  3. 2BUIO-SY-HRC10

2BUIO-SY-HRC10Soft Rehabilitation Glove

Shanghai SiYi Intelligent Technology Co.,Ltd.
Soft Rehabilitation Glove - FCC ID 2BUIO-SY-HRC10 - Shanghai SiYi Intelligent Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 16, 2026
Application Purpose
Original Equipment
Equipment Note
Soft Rehabilitation Glove
Frequency Range
2402.00000000 - 2480.00000000
Company
Shanghai SiYi Intelligent Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

『 FCC Requirement: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BUIO-SY-HRC10 SY-HRC10, SY-HRC11, SY-HRC15, SY-HRE12, SY- HRF12, HRE10 We, Applicant Company Name: Shanghai SiYi Intelligent Technology Co., Ltd. Address: 2F, 13 Building, No.2388, Xiupu Road, Pudong Dist, Shanghai 201315, P.R.China Phone: +86-21-61014634 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-03-10 Signature Date Name / Title: XIANWEN LIU / Manager Company: Shanghai SiYi Intelligent Technology Co., Ltd. Address: 2F, 13 Building, No.2388, Xiupu Road, Pudong Dist, Shanghai 201315, P.R.China Phone: +86-21-61014634 Fax: N/A E-Mail: [email protected]

Attestation Statements

Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2BUIO-SY-HRC10 SY-HRC10, SY-HRC11, SY-HRC15, SY-HRE12, SY- HRF12, HRE10 Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen Huaxia Testing Technology Co., Ltd Contact Name: Yoyo Zhou Address: 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Phone: +86-755-26648642 Email: [email protected] Signature: Date: 2026-02-10

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BUIO-SY-HRC10 SY-HRC10, SY-HRC11, SY-HRC15, SY-HRE12, SY- HRF12, HRE10 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-03-10 Signature Date Name / Title: XIANWEN LIU / Manager Company: Shanghai SiYi Intelligent Technology Co., Ltd. Address: 2F, 13 Building, No.2388, Xiupu Road, Pudong Dist, Shanghai 201315, P.R.China Phone: +86-21-61014634 Fax: N/A E-Mail: [email protected]

Cover Letter(s)

ShanghaiSiYiIntelligentTechnologyCo.,Ltd. ModelConfirmationLetter We,ShanghaiSiYiIntelligentTechnologyCo.,Ltd.certifytheproduct: Dataglove ModelNo.: SY-HRC10,SY-HRC11,SY-HRC15,SY-HRE12,SY-HRF12,HRE10 FCCID: 2BUIO-SY-HRC10 Theirelectricalcircuitdesign,layout,componentsusedandinternalwiringareidentical, Onlytheappearanceandfunctionweredifferent. Signiture: GranteeContact:XIANWENLIU CompanyName:ShanghaiSiYiIntelligentTechnologyCo.,Ltd. Date:March6,2026

External Photos

Externalphotos FCC ID: 2BUIO-SY-HRC10

Internal Photos

Internalphotos FCC ID: 2BUIO-SY-HRC10 ANT

RF Exposure Info

SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 RFExposureEvaluationReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonlyto thesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260100022E-02 Applicant: ShanghaiSiYiIntelligentTechnologyCo.,Ltd. AddressofApplicant: 2F,13Building,No.2388,XiupuRoad,PudongDist,Shanghai,P.R.China, 201315 EquipmentUnderTest(EUT): EUTName:SoftRehabilitationGlove TestModelNo.:SY-HRC10,SY-HRC11,SY-HRC15,SY-HRE12,SY-HRF12,HRE10 ModelNo.:SY-HRC10 BrandName:SYREBO FCCID:2BUIO-SY-HRC10 Standards: 47CFRPart1.1307 47CFRPart2.1093 447498D04InterimGeneralRFExposureGuidancev01 DateofReceipt:2026-01-04 DateofTest:2026-01-04to2026-02-05 DateofIssue:2026-02-10 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260100022E-02 Page:2of7 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260100022E-02Rev.01 Initialreport 2026-02-10 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260100022E-02 Page:3of7 2Contents Page 1VERSION............................................................................................................................................................................2 2CONTENTS........................................................................................................................................................................3 3GENERALINFORMATION..............................................................................................................................................4 3.1CLIENTINFORMATION...................................................................................................................................................4 3.2GENERALDESCRIPTIONOFEUT...................................................................................................................................4 3.3GENERALDESCRIPTIONOFBLE...................................................................................................................................4 4SAREVALUATION...........................................................................................................................................................5 4.1RFEXPOSURECOMPLIANCEREQUIREMENT.................................................................................................................5 4.1.1StandardRequirement......................................................................................................................................5 4.1.2Limits....................................................................................................................................................................5 4.1.3EUTRFExposure..............................................................................................................................................7 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260100022E-02 Page:4of7 3GeneralInformation 3.1ClientInformation Applicant: ShanghaiSiYiIntelligentTechnologyCo.,Ltd. AddressofApplicant: 2F,13Building,No.2388,XiupuRoad,PudongDist,Shanghai, P.R.China, 201315 Manufacturer: FoshanShundeShannuoElectronicsCo.,Ltd AddressofManufacturer: Room701-2,Building6,District2,WanyangScienceandTechnology InnovationPark,No.1,HuangyongIndustrialAvenue,HuanglongVillage, BeijiaoTown,ShundeDistrict,FoshanCity,GuangdongProvince Factory: FoshanShundeShannuoElectronicsCo.,Ltd AddressofFactory: Room701-2,Building6,District2,WanyangScienceandTechnology InnovationPark,No.1,HuangyongIndustrialAvenue,HuanglongVillage, BeijiaoTown,ShundeDistrict,FoshanCity,GuangdongProvince 3.2GeneralDescriptionofEUT ProductName: SoftRehabilitationGlove ModelNo.: SY-HRC10,SY-HRC11,SY-HRC15,SY-HRE12,SY-HRF12,HRE10 TestModelNo SY-HRC10 TradeMark: SYREBO EUTSupportsRadiosapplication:Bluetooth:2402-2480MHz SoftwareVersion: V1.0 HardwareVersion: V1.0 SampleType: MobilePortableFixLocation EUTPowerSupply: Li-ionbatteryDC3.7V1200mAh*2,ChargebyDC5Vforadapter 3.3GeneralDescriptionofBLE OperationFrequency: 2402MHz~2480MHz BluetoothVersion: 5.0 ModulationTechnique: NonFrequencyHoppingSpreadSpectrum(NFHSS) ModulationType: GFSK NumberofChannel: 40 TransferRate:1Mbps TestSoftwareofEUT: flash_tool AntennaType:PCBantenna AntennaGain:1.5dBi SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260100022E-02 Page:5of7 4SAREvaluation 4.1RFExposureComplianceRequirement 4.1.1StandardRequirement 447498D04InterimGeneralRFExposureGuidancev01 3.2.SARTestReductionGuidance SARtestreductionprocedures[Glossary]allowusingaparticularsetoftestdataas representativeofother,similar,testconditions.Thismaybeappliedfordatawithindifferenttest positions(e.g.body,head,extremity),wirelessmodes(e.g.Wi-Fi,cellular),andfrequencybands.This testreductionprocessprovidesfortheuseoftestdataforonespecificchannel,whilereferencingto thosedatafordemonstratingcomplianceinotherrequiredchannelsforeachtestpositionofan exposurecondition,withintheoperatingmodeofafrequencyband.Thisislimitedspecificallytowhen thereported1-gor10-gSARforthemid-bandorhighestoutputpowerchannelmeetsanyofthe followingconditions. 4.1.2Limits SAR-basedthresholdsarederivedbasedonfrequency,power,andseparationdistanceoftheRF source.Theformuladefinesthethresholdsingeneralforeitheravailablemaximumtime averaged powerormaximumtime-averagedERP,whicheverisgreater. IftheERPofadeviceisnoteasilydetermined,suchasforaportabledevicewithasmallform factor,theapplicantmayusetheavailablemaximumtime-averagedpowerexclusivelyifthe deviceantennao…

Text truncated - open the document above for the full version.

Test Report

Inverted F Antenna Specification Summary ITEM ANT SPEC Model Name 2.4G ANT Center Frequency Horizontal Vertical 2400MHZ 2450MHZ 2500MHZ 2400MHZ 2450MHZ 2500MHZ -1.26 -0.76 -1.5 -5.25 -2.46 -1.86 Max Gain 1.5dBi Polarization Horizontal and Vertical Azimuth Beam Pattem Omni-directional Impedance 50 Ohm Antenna type PCB Antenna Manufacture Shenzhen Bluetrum Technology Co.,Ltd Address 13F, Unit 1, Building A, Wisdom Plaza, No. 4068 Qiaoxiang Road, Gaofa Community Shahe Street, Nanshan District, Shenzhen Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Shenzhen Bluetrum Technology Co., Ltd. Address: 13F, Unit 1, Building A, Wisdom Plaza, No. 4068 Qiaoxiang Road, Gaofa Community , Shahe Street, Nanshan District, Shenzhen Frequency (MHz) Gain(dBi) Max Min Avg 2400 -1.26174 -30.0801 -7.18716 2450 -0.765802 -36.5604 -7.48023 2500 1.5 -22.0315 -6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Frequency (MHz) Gain(dB) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86 -29.5214 -9.20432 ANT Test Labs : Attestation of Global Compliance Co., Ltd.

Test Report

SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD 102A,102B,Building2,ShanghenglangNewIndustrialZone,ShanghenglangCommunity, DalangStreet,LonghuaDistrict,Shenzhen,Guangdong,People’sRepublicofChina,518000 Telephone:+86-755-26648640 Fax:+86-755-26648637 Website:www.cqa-cert.com ReportTemplateVersion:V06 ReportTemplateRevisionDate:2026-01-30 TestReport Thetestreportiseffectiveonlywithbothsignatureandspecializedstamp,Theresult(s)showninthisreportreferonly tothesample(s)tested.WithoutwrittenapprovalofCQA,thisreportcan’tbereproducedexceptinfull. ReportNo.:CQASZ20260100022E-01 Applicant: ShanghaiSiYiIntelligentTechnologyCo.,Ltd. AddressofApplicant: 2F,13Building,No.2388,XiupuRoad,PudongDist,Shanghai,P.R.China, 201315 EquipmentUnderTest(EUT): Product:SoftRehabilitationGlove ModelNo.:SY-HRC10,SY-HRC11,SY-HRC15,SY-HRE12,SY-HRF12,HRE10 TestModelNo.:SY-HRC10 BrandName:SYREBO FCCID:2BUIO-SY-HRC10 Standards:47CFRPart15,SubpartC KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10:2020 DateofReceipt:2026-01-04 DateofTest:2026-01-04to2026-02-05 DateofIssue:2026-02-10 TestResult:PASS* *Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. TestedBy: (LewisZhou) ReviewedBy: (TimoLei) ApprovedBy: (JackAi) SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260100022E-01 Page: 2 of 52 1Version RevisionHistoryOfReport ReportNo.Version Description IssueDate CQASZ20260100022E-01Rev.01Initialreport2026-02-10 SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260100022E-01 Page: 3 of 52 2TestSummary TestItemTestRequirementTestmethodResult AntennaRequirement 47CFRPart15,SubpartCSection 15.203/15.247(c) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ACPowerLine Conducted Emission 47CFRPart15,SubpartCSection 15.207 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS ConductedPeakOutput Power 47CFRPart15,SubpartCSection 15.247(b)(3) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS 6dBOccupied Bandwidth 47CFRPart15,SubpartCSection 15.247(a)(2) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS PowerSpectralDensity 47CFRPart15,SubpartCSection 15.247(e) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Band-edgeforRF ConductedEmissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RFConductedSpurious Emissions 47CFRPart15,SubpartCSection 15.247(d) ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS RadiatedSpurious Emissions 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS Restrictedbandsaround fundamentalfrequency (RadiatedEmission) 47CFRPart15,SubpartCSection 15.205/15.209 ANSI C63.10- 2020+Cor.1- 2023+C63.10a-2024+ ErratatoC63.10a-2024 PASS SHENZHENHUAXIATESTINGTECHNOLOGYCO.,LTD ReportNo.:CQASZ20260100022E-01 Page: 4 of 52 3Contents Page 1VERSION..........................................................................................................................................................................2 2TESTSUMMARY............................................................................................................................................................3 3CONTENTS......................................................................................................................................................................4 4GENERALINFORMATION...........................................................................................................................................5 4.1CLIENTINFORMATION.................................................................................................................................................5 4.2GENERALDESCRIPTIONOFEUT.................................................................................................................................5 4.3ADDITIONALINSTRUCTIONS........................................................................................................................................7 4.4TESTENVIRONMENT...................................................................................................................................................8 4.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................................................8 4.6TESTCONFIGURATION................................................................................................................................................8 4.7STATEMENTOFTHEMEASUREMENTUNCERTAINTY....................................................................................................9 4.8TESTLOCATION........................................................................................................................................................10 4.9TESTFACILITY..........................................................................................................................................................10 4.10DEVIATIONFROMSTANDARDS................................................................................................................................10 4.11OTHERINFORMATIONREQUESTEDBYTHECUSTOMER..........................................................................................10 4.12EQUIPMENTLIST.....................................................................................................................................................11 5TESTRESULTSANDMEASUREMENTDATA.....................................................................................................12 5.1ANTENNAREQUIREMENT..........................................................................................................................................12 5.2CONDUCTEDEMISSIONS............................................................................................................................................13 5.3CONDUCTEDPEAKOUTPUT…

Text truncated - open the document above for the full version.

Test Setup Photos

Setupphotos 1Photographs-EUTTestSetup 1.1RadiatedSpuriousEmission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2BUIO-SY-HRC10 Above1GHz: 1.2ConductedEmissionsTestSetup 1.3RFConductedmeasurement

Contact Information

Applicant

XIANWEN LIU(Manager)
[email protected]Fax: 021-61014634

Technical Contact

FCC US Agent Inc.David Wilson
[email protected]

6464 Dillon Dr Unit 93 Pueblo · Colorado, 81008 · United States

Test Firm

Shenzhen Huaxia Testing Technology Co., LtdJack Ai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz970.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Shanghai SiYi Intelligent Technology Co.,Ltd.

Data glove - FCC ID 2BUIO-SY-HRE12 - Shanghai SiYi Intelligent Technology Co.,Ltd.
2BUIO-SY-HRE12

Data glove

Mar 13, 2026

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter