FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shenzhen IBD Intelligence Technology Co.,Ltd./
  3. 2BULG-KA-1

2BULG-KA-1Ka Liu

Shenzhen IBD Intelligence Technology Co.,Ltd.
Ka Liu - FCC ID 2BULG-KA-1 - Shenzhen IBD Intelligence Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 26, 2026
Application Purpose
Original Equipment
Equipment Note
Ka Liu
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen IBD Intelligence Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

POPMART SMART ACCESSORIE. MODEL:LA01 Countries where it can be issued. Global Certifications required for wireless electronic products in various countries. Charged productsUN38.3 3C、SRRC CE-RED Anatel UKCA IMDA NBTC EPR 注册 PSE、TELEC GCC/SASO/ECAS BIS/TEC/WPC SDPPI ICASA NTC MIC TRA RCM RCM IC FCC KC Germany / France China America European Union South Korea Japan Middle East Brazil United Kingdom India Indonesia Vietnam Thailand South Africa New Zealand Canada Philippines Singapore United Arab Emirates Australia Certificate model: Quality inspector: production date: Warning FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.

Attestation Statements

Shenzhen IBD Intelligence Technology Co.,Ltd. 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/01/23 U.S. Agent Designation Shenzhen IBD Intelligence Technology Co.,Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BULG-KA-1): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of Shenzhen IBD Intelligence Technology Co.,Ltd. Shenzhen IBD Intelligence Technology Co.,Ltd. with the FRN [0037915162] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature jinyan li Manager Shenzhen IBD Intelligence Technology Co.,Ltd. Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5

External Photos

FCC ID: 2BULG-KA-1 External Photos of the EUT FCC ID: 2BULG-KA-1 FCC ID: 2BULG-KA-1

ID Label/Location Info

Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BULG-KA-1

Internal Photos

FCC ID: 2BULG-KA-1 Internal Photos of the EUT FCC ID: 2BULG-KA-1 BLE ANT FCC ID: 2BULG-KA-1

RF Exposure Info

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. ..................... : FCC ID. ........................................... : CTA25121902402 2BULG-KA-1 Compiled by ( position+printed name+signature) .. : File administrators Zoey Cao Supervised by ( position+printed name+signature) .. : Project Engineer Ace Chai Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Dec. 27, 2025 Testing Laboratory Name ............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ........................... : Shenzhen IBD Intelligence Technology Co.,Ltd. Address ............................................ : 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen , China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : Ka Liu Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen IBD Intelligence Technology Co.,Ltd. Model/Type reference ....................... : KA-1 Listed Models ................................... : N/A Ratings .............................................. : DC 3.7V From battery and DC 5.0V From external circuit Result ................................................ : PASS Report No.: CTA25121902402 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Ka Liu Model /Type : KA-1 Listed Models : N/A Applicant : Shenzhen IBD Intelligence Technology Co.,Ltd. Address : 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen , China Manufacturer : Shenzhen IBD Intelligence Technology Co.,Ltd. Address : 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen , China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25121902402 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 Conducted Power Results ....................................................................................... 7 4.3 Manufacturing tolerance .......................................................................................... 7 4.4 Evaluation Result ..................................................................................................... 8 4.5 Simultaneous Transmission for SAR Exclusion ...................................................... 8 5 Conclusion ........................................................................................................................... 8 Report No.: CTA25121902402 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:c…

Text truncated - open the document above for the full version.

Test Report

1. Antenna Description: Antenna type Ceramic antenna Model KA-1 Frequency range 2400-2500MHz Manufacturer Shenzhen IBD Intelligence Technology Co.,Ltd. Address 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen, China ANT Peak Gain 2 dBi 2. Antenna Photo: 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz

Test Report

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA25121902401 2BULG-KA-1 Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Dec. 27, 2025 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ..........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Shenzhen IBD Intelligence Technology Co.,Ltd. Address ...........................................: 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen, China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : Ka Liu Trade Mark ......................................: N/A Manufacturer ...................................: Shenzhen IBD Intelligence Technology Co.,Ltd. Model/Type reference .....................: KA-1 Listed Models ..................................: N/A Modulation ......................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: DC 3.7V From battery and DC 5.0V From external circuit Result ..............................................: PASS Report No.: CTA25121902401 Page 2 of 32 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Ka Liu Model /Type : KA-1 Listed Models : N/A Applicant : Shenzhen IBD Intelligence Technology Co.,Ltd. Address : 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen, China Manufacturer : Shenzhen IBD Intelligence Technology Co.,Ltd. Address : 2nd Floor, Building 2, Dexin Chang Wisdom Park, No. 23 Heping Road, Longhua Street, Longhua District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25121902401 Page 3 of 32 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS .......................................................................................................................................... 4 2 SUMMARY ........................................................................................................................................................ 5 2.1 General Remarks .................................................................................................................................... 5 2.2 Product Description* ................................................................................................................................ 5 2.3 Equipment Under Test ............................................................................................................................ 5 2.4 Short description of the Equipment under Test (EUT) ............................................................................ 5 2.5 EUT configuration .................................................................................................................................... 5 2.6 EUT operation mode ............................................................................................................................... 5 2.7 Block Diagram of Test Setup .................................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) .............................................................................................................. 6 2.9 Modifications ........................................................................................................................................... 6 3 TEST ENVIRONMENT ...................................................................................................................................... 7 3.1 Address of the test laboratory ................................................................................................................. 7 3.2 Test Facility ............................................................................................................................................. 7 3.3 Environmental conditions ................................................................…

Text truncated - open the document above for the full version.

Test Report

1 FCC Appendix RF Test Data for BLE FCC ID : 2BULG-KA-1 Company : Shenzhen IBD Intelligence Technology Co.,Ltd. EUT : Ka Liu Model Number : KA-1 Report No. : CTA25121902401 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result TestMode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.656 2401.684 2402.340 0.5 PASS 2440 0.640 2439.696 2440.336 0.5 PASS 2480 0.656 2479.692 2480.348 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0024 2401.5201 2402.5225 --- --- 2440 1.0033 2439.5180 2440.5213 --- --- 2480 1.0041 2479.5200 2480.5241 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result Peak TestMode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -0.02 ≤30 PASS 2440 -0.37 ≤30 PASS 2480 -0.37 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result TestMode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -15.71 ≤8.00 PASS 2440 -15.68 ≤8.00 PASS 2480 -16.10 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result TestMod e Antenn a ChNam e Freq(MHz ) RefLevel[dBm ] Result[dBm ] Limit[dBm ] Verdic t BLE_1M Ant1 Low 2402 -0.29 -49.49 ≤-20.29 PASS High 2480 -0.72 -54.12 ≤-20.72 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -0.49 -0.49 --- PASS 30~1000 -0.49 -67.8 ≤-20.49 PASS 1000~26500 -0.49 -43.94 ≤-20.49 PASS 2440 Reference -1.72 -1.72 --- PASS 30~1000 -1.72 -68.48 ≤-21.72 PASS 1000~26500 -1.72 -41.82 ≤-21.72 PASS 2480 Reference -1.41 -1.41 --- PASS 30~1000 -1.41 -67.57 ≤-21.41 PASS 1000~26500 -1.41 -44.93 ≤-21.41 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21

Test Setup Photos

FCC ID: 2BULG-KA-1 Test Setup Photos of the EUT FCC ID: 2BULG-KA-1

Contact Information

Applicant

jinyan li
[email protected]Fax: /

Technical Contact

GLOCERTS TECHNOLOGY INCHuiying Fan
[email protected]

19784 SUNKISSED RIDGE DR,RIVERSIDE, · United States

Test Firm

SHENZHEN CTA TESTING TECHNOLOGY CO., LTD.Eric Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted.