Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ProMeter PMT-0001 Bluetooth Pressure Gauge Build for manual coffee marker or E61 machine or others, monitoring real-time pressure. Provides incredible brewing experience with connect to ProMeter App. Features: 1. 2 build-in color theme (Dark and Light) and 5 display style, 4 display orientations for various display scenarios 2. Power saving settings especially battery mode (Brightness, Sleep mode etc.). Can be awake from specific pressure by setting wake up pressure. 3. Chart display Mode on PMT-0001 for Recording real-time brewing pressure curve,Start or reset chart by setting specific pressure value to triggered or manipulated on ProMeter app. Also PMT-0001 supports sending a User-defined reference pressure curve to reference while brewing espresso. 4. PMT-0001 supports connect to Bluetooth Scale for displaying real-time espresso weight on screen (Bluetooth Scale like Felicita, acaia, etc.) 6. Supports OTA upgrade firmware. Specifications: • 1.39-inch circular TFT screen with 360*360 resolution. • Power supply: Type-C or 16340 chargeable 3.7v lithium battery (battery not included). When powered by Type-C, it can charge the internal 16340 lithium battery (when the pressure gauge switch is turned on). • Case material: Nylon, specific material depends on the production batch. • Sensor operating temperature range: -20~100°C (for temperatures above 100°C, please use an appropriate extension interface before the threaded connection). • Sensor main body material: 304 stainless steel. • Installation thread: G1/8 (for other installation threads, such as G1/4, G1/8, M6, please contact customer service or use an adapter). • Maximum range: 16 Bar (range can be customized for an additional fee). • Measurable medium: Water. • Can be used with the ProMeter App. • Bluetooth mode: BLE5.0 (Low Energy). • Battery life: 1200mAh > 180 minutes (at medium brightness, for reference only, actual values depend on the usage environment). • Dimensions: o Length: 63mm, Width: 58mm, Height: 37mm, Weight: approx. 72g (excluding battery). o *Dimensions may vary due to subsequent component size changes, please confirm with customer service. Packaging Specifications: • Sensor body *1, Food-grade silicone sealing ring *2. App Download: • iOS: Search for ProMeter on the App Store. • Android: Contact customer service or visit the official website: http://prometer.cn. Installation Instructions: 1. Unscrew the back cover, insert the 16340 chargeable 3.7v lithium battery ensuring correct polarity (spring side connects to the negative terminal), then screw the back cover on tightly. 2. Check if the threaded port has an O-ring seal and if the seal is intact. If the seal is damaged or incomplete, replace it immediately. 3. Wrap the threaded port with an appropriate amount of PTFE tape (high-temperature resistant PTFE tape is recommended) to ensure adequate sealing so the screen can be properly oriented for display. 4. Using Flair 58 as an example, unscrew and remove the original pressure gauge, then screw in this product, tightening it adequately to ensure no water leakage during extraction operations. FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Jiangmen Pumite Technology Co., Ltd. Room D502, 5th Floor, Zhengping Technology Building, No. 24 Jianghui Road, Pengjiang District, Jiangmen City, Guangdong Province, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/01/21 U.S. Agent Designation Jiangmen Pumite Technology Co., Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BUJP-PMT-0001): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of Jiangmen Pumite Technology Co., Ltd. Jiangmen Pumite Technology Co., Ltd. with the FRN [0037906252] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature Guoting Zheng Manager Jiangmen Pumite Technology Co., Ltd. Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID: 2BUJP-PMT-0001 External Photos of the EUT FCC ID: 2BUJP-PMT-0001 FCC ID: 2BUJP-PMT-0001
Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BUJP-PMT-0001
FCC ID: 2BUJP-PMT-0001 Internal Photos of the EUT BLE ANT FCC ID: 2BUJP-PMT-0001 FCC ID: 2BUJP-PMT-0001
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure MPE Report Reference No. .................... : FCC ID. ........................................... : CTA26010601002 2BUJP-PMT-0001 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jan. 14, 2026 Testing Laboratory Name ............. : Shenzhen CTA Testing Technology Co., Ltd. Address ........................................... : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Jiangmen Pumite Technology Co., Ltd. Address ........................................... : Room D502, 5th Floor, Zhengping Technology Building, No. 24 Jianghui Road, Pengjiang District, Jiangmen City, Guangdong Province, China Standard .......................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : PMT-0001 Bluetooth Pressure Gauge Trade Mark....................................... : N/A Manufacturer .................................... : Jiangmen Pumite Technology Co., Ltd. Model/Type reference ...................... : PMT-0001 Listed Models ................................... : Refer to page 2 Rating ............................................... : DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA26010601002 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : PMT-0001 Bluetooth Pressure Gauge Model /Type : PMT-0001 Listed Models : PMT-0002, PMT-0003, PMT-0004, PMT-0005, PMT-0006, PMT-0007, PMT-0008, PMT-0009, PMT-0010 Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and colour is different for these model. Applicant : Jiangmen Pumite Technology Co., Ltd. Address : Room D502, 5th Floor, Zhengping Technology Building, No. 24 Jianghui Road, Pengjiang District, Jiangmen City, Guangdong Province, China Manufacturer : Jiangmen Pumite Technology Co., Ltd. Address : Room D502, 5th Floor, Zhengping Technology Building, No. 24 Jianghui Road, Pengjiang District, Jiangmen City, Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26010601002 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 MPE Calculation Method ......................................................................................... 7 4.3 Conducted Power Results ....................................................................................... 7 4.4 Manufacturing tolerance .......................................................................................... 8 4.5 Standalone MPE Result ........................................................................................... 8 4.6 Simultaneous Transmission for MPE Result ....................…
Text truncated - open the document above for the full version.
- 1 - SPECIFICATION FOR APPROVAL CUSTOMER:Shenzhen Seeed Technology Co., Ltd CUSTOMER PARTNO: CUSTOMER SIGNATURE: CUSTOMER SEAL: SUPPLIER SIGNATURE: SUPPLIER SEAL: NOTE: PLEASE RETURN THIS COPY AS A CERTIFICATION OF YOUR APPROVAL Prepared by:Dong Date: 2022.06.13 Add: Room 405, building R3-A, South District, Nanshan Science Park, Shenzhen Tel: 0755-86503881 Fax: 0755-27801677 Manufacturer:ShenZhen MyAntenna RF Technology Co.,Ltd PRODUCT MODEL:Seeed XIAO ESP32C3 PRODUCT NAME:Seeed XIAO ESP32C3 2.4G Antenna PRODUCT CODE:M01-0600890R0A 318020748 - 2 - VERSION INFORMATION Version DATE REVISION DESCRIPTION PREPARED CHECKED APPROVED A 2022.05.13 First edition release Dong Chen Yang B 2022.06.06 Add information such as packaging Dong Chen Yang C 2022.06.13 Change FPC Dong Chen Yang - 3 - PERFORMANCE PARAMETER 1. Electrical Characteristics 1 Frequency Range 2400MHz-2500MHz 2 V.S.W.R ≤2.0 3 Gain 2.90dBi 4 Efficiency 70.5% 5 Impendence 50Ω 6 Polarization mode Vertical 7 Interface type IPEX connect 2. Mechanical parameters 1 Measure FPC:40*20mm Cable: 1.13*80.0mm 2 Color BLACK 3. Environment Condition 1 Working Temp -30°C~80°C - 4 - TESTING CURVE 1. Performance test 1.1 V.S.W.R Data list Freq 2.4GHz 2.45GHz 2.5GHz VSWR 1.52 1.23 1.47 - 5 - TESTING CURVE 2. Passive testing 2.1 Efficiency and Gain - 6 - TEST DATA Efficiency and Gain Data list Freq Gain Efficiency 2400 2.43 61.81 2410 2.80 67.31 2420 2.68 67.79 2430 2.63 66.72 2440 2.44 64.60 2450 2.26 63.60 2460 2.54 66.24 2470 2.77 69.69 2480 2.81 69.96 2490 2.84 69.81 2500 2.90 70.51 - 7 - TEST CURVE 2.2 3D Map 2.3 2D Figure - 10 -
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA26010601001 2BUJP-PMT-0001 Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Jan. 14, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ..........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Jiangmen Pumite Technology Co., Ltd. Address ...........................................: Room D502, 5th Floor, Zhengping Technology Building, No. 24 Jianghui Road, Pengjiang District, Jiangmen City, Guangdong Province, China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : PMT-0001 Bluetooth Pressure Gauge Trade Mark ......................................: N/A Manufacturer ...................................: Jiangmen Pumite Technology Co., Ltd. Model/Type reference .....................: PMT-0001 Listed Models ..................................: Refer to page 2 Modulation ......................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: DC 5.0V From external circuit Result ..............................................: PASS Report No.: CTA26010601001 Page 2 of 38 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : PMT-0001 Bluetooth Pressure Gauge Model /Type : PMT-0001 Listed Models : PMT-0002, PMT-0003, PMT-0004, PMT-0005, PMT-0006, PMT-0007, PMT-0008, PMT-0009, PMT-0010 Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and colour is different for these model. Applicant : Jiangmen Pumite Technology Co., Ltd. Address : Room D502, 5th Floor, Zhengping Technology Building, No. 24 Jianghui Road, Pengjiang District, Jiangmen City, Guangdong Province, China Manufacturer : Jiangmen Pumite Technology Co., Ltd. Address : Room D502, 5th Floor, Zhengping Technology Building, No. 24 Jianghui Road, Pengjiang District, Jiangmen City, Guangdong Province, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26010601001 Page 3 of 38 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* .......................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 5 2.6 EUT operation mode ......................................................................................................................... 5 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory ........................................................................................................... 7 3.2 Test Faci…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BLE FCC ID : 2BUJP-PMT-0001 Company : Jiangmen Pumite Technology Co., Ltd. EUT : PMT-0001 Bluetooth Pressure Gauge Model Number : PMT-0001 Report No. : CTA26010601001 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result TestMode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.644 2401.692 2402.336 0.5 PASS 2440 0.640 2439.696 2440.336 0.5 PASS 2480 0.640 2479.688 2480.328 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0063 2401.5164 2402.5227 --- --- 2440 1.0082 2439.5191 2440.5273 --- --- 2480 1.0010 2479.5229 2480.5239 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result Peak TestMode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -3.45 ≤30 PASS 2440 -4.01 ≤30 PASS 2480 -4.30 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result TestMode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -19.25 ≤8.00 PASS 2440 -19.89 ≤8.00 PASS 2480 -20.14 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result TestMod e Antenn a ChNam e Freq(MHz ) RefLevel[dBm ] Result[dBm ] Limit[dBm ] Verdic t BLE_1M Ant1 Low 2402 -3.43 -57.46 ≤-23.43 PASS High 2480 -4.93 -56.12 ≤-24.93 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -5.01 -5.01 --- PASS 30~1000 -5.01 -67.46 ≤-25.01 PASS 1000~26500 -5.01 -48.68 ≤-25.01 PASS 2440 Reference -5.64 -5.64 --- PASS 30~1000 -5.64 -68.21 ≤-25.64 PASS 1000~26500 -5.64 -45.88 ≤-25.64 PASS 2480 Reference -5.10 -5.10 --- PASS 30~1000 -5.10 -68.41 ≤-25.1 PASS 1000~26500 -5.10 -47.09 ≤-25.1 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21 22 Appendix H: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -60.6 2.90 1.80 39.3 ≤54 PASS AV 2377.700 -58.79 2.90 1.80 41.11 ≤54 PASS AV 2390.000 -60.19 2.90 1.80 39.71 ≤54 PASS Peak 2310.000 -52.88 2.90 0.00 45.22 ≤74 PASS Peak 2385.890 -48.57 2.90 0.00 49.53 ≤74 PASS Peak 2390.000 -49.93 2.90 0.00 48.17 ≤74 PASS High 2480 AV 2483.500 -58.35 2.90 1.80 41.55 ≤54 PASS AV 2484.240 -58.12 2.90 1.80 41.78 ≤54 PASS AV 2500.000 -58.88 2.90 1.80 41.02 ≤54 PASS Peak 2483.500 -49.64 2.90 0.00 48.46 ≤74 PASS Peak 2484.720 -47.45 2.90 0.00 50.65 ≤74 PASS Peak 2500.000 -50.36 2.90 0.00 47.74 ≤74 PASS Note:The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 23 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV 24 BLE_1M_Ant1_High_2480_Peak
FCC ID: 2BUJP-PMT-0001 Test Setup Photos of the EUT FCC ID: 2BUJP-PMT-0001
19784 SUNKISSED RIDGE DR,RIVERSIDE, · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |