Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Vibe Flex Bone Conduction HEARING AMPLIFIER User Manual For assistance or additional information, please contact us at: [email protected] Model No.: D20B Read Before Use ............................................................................................. Box Contents .................................................................................................... Product Overview ........................................................................................... Charging Instructions .................................................................................... Charging the Hearing Amplifier ............................................................... How to Wear the Hearing Amplifier ........................................................ Operation Guides ............................................................................................ Bluetooth Connection .................................................................................. Hearing Ampilification & Bluetooth Streaming ................................... Bluetooth Streaming & Call Control ......................................................... Troubleshooting .............................................................................................. Maintenance & Care ....................................................................................... FCC Regulatory Compliance ....................................................................... Disposal & Recycling ...................................................................................... Specifications ................................................................................................... Warranty ............................................................................................................. 1,2 3 4 5 5 6 7 8 9 10 11 12 13 14 14 15,16 Table of Contents - 1 - Do not use this device if any of the following conditions apply: •Open wounds, skin infections, or inflammation at or near the intended placement area on the head. Use of the device may aggravate the condition or delay healing. •Known or suspected skull defects or abnormalities in bone structure (e.g., after cranial surgery or with congenital bone conditions). Consult with a medical professional before use. •Persistent or unexplained dizziness, vertigo, or balance disorders. The vibrations of bone conduction may worsen these symptoms. •Severe mixed or profound sensorineural hearing loss. Bone conduction hearing amplifier is generally not effective for these conditions. •Allergic reaction to materials in the device or headband (e.g., silicone, plastic, or metal components). •Children under 18 years old unless directed by a healthcare provider. Young children may be more sensitive to vibration or improper fit. •Implanted medical devices such as pacemakers or neurostimulators. While bone conduction amplifier typically do not interfere, consult your physician to rule out potential interference. Read Before Use •Exposure to high temperature, high humidity, strong magnetic fields (>0.1T/MRI), X-rays, and mechanical stress can damage the hearing amplifier. •Do not place the hearing amplifier in an environment with high temperature or high humidity. Do not use the hearing amplifier while bathing, washing your face, shaving or putting on makeup. Do not place the hearing amplifier in a microwave oven. •Do not press the hearing amplifier buttons too hard to avoid damage. •Do not dispose of used hearing amplifier improperly. If you need to dispose of them, please follow the relevant national regulations. Safety Instructions - 2 - - 3 - Box Contents 1. Hearing Amplifier2. Charging Cable 12 - 4 - Product Overview Hearing Amplification On/Off Switch Volume Button Hearing Mode Button Charging Port Left/Right Volume Switch Microphone Power Button Battery Indicator Multifunction Button - 5 - To ensure optimal battery life and reliable performance, please follow these steps to charge the hearing amplifier. Introductions Charging Instructions Battery level: >75% Battery level: 50%~75% Battery level: 25%~50% Battery level: 15%~25% Battery is low. Checking Battery Level When the hearing amplifier is powered on, click the power button once to illuminate the battery indicator and get to know the current battery level: Charging the Hearing Aids When the hearing amplifier battery level drops below 20%, the battery indicator lights will flash and the speaker will issue a voice prompt to alert you. 1. Connect the hearing amplifier to a USB-C power source (power adapter is not included). 2. Charging Indicator Lights • Flashing: Charging in progress • Stay Solid: Fully charged. 3. Charging Time: It typically takes 1.5 hours to fully charge the hearing ampilifier. Position the Device on Your Head: Place the transducer pad just in front of your ear, on the cheekbone or temporal bone. Ensure the pad sits firmly against the bone, not on soft tissue or the ear canal. Wear Glasses with Care (if applicable): If you wear glasses, put the hearing amplifier on after your glasses to prevent interference with placement. - 6 - Introductions How to Wear the Hearing Amplifier - 7 - Power ON •Hold the power button for 3 seoncds as the battery indicator flashes. Power OFF •Hold the power button for 3 seoncds. Volume Adjustment The left and right hearing amplifier volume can be adjusted separately, each supports 5 volume levels. •Slide the volume switch to the side that the volume needs to be adjusted. •Press the volume buttons to increase or decrease the volume, you will hear Maximum Volume voice prompt when it reaches to max volume, and Minimum Volume voice prompt when it reaches minimum volume. Hearing Mode Switch Slide the hearing mode button to set it to indoor mode, outdoor mode and conversation mode. •Indoor Mode: Optimized for quiet environments like home, offices, or libraries. Enhances speech clarity while reducing low-level background noise. •Outdoor Mode: Desi…
Text truncated - open the document above for the full version.
Shenzhen Hongyu Health Technology Co., Ltd. 2/F, Building 2A, Taihua Wutong Industrial Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/01/30 U.S. Agent Designation Shenzhen Hongyu Health Technology Co., Ltd. acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BUP7-D20B): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of Shenzhen Hongyu Health Technology Co., Ltd. Shenzhen Hongyu Health Technology Co., Ltd. with the FRN [0037952561] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature Ray Li Manager Shenzhen Hongyu Health Technology Co., Ltd. Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID: 2BUP7-D20B External Photos of the EUT FCC ID: 2BUP7-D20B
Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BUP7-D20B
FCC ID: 2BUP7-D20B Internal Photos of the EUT FCC ID: 2BUP7-D20B FCC ID: 2BUP7-D20B FCC ID: 2BUP7-D20B BT ANT FCC ID: 2BUP7-D20B FCC ID: 2BUP7-D20B FCC ID: 2BUP7-D20B
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. ..................... : FCC ID. ............................................ : CTA25102200303 2BUP7-D20B Compiled by ( position+printed name+signature) .. : File administrators Zoey Cao Supervised by ( position+printed name+signature) .. : Project Engineer Ace Chai Approved by ( position+printed name+signature) .. : RF Manager Eric Wang Date of issue ..................................... : Jan. 19, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address ............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Shenzhen Hongyu Health Technology Co., Ltd. Address ............................................ : 2/F, Building 2A, Taihua Wutong Industrial Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Bone Conduction Hearing Amplifier Trade Mark ....................................... : Vitopdia Manufacturer .................................... : Shenzhen Hongyu Health Technology Co., Ltd. Model/Type reference ...................... : D20B Listed Models ................................... : Vibe Flex Rating ............................................... : DC 3.7V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA25102200303 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Bone Conduction Hearing Amplifier Model /Type : D20B Listed Models : Vibe Flex Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and colour is different for these model. Applicant : Shenzhen Hongyu Health Technology Co., Ltd. Address : 2/F, Building 2A, Taihua Wutong Industrial Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, China Manufacturer : Shenzhen Hongyu Health Technology Co., Ltd. Address : 2/F, Building 2A, Taihua Wutong Industrial Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25102200303 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 5 2.4 Modifications ............................................................................................................ 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory .................................................................................. 6 3.2 Test Facility .............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................. 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ............................................................................................................ 7 4.2 Conducted Power Results ....................................................................................... 7 4.3 Manufacturing tolerance .......................................................................................... 8 4.4 Evaluation Result ..................................................................................................... 8 4.5 Simultaneous Transmission for SAR Exclusion ...................................................... 8 5 Conclusion .......................................................................................................................…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BLE FCC ID : 2BUP7-D20B Company : Shenzhen Hongyu Health Technology Co., Ltd. EUT : Bone Conduction Hearing Amplifier Model Number : D20B Report No. : CTA25102200301 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result TestMode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.620 2401.696 2402.316 0.5 PASS 2440 0.660 2439.684 2440.344 0.5 PASS 2480 0.640 2479.696 2480.336 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0126 2401.5166 2402.5292 --- --- 2440 1.0075 2439.5177 2440.5252 --- --- 2480 1.0093 2479.5183 2480.5276 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result Peak TestMode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -3.36 ≤30 PASS 2440 -4.05 ≤30 PASS 2480 -4.44 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result TestMode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -19.26 ≤8.00 PASS 2440 -19.96 ≤8.00 PASS 2480 -20.55 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 -3.78 -53.65 ≤-23.78 PASS High 2480 -5.04 -57.14 ≤-25.04 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -5.92 -5.92 --- PASS 30~1000 -5.92 -67.88 ≤-25.92 PASS 1000~26500 -5.92 -44.91 ≤-25.92 PASS 2440 Reference -4.95 -4.95 --- PASS 30~1000 -4.95 -68.19 ≤-24.95 PASS 1000~26500 -4.95 -49.11 ≤-24.95 PASS 2480 Reference -5.88 -5.88 --- PASS 30~1000 -5.88 -67.84 ≤-25.88 PASS 1000~26500 -5.88 -46.61 ≤-25.88 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21 22 Appendix H: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m ] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -59.73 2.67 1.80 39.94 ≤54 PASS AV 2370.245 -58.68 2.67 1.80 40.99 ≤54 PASS AV 2390.000 -59.29 2.67 1.80 40.38 ≤54 PASS Peak 2310.000 -53.12 2.67 0.00 44.75 ≤74 PASS Peak 2385.785 -48.32 2.67 0.00 49.55 ≤74 PASS Peak 2390.000 -51.77 2.67 0.00 46.1 ≤74 PASS High 2480 AV 2483.500 -59.03 2.67 1.80 40.64 ≤54 PASS AV 2483.680 -58.27 2.67 1.80 41.4 ≤54 PASS AV 2500.000 -59.57 2.67 1.80 40.1 ≤54 PASS Peak 2483.500 -50.65 2.67 0.00 47.22 ≤74 PASS Peak 2483.840 -48.79 2.67 0.00 49.08 ≤74 PASS Peak 2500.000 -50.89 2.67 0.00 46.98 ≤74 PASS Note:The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 23 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV 24 BLE_1M_Ant1_High_2480_Peak
2.4GHz 3216 Chip Antenna: HT-3216-C07 _ Application: WLAN,802.11b/g,Bluetooth,WLAN,etc... Features SMD,highreliability,ultraImpact,Omni-directional... PartnumberInformation F245 C 07 HT (A)(B)(F)(E)(D)(C) Electrical Specification The specification is defined on EVB. Dimension and Terminal Configuration No.Terminal Name 1Feeding/GNG 2GND/Feeding Chip Antenna(A)Product Type (B) Size Code 3.2x1.6mm( ± 0.2mm) (C) MaterialHigh K material 2.4 ~ 2.5GHz(D) Frequency PIFA & Single Feeding(E) Feeding mode Type=0X(F) Antenna type Working Frequency Range2400 ~2500 MHz Bandwidth120 MHz (Min.) Peak Gain2.67 dBi (Typ.) Impedance50 Ohm Return loss10 dB ( Min) PolarizationLinear Azimuth BeamwidthOmni-directional Operation Temperature( °C )-40 ~85 °C Resistance to Soldering Heats 10sec. ( @ 280 °C ) TerminationNi / Au (Leadless) Dimension (mm) L 3.20 ± 0.20 W 1.60 ± 0.20 T 0.45 ± 0.20 電話: 18665849001 3216 深圳市合拓科技有限公司 Shenzhen Hetuo Technology Co.,Ltd. TEL: 18665934465 Add: Room 1202B, Building C6, Hengfeng Industrial City, No. 739 Zhoushi Road, Hezhou Community, Hangcheng Street, Bao'an District, Shenzhen 2.4GHz 3216 Chip Antenna: HT-3216-C07 _ 1 Evaluation BoardReference PCB DimensionAntenna Layout Reference Unit :mm Electrical Characteristics Return Loss & Radiation Return Loss Frequency(MHz) S11(dB) 2400-10.50 2450-30.62 2500-11.47 Radiation X Y Z 深圳市合拓科技有限公司 Shenzhen Hetuo Technology Co.,Ltd. 2.4GHz 3216 Chip Antenna: HT-3216-C07 _ Taping Specifications Reel and Taping Specification Reel Specification TYPESIZEABCD 32167” 5K/Reel 9.0±0.5 60±213.5±0.5178±2 Tapping Specification PackagingTypeABWEFGHTψDP Paper Type 3216 1.90±0.20 3.50±0.20 8.0±0.20 1.75±0.10 3.5±0.05 4.0±0.10 2.0±0.05 0.75±0.10 1.50±0.10 4.0±0.1 深圳市合拓科技有限公司 Shenzhen Hetuo Technology Co.,Ltd. 2.4GHz 3216 Chip Antenna: HT-3216-C07 _ Reliability Table Test ItemProcedure Requirements Ceramic Type Remark (Reference) Electrical Characterization Fulfill the electrical specification User Spec. Thermal Shock 1. Preconditioning: 50 ± 10°C/ 1 hr , then keep for 24 ± 1 hrs at room temp. 2. Initial measure: Spec: refer Initialspec. 3. Rapid change of temperature test: -30°Cto +85°C; 100 cycles; 15 minutes at Lower category temperature; 15 minutes at Upper category temperature. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 107 Temperature Cycling 1. Initial measure: Spec: refer Initialspec. 2. 100 Cycles (-30°Cto +85°C), Soak Mode=1 (2 Cycle/hours). 3. Measurement at 24 ± 2Hours after testcondition. No Visible Damage. Fulfill the electrical specification. JESD22 JA104 High Temperature Exposure 1. Initial measure: Spec: refer Initialspec. 2. Unpowered; 500hours @ T=+85°C. 3. Measurement at 24 ± 2 hours aftertest. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 108 Low Temperature Storage 1. Initial measure: Spec: refer Initialspec. 2. Unpowered: 500hours @ T=-30°C. 3. Measurement at 24 ± 2 hours aftertest. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 108 Solderability (SMD Bottom Side) Dipping method: a. Temperature: 235 ±5°C b. Dipping time: 3 ±0.5s The solder should cover over 95% of the critical area of bottom side. IEC 60384-21/22 4.10 Soldering Heat Resistance (RSH) Preheating temperature: 150 ± 10°C. Preheating time: 1~2 min. Solder temperature: 260 ± 5°C. Dipping time: 5 ± 0.5s No Visible Damage.IEC 60384-21/22 4.10 Vibration5g's for 20 min., 12 cycles each of 3 orientations Note: Use 8"X5" PCB .031" thick 7 secure points on, one long side and 2 secure points at corners of opposite sides. Parts mounted within 2" from any secure point. Test from 10-2000 Hz. No Visible Damage.MIL-STD-202 Method 204 Mechanical Shock Three shocks in each direction shall be applied along the three mutually perpendicular axes of the test specimen (18 shocks) Peak value: 1,500g’s Duration: 0.5ms Velocity change: 15.4 ft/s Waveform: Half-sine No Visible Damage.MIL-STD-202 Method 213 Humidity Bias 1. Humidity: 85% R.H., Temperature:85 ± 2 °C. 2. Time: 500 ± 24hours. 3. Measurement at 24 ± 2hrs after testcondition. No Visible Damage. Fulfill the electrical specification. MIL-STD-202 Method 106 深圳市合拓科技有限公司 Shenzhen Hetuo Technology Co.,Ltd. 2.4GHz 3216 Chip Antenna: HT-3216-C07 _ Board Flex (SMD) 1. Mounting method: IR-Reflow. PCB Size (L:100 × W:40 × T:1.6mm) 2. Apply the load in direction of the arrow until bending reaches 2 mm. No Visible Damage.AEC-Q200 005 AdhesionForce of 1.8Kg for 60 seconds.No Visible Damage Magnification of 20X or greater may be employed for inspection of the mechanical integrity of the device body terminals and body/terminal junction. AEC-Q200 006 Physical Dimension Any applicable method using x10 magnification, micrometers, calipers, gauges, contour projectors, or other measuring equipment, capable of determining the actual specimen dimensions. In accordance with specification. JESD22 JB100 Revision History RevisionDateContent 12019/03/01 New Datasheet 22020/02/22 Add 2D radiation characteristic 深圳市合拓科技有限公司 Shenzhen Hetuo Technology Co.,Ltd.
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA25102200301 2BUP7-D20B Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Jan. 19, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ..........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Shenzhen Hongyu Health Technology Co., Ltd. Address ...........................................: 2/F, Building 2A, Taihua Wutong Industrial Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : Bone Conduction Hearing Amplifier Trade Mark ......................................: Vitopdia Manufacturer ...................................: Shenzhen Hongyu Health Technology Co., Ltd. Model/Type reference .....................: D20B Listed Models ..................................: Vibe Flex Modulation ......................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: DC 3.7V From battery and DC 5.0V From external circuit Result ..............................................: PASS Report No.: CTA25102200301 Page 2 of 42 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Bone Conduction Hearing Amplifier Model /Type : D20B Listed Models : Vibe Flex Model difference : The PCB board, circuit, structure and internal of these models are the same, Only model number and colour is different for these model. Applicant : Shenzhen Hongyu Health Technology Co., Ltd. Address : 2/F, Building 2A, Taihua Wutong Industrial Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, China Manufacturer : Shenzhen Hongyu Health Technology Co., Ltd. Address : 2/F, Building 2A, Taihua Wutong Industrial Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA25102200301 Page 3 of 42 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* .......................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 5 2.6 EUT operation mode ......................................................................................................................... 5 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory ........................................................................................................... 7 3.2 Test Facility..........................................................................…
Text truncated - open the document above for the full version.
FCC ID: 2BUP7-D20B Test Setup Photos of the EUT FCC ID: 2BUP7-D20B
19784 SUNKISSED RIDGE DR,RIVERSIDE, · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |