FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ehoma Industrial Corporation/
  3. 2BUIVTKW26001

2BUIVTKW26001MagCharge Plate Wireless Charging Module

Ehoma Industrial Corporation
MagCharge Plate Wireless Charging Module - FCC ID 2BUIVTKW26001 - Ehoma Industrial Corporation
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 08, 2026
Application Purpose
Original Equipment
Equipment Note
MagCharge Plate Wireless Charging Module
Frequency Range
0.11050000 - 0.20500000
Company
Ehoma Industrial Corporation
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

( Warning ) - - Operation Instructions : Precautions : Positive Pole Button Power Control Box FCC Warning Statement" This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Polybrominated Polybrominated diphenyl ethers Plate Printed XXXXXXXX FCC ID XXXXXXX Product NameMagCharge Plate Wireless Charging Module Model T-MP03 Input Voltage DC12V/1A Output Power 5W XXXXXXXX FCC ID XXXXXXX Product NameMagCharge Plate Wireless Charging Module Model PH06 PRO Input Voltage DC12V/1A Output Power 5W XXXXXXXX FCC ID XXXXXXX Product NameMagCharge Plate Wireless Charging Module Model T-MP03 Input VoltageDC12V/1A Output Power 5W XXXXXXXX FCC ID XXXXXXX Product NameMagCharge Plate Wireless Charging Module Model PH06 PRO Input VoltageDC12V/1A Output Power 5W XXXXXXXX FCC ID XXXXXXX MagCharge Plate T-MP03 DC12V/1A 5W XXXXXXXX FCC ID XXXXXXX MagCharge Plate PH06 PRO DC12V/1A 5W XXXXXXXX FCC ID XXXXXXX MagCharge Plate T-MP03 DC12V/1A 5W XXXXXXXX FCC ID XXXXXXX MagCharge Plate PH06 PRO DC12V/1A 5W MagCharge Plate無線充電模組 / PH06 PRO

Attestation Statements

TAKEWAY Ehoma Industrial Corporation To: Federal Communications Commission 7 435 Oakland Mills Road Columbia, MD 21046 USA Date: 12 March 2026 Attestation S ecti on 2.911 (d)(5)( i ) and Section 2.911 (d)(5)( ii ) ( KDB 9 86446 D0 1 C overe d Equipment ) Se ction 2.911 ( d)(5)( i ) Ehoma Industrial Corporation ("the applicant") certifies that the equipment for which authorization is sought is not "covered" equipment prohibited from receiving an equipment aut horization pursuant to section 2.903 of the FCC rules. Section 2. 911 ( d )(5)( ii) Ehoma Industrial Corporation ("the applicant") certifies that, as of t he date of the f iling of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its sub sidiaries or affiliates) as an entity producing "covered" equipment. Type of Equipment subject to FCC Certification: MagCharge Plate Wireless Charging Module F CC ID:2BUIVTKW26001 If you have any questions, pl ease feel free to contact me Contact Person: Hsinyi Chen Position in the Company: Preident Date of Signature: 12 March 2026 cu 召�. J-{ Jill惇 Signatory (signature of the applicant)

Attestation Statements

TAKEWAY Ehoma Industrial Corporation To: Federal Communications Commission 7 435 Oakland Mills Road Columbia, MD 21046 USA Date: 12 March 2026 Attestation Certif ication designating a U.S. Agent for Service of Process Section 2.911 ( d )(7) ( KDB 986446 D01 Covered Equipment ) Ehoma Industrial Corporation ("the applicant") as required by section 2.911 (d)( 7), d esignate below contact located in the United States for purposes of acting as the applicant's agent for service of process. The applicant also acceptance to maintain an agent for no less than one year after the grantee has terminated all marketing a nd importation or the conclusion of any Commission­related proceeding involving the equipment. Type of Equipment subject to FCC Certification: FCC ID: 2BUIVTKW26001 Sincerely yours, , Applicant/Grantee FRN: 0038095923 〔廎《' 兀N笮 (Signature) Ehoma Industrial Corporation Hsinyi Chen President [email protected] No.17,Kuochung 2nd Rd., Tali Dist., Taichung City,Taiwan US Agent FRN: 0033402884 (Signature) FCC US A gent, LLC T im Payne CEO [email protected] 3722 Illinois Avenue Saint Charles ILL/NO/S 6017 4 USA MagCharge Plate Wireless Charging Module

External Photos

Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 1 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 2 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 3 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 4 of 12

ID Label/Location Info

一心', MADE IN TAIWAN 產品名稱:MagCharge Plate無線充電模組 齶蝨霎 12V/1A CE�@ 0 閭認 輸 出功率:5W �XXXXXXXX FCC ID:2BUIVTKW26001 7罕�� MADE IN TAIWAN 產品名稱: MagCharge Plate 無線充電模組 型號:PH06 PRO CE�@ 。1i 認 輸入電壓: OC12V/1A 輸出功率:5W («XXXXXXXX FCC ID:2BUIVTKW26001 Label Loctaion

Internal Photos

Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 5 of 12 Antenna Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 6 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 7 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 8 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 9 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 10 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 11 of 12 Appendix No.: EP-2509T065-1 APPENDIX-EUT PHOTOS Project No.: 2509T065 Page 12 of 12

RF Exposure Info

Report No.: BTL-FCCP-2-2509T065 Project No.: 2509T065 Page 1 of 10 Report Version: R00 Human Exposure Report FCC ID: 2BUIVTKW26001 Report No. : BTL-FCCP-2-2509T065 Equipment : MagCharge Plate Wireless Charging Module Model Name : T-MP03, PH06 PRO Brand Name : TAKEWAY Applicant : Ehoma Industrial Corporation Address : No.17,Kuochung 2nd Rd., Tali Dist.,Taichung City,Taiwan Standard(s) : 47 CFR § 1.1310 Date of Receipt : 2025/9/16 Date of Test : 2025/12/16 Issued Date : 2026/3/11 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-2-2509T065 Project No.: 2509T065 Page 2 of 10 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-2-2509T065 Project No.: 2509T065 Page 3 of 10 Report Version: R00 CONTENTS REVISION HISTORY 4 1 GENERAL INFORMATION 5 1.1 TEST FACILITY 5 1.2 REFERENCE TEST GUIDANCE 5 1.3 TEST ENVIRONMENT CONDITIONS 5 2 TEST RESULTS 6 2.1 LIMITS 6 2.2 MEASUREMENT DATA 7 3 LIST OF MEASURING EQUIPMENTS 7 4 EUT TEST PHOTO 8 Report No.: BTL-FCCP-2-2509T065 Project No.: 2509T065 Page 4 of 10 Report Version: R00 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-2-2509T065 R00 Original Report. 2026/3/11 Valid Report No.: BTL-FCCP-2-2509T065 Project No.: 2509T065 Page 5 of 10 Report Version: R00 1 GENERAL INFORMATION 1.1 TEST FACILITY The test locations stated below are under the TAF Accreditation Number 0659. The test location(s) used to collect the test data in this report are: No. 68-1, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (FCC DN: TW0659) ☒ SAR01 ☐ SAR02 1.2 REFERENCE TEST GUIDANCE KDB680106 D01 Wireless Power Transfer v04 1.3 TEST ENVIRONMENT CONDITIONS Environment Condition Tested by 21.6 °C, 51 % Jimmy Gao Report No.: BTL-FCCP-2-2509T065 Project No.: 2509T065 Page 6 of 10 Report Version: R00 2 TEST RESULTS 2.1 LIMITS For 47 CFR PART 1, Subpart I, Section 1.1310: Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (m/W/cm 2 ) Averaging time (minutes) (A) Limits for Occupational / Controlled Exposures 0.3-3.0 614 1.63 *(100) 6 3.0-30 1842/f 4.89/f *(900/f 2 ) 6 30-300 61.4 0.163 1.0 6 300-1500 / / f/300 6 1500-100000 / / 5 6 (B) Limits for General Population / Uncontrolled Exposures 0.3-1.34 614 1.63 *(100) 30 1.34-30 824/f 2.19/f *(180/f 2 ) 30 30-300 27.5 0.073 0.2 30 300-1500 / / f/1500 30 1500-100000 / / 1.0 30 F=frequency in MHz *=Plane-wave equivalent power density RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310 (use the 300kHz limits for 150kHz: 614V/m, 1.63A/m). For KDB680106 D01: For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Report No.: BTL-FCCP-2-2509T065 Project No.: 2509T065 Page 7 of 10 Report Version: R00 2.2 MEASUREMENT DATA Electric Field Emissions: Test Position(20 cm) Probe Measure Results (V/m) Limit (V/m) intermediate charge Front 4.50 614 Back 4.72 614 Left 4.34 614 Right 4.45 614 Top 4.24 614 Bottom 4.68 614 Note:The maximum Probe Measure Results of this EUT is 4.72 V/m, less than 307 V/m(614 *50%). Magnetic Field Emissions: Test Position(20 cm) Probe Measure Results (A/m) Limit (A/m) intermediate charge Front 0.22 1.63 Back 0…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-1-2509T065 Project No.: 2509T065 Page 1 of 23 Report Version: R01 FCC Radio Test Report FCC ID: 2BUIVTKW26001 Report No. : BTL-FCCP-1-2509T065 Equipment : MagCharge Plate Wireless Charging Module Model Name : T-MP03, PH06 PRO Brand Name : TAKEWAY Applicant : Ehoma Industrial Corporation Address : No.17,Kuochung 2nd Rd., Tali Dist.,Taichung City,Taiwan Radio Function : WPC-Qi (110.5~205 kHz) FCC Rule Part(s) : FCC CFR Title 47, Part 15, Subpart C (15.209) Measurement Procedure(s) : ANSI C63.10-2020 Date of Receipt : 2025/9/16 Date of Test : 2025/12/10~ 2026/1/21 Issued Date : 2026/3/31 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Brett Shen, Engineer Approved by : Jerry Chuang, Vice Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Service mail: [email protected] Report No.: BTL-FCCP-1-2509T065 Project No.: 2509T065 Page 2 of 23 Report Version: R01 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL assumes no responsibility for the data provided by the Customer, any statements, inferences or generalizations drawn by the customer or others from the reports issued by BTL. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-2509T065 Project No.: 2509T065 Page 3 of 23 Report Version: R01 CONTENTS REVISION HISTORY 4 1 SUMMARY OF TEST RESULTS 5 1.1 TEST FACILITY 6 1.2 MEASUREMENT UNCERTAINTY 6 1.3 TEST ENVIRONMENT CONDITIONS 6 2 GENERAL INFORMATION 7 2.1 DESCRIPTION OF EUT 7 2.2 TEST MODES 7 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 2.4 SUPPORT UNITS 8 3 RADIATED EMISSIONS TEST 9 3.1 LIMIT 9 3.2 TEST PROCEDURE 9 3.3 DEVIATION FROM TEST STANDARD 9 3.4 TEST SETUP 10 3.5 EUT OPERATING CONDITIONS 11 3.6 TEST RESULT – 9 KHZ TO 30 MHZ 11 3.7 TEST RESULT – 30 MHZ TO 1 GHZ 11 4 20 DB BANDWIDTH 12 4.1 LIMIT 12 4.2 TEST PROCEDURE 12 4.3 DEVIATION FROM TEST STANDARD 12 4.4 TEST SETUP 12 4.5 EUT OPERATING CONDITIONS 12 4.6 TEST RESULT 12 5 LIST OF MEASURING EQUIPMENTS 13 6 EUT TEST PHOTO 13 7 EUT PHOTOS 13 APPENDIX A RADIATED EMISSIONS - 9 KHZ TO 30 MHZ 14 APPENDIX B RADIATED EMISSIONS - 30 MHZ TO 1 GHZ 19 APPENDIX C 20 DB BANDWIDTH 22 Report No.: BTL-FCCP-1-2509T065 Project No.: 2509T065 Page 4 of 23 Report Version: R01 REVISION HISTORY Report No. Version Description Issued Date Note BTL-FCCP-1-2509T065 R00 Original Report. 2026/3/11 Invalid BTL-FCCP-1-2509T065 R01 Revised Typo. 2026/3/31 Valid Report No.: BTL-FCCP-1-2509T065 Project No.: 2509T065 Page 5 of 23 Report Version: R01 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. Standard(s) Section Description Test Result Judgement Remark 15.207 AC Power Line Conducted Emissions ------ N/A NOTE (3) 15.209 Radiated Emissions APPENDIX A APPENDIX B Pass ------ 15.215(c) 20 dB Bandwidth APPENDIX C Pass ------ Statement of Conformity The statement of conformity is based on the binary decision rule according to IEC Guide 115 and ILAC G8 "simple acceptance" principle. Without considering measurement uncertainty, its specific risk is less than 50% PFA. (PFA: Probability of False Accept) NOTE: (1) ”N/A” denotes test is not applicable in this Test Report. (2) The report format version is TP.1.1.1. (3) This is a DC input device. Report No.: BTL-FCCP-1-2509T065 Project No.: 2509T065 Page 6 of 23 Report Version: R01 1.1 TEST FACILITY The test locations stated below are under the TAF Accreditation Number 0659. The test location(s) used to collect the test data in this report are: No. 68-1, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (FCC DN: TW0659) ☐ C05 ☐ CB08 ☐ CB11 ☐ SR10 ☒ SR11 No. 72, Ln. 169, Sec. 2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan (FCC DN: TW0659) ☐ C06 ☒ CB21 ☐ CB22 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expanded uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k = 2, providing a level of confidence of approximately 95 %. A. Radiated emissions test: Test Site Measurement Frequency Range (GHz) U (dB) CB21 (3m) 0.03~0.2 4.35 0.2~1 4.78 1 ~ 6 5.45 6 ~ 18 5.04 18 ~ 26 4.03 26 ~ 40 4.33 C. Conducted test : Test Item U Occupied Bandwidth 0.83 % NOTE: Unless specifically mentioned, the uncertainty of measurement has not been taken into account to de…

Text truncated - open the document above for the full version.

Test Report

深 发行 2023 深圳市 客 客 产 产 承认 行日期 3-06-27 市深 客户名 客户料 产品名 产品料 认后请签回 文件编 SLY-ZH 深联宇 承 称: 号: 称: 号: 客 回 , 如下订单 编号 X-29 宇电 承认书 TX SLY G4 客户承认 后未签回, 电子有 书 X线圈 41D5-6R9 认 视作默认 编制 陈美玲 有限 9-L15 认,谢谢您的 审核 陈展 限公 的合作 核 批 展良 赖 司 批准 伟 深圳市深联宇电子有限公司 文件编号 SLY-ZHX-29 发行日期 2023-06-27 版次 A 生效日期 2023-06-27 HD-系列 样品承认书 修订次数 0 页 码 1 /2 版本 更 改 履 历 更改人 更改时间 A 新发行:2023年05月18 日 陈美玲 2023-05-18 C 深圳市深 H 外形尺寸: (单 电气特性: 电感量L 直流电阻 (DCR) Q值 材料: )磁片: G41.5 )铜线: 0.08* )绕线方式: 逆 深联宇电 HD-系列 样品 单位:mm) 6 5 5*10.5正面黑 105丝包线, 逆时针10圈 电子有限 品承认书 6.3uH±5% 52mΩ Max ≥70 黑膜, 最高耐温1 3 圈 限公司 30°C 文件编号 版次 修订次数 测试条件 测试条件 测试条件 SLY-ZH A 0 100KH 100KH 100KH 4. HX-29 发 生 页 z/1V 测 试 数字 z/1V z/1V 电性图: 发行日期 生效日期 页 码 试仪器: 字电桥TH28 2023-06-27 2023-06-27 2 /2 17C+

Test Setup Photos

Appendix No.: TP-2509T065-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2509T065 Page 1 of 2 Radiated emissions test photos 9 kHz to 30 MHz Appendix No.: TP-2509T065-FCCP-1 APPENDIX-TEST PHOTOS Project No.: 2509T065 Page 2 of 2 Radiated emissions test photos 30 MHz to 1 GHz

Contact Information

Applicant

HsinYi Chen
[email protected]Fax: +886-4-24060584

Technical Contact

FCC US Agent, LLCTim Payne
[email protected]

3722 Illinois Avenue · Saint Charles, Illinois, 60174 · United States

Test Firm

BTL Inc.Jackie Chiu
[email protected]Fax: +886-2-2641-8698

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1105 MHz - 0.205 MHz-
Confidentiality
Long Term
Grant Notes
This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with the transmitter operating conditions for satisfying RF exposure compliance.