FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Foshan Fengqi Electronic Technology Co., Ltd./
  3. 2BUJY-0108127

2BUJY-0108127HUB remote control

Foshan Fengqi Electronic Technology Co., Ltd.
HUB remote control - FCC ID 2BUJY-0108127 - Foshan Fengqi Electronic Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Feb 04, 2026
Application Purpose
Original Equipment
Equipment Note
HUB remote control
Frequency Range
433.92000000 - 433.92000000
Company
Foshan Fengqi Electronic Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.

Attestation Statements

Attestation Statements Date: 2026-01-29 TO: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046, USA RE: Attestation Statements Part 2.911(d)(7) request for (FCC ID:2BUJY-0108127) Foshan Fengqi Electronic Technology Co., Ltd. the undersigned, hereby authorize HOPEK CORPORATION INC to act as our designated U.S. agent for service of process, Foshan Fengqi Electronic Technology Co., Ltd. accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. HOPEK CORPORATION INC accepts the responsibility to act as designated U.S. agent for service of process. Applicant Information: Company name: Foshan Fengqi Electronic Technology Co., Ltd. Contact Name: Guozhi Hu Address: 203, 2nd Floor, Building A, No. 4 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, China Telephone No: 13202396798 Email: [email protected] FRN: 0037906427 Signature: GuozhiHu U.S. Agent Information: Company Name:HOPEK CORPORATION INC Address:16755 Coyote Bush Dr Unit 84, San Diego, CA 92127 United States FRN:0034562900 Contact Name:Yangyang Xu Telephone No:561-875-9826 Email:[email protected] Signature: Peter Davis

External Photos

FCC ID: 2BUJY-0108127 External Photos of the EUT FCC ID: 2BUJY-0108127 FCC ID: 2BUJY-0108127

ID Label/Location Info

Label and Location Size: L: 1.0cm*W: 0.5cm Label and Location FCC ID : 2BUJY-0108127

Internal Photos

FCC ID: 2BUJY-0108127 Internal Photos of the EUT FCC ID: 2BUJY-0108127 433MHz ANT FCC ID: 2BUJY-0108127

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. .................... : FCC ID. ........................................... : CTA26012101802 2BUJY-0108127 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jan. 26, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ........................................... : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao‘an District, Shenzhen, China Applicant’s name ............................ : Foshan Fengqi Electronic Technology Co., Ltd. Address ........................................... : 203, 2nd Floor, Building A, No. 4 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : HUB remote control Trade Mark ........................................ N/A Manufacturer .................................... : Foshan Fengqi Electronic Technology Co., Ltd. Model/Type reference ...................... : 0108127 Listed Models .................................. : N/A Ratings ............................................. : DC 3.0V From battery Result ............................................... : PASS Report No.: CTA26012101802 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : HUB remote control Model /Type : 0108127 Listed Models : N/A Applicant : Foshan Fengqi Electronic Technology Co., Ltd. Address : 203, 2nd Floor, Building A, No. 4 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, China Manufacturer : Foshan Fengqi Electronic Technology Co., Ltd. Address : 203, 2nd Floor, Building A, No. 4 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26012101802 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 T E S T S T A N D A R D S ................................................... 4 2 S U M M A R Y .............................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Special Accessories 5 2.4 Modifications 5 3 T E S T E N V I R O N M E N T ................................................ 6 3.1 Address of the test laboratory 6 3.2 Test Facility 6 3.3 Statement of the measurement uncertainty 6 4 T E S T L I M I T ............................................................ 7 4.1 Requirement 7 4.2 Conducted Power Results 7 4.3 Manufacturing tolerance 8 4.4 Evaluation Result 8 4.5 Simultaneous Transmission for SAR Exclusion 8 5 C O N C L U S I O N .......................................................... 8 Report No.: CTA26012101802 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R D S The tests were performed according to following standards: ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB 447498 D01 General RF Exposure Guidance v06: Mobile and Portable Device, RF Exposure, Equipment Authorization Procedures. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1093: Radiofrequency radiation exposure evaluation: portable devices Report No.: CTA26012101802 Page 5 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Jan. 21, 2026 Testing commenced on : Jan. 21, 2026 Testing concluded on : Jan. 26, 2026 2.2 Product Description Product Description: HUB remote control Model/Type reference: 0108127 Power supply: DC 3.0V From battery Hardware version: V1.0 Software version: V1.0 Testing sample ID: CTA260121018-1# (Engineer sample), CTA260121018-2#(Normal sample) Modulation: ASK Operation frequency: 433.92MHz Channel number: 1 Antenna type: PCB antenna Antenna gain: 0.5 dBi 2.3 Special Accessories The following is the EUT test of the auxiliary …

Text truncated - open the document above for the full version.

Test Report

Antenna Specification PCB-LAYOUT antenna 1)antenna Antenna gain: 0.5dBi Antenna type: PCB-LAYOUT antenna Manufacturer:Foshan Fengqi Electronic Technology Co., Ltd. Address: 203, 2nd Floor, Building A, No. 4 Zhonghuan Road,Luocun, Shishan Town, Nanhai District, Foshan, China

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China FCC PART 15 SUBPART C TEST REPORT FCC PART 15.231 Report Reference No. .................... : FCC ID. ........................................... : CTA26012101801 2BUJY-0108127 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Jan. 26, 2026 Testing Laboratory Name ............. : Shenzhen CTA Testing Technology Co., Ltd. Address ........................................... : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Foshan Fengqi Electronic Technology Co., Ltd. Address ............................................ : 203, 2nd Floor, Building A, No. 4 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, China Test specification ........................... : Standard ........................................... : FCC Part 15.231 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : HUB remote control Trade Mark ....................................... : N/A Manufacturer .................................... : Foshan Fengqi Electronic Technology Co., Ltd. Model/Type reference ...................... : 0108127 Listed Models .................................. : N/A Modulation ....................................... : ASK Frequency ......................................... 433.92MHz Ratings ............................................. : DC 3.0V From battery Result ............................................... : PASS Report No.: CTA26012101801 Page 2 of 25 T E S T R E P O R T Equipment under Test : HUB remote control Model /Type : 0108127 Listed Models : N/A Applicant : Foshan Fengqi Electronic Technology Co., Ltd. Address : 203, 2nd Floor, Building A, No. 4 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, China Manufacturer : Foshan Fengqi Electronic Technology Co., Ltd. Address : 203, 2nd Floor, Building A, No. 4 Zhonghuan Road, Luocun, Shishan Town, Nanhai District, Foshan, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26012101801 Page 3 of 25 Contents 1 T E S T S T A N D A R D S .................................................................. 4 2 S U M M A R Y ............................................................................. 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT configuration 5 2.6 Block Diagram of Test Setup 6 2.7 Special Accessories 6 2.8 Related Submittal(s) / Grant (s) 6 2.9 Modifications 6 3 T E S T E N V I R O N M E N T ............................................................... 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Summary of measurement results 8 3.5 Statement of the measurement uncertainty 8 3.6 Equipments Used during the Test 8 4 T E S T C O N D I T I O N S A N D R E S U L T S ............................................ 10 4.1 AC Power Conducted Emission 10 4.2 Radiated Emission 11 4.3 20dB Bandwidth 17 4.4 Deactivation Time 18 4.5 Antenna Requirement 19 5 T E S T S E T U P P H O T O S O F T H E E U T .......................................... 20 6 P H O T O S O F T H E E U T ............................................................. 21 Report No.: CTA26012101801 Page 4 of 25 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.231:Periodic operation in the band 40.66-40.70 MHz and above 70 MHz. ANSI C63.10-2020+Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024: American National Standard for Testing Unlicensed Wireless Devices Report No.: CTA26012101801 Page 5 of 25 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Jan. 21, 2026 Testing commenced on : Jan. 21, 2026 Testing concluded on : Jan. 26, 2026 2.2 Product Description Product Name: HUB remote control Model/Type reference: 0108127 Power supply: DC 3.0V From battery Testing sample ID: CTA260121018-1# (Engineer sample), CTA260121018-2#(Normal sample) Modulation: ASK Operation frequency: 433.92MHz Channel number: 1 Antenna type: PCB antenna Antenna gain: 0.5 dBi 2.3 Equipment Under Test Power supply system utilised Power supply voltage : ○ 230V / 50 Hz ○ 120V / 60Hz ○ 12 V DC ○ 24 V DC ● Other (specified in blank below) DC 3.0V From battery 2.4 Short description of the Equipment under Test (EUT) This is a HUB remote control. For more details, refer to the user’s manual of the EUT. 2.5 EUT configuration The following peripheral devices and interface cables were connected during the measurement: ● - supplied by the manufacturer ○ - supplied by the lab Report No.: CTA26012101801 Page 6 of 25 2.6 Block Diagram of Test Setup 2.7 Special Accessories Follow auxiliary equipment(s) test with EUT that provided by the manufacturer or laboratory is listed as follow: Description Manufacturer Model Technical Parameters Certificate Provided by / / / / / / / / / / / / 2.8 Related Submittal(s) / Grant (s) This submittal(s) (test report) is intended for …

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2BUJY-0108127 Test Setup Photos of the EUT

Contact Information

Applicant

Guozhi Hu(Manager)
[email protected]Fax: 13202396798

Technical Contact

HOPEK CORPORATION INCYangyang Xu
[email protected]

16755 Coyote Bush Dr Unit 84 San Diego, · United States

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term