIED AND 20DB BANDWIDTH ............................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shelly Lu
[email protected]Fax: N/A

Technical Contact

ACT Lab LLCScott Huber
[email protected]

3280 East 59th Street,Long Beach, · United States

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.90 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.