FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Beijing Shenmou Technology Co., Ltd/
  3. 2BUGI-SMKJ-I

2BUGI-SMKJ-ISleep health monitor

Beijing Shenmou Technology Co., Ltd
Sleep health monitor - FCC ID 2BUGI-SMKJ-I - Beijing Shenmou Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 04, 2026
Application Purpose
Original Equipment
Equipment Note
Sleep health monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Beijing Shenmou Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

manual Product Introduction Positioning and Core Technology Shenmou Technology's Carnation Smart Monitor integrates sensor technology, AI algorithms, and a health database to provide 24/7 accurate monitoring of heart rate and respiration without contact or radiation, achieving seamless health protection. Core Functions and Health Management Based on LSTM neural network analysis of HRV and sleep quality, it provides early warnings of sleep apnea and arrhythmia risks, generates weekly/monthly reports, and offers health recommendations. It models the baseline period (1-30 days), dynamic period (31-90 days), and inter- vention period (91+ days) to construct a closed loop of monitoring, early warning, intervention, and tracking. Application scenarios and differentiat- ing advantages For home-based elderly care, post-opera- tive rehabilitation, and sub-healthy individuals, high precision and privacy are ensured through multi-terminal synchro- nization; invisible monitoring is integrated into daily scenarios, practicing "invisible technology, visible health," and reshaping the standards of intelligent health moni- toring. Parameters Model:SMKJ-I Input:5V/2A IP:IPX0 Operating temperature:0~40°C Operating humidity:10%~90%RH Function Introduction Dynamic heart rate Heart health Respiratory function test Sleep quality analysis Continuous heart rate HRV OSA/Breath analysis Multistage sleep stages Reflecting dynamic changesin the cardiovascular system Quantifying autonomic nervous system regulation capabilities Warning signs of obstructive sleep problems Constructing a sleep structure map TypeFunctionValue 1.Real-time vital signs monitoring Cardiovascular risk warning Sleep Disorder Assessment Psychological state assessment Autonomic nervous system assessment HRV Nonlinear Analysis Model AHI Classification Index Physiological signal quantification analysis Sympathetic-vagal balance assessment Predicting the risk of cardiac arrhythmia OSA Analysis Report Stress Health Report and Guidance Generate autonomic nervous system reports TypeIndexWarning content 2.Risk warning and assessment Equipment installation 1.Connecting devices Data acquisition Main control module power cord adapter Data line Please connect the device according to the hardware connection diagram. 2.Install Please install the device according to the installation diagram. Place the data acquisition module under the mattress at the chest and abdomen position (if there are multiple mattresses, place it under the mattress closest to your body). Place the main control module at the head of the bed or stick it to the wall after binding the device. The device will automatically activate after being plugged in. Data acquisition Main control Device binding Scan the QR code with your phone to access the Deepwise Healthcare Platform and download the SYSMO Smart Treasure APP, or search for the "sysmo" APP in your mobile app store to download and install it. Follow the prompts to complete the binding process. V1.0 Safety Usage Guide 1. Do not use this device in medical settings where wireless devices are prohibited (such as ICUs and operating rooms). 2. This device is not waterproof; do not wash or allow it to come into contact with liquids. 3. The device and accessories contain small parts; keep them out of reach of children. 4. Children must be supervised by an adult at all times while using the device to prevent accidental swallowing of parts or damage. 5. Use only the officially certified power adapter. Do not use incompatible accessories to prevent short circuits or fires. 6. Avoid placing the device in high-temperature, humid, direct sunlight, or strong vibration environ- ments. 7. Do not disassemble the device yourself. Contact official customer service for assistance in case of malfunction. FCC Compliance Statement Software Copyright Notice The products described in this manual include software copyrighted by Beijing Shenmou Technology Co., Ltd. and its licensors. Any unauthorized copying, distribution, modification, or excerpting of the software is considered an infringe- ment of software copyright unless expressly permitted by the relevant rights holder or otherwise stipulated by applica- ble law. Data and privacy security Upgrading your device's firmware and system using unauthorized third-party software may cause your device to malfunction or leak your personal infor- mation, posing a security risk. To understand how we protect your personal information, please carefully read the Carnation User Agreement. Precautions Frequently Asked Questions No report Data missing in report The power cord or data transmission cable is loose or has come loose. The device was not placed below the chest and abdomen; the user was outside the effective measurement range of the data acquisition module. Sensor not connected Check that all parts of the product are properly connected. During placement, confirm that the data module is located in the lower part of the chest and abdomen. Confirm sensor connection is intact QuestionReasonSolution Real-time anomaly detection The system is currently disconnected from the bed and has not been installed in the designated location. No data uploaded. Reasons include: device not started, network not connected. Install the equipment in the designated position, keeping it below the chest and abdomen. Confirm that the device has started normally and that the network connection is normal. If necessary, please restart the device. Manufacturer (Brand Owner): Beijing Shen- mou Technology Co., Ltd. Manufacturer Address: 16F, Building 3, Huamao Center, No. 77 Jianguo Road, Chaoyang District, Beijing Email: [email protected] Website: www.sysmoaisystems.com Postcode: 100025 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired oper…

Text truncated - open the document above for the full version.

Attestation Statements

Jan 2026

Attestation Statements

Beijing Shenmou Technology Co., Ltd (160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China) Attestation Statements Not Covered Entity Applicant & Not Covered Equipment To: Federal Communications Commission Date: (2026/1/26) 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) & (ii) FCC ID: 2BUGI-SMKJ-I Beijing Shenmou Technology Co., Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List, established pursuant to § 1.50002 of reference chapter, as an entity producing “covered” communication equipment. The equipment for which authorization is sought is not “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List that prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Printed Name: Rex Wu Title: Manager Address: 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Tel.: 17633031885 Email: [email protected]

Attestation Statements

1 | P a g e Beijing Shenmou Technology Co., Ltd (160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China) Attestation Statements To: Federal Communications Commission Date: (2026/1/26) 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Attestation of Compliance with FCC Covered List Software Requirements FCC ID: [2BUGI-SMKJ-I] Product Name: [Sleep health monitor] This letter serves as an attestation that the equipment identified above ☐ is / ☒ is not (select one) "covered" software as defined under the Federal Communications Commission (FCC) Covered List requirements, as outlined in FCC 22-84 and KDB 986446. Specifically, the undersigned certifies that the equipment for which authorization is sought: 1. Does not contain cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors, assignees, parents, subsidiaries, affiliates, or any entity that has rebranded or relabeled software produced by the aforementioned entities. 2. Does not have the capability to store, run, or deliver any software identified on the FCC Covered List, including but not limited to cybersecurity and anti-virus software. To support this attestation, the appendix evaluation documentation has been prepared and is included in the certification filing. This attestation is based on a thorough evaluation of the device's design, functionality, and software environment. The undersigned affirms that the information provided is accurate and complete to the best of their knowledge. Sincerely yours, Applicant Signature Applicant Signature Printed Name: Rex Wu Title: Manager Address: 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China 2 | P a g e Evaluation regarding to the Covered List Software: Compliance Methodology Evaluation Process Results Device is Inherent compliance ☒ The Chipset(s) used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ The Memory used is limited to run the Cybersecurity or anti-virus software. Compliance ☒ There is storage capacity limitation for store or install the Cybersecurity or anti-virus software. Compliance ☒ Operating system used is limited to run, install or deliver the Cybersecurity or anti-virus software. Compliance Device is not Inherent compliance ☐ Evaluation Based on Software Bill of Materials (SBoM) See attached “SBoM“ Note:The SBoM content is limited to the scope of covered list software (e.g. antivirus and cybersecurity software). ☐ Evaluation Based on Scan for Software on the device ☐ Evaluation Based on Filesystem scan ☐ Evaluation Based on Running software check

Cover Letter(s)

Beijing Shenmou Technology Co., Ltd (160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China) (2026/1/26) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization for FCC ID: 2BUGI-SMKJ-I I, the undersigned, hereby authorize (Shenzhen STS Test Services Co., Ltd.) to act on our behalf in all matters relating to this application for equipment certification. Any act carried out by (Shenzhen STS Test Services Co., Ltd.) shall have the same effect as our own and I acknowledge that all responsibility for complying with the terms and conditions of certification, as specified by DERYCOM CERTIFICATION SERVICES, INC., still resides with (Beijing Shenmou Technology Co., Ltd). We certify that we are not subject to a denial of federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862, and that no party to the application, as defined in 47 CFR §1.2002(b), is subject to a denial of federal benefits that includes FCC benefits pursuant to that section. Sincerely, (Signature) (Full name of contact person listed on FCC’s website): Rex Wu (Title): Manager Tel: 17633031885 Fax: / Email: [email protected]

Cover Letter(s)

Beijing Shenmou Technology Co., Ltd (160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China) (2026/1/26) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Confidentiality Request for: FCC ID: 2BUGI-SMKJ-I Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request permanent confidential treatment of the exhibits accompanying this certification application as outlined below :  Block Diagram  Schematics  Operational Description The above exhibits contain trade secrets and/or proprietary information that are not publicly available and materials that the Applicant has spent considerable efforts in developing. Public disclosure of these may be harmful to the Applicant and give an unfair advantage to competitors on the market. Sincerely, (Signature) Title: Manager Address: 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Tel.: 17633031885 Email: [email protected]

External Photos

Page 1 of 8 FCC ID: 2BUGI-SMKJ-I External Photos Page 2 of 8 FCC ID: 2BUGI-SMKJ-I Page 3 of 8 FCC ID: 2BUGI-SMKJ-I Page 4 of 8 FCC ID: 2BUGI-SMKJ-I Page 5 of 8 FCC ID: 2BUGI-SMKJ-I

ID Label/Location Info

Label & label location Location: Label: FCC ID: 2BUGI-SMKJ-I This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Page 6 of 8 FCC ID: 2BUGI-SMKJ-I Internal Photos Antenna Page 7 of 8 FCC ID: 2BUGI-SMKJ-I Page 8 of 8 FCC ID: 2BUGI-SMKJ-I

RF Exposure Info

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the ShenZhen STS Test Services Co., Ltd. MPE Report Report No.:STS2601328H01 Issued for Beijing Shenmou Technology Co., Ltd 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Product Name: Sleep health monitor Brand Name: SYSMO Model Name: SMKJ-I Series Model(s): N/A FCC ID: 2BUGI-SMKJ-I Test Standard: FCC 47CFR §2.1091 Page 2 of 7 Report No.: STS2601328H01 TEST REPORT Applicant’s Name ................. : Beijing Shenmou Technology Co., Ltd Address ................................. : 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Manufacturer's Name ........... : Beijing Shenmou Technology Co., Ltd Address ................................. : 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Product Description Product Name ........................ : Sleep health monitor Brand Name .......................... : SYSMO Model Name .......................... : SMKJ-I Series Model(s) ...................... : N/A Test Standards ..................... : FCC 47CFR §2.1091 447498 D01 Interim General RF Exposure Guidance v06 The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the ShenZhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ...................... : 12 Jan. 2026 Date (s) of performance of tests ............. : 12 Jan. 2026 to 15 Jan. 2026 Date of Issue .......................................... : 15 Jan. 2026 Test Result .............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 7 Report No.: STS2601328H01 TABLE OF CONTENTS 1. GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST FACTORY 5 2. FCC 47CFR §2.1091 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 TEST RESULT 7 Page 4 of 7 Report No.: STS2601328H01 Revision History Rev. Issue Date Report No. Effect Page Contents 00 15 Jan. 2026 STS2601328W02 ALL Initial Issue Page 5 of 7 Report No.: STS2601328H01 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name Sleep health monitor Brand Name SYSMO Model Name SMKJ-I Series Model(s) N/A Model Difference N/A Product Description The EUT is a Sleep health monitor Operation Frequency: BLE: 2402 – 2480 MHz 2.4G WIFI: 2412-2462 MHz Modulation Type: BLE: GFSK 2.4G WIFI: 802.11b(DSSS):CCK,DQPSK,DBPSK 802.11g(OFDM):BPSK,QPSK,16-QAM,64- QAM 802.11n(OFDM):BPSK,QPSK,16-QAM,64- QAM Antenna Type: Internal antenna Antenna Gain (dBi) 2.46 Power Rating DC 5V from adapter Adapter Manufacture: Guangdong Qingliu Electronics Co.,LTD Model: QL010-0502000UU Input: 100-240V~50/60Hz 0.45A Output: 5.0V2A Battery N/A Hardware Version N/A Software Version N/A 1.2 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 Page 6 of 7 Report No.: STS2601328H01 2. FCC 47CFR §2.1091 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) Limits for Maximum Permissible Exposure (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 300 - 1500 -- -- F/300 3.0-30 1842/f 4.89/f *(900/f²) 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 300 - 1500 -- -- F/1500 1.34-30 824/f 2.19/f *(180f²) 1500 – 100000 -- -- 1.0 F= Frequency in MHz Friss Formula Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. Page 7 of 7 Report No.: STS2601328H01 2.3 TEST RESULT Tune up Mode Detector Tune up Power BLE Peak -1±1dBm 2.4G WIFI Peak 14±1dBm For Simultaneous Transmitting: the ratio=BLE/ Limit +2.4G WIFI/Limit=0.0004/1+0.0111/1=0.0115≤1 Note: 1. The Maxinum power is less than the limit, complies with the exemption requirements. 2. ERP = EIRP - 2.15 ※※※※※END OF THE REPORT※※※※※ Protocol Fre. (GHz) Separati on distance (cm) Max Tune up power (dBm) ANT Gain (dBi) Max EIRP (dBm) Max EIRP (mW) Power Density (mW/cm²) Limit (mW/ cm²) Ratio Result BLE 2.440 20 0 2.46 2.46 1.762 0.0004 1 0.0004 Pass 2.4G WIFI 2.462 20 15 2.46 17.46 55.719 0.0111 1 0.0111 Pass

Test Report

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2601328W01 Issued for Beijing Shenmou Technology Co., Ltd 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Product Name: Sleep health monitor Brand Name: SYSMO Model Name: SMKJ-I Series Model(s): N/A FCC ID: 2BUGI-SMKJ-I Test Standards: FCC Part15.247 Page 2 of 69 Report No.: STS2601328W01 TEST REPORT Applicant’s Name ................. : Beijing Shenmou Technology Co., Ltd Address ................................. : 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Manufacturer's Name ........... : Beijing Shenmou Technology Co., Ltd Address ................................. : 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Product Description Product Name ........................ : Sleep health monitor Brand Name ........................... : SYSMO Model Name .......................... : SMKJ-I Series Model(s) .................... : N/A Standards ............................. : FCC Part 15.247 Test Procedure........................: ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ...................... : 12 Jan. 2026 Date (s) of performance of tests ............. : 12 Jan. 2026 to 15 Jan. 2026 Date of Issue .......................................... : 15 Jan. 2026 Test Result .............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 69 Report No.: STS2601328W01 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 10 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 RADIATED EMISSION MEASUREMENT 17 4. CONDUCTED SPURIOUS & BAND EDGE EMISSION 31 4.1 LIMIT 31 4.2 TEST PROCEDURE 31 4.3 DEVIATION FROM STANDARD 31 4.4 TEST SETUP 31 4.5 EUT OPERATION CONDITIONS 31 4.6 TEST RESULTS 31 5. POWER SPECTRAL DENSITY TEST 32 5.1 LIMIT 32 5.2 TEST PROCEDURE 32 5.3 DEVIATION FROM STANDARD 32 5.4 TEST SETUP 32 5.5 EUT OPERATION CONDITIONS 32 5.6 TEST RESULTS 32 6. BANDWIDTH TEST 33 6.1 LIMIT 33 6.2 TEST PROCEDURE 33 6.3 DEVIATION FROM STANDARD 33 6.4 TEST SETUP 33 6.5 EUT OPERATION CONDITIONS 33 Page 4 of 69 Report No.: STS2601328W01 Table of Contents Page 6.6 TEST RESULTS 33 7. PEAK OUTPUT POWER TEST 34 7.1 LIMIT 34 7.2 TEST PROCEDURE 34 7.3 DEVIATION FROM STANDARD 34 7.4 TEST SETUP 34 7.5 EUT OPERATION CONDITIONS 34 7.6 TEST RESULTS 34 8. ANTENNA REQUIREMENT 35 8.1 STANDARD REQUIREMENT 35 8.2 EUT ANTENNA 35 APPENDIX 1-TEST DATA 36 DUTY CYCLE 36 MAXIMUM CONDUCTED OUTPUT POWER 39 -6DB BANDWIDTH 40 MAXIMUM POWER SPECTRAL DENSITY LEVEL 46 BAND EDGE 52 CONDUCTED RF SPURIOUS EMISSION 59 APPENDIX 2-PHOTOS OF TEST SETUP 69 Page 5 of 69 Report No.: STS2601328W01 Revision History Rev. Issue Date Report No. Effect Page Contents 00 15 Jan. 2026 STS2601328W01 ALL Initial Issue Page 6 of 69 Report No.: STS2601328W01 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted Band Edge Emission PASS -- Part 15.247(d)/ part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- NOTE: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 69 Report No.: STS2601328W01 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.751dB 2 Unwanted Emissions, conducted ±2.888dB 3 All emissions, radiated 9K-30MHz ±2.48dB 4 All emissions, radiated 30M-1GHz ±2.52dB 5 All emissions, radiated 1G-18GHz ±3.48dB 6 All emissions, radiated>18GHz ±4.18dB 7 Conducted Emission (9KHz-150KHz) ±2.48dB 8 Conducted Emission (150KHz-30MHz) ±2.52dB 9 Occupied Channel Bandwidth ±3.6% 10 Power Spectral Density, conducted ±1.214dB 11 Duty Cycle ±3.2% Page 8 of 69 Report No.: STS2601328W01 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name Sleep health monitor Brand Name SYSMO Model Name SMKJ-I Series Model(s) N/A Model Difference N/A Product Description…

Text truncated - open the document above for the full version.

Test Report

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.:STS2601328W02 Issued for Beijing Shenmou Technology Co., Ltd 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Product Name: Sleep health monitor Brand Name: SYSMO Model Name: SMKJ-I Series Model(s): N/A FCC ID: 2BUGI-SMKJ-I Test Standards: FCC Part15.247 Page 2 of 55 Report No.: STS2601328W02 TEST REPORT Applicant’s Name ................. : Beijing Shenmou Technology Co., Ltd Address ................................. : 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Manufacturer's Name .......... : Beijing Shenmou Technology Co., Ltd Address ................................. : 160, 05th floor, within 101, 1st to 14th floors, Building 4, Yard 59, Chemical Road, Chaoyang District, Beijing, China Product Description Product Name ....................... : Sleep health monitor Brand Name .......................... : SYSMO Model Name .......................... : ... : SMKJ-I Series Model(s) .................... : N/A Test Standards ..................... : FCC Part15.247 Test Procedure ...................... : ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the IC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ..................... : 12 Jan. 2026 Date (s) of performance of tests ............. : 12 Jan. 2026 to 15 Jan. 2026 Date of Issue .......................................... : 15 Jan. 2026 Test Result.............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 55 Report No.: STS2601328W02 Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 TEST SOFTWARE AND POWER LEVEL 10 2.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.5 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.6 EQUIPMENTS LIST 12 3. EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.2 TEST PROCEDURE 14 3.3 TEST SETUP 14 3.4 EUT OPERATING CONDITIONS 14 3.5 TEST RESULTS 15 4. RADIATED EMISSION MEASUREMENT 17 4.1 RADIATED EMISSION LIMITS 17 4.2 TEST PROCEDURE 19 4.3 TEST SETUP 20 4.4 EUT OPERATING CONDITIONS 20 4.5 FIELD STRENGTH CALCULATION 21 4.6 TEST RESULTS 22 5. CONDUCTED SPURIOUS & BAND EDGE EMISSION 31 5.1 LIMIT 31 5.2 TEST PROCEDURE 31 5.3 TEST SETUP 31 5.4 EUT OPERATION CONDITIONS 31 5.5 TEST RESULTS 31 6. POWER SPECTRAL DENSITY TEST 32 6.1 LIMIT 32 Page 4 of 55 Report No.: STS2601328W02 Table of Contents Page 6.2 TEST PROCEDURE 32 6.3 TEST SETUP 32 6.4 EUT OPERATION CONDITIONS 32 6.5 TEST RESULTS 32 7. BANDWIDTH TEST 33 7.1 LIMIT 33 7.2 TEST PROCEDURE 33 7.3 TEST SETUP 33 7.4 EUT OPERATION CONDITIONS 33 7.5 TEST RESULTS 33 8. PEAK OUTPUT POWER TEST 34 8.1 LIMIT 34 8.2 TEST PROCEDURE 34 8.3 TEST SETUP 34 8.4 EUT OPERATION CONDITIONS 34 8.5 TEST RESULTS 34 9. ANTENNA REQUIREMENT 35 9.1 STANDARD REQUIREMENT 35 9.2 EUT ANTENNA 35 APPENDIX 1-TEST DATA 36 DUTY CYCLE 36 MAXIMUM CONDUCTED OUTPUT POWER 39 -6DB BANDWIDTH 42 MAXIMUM POWER SPECTRAL DENSITY LEVEL 45 BAND EDGE 48 CONDUCTED RF SPURIOUS EMISSION 51 APPENDIX 2- EUT TEST PHOTO 55 Page 5 of 55 Report No.: STS2601328W02 Revision History Rev. Issue Date Report No. Effect Page Contents 00 15 Jan. 2026 STS2601328W02 ALL Initial Issue Page 6 of 55 Report No.: STS2601328W02 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 558074 D01 15.247 Meas Guidance v05r02. FCC Part 15.247,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission PASS -- 15.247 (a)(2) 6dB Bandwidth PASS -- 15.247 (b)(3) Output Power PASS -- 15.209 Radiated Spurious Emission PASS -- 15.247 (d) Conducted Spurious & Band Edge Emission PASS -- 15.247 (e) Power Spectral Density PASS -- 15.205 Restricted bands of operation PASS -- Part 15.247(d)/ Part 15.209(a) Band Edge Emission PASS -- 15.203 Antenna Requirement PASS -- Note: (1) ‘N/A’ denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. Page 7 of 55 Report No.: STS2601328W02 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Numb…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Rex Wu
[email protected]Fax: /

Technical Contact

Baihetian Innovative SolutionsKenneth Young
[email protected]

6837 Chase Rd · Dearborn, Michigan, 48126 · United States

Test Firm

SHENZHEN STS TEST SERVICES CO.,LTD.Bovey Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz880.00 µW
215C2.41 GHz - 2.46 GHz26.85 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.