FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangzhou Xiangyun Flavor Technology Co.,Ltd/
  3. 2BUUT-B2

2BUUT-B2remote control

Guangzhou Xiangyun Flavor Technology Co.,Ltd

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Mar 23, 2026
Application Purpose
Original Equipment
Equipment Note
remote control
Frequency Range
433.90000000 - 433.90000000
Company
Guangzhou Xiangyun Flavor Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

GuangzhouXiangyunFlavorTechnologyCo.,Ltd. Address:302,B2Building,No.7MinyingDadaoxi,XintangTown,Zengcheng District,Guangzhou,Guangdong,China FRN:0037992187 Date:2026-03-19 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BUUT-B2 GuangzhouXiangyunFlavorTechnologyCo.,Ltd.certifiesthat,asofthedateofthefilingof theapplication,XINNAISIINCisourdesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID.GuangzhouXiangyunFlavorTechnologyCo.,Ltd.acceptsto maintainanagentfornolessthanoneyearafterthegranteehasterminatedallmarketing andimportationortheconclusionofanyCommission-relatedproceedinginvolvingthe equipment. XINNAISIINCaccepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:XINNAISIINC Address:1500NGRANTSTSTER,DENVER,CO80203 FRN:0037518289 ContactPerson:KiKi Tel.:+01(951)893-3011 Email:[email protected] Sincerely, SignedonbehalfofGuangzhouXiangyun FlavorTechnologyCo.,Ltd. SignedonbehalfofXINNAISIINC Name: Name: Title:ManagerTitle:Manager Date:2026-03-19Date:2026-03-19

Attestation Statements

Rev9/15/2025 GuangzhouXiangyunFlavorTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:Mar.19,2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BUUT-B2 GuangzhouXiangyunFlavorTechnologyCo.,Ltd.certifiesthattheequipmentforwhichauthorization issoughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. GuangzhouXiangyunFlavorTechnologyCo.,Ltd.certifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). █Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, JinchaoLi GuangzhouXiangyunFlavorTechnologyCo.,Ltd. Rev9/15/2025 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:Mar.19,2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BUUT-B2 GuangzhouXiangyunFlavorTechnologyCo.,Ltd.certifiesthat,asofthedateofthefilingofthe application,theapplicantisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, JinchaoLi GuangzhouXiangyunFlavorTechnologyCo.,Ltd.

Cover Letter(s)

GuangzhouXiangyunFlavorTechnologyCo.,Ltd. Date:Mar.19,2026 ProductModelNumber:B2 FCCID:2BUUT-B2 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:JinchaoLi Email: [email protected] Telephone: 13825105513 Onbehalfof:GuangzhouXiangyunFlavorTechnologyCo.,Ltd

Cover Letter(s)

GuangzhouXiangyunFlavorTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:March19,2026 Subject;RequestforConfidentiality FCCID:2BUUT-B2 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. █SchematicDiagram █BlockDiagram PartsList █OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); █ExternalPhotos █TestSetupPhotos █InternalPhotos █UserManual █For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:JinchaoLi Title:Manager

ID Label/Location Info

Size: 8*25mm Label Location FCC ID: 2BUUT- B2

RF Exposure Info

FCC ID: 2BUUT- B2 RF Exposure Evaluation According to KDB 447498 D01 General RF Exposure Guidance v06 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Here, The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. For OOK Maximum Output Power (dBm) Tune-up Power(dBm) Max Tune-up Power(dBm) Max Power(W) Frequency(MHz) Min. distance(mm) Calc. thresholds limit -18.29 -18±1 -17 0.000015 433.90 5 0.002 3.0 Note: TX frequency range: 433.90MHz(Worst result) Device category: Portable device (Distance: 5mm) Max. Field Strength: 76.87 dBuV/m @3m EIRP=E-104.7+20logD=76.87-104.7+20log3=-18.29dBm Maximum Output Power: -18.29dBm Tune-up: -18±1dBm So a SAR test is not required

Test Report

- Page 1 of 27 - Report No.: HB20260228050E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Test Report Product: remote control Trade Mark: N/A Model Number: B2 FCC ID: 2BUUT- B2 Prepared for Guangzhou Xiangyun Flavor Technology Co., Ltd. 302,B2 Building,No.7 Minying Dadaoxi,Xintang Town,Zengcheng District,Guangzhou,Guangdong,China Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110 Website: http://www.sz-hongbiao.com - Page 2 of 27 - Report No.: HB20260228050E-01 Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China Tel: (86-755) 29989321 Fax: (86-755) 29985110 Web:www.sz-hongbiao.com Table of Contents 1 GENERAL DESCRIPTION .................................................................................................................. 5 1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE .............................................................................................................................................................. 5 1.3 OPERATION CHANNEL LIST ........................................................................................................................................... 5 1.4 TEST SETUP .............................................................................................................................................................. 5 1.5 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................. 6 3 TEST FACILITIES AND ACCREDITATIONS ............................................................................................................ 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 7 3.4 TEST SOFTWARE ........................................................................................................................................................ 8 4 LIST OF TEST EQUIPMENT ................................................................................................................................ 9 5 TEST ITEM AND RESULTS ............................................................................................................................... 11 5.1 ANTENNA REQUIREMENT .......................................................................................................................................... 11 5.1.1 Standard Requirement ............................................................................................................................. 11 5.1.2 Test Result ................................................................................................................................................. 11 5.2 AC POWER LINE CONDUCTED EMISSION ...................................................................................................................... 12 5.2.1 Limits ........................................................................................................................................................ 12 5.2.2 Test Procedures ......................................................................................................................................... 12 5.2.3 Test Setup.................................................................................................................................................. 13 5.2.4 Test Result ................................................................................................................................................. 13 5.3 RADIATED EMISSION FIELD STRENGTH OF FUNDAMENTAL AND HARMONIC EMISSIONS .......................................................... 14 5.3.1 Limits ........................................................................................................................................................ 14 5.3.2 Test Procedures ......................................................................................................................................... 15 5.3.3 Test Setup.................................................................................................................................................. 16 5.3.4 Test Result ................................................................................................................................................. 17 5.4 RADIATED EMISSION AND BAND EDGE SPURIOUS EMISSION ............................................................................................. 19 5.4.1 Limit .......................................................................................................................................................... 19 5.4.2 Test Procedure .......................................................................................................................................... 19 5.4.3 Test Setup.................…

Text truncated - open the document above for the full version.

Test Report

1.GeneralDescription 1.1ProductInformation Manufacturer: ZHUHAIJIELITECHNOLOGYCO.,LTD Address: No.107,ShihuaWestRoad,ZhuhaiCity,GuangdongProvince Productname:PCBAntenna Modelname:/ Operationfrequency:433.90MHz Antennatype:PCBAntenna Antennagain:0.45dBi Impedance:50ohm AntennaLength13mm AntennaWidth10mm AntennaView: 2.OTATest 2.1Gain Frequency(MHz)Gain(dBi)Polarity 433.900.45Horizontal 433.90-0.97Vertical 2.2RadiationPatternView (433.90MHz) (433.90MHz)

Contact Information

Applicant

Jinchao Li
[email protected]Fax: 13825105513

Technical Contact

XINNAISI INCKi Ki
[email protected]

1500 N GRANT STSTER, · United States

Test Firm

Shenzhen HongBiao Certification& Testing Co., LtdLeo Su
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231433.9 MHz - 433.9 MHz15.00 µW