FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. zhengzhouquanhuanwangluokejiyouxiangongsi/
  3. 2BUSW-LPO-R1

2BUSW-LPO-R1RF remote controller

zhengzhouquanhuanwangluokejiyouxiangongsi
RF remote controller - FCC ID 2BUSW-LPO-R1 - zhengzhouquanhuanwangluokejiyouxiangongsi
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Apr 16, 2026
Application Purpose
Original Equipment
Equipment Note
RF remote controller
Frequency Range
433.92000000 - 433.92000000
Company
zhengzhouquanhuanwangluokejiyouxiangongsi
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

zhengzhouquanhuanwangluokejiyouxiangongsi 2026.03.27 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(i) request for FCC ID: 2BUSW-LPO-R1 [zhengzhouquanhuanwangluokejiyouxiangongsi ] certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. We also certify that, as of the date of the filing of the application, the equipment does not utilize cyber-security or anti-virus software from Kaspersky Lab, Inc, or any of its successors and assignees, which is also on the “covered list”. Sincerely, (Applicant signature) (Applicant printed name) Jinbo Wei zhengzhouquanhuanwangluokejiyouxiangongsi 2026.03.27 Eurofins Electrical and Electronic Testing NA, Inc. 914 West Patapsco Avenue Baltimore, MD 21230 RE: Attestation Statements Part 2.911(d)(5)(ii) request for FCC ID: 2BUSW-LPO-R1 [zhengzhouquanhuanwangluokejiyouxiangongsi ] certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name) Jinbo Wei

Attestation Statements

zhengzhouquanhuanwangluokejiyouxiangongsi Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 03-27-2026 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2BUSW-LPO-R1 Applicant FRN: 0037977030 [zhengzhouquanhuanwangluokejiyouxiangongsi] certifies that, as of the date of the filing of the application, [Baihetian Innovative Solutions] is our designated U.S. agent for service of process for the above referenced FCC ID. [zhengzhouquanhuanwangluokejiyouxiangongsi] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. [Baihetian Innovative Solutions] accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Company Name: Baihetian Innovative Solutions FRN: 0033401605 Contact Person: Kenneth Young StreetAddress: 6837 Chase Rd City/Province/Zip: Dearborn, MI 48126 Phone: 313-395-3113 Email: [email protected] Sincerely, [zhengzhouquanhuanwangluokejiyouxiangongsi] Baihetian Innovative Solutions [Jinbo Wei] Kenneth Young Mar 2026

Cover Letter(s)

zhengzhouquanhuanwangluokejiyouxiangongsi Model Difference 2026-03-27 EUT NAME: RF remote controller Brand Name: MODEL: LPO-R1-12, LPO-R1-09 FCC ID: 2BUSW-LPO-R1 All the model are the same circuit and RF module, except model names and keys. Regards Sincerely Client’s signature: Client’s name / title: Jinbo Wei / General Manager Contact information / address: No. 912, 9th Floor, Building 8, No. 106, Hanghai Middle Road, Erqi District, Zhengzhou City, Henan Province, China

Cover Letter(s)

zhengzhouquanhuanwangluokejiyouxiangongsi 2026.03.27 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: CONFIDENTIALITY REQUEST FOR EUT NAME: RF remote controller Brand Name: MODEL: LPO-R1-12, LPO-R1-09 FCC ID: 2BUSW-LPO-R1 To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the - Block Diagram - Schematics - Operational Description required to be submitted with this application be permanently withheld from public review. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Please contact me if there is any information you may need. Sincerely, Client’s signature: Client’s name / title: Jinbo Wei / General Manager Contact information / address: No. 912, 9th Floor, Building 8, No. 106, Hanghai Middle Road, Erqi District, Zhengzhou City, Henan Province, China

Cover Letter(s)

zhengzhouquanhuanwangluokejiyouxiangongsi 2026.03.27 Eurofins Electrical and Electronic Testing NA, Inc. 914 W. Patapsco Avenue Baltimore, MD 21230 USA RE: LETTER OF AGENT AUTHORIZATION To Whom It May Concern: We, the undersigned, hereby authorize SHENZHEN STS TEST SERVICES CO.,LTD. to act on our behalf in all matters relating to application for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that no party to the application authorized hereunder is subject to the denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C.853(a). This agreement expires one year from the current date. Sincerely, Client’s signature: Client’s name / title: Jinbo Wei / General Manager Contact information / address: No. 912, 9th Floor, Building 8, No. 106, Hanghai Middle Road, Erqi District, Zhengzhou City, Henan Province, China

External Photos

External Photos LPO-R1-12 LPO-R1-09

ID Label/Location Info

Size:10*5m FCC ID: 2BUSW-LPO-R1 Label Location

Internal Photos

Internal Photos LPO-R1-12 Antenna LPO-R1-09

RF Exposure Info

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the ShenZhen STS Test Services Co., Ltd. MPE Report Report No.: STS2603416H01 Issued for zhengzhouquanhuanwangluokejiyouxiangongsi No. 912, 9th Floor, Building 8, No. 106, Hanghai Middle Road, Erqi District, Zhengzhou City, Henan Province, China Product Name: RF remote controller Brand Name: Model Name: LPO-R1-12 Series Model(s): LPO-R1-09 FCC ID: 2BUSW-LPO-R1 Test Standards: FCC 47CFR §2.1093 Page 2 of 8 Report No.: STS2603416H01 TEST REPORT Applicant’s Name ................. : zhengzhouquanhuanwangluokejiyouxiangongsi Address ................................. : No. 912, 9th Floor, Building 8, No. 106, Hanghai Middle Road, Erqi District, Zhengzhou City, Henan Province, China Manufacturer's Name ........... : DONGGUAN GUANYI LIGHT-DECORATION CO.,LTD Address ................................. : Room 901, Building 3, No. 2, West Lake Hot Spring South Road, ShiLong Town, DongGuan City, GuangDong Province, China Product Description Product Name ........................ : RF remote controller Brand Name .......................... : Model Name .......................... : LPO-R1-12 Series Model(s) ...................... : LPO-R1-09 Test Standards ..................... : FCC 47CFR §2.1093 447498 D01 Interim General RF Exposure Guidance v06 The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the ShenZhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ...................... : 2026-03-06 Date (s) of performance of tests ............. : 2026-03-09 to 2026-03-24 Date of Issue .......................................... : 2026-03-25 Test Result .............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 8 Report No.: STS2603416H01 TABLE OF CONTENTS 1. GENERAL INFORMATION 5 1.1 GENERAL DESCRIPTION OF THE EUT 5 1.2 TEST FACTORY 5 2. FCC 47CFR §2.1093 REQUIREMENT 6 2.1 TEST STANDARDS 6 2.2 LIMIT 6 2.3 TEST RESULT 8 Page 4 of 8 Report No.: STS2603416H01 Revision History Rev. Issue Date Report No. Effect Page Contents 00 2026-03-25 STS2603416H01 ALL Initial Issue Page 5 of 8 Report No.: STS2603416H01 1. GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF THE EUT Product Name RF remote controller Brand Name Model Name LPO-R1-12 Series Model(s) LPO-R1-09 Model Difference All the model are the same circuit and RF module, except model names and keys. Product Description The EUT is a RF remote controller Operation Frequency: 433.92MHz 304.25MHz Modulation Type: ASK ASK Antenna Designation: PCB antenna PCB antenna Antenna Gain (Peak) 1.9 dBi 0 dbi Power Rating DC 3V Adapter N/A 1.2 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. : 101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuhai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 Page 6 of 8 Report No.: STS2603416H01 2. FCC 47CFR §2.1093 REQUIREMENT 2.1 TEST STANDARDS The limit for Maximum Permissible Exposure (MPE) specified in KDB 447498 D01 General RF Exposure Guidance v06 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. 2.2 LIMIT Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. Page 7 of 8 Report No.: STS2603416H01 The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] • [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where f(GHz) is the RF channel transmit frequency in GHz. Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. Page 8 of 8 Report No.: STS2603416H01 2.3 TEST RESULT Trun up Mode Detector Power (dBuV/m) @3m Power (dBm) Max Tune up (dBm) ASK PK 75.66 -19.54 -19±1 Note: Power(dBm)= dBuV/m@3m -95.2 Evaluation Result Mode Frequency MHz Separation distance (cm) Power (dBm) ERP (mW) SAR Test Exclusion Threshold SAR Test Exclusion Estimated SAR ASK 433.92 0.5 -18 0.01585 0.00209 Yes / Note: 1. Remark: The worst case gain of the antenna is 1.9 dBi. 2. Threshold at which no SAR required is 0.00209≤ 3.0 for 1-g SAR, Separation distance ≤ 5mm. ※※※※※END OF THE REPORT※※※※※

Test Report

Product specification Antenna module on the system board Frequenc Range 433.92MHz Ant. Port Input Pwr. (dBm) 0.5db Tot. Rad. Pwr. (dBm) -1.2 (Input pwr – loss pwr) Peak EIRP(dBm) 1.2 Directivity (dBi) 1 (all direction antenna) Efficiency (dB) 60.2 % Gain (dBi) 1.9 Input Impendence(ohm) 50 Polarization Type Vertical & Horizontal V. S .W. R < 1.4 Antenna Layout & module on the system board

Test Report

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Radio Test Report Report No.: STS2603416W01 Issued for zhengzhouquanhuanwangluokejiyouxiangongsi No. 912, 9th Floor, Building 8, No. 106, Hanghai Middle Road, Erqi District, Zhengzhou City, Henan Province, China Product Name: RF remote controller Brand Name: Model Name: LPO-R1-12 Series Model(s): LPO-R1-09 FCC ID: 2BUSW-LPO-R1 Test Standards: FCC Part 15.231 Page 2 of 31 Report No.: STS2603416W01 TEST REPORT Applicant’s Name ................. : zhengzhouquanhuanwangluokejiyouxiangongsi Address ................................. : No. 912, 9th Floor, Building 8, No. 106, Hanghai Middle Road, Erqi District, Zhengzhou City, Henan Province, China Manufacturer's Name .......... : DONGGUAN GUANYI LIGHT-DECORATION CO.,LTD Address ................................. : Room 901, Building 3, No. 2, West Lake Hot Spring South Road, ShiLong Town, DongGuan City, GuangDong Province, China Product Description Product Name ....................... : RF remote controller Brand Name .......................... : Model Name .......................... : ... : LPO-R1-12 Series Model(s) .................... : LPO-R1-09 Test Standards ..................... : FCC Part15.231 Test Procedure ...................... : ANSI C63.10-2020 This device described above has been tested by STS, the test results show that the equipment under test (EUT) is in compliance with the IC requirements. And it is applicable only to the tested sample identified in the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. Date of Test ........................................... : Date of receipt of test item ..................... : 2026-03-06 Date (s) of performance of tests ............. : 2026-03-09 to 2026-03-24 Date of Issue .......................................... : 2026-03-25 Test Result.............................................. : Pass Testing Engineer : (Aaron Bu) Technical Manager : (Skylar Li) Authorized Signatory : (Bovey Yang) Page 3 of 31 Report No.: STS2603416W01 TABLE OF CONTENTS Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 6 1.2 MEASUREMENT UNCERTAINTY 6 2. GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF THE EUT 7 2.2 DESCRIPTION OF THE TEST MODES 8 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 2.4 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.5 EQUIPMENTS LIST 11 3. EMC EMISSION TEST 12 3.1 CONDUCTED EMISSION MEASUREMENT 12 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 13 3.4 TEST RESULTS 13 4. RADIATED EMISSION MEASUREMENT 14 4.1 RADIATED EMISSION LIMITS 14 4.2 TEST PROCEDURE 16 4.3 DEVIATION FROM TEST STANDARD 16 4.4 TEST SETUP 17 4.5 EUT OPERATING CONDITIONS 18 4.6 TEST RESULTS 18 4.7 FIELD STRENGTH CALCULATION 19 5. BANDWIDTH TEST 23 5.1 LIMIT 23 5.2 TEST REQUIREMENTS 23 5.3 TEST PROCEDURE 23 5.4 TEST SETUP 23 5.5 EUT OPERATION CONDITIONS 23 5.6 TEST RESULTS 24 6. DUTY CYCLE 25 6.1 TEST PROCEDURE 25 6.2 TEST SETUP 25 6.3 EUT OPERATION CONDITIONS 25 6.4 TEST RESULTS 26 Page 4 of 31 Report No.: STS2603416W01 TABLE OF CONTENTS Page 7. AUTOMATICALLY DEACTIVATE 28 7.1 STANDARD REQUIREMENT 28 7.2 TEST PROCEDURE 28 8. ANTENNA REQUIREMENT 30 8.1 STANDARD REQUIREMENT 30 8.2 EUT ANTENNA 30 APPENDIX 1-PHOTOS OF TEST SETUP 31 Page 5 of 31 Report No.: STS2603416W01 Revision History Rev. Issue Date Report No. Effect Page Contents 00 2026-03-25 STS2603416W01 ALL Initial Issue Page 6 of 31 Report No.: STS2603416W01 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part 15.231,Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A -- 15.205(a)/15.209/ 15.231.(b) Radiated Spurious Emission PASS -- 15.231(a)(1)/ 15.231(b)(2) Transmission requirement PASS -- 15.231(C) 20 dB Bandwidth PASS -- 15.203 Antenna Requirement PASS -- Note: (1) “N/A” denotes test is not applicable in this Test Report. (2) All tests are according to ANSI C63.10-2020. 1.1 TEST FACTORY SHENZHEN STS TEST SERVICES CO., LTD Add. :101, Building B, Zhuoke Science Park, No.190 Chongqing Road, ZhanChengShequ, Fuh ai Sub-District, Bao’an District, Shenzhen, Guang Dong, China FCC test Firm Registration Number: 625569 IC test Firm Registration Number: 12108A A2LA Certificate No.: 4338.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.751dB 2 Unwanted Emissions, conducted ±2.888dB 3 All emissions, radiated 9K-30MHz ±2.48dB 4 All emissions, radiated 30M-1GHz ±2.52dB 5 All emissions, radiated 1G-18GHz ±3.48dB 6 All emissions, radiated>18GHz ±4.18dB 7 Conducted Emission (9KHz-150KHz) ±2.48dB 8 Conducted Emission (150KHz-30MHz) ±2.52dB 9 Occupied Channel Bandwidth ±3.6% 10 Power Spectral Density, conducted ±1.214dB 11 Duty Cycle ±3.2% Page 7 of 31 Report No.: STS2603416W01 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name RF remote controller Trade Name Model Name LPO-R1-12 Series Model LPO-R1-09 Model Difference All the model are the same circuit and RF module, except model names and keys. Product Description The EUT is a RF remote controller Operation Frequency: 433.92MHz Modulation Type: ASK Antenna Designation: PCB antenna Antenna Gain(Peak) 1.9 dBi More details of EUT technical specification, please refer to the User Manual. Channel List Please refer to the Note 3. Power Rating DC 3V Connecting I/O Port(s) Please refer to the Note 1. Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications orthe User Manual. 2. Table for filed Antenna…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 FCC ID: 2BUSW-LPO-R1 Setup photo RE (30MHz-1GHz) RE (Above 1GHz)

Contact Information

Applicant

Jinbo Wei(General Manager)
[email protected]Fax: -

Technical Contact

Baihetian Innovative SolutionsKenneth Young
[email protected]

6837 Chase Rd, · Dearborn MI, 48126 · United States

Test Firm

SHENZHEN STS TEST SERVICES CO.,LTD.Bovey Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.92 MHz - 433.92 MHz-
Confidentiality
Long Term
Grant Notes
/