Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
TCB CALL página 1 File FCC ID: 2BV69-FDC168SL Please upload an exhibit that explains how does the TCB verify the new agent information: 1- Is the address of the agent a valid physical US mailing address (not a US post office box, not a virtual mailbox, not P.O. Boxes, not a vacant lot, not a public building, etc.) ○ We have checked if the address exists in a real and potential building (Google maps) + official US register, after this verification and the evidence below we can guarantee the following: not a US post office box not a virtual mailbox not P.O. Boxes not a vacant lot not a public building(note) ► We checked the FCC FRN Search based on the information provided by the grantee. On the official register from : https://opencorporates.com/companies/us_il/LLC_12842678 In google: TCB CALL página 2 Bank information TCB CALL página 3 ► CONCLUSION by TCB: The ASOP defined and provided by grantee is VALID and confirmed. Therefore the exhibit "C5266091_X23_Ed1_US_Agent_Letter" included in the file is ok. 2- Is the agent physically located at that valid US address such that the agent can be legally served at that address? Yes , check above 3- Has the listed agent clearly agreed in writing to serve as the agent for the grantee at that address? Yes, it is included in the exhibit "C5266091_X23_Ed1_US_Agent_Letter" >
1/1 US Agent for Service of Process LETTER OF ATTESTATION TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 US Agent for Service of Process: Company Name: FCC US Agent, LLC FRN: 0033402884 Address: 3722 Illinois Avenue, Saint Charles, IL, 60174, USA Contact Person: Tim Payne Phone: 708-571-3148 Email: [email protected] Applicant: Company name: Shenzhen Shang Ding Xing Technology Co., Ltd. Product Description: tablet PC Grantee code: 2BV69 FRN: 0038441705 FCC ID: 2BV69-FDC168SL Contact Name: Tangwei Address: 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Telephone No.: 13640983737 Email: [email protected] [Shenzhen Shang Ding Xing Technology Co., Ltd.] certifies that, as of the date of this filing of the application with the TCB, [FCC US Agent, LLC] is our designated US agent for service of process for the above referenced FCC ID. [Shenzhen Shang Ding Xing Technology Co., Ltd.] accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission related proceeding involving equipment. [FCC US Agent, LLC] accepts, as of the date of the filing of the application, the obligation of the designated US agent for service of process for the above reference FCC ID. The US Agent for Service of Process is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. The Applicant is aware of and agrees to comply with the requirements outlined in the FCC Equipment Authorization Program, Report and Order FCC 22-84, and clause § 2.911. Date: 2026/07/1 Applicant’s Name: Tangwei US Agent’s Name: Tim Payne Title:manager Title: manager 1/1 Signature Signature
Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1 TO: Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 The Commission adopted rules that prohibit equipment authorization for “covered” telecommunications equipment and video surveillance equipment produced by entities identified on the Commission’s Covered List 1 , which is periodically updated. See the Covered List for more details. This Attestation Statement is to confirm that we follow the Section 2.911(d)(5)(i)-(ii) Applicant Company name: Shenzhen Shang Ding Xing Technology Co., Ltd. Grantee code: 2BV69 FCC ID: 2BV69-FDC168SL FRN: 0038441705 Contact Name: Tangwei Address: 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Telephone No: (86)755-84528007 Fax No: (86) 755-84528889 Email: [email protected] i. [Shenzhen Shang Ding Xing Technology Co., Ltd.] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. The applicant must sign this certification. ii. [Shenzhen Shang Ding Xing Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] (as a specifically named entity or any of its subsidiaries or affiliates) identified on the Covered List as an entity producing “covered” equipment. The applicant must sign this certification. [Shenzhen Shang Ding Xing Technology Co., Ltd.] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List as an entity producing “covered” equipment . Date: 2026/7/1 Applicant’s Name: Tangwei Title: Manager Signature 1 The Commission’s Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commission’s website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes “covered” equipment. https://www.fcc.gov/supplychain/coveredlist Attestation Statement. Old Code: C5266091 24 New Code: 00015544 Ed.3 Change reason: FRN is added to the Applicant information section. 1/1
Shenzhen Shang Ding Xing Technology Co., Ltd. Code 00018768 Ed. 1 I tem 1. The device is able to install software/program installation? Yes, go to Item 2. □No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky cybersecurity or anti-virus software. Item 2. Technical Requirements for Kaspersky Cybersecurity Software: # General Requirements (For all Devices) Yes / No or N/A Comments 1 Internet connection for activation and updates (For all Operating Systems) N/A # General Requirements (For Windows Devices) Yes / No or N/A Comments 1 Storage: 1500 MB free space on the hard drive N/A 2 Operating System: Microsoft Windows 8, 8.1, 10 & 11 Home / Pro / Enterprise Microsoft Windows 7 Starter / Home Basic & Premium / Professional / Ultimate SP1 or higher N/A 3 Processor: 1 GHz or higher (x86 or x64) N/A 4 Memory (RAM)1 GB (32-bit) or 2 GB (64-bit) N/A 5 Screen Resolution: Minimum resolution of 1024 x 768 N/A # General Requirements (For macOS devices) Yes / No or N/A Comments Device tablet PC Company name Shenzhen Shang Ding Xing Technology Co., Ltd. Grantee code 2BV69 FCC ID 2BV69-FDC168SL FRN 0038441705 Contact name Tangwei Address 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Telephone number 13640983737 E- mail [email protected] Chipset/module information MT6625L for BT/WIFI Operating System (if applicable) Android Storage Capacity (hard drive or other permanent memory storage, if applicable) RAM:16.0 GB ROM:1024.0 GB 2 1 Operating System macOS® 13 – 14 N/A 2 Memory (RAM)4 GB N/A 3 Storage: 3455 MB free space on the hard drive N/A # General Requirements (For Android Devices) Yes / No or N/A Comments 1 Storage: 150 MB free space YES RAM:16.0 GB ROM:1024.0 2 Operating System: Android™ 10 – 14 YES Android16 3 Screen Resolution: Minimum resolution of 320 x 480 YES resolution of 1920 x 1080 # General Requirements (for iOS devices) Yes / No or N/A Comments 1 Storage: 150 MB free space N/A 2 Operating System: iOS® 17 N/A # General Requirements (For Linux system) Yes / No or N/A Comments 1 Hard drive: 1 GB of free space N/A 2 CPU: Intel Pentium 1 GHz or higher N/A 3 RAM: 1 GB N/A 4 Minimum software requirements: AlmaLinux OS 8 or later; AlterOS 7.5 or later; Astra Linux Common Edition 2.12 or later; CentOS 6.7 or later; Debian GNU/Linux 10.0 or later; EulerOS 2.0 or later; Oracle Linux 7.3 or later ; Red Hat Enterprise Linux 6.7 or later ; Rocky Linux 8.5 or later ; SUSE Linux Enterprise Server 12.5 or later; Ubuntu 12.04 or later ; Uncom OS Home / Business / Education / Enterprise 2.2 or later; ALT Linux Workstaton / Workstation K / Server / Education 8 or later; ROSA Linux Workstation / Server 12 or later ; RED OS 7.3 and later ; N/A After reviewed the technical requirements, is the device capable of supporting the installation of Kaspersky software? Yes, go to Item 3. □No. In this case, the rest of the items do not apply. The device cannot support installation of Kaspersky software Item 3.Connectivity Capabilities: # Physical Interface Purpose Justification 1 1 The justification field is used to justify why the software cannot be received through that interface. Check the annex for more indications. 3 1 USB Type-C port Charging or data transfer -Built-in firewall that blocks software downloads 2 Audio jack Contect to earphone for listening to music or other audio files Cannot install software through the audio port # Wireless Interface Purpose Justification 1 1 Wi-Fi It can be connected to the network for file or video downloading -Built-in firewall that blocks software downloads 2 Bluetooth Pairing limited to authorized devices -Built-in firewall that blocks software downloads After the review of this items, the device: □Cannot support installation of any cybersecurity or anti-virus software on the covered list. Potentially can operate with any cybersecurity or anti-virus software on the covered list – additional third-party proof is provided to demonstrate compliance with requirements as of 2.911(d)5(i),(ii) – “Proof of Compliance with Covered List Software Requirements” of this document applies Signature: Name: Date: 2025.7.15 Proof of Compliance with Covered List Software Requirements 1.Did a test Firm or third party (other than the certification body and applicant) provide a list of software installed on the device and after scan results with no evidence of Kaspersky software? ☒YES ☐NO ☐N/A If YES, provide: ( 4 File Name: Kaspersky Software Security Requirements Statement Third-Party Name (including Test Firm: Shenzhen NTEK Testing Technology Co., Ltd Has other objective evidence been provided that no Kaspersky software is installed? ☒YES ☐NO ☐N/A If YES, provide: 5 Name / Title: Allen Liu/Project Engineer Company Name: Shenzhen NTEK Testing Technology Co., Ltd Address: No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel: +86 15820947194 E-Mail: [email protected]
Shenzhen Shang Ding Xing Technology Co., Ltd. Family models declaration letter. 7/15/2026 We Company: Shenzhen Shang Ding Xing Technology Co., Ltd. Address: 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Product: tablet PC Model Name: Q85 Family Model: Q8, Q86, Q87, Q88, Q7, Q75, Q78, T7, T71, T72, T73, T75, Q80, Q90, Z6, Z7, Z8, Z9, Z10 FCC ID:2BV69-FDC168SL We (Shenzhen Shang Ding Xing Technology Co., Ltd.) hereby state that all the models are electrical identical including the same software parameter and hardware design (i.e., circuit design, PCB Layout, RF module/circuit, antenna type(s) and antenna location, components on PCB, etc.), same mechanical structure and design (including product enclosure, materials, etc.), All models have the same circuit and RF module,with Only the color, camera appearance different. Thanks Sincerely, Signature [Name] Tangwei [Title] manager [email protected]
C5266091_X10_Ed.2 1/1 < Shenzhen Shang Ding Xing Technology Co., Ltd. > Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2026/7/1 Subject: Request for Confidentiality FCC ID: 2BV69-FDC168SL To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos ☐ ☒ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report ☐ ☐ Test Setup Photos No ☒ User’s Manual ☐ NOTE 1 ☒ Internal Photos ☐ NOTE 1 ☒ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of __180_ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential C5266091_X10_Ed.2 1/1 documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Tangwei Title:Manager
C5266091_X8_Ed.1 1/1 Letter of Authorization < Shenzhen Shang Ding Xing Technology Co., Ltd. > Company: Launch Tech Co., Ltd. Address: 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Product Name: tablet PC Model Number: Q85, Q8, Q86, Q87, Q88, Q7, Q75, Q78, T7, T71, T72, T73, T75, Q80, Q90, Z6, Z7, Z8, Z9, Z10 FCC Identifier: 2BV69-FDC168SL We authorize LGAI Technological Center S.A., Ronda de la Font delCarme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Tangwei Date: 02/07/2026 Title: manager Signature of applicant:
Location
Page 1 of 84 Report No.: N26042907907E FCC SAR EVALUATION REPORT In accordance with the requirements of FCC 47 CFR Part 2(2.1093), ANSI/IEEE C95.1-1992 and IEEE Std 1528-2013 Product Name: tablet PC Trademark: N/A Model Name: Q85 Family Model: Q8,Q85,Q86,Q87,Q88,Q7,Q75,Q78,T7,T71,T72,T73,T75, Q80,Q90,Z6,Z7,Z8,Z9,Z10 Report No.: N26042907907E FCC ID: 2BV69-FDC168SL Prepared for Shenzhen Shang Ding Xing Technology Co., Ltd. 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Prepared by Shenzhen NTEK Testing Technology Co., Ltd. No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel. 0755-23200050 Website: http://www.ntek.org.cn Page 2 of 84 Report No.: N26042907907E TEST RESULT CERTIFICATION Applicant’s name ................. : Shenzhen Shang Ding Xing Technology Co., Ltd. Address ................................. : 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Manufacturer's Name ........... : Shenzhen Shang Ding Xing Technology Co., Ltd. Address ................................. : 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Product description Product name ........................ : tablet PC Trademark ............................ : N/A Model Name ......................... : Q85 Family Model ......................... : Q8,Q85,Q86,Q87,Q88,Q7,Q75,Q78,T7,T71,T72,T73,T75,Q80,Q90,Z6, Z7,Z8,Z9,Z10 Standards ............................. : FCC 47 CFR Part 2(2.1093) ANSI/IEEE C95.1-1992 IEEE Std 1528-2013 Published RF exposure KDB procedures This device described above has been tested by Shenzhen NTEK. In accordance with the measurement methods and procedures specified in IEEE Std 1528-2013 and KDB 865664 D01. Testing has shown that this device is capable of compliance with localized specific absorption rate (SAR) specified in FCC 47 CFR Part 2(2.1093) and ANSI/IEEE C95.1-1992. The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK, this document may be altered or revised by Shenzhen NTEK, personal only, and shall be noted in the revision of the document. Test Sample Number S2605070102-1# Date of Test Date (s) of performance of tests ............. : May. 14, 2026, 2026~ May. 23, 2026 Date of Issue .......................................... : Jun. 11, 2026 Test Result .............................................. : Pass Prepared By : Reviewed By : Approved By : Owen Xiao (Project Engineer) Aaron Cheng (Supervisor) Alex Li (Manager) Page 3 of 84 Report No.: N26042907907E ※ ※ Revision History ※ ※ REV. DESCRIPTION ISSUED DATE REMARK Rev.1.0 Initial Test Report Release Jun. 11, 2026 Owen Xiao Page 4 of 84 Report No.: N26042907907E TABLE OF CONTENTS 1. General Information .......................................................................................... 6 1.1. RF exposure limits .................................................................................. 6 1.2. Statement of Compliance ....................................................................... 7 1.3. EUT Description ..................................................................................... 7 1.4. Test specification(s) ................................................................................ 8 1.5. Ambient Condition ................................................................................. 8 1.6. Facilities And Accreditations .................................................................. 8 1.6.1. Facilities ........................................................................................... 8 1.6.2. Laboratory Accreditations And Listings ............................................ 8 2. SAR Measurement System ................................................................................. 9 2.1. SATIMO SAR Measurement Set-up Diagram ........................................... 9 2.2. Robot ................................................................................................... 10 2.3. E-Field Probe ........................................................................................ 11 2.3.1. E-Field Probe Calibration ................................................................ 11 2.4. SAM phantoms .................................................................................... 12 2.4.1. Technical Data ................................................................................ 13 2.5. Device Holder ...................................................................................... 14 2.6. Test Equipment List .............................................................................. 15 3. SAR Measurement Procedures ........................................................................ 18 3.1. Power Reference.................................................................................. 18 3.2. Area scan & Zoom scan ........................................................................ 18 3.3. Description of interpolation/extrapolation scheme ............................. 20 3.4. Volumetric Scan ................................................................................... 20 3.5. Power Drift .......................................................................................... 20 4. System Verification Procedure ......................................................................... 21 4.1. Tissue Verification ................................................................................ 21 4.1.1. Tissue Dielectric Parameter Check Results ................…
Text truncated - open the document above for the full version.
Report No.: N26042907906E Version.1.2 Page 1 of 71 FCC RADIO TEST REPORT FCC ID:2BV69-FDC168SL Product: tablet PC Trade Mark: N/A Model Name: Q85 Family Model: Q8, Q86, Q87, Q88, Q7, Q75, Q78, T7, T71, T72, T73, T75, Q80, Q90, Z6, Z7, Z8, Z9, Z10 Report No.: N26042907906E Prepared for Shenzhen Shang Ding Xing Technology Co., Ltd. 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Prepared by Shenzhen NTEK Testing Technology Co., Ltd. No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China Tel. 0755-23200050 Website: http://www.ntek.org.cn Report No.: N26042907906E Version.1.2 Page 2 of 71 TEST RESULT CERTIFICATION Applicant’s name ................. : Shenzhen Shang Ding Xing Technology Co., Ltd. Address ................................. : 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Manufacturer's Name ........... : Shenzhen Shang Ding Xing Technology Co., Ltd. Address ................................. : 505, Building F, Longjing Science Park, 335 Bu Long Road, Ma An Tang Community, Pazhai Street, Longgang District, Shenzhen City. Product description Product name ............................ : tablet PC Model and/or type reference : Q85 Family Model ............................. : Q8, Q86, Q87, Q88, Q7, Q75, Q78, T7, T71, T72, T73, T75, Q80, Q90, Z6, Z7, Z8, Z9, Z10 Sample number S2601090021-1# Standards ............................. : FCC Part15.407 Test procedure ............................... : ANSI C63.10-2020 + Cor. 1-2023+C63.10a-2024 + Errata to C63.10a-2024 and KDB 789033 D02 General UNII Test Procedures New Rules v02r01 This device described above has been tested by NTEK, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements/ the Industry Canada requirements.. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of NTEK, this document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of the document. Date of Test ........................................... : Date (s) of performance of tests ............. : Apr. 29, 2026 ~ Jun. 23, 2026 Date of Issue .......................................... : Jun. 23, 2026 Test Result .............................................. : Pass Prepared By : Reviewed By : Approved By : Allen Liu (Project Engineer) Aaron Cheng (Supervisor) Alex Li (Manager) Report No.: N26042907906E Version.1.2 Page 3 of 71 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 FACILITIES AND ACCREDITATIONS 6 1.2 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 10 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 12 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 13 3 . TEST REQUIREMENTS 15 3.1 CONDUCTED EMISSION MEASUREMENT 15 3.2 RADIATED EMISSION MEASUREMENT 20 3.3 POWER SPECTRAL DENSITY TEST 50 3.4 26DB & 99% EMISSION BANDWIDTH 53 3.5 MINIMUM 6 DB BANDWIDTH 55 3.6 MAXIMUM CONDUCTED OUTPUT POWER 57 3.7 OUT OF BAND EMISSIONS 61 3.8 SPURIOUS RF CONDUCTED EMISSIONS 63 3.9 FREQUENCY STABILITY MEASUREMENT 64 4. ANTENNA REQUIREMENT 71 4.1 STANDARD REQUIREMENT 71 4.2 EUT ANTENNA 71 Report No.: N26042907906E Version.1.2 Page 4 of 71 Revision History Report No. Version Description Issued Date N26042907906E Rev.01 Initial issue of report Jun. 23, 2026 Report No.: N26042907906E Version.1.2 Page 5 of 71 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.407) , Subpart E Standard Section Test Item Judgment Remark 15.207 AC Power Line Conducted Emissions PASS 15.209(a), 15.407 (b)(1) 15.407 (b)(4) Spurious Radiated Emissions PASS 15.407 (a)(1) 15.407 (a)(3) 26 dB and 99% Emission Bandwidth PASS 15.407(e) Minimum 6 dB bandwidth PASS 15.407 (a)(1) 15.407 (a)(3) Maximum Conducted Output Power PASS 15.407(b)(1) 15.407(b)(4) Band Edge PASS 15.407 (a)(1) 15.407 (a)(3) Power Spectral Density PASS 15.407(b) Spurious Emissions at Antenna Terminals PASS 15.203 Antenna Requirement PASS 15.407(c) Automatically discontinue transmission PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Report No.: N26042907906E Version.1.2 Page 6 of 71 1.1 FACILITIES AND ACCREDITATIONS FACILITIES All measurement facilities used to collect the measurement data are located at No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR Publication 22. LABORATORY ACCREDITATIONS AND LISTINGS Site Description CNAS-Lab. : The Certificate Registration Number is L5516. IC-Registration The Certificate Registration Number is 9270A. CAB identifier:CN0074 FCC- Accredited Test Firm Registration Number: 463705. Designation Number: CN1184 A2LA-Lab. The Certificate Registration Number is 4298.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Name of Firm : Shenzhen NTEK Testing Technology Co., Ltd. Site Location : No. 24 Xinfa East Road, Xiangshan Community, Xinqiao Street, Baoan District, Shenzhen, Guangdong, People's Republic of China. 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confid…
Text truncated - open the document above for the full version.
Manufacturer: Shenzhen Junyu Communication Equipment Co., Ltd. Address: Room 506, Qiurui Creative Park, No. 4 Bayue First Street, Shuijing Community, Jihua Subdistrict, Longgang District, Shenzhen Shenzhen Junyu Communication Equipment Co., Ltd. WiFi
Report No.: N26042907906E Page 1 of 80 WIFI 5.2G: Duty Cycle Condition Mode Frequency (MHz) Antenna Duty Cycle (%) Correction Factor (dB) 1/T (kHz) NVNT a 5180 Ant1 98.19 0.08 0.71 NVNT a 5200 Ant1 98.2 0.08 0.72 NVNT a 5240 Ant1 98.21 0.08 0.72 NVNT ac20 5180 Ant1 98.07 0.08 0.77 NVNT ac20 5200 Ant1 98.08 0.08 0.77 NVNT ac20 5240 Ant1 98.09 0.08 0.77 NVNT ac40 5190 Ant1 96.37 0.16 1.54 NVNT ac40 5230 Ant1 96.37 0.16 1.54 NVNT n20 5180 Ant1 98.08 0.08 0.77 NVNT n20 5200 Ant1 98.09 0.08 0.77 NVNT n20 5240 Ant1 98.09 0.08 0.77 NVNT n40 5190 Ant1 96.38 0.16 1.56 NVNT n40 5230 Ant1 96.36 0.16 1.54 Duty Cycle NVNT a 5180MHz Ant1 Duty Cycle NVNT a 5200MHz Ant1 Report No.: N26042907906E Page 2 of 80 Duty Cycle NVNT a 5240MHz Ant1 Duty Cycle NVNT ac20 5180MHz Ant1 Report No.: N26042907906E Page 3 of 80 Duty Cycle NVNT ac20 5200MHz Ant1 Duty Cycle NVNT ac20 5240MHz Ant1 Report No.: N26042907906E Page 4 of 80 Duty Cycle NVNT ac40 5190MHz Ant1 Duty Cycle NVNT ac40 5230MHz Ant1 Report No.: N26042907906E Page 5 of 80 Duty Cycle NVNT n20 5180MHz Ant1 Duty Cycle NVNT n20 5200MHz Ant1 Report No.: N26042907906E Page 6 of 80 Duty Cycle NVNT n20 5240MHz Ant1 Duty Cycle NVNT n40 5190MHz Ant1 Report No.: N26042907906E Page 7 of 80 Duty Cycle NVNT n40 5230MHz Ant1 Maximum Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit (dBm) Verdict NVNT a 5180 Ant1 11.715 24 Pass NVNT a 5200 Ant1 12.399 24 Pass NVNT a 5240 Ant1 12.104 24 Pass NVNT ac20 5180 Ant1 12.335 24 Pass NVNT ac20 5200 Ant1 11.863 24 Pass Report No.: N26042907906E Page 8 of 80 NVNT ac20 5240 Ant1 12.134 24 Pass NVNT ac40 5190 Ant1 10.989 24 Pass NVNT ac40 5230 Ant1 12.3 24 Pass NVNT n20 5180 Ant1 12.19 24 Pass NVNT n20 5200 Ant1 11.952 24 Pass NVNT n20 5240 Ant1 12.185 24 Pass NVNT n40 5190 Ant1 10.974 24 Pass NVNT n40 5230 Ant1 11.961 24 Pass Note: The average power value already includes the duty cycle factor. -26dB Bandwidth Condition Mode Frequency (MHz) Antenna -26 dB Bandwidth (MHz) Verdict NVNT a 5180 Ant1 19.485 Pass NVNT a 5200 Ant1 19.766 Pass NVNT a 5240 Ant1 19.435 Pass NVNT ac20 5180 Ant1 19.78 Pass NVNT ac20 5200 Ant1 19.763 Pass NVNT ac20 5240 Ant1 19.66 Pass NVNT ac40 5190 Ant1 39.69 Pass NVNT ac40 5230 Ant1 41.003 Pass NVNT n20 5180 Ant1 19.811 Pass NVNT n20 5200 Ant1 19.55 Pass NVNT n20 5240 Ant1 19.829 Pass NVNT n40 5190 Ant1 39.714 Pass NVNT n40 5230 Ant1 42.14 Pass -26dB Bandwidth NVNT a 5180MHz Ant1 Report No.: N26042907906E Page 9 of 80 -26dB Bandwidth NVNT a 5200MHz Ant1 -26dB Bandwidth NVNT a 5240MHz Ant1 -26dB Bandwidth NVNT ac20 5180MHz Ant1 Report No.: N26042907906E Page 10 of 80 -26dB Bandwidth NVNT ac20 5200MHz Ant1 -26dB Bandwidth NVNT ac20 5240MHz Ant1 Report No.: N26042907906E Page 11 of 80 -26dB Bandwidth NVNT ac40 5190M…
Text truncated - open the document above for the full version.
3722 Illinois Avenue, Saint Charles, IL, 60174,USA · Saint Charles, Illinois, 60174 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 17.37 mW |
| 2 | 15E | 5.75 GHz - 5.83 GHz | 16.90 mW |