User Manual 1. Product Introduction This LED constant-current driver adopts long strip aluminum alloy housing with waterproof struct ure. It supplies stable constant-current power for LED luminaires. Widely used for LED wall washe r, linear light, LED strip and outdoor lighting projects. Aluminum casing provides excellent heat dissipation. It is suitable for indoor, damp and outdoor i nstallation environments. 2. Product Appearance - Housing: Extruded aluminum long-strip case, mounting holes on both ends for screw fixing. - Cables: Two-end outgoing black rubber-sheath wires. Input cable: 2-core wire for AC power supply. Output cable: 2-core wire for LED load connection. - Adjustment knob: Side potentiometer for fine-tuning output current (dimmable version). 3. Electrical Specifications(Fill actual parameters) - Input Voltage: AC 100-240V, 50/60Hz - Output Mode: Constant-current - Rated Power: 75W - Efficiency: ≥88% - Power Factor: PF>0.9 - Protection Class: IP65 - Operating Temperature: -20°C ~ +60°C - Housing Material: Aluminum alloy 4. Wiring Instruction Disconnect mains power before wiring! 1. AC Input Connect the two input wires to AC mains (Live / Neutral). Polarity is interchangeable. 2. LED Output Connect output wires to LED light source. Positive / Negative polarity must be distinguished. Reve rse connection is forbidden. 3. Seal wire terminals properly for waterproof after wiring is finished. 5. Installation Guide 1. Fasten driver with screws through mounting holes at two ends. Reserve enough space for heat dissipation. 2. Do not install directly on flammable plastic materials. 3. Avoid sharp bending of cables to prevent sheath crack and water ingress for outdoor applicatio n. 4. Keep away from heat source and ponding area. 6. Built-in Protection - Short-circuit Protection: Automatically shut down when output short-circuited, auto-recovery af ter fault removal. - Over-current Protection: Limit output current under abnormal condition. - Over-voltage Protection: Prevent high-voltage damage to LED chips. - Over-temperature Protection: Reduce power or shut down at overheat; resume operation after cooling. 7. Safety Precautions 1. Installation shall be performed by qualified electrician. Never wire under live power. 2. Output short-circuit shall be avoided; long-time short-circuit may cause permanent damage. 3. Load power cannot exceed driver rated power. 4. Aluminum housing gets hot during operation, avoid scalding. 5. Do not immerse the driver in water. 6. Cut off power before maintenance or replacement. FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2BUQK-OR4ID ZL-S075CW-1500MA, ZL-S030CW-0500MA, ZL-S040CW-1000MA, ZL-S060CW-1000MA Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen LCS Compliance Testing Laboratory Ltd. Contact Name: Martion Lee Address: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Phone: +86-755-82591330 Email: [email protected] Signature: Date: 2026-08-10
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2BUQK-OR4ID ZL-S075CW-1500MA, ZL-S030CW-0500MA, ZL-S040CW-1000MA, ZL-S060CW-1000MA For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-08-12 Signature Date Name / Title: Beatrice Deng / Product Manager Company: ORPHEK LIMITED Address: UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HK, China Phone: +86-13342681141 Fax: N/A E-Mail: [email protected]
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BUQK-OR4ID ZL-S075CW-1500MA, ZL-S030CW-0500MA, ZL-S040CW-1000MA, ZL-S060CW-1000MA We, Applicant Company Name: ORPHEK LIMITED Address: UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HK, China Phone: +86-13342681141 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-08-12 Signature Date Name / Title: Beatrice Deng / Product Manager Company: ORPHEK LIMITED Address: UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HK, China Phone: +86-13342681141 Fax: N/A E-Mail: [email protected]
Page 1 of 1 Rev.2.0 ORPHEK LIMITED WIFI Channel 12 and 13 Declaration Letter We declare the equipment identified below with regards to Channel 12 and 13 capabilities for FCC ID: 2BUQK-OR4ID Declaration Product hardware does not have the capability to operate on Channel 12 and 13. Product hardware has the capability to operate on Channel 12 and 13. However, these two channels will be disabled via software and will not be accessible to user. Product hardware has the capability to operate on Channel 12 and 13. However, all the operated channels can’t be changed in the RF parameter via software. All channels have complied with all of the requirements sets out in FCC Part 15.247. Product hardware has the capability to operate on WiFi Channel 12 and 13, and meets the requirements of KDB 594280 D01 v02r01. Please note: 1.) By default, this device operates in a mode that is compliant with the U.S. requirements. 2.) This device will also use supplemental information such as geo- location data to determine that it is operating outside the U.S., if necessary, to change its power. Such supplemental data will be derived from the following: Global Navigation Satellite System (GNSS)7 sensors in the device Mobile Country Code (MCC),8 or MCC with a Mobile Network code (MNC), received from a CMRS9 carrier and received directly by a receiver on the device Country information derived from multiple adjacent access points (for example using IEEE Std 802.11d provisions) may be permitted on case-by-case basis Other suitable geo-location data based on IP addresses or other reliable source. Name / Title: Beatrice Deng / Product Manager Signature: Phone: +86-13342681141 Email: [email protected] Date: 2026-08-12
ORPHEK LIMITED UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HK, China Date: August 12, 2026 FCC ID: 2BUQK-OR4ID Model Number: ZL-S075CW-1500MA, ZL-S030CW-0500MA, ZL-S040CW-1000MA, ZL-S060CW-1000MA To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, ORPHEK LIMITED hereby declare that our product (Orphek iCon dim driver) Model Number: ZL-S075CW-1500MA, ZL-S030CW-0500MA, ZL-S040CW-1000MA, ZL-S060CW-1000MA PCB board, structure and internal of these model(s) are the same, Only the model’s name and color different, So no additional models were tested. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: Beatrice Deng / Product Manager Company: ORPHEK LIMITED Address: UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HK, China Phone: +86-13342681141 Fax: N/A E-Mail: [email protected]
Page 1 of 3 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 3 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 3 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6
Page 1 of 1 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L4.0cm x 3.0cm) Label Location Orphek iCon dim driver Model: ZL-S075CW-1500MA FCC ID:2BUQK-OR4ID
Page 1 of 6 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 6 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Antenna Page 3 of 6 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 6 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7 Fig. 8 Page 5 of 6 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 9 Fig. 10 Page 6 of 6 FCC ID:2BUQK-OR4ID Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 11 Fig. 12
Page 1 of 9 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation For ORPHEK LIMITED Orphek iCon dim driver Test Model: ZL-S075CW-1500MA Additional Model No.: Please Refer to Page 6 Prepared for : ORPHEK LIMITED Address : UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HONG KONG Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 27, 2023 Number of tested samples : 2 Sample number : A062723001-1, A062723001-2 Serial number : Prototype Date of Test : June 27, 2023 ~ July 22, 2023 Date of Report : July 24, 2023 Page 2 of 9 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report Reference No. ................. : LCSA01066075EA Date of Issue .................................. : July 24, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : ORPHEK LIMITED Address .......................................... : UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HONG KONG Test Specification Standard ......................................... : FCC KDB publication 447498 D01 General RF Exposure Guidance v06 FCC CFR 47 part1 1.1310 FCC CFR 47 part2 2.1091 Test Report Form No. .................. : TRF-4-E-214 A/0 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : Orphek iCon dim driver Trade Mark ..................................... : ORPHEK Test Model ...................................... : ZL-S075CW-1500MA Ratings ........................................... : INPUT: 120-277V~, 50/60Hz, 0.65A OUTPUT: DC 28-48V, 1500mA, Max.75W Result ........................................... : Positive Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Cary Luo/ Technique principal Gavin Liang/ Manager Page 3 of 9 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation EUT......................................... : Orphek iCon dim driver Test Model............................... : ZL-S075CW-1500MA Applicant............................... : ORPHEK LIMITED Address.................................. : UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HONG KONG Telephone............................... : / Fax.......................................... : / Manufacturer........................ : ORPHEK LIMITED Address................................... : UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HONG KONG Telephone............................... : / Fax.......................................... : / Factory................................... : ORPHEK LIMITED Address................................... : UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HONG KONG Telephone............................... : / Fax.......................................... : / Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA01066075EA July 24, 2023 Date of issue Page 4 of 9 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 July 24, 2023 Initial Issue --- Page 5 of 9 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CO…
Text truncated - open the document above for the full version.
Page 1 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for 2.4G WIFI (Conducted Measurement) Product Name: Orphek iCon dim driver Test Model: ZL-S075CW-1500MA Environmental Conditions Temperature: Relative Humidity: 52.2% ATM Pressure: 100.0 kPa Test Engineer: Joker Hu Supervised by: Ling Zhu Page 2 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 DTS Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 9.483 >=0.5 Pass NVNT b 2437 Ant1 9.055 >=0.5 Pass NVNT b 2462 Ant1 9.056 >=0.5 Pass NVNT g 2412 Ant1 15.645 >=0.5 Pass NVNT g 2437 Ant1 15.251 >=0.5 Pass NVNT g 2462 Ant1 15.395 >=0.5 Pass NVNT n20 2412 Ant1 16.29 >=0.5 Pass NVNT n20 2437 Ant1 15.283 >=0.5 Pass NVNT n20 2462 Ant1 15.663 >=0.5 Pass Page 3 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs -6dB Bandwidth NVNT b 2412MHz Ant1 -6dB Bandwidth NVNT b 2437MHz Ant1 Page 4 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2462MHz Ant1 -6dB Bandwidth NVNT g 2412MHz Ant1 Page 5 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2437MHz Ant1 -6dB Bandwidth NVNT g 2462MHz Ant1 Page 6 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2412MHz Ant1 -6dB Bandwidth NVNT n20 2437MHz Ant1 Page 7 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2462MHz Ant1 Page 8 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT b 2412 Ant1 14.44 30 Pass NVNT b 2437 Ant1 14.76 30 Pass NVNT b 2462 Ant1 14.11 30 Pass NVNT g 2412 Ant1 14.04 30 Pass NVNT g 2437 Ant1 14.33 30 Pass NVNT g 2462 Ant1 14.23 30 Pass NVNT n20 2412 Ant1 14.49 30 Pass NVNT n20 2437 Ant1 14.21 30 Pass NVNT n20 2462 Ant1 14.35 30 Pass Page 9 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.3 Maximum Power Spectral Density Level Condition Mode Frequency (MHz) Antenna Conducted PSD (dBm/3kHz) Limit (dBm/3kHz) Verdict NVNT b 2412 Ant1 -9.99 8 Pass NVNT b 2437 Ant1 -8.67 8 Pass NVNT b 2462 Ant1 -10.34 8 Pass NVNT g 2412 Ant1 -12.61 8 Pass NVNT g 2437 Ant1 -12.52 8 Pass NVNT g 2462 Ant1 -12.44 8 Pass NVNT n20 2412 Ant1 -13.63 8 Pass NVNT n20 2437 Ant1 -12.06 8 Pass NVNT n20 2462 Ant1 -14.07 8 Pass Page 10 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Graphs PSD NVNT b 2412MHz Ant1 PSD NVNT b 2437MHz Ant1 Page 11 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity PSD NVNT b 2462MHz Ant1 PSD NVNT g 2412MHz Ant1 Page 12 of 44 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan Di…
Text truncated - open the document above for the full version.
Page 1 of 36 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For ORPHEK LIMITED Orphek iCon dim driver Test Model: ZL-S075CW-1500MA Additional Model No.: Please Refer to Page 6 Prepared for : ORPHEK LIMITED Address : UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HONG KONG Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : June 27, 2023 Number of tested samples : 2 Sample number : A062723001-1, A062723001-2 Serial number : Prototype Date of Test : June 27, 2023 ~ July 22, 2023 Date of Report : July 24, 2023 Page 2 of 36 FCC ID:2BUQK-OR4ID Report No.: LCSA01066075EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA01066075EA Date of Issue .................................. : July 24, 2023 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : ORPHEK LIMITED Address .......................................... : UNIT A7, 12/F, ASTORIA BUILDING, 34 ASHLEY ROAD, TSIM SHA TSUI, HONG KONG Test Specification Standard ......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. .................. : LCSEMC-1.0 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. .......................... : Orphek iCon dim driver Trade Mark ..................................... : ORPHEK Test Model ...................................... : Z…
Text truncated - open the document above for the full version.
1408 Pinon Place Fullerton, · California, 92835 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 29.90 mW |