Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
LongMostInternationalCompanyLimited Address : RMS032,2/FLOORTHECAPITAL61-65CHATHAMRDSOUTHTSIMSHATSUIHK Date:2026-05-22 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BV6C-KTMSM265 FRN:0038433124 (“LongMostInternationalCompanyLimited”)certifiesthat,asofthedateofthefilingofthe application,BERDAMLLCisourdesignatedU.S.agentforserviceofprocessfortheabove referencedFCCID.(“LongMostInternationalCompanyLimited”)acceptstomaintainan agentfornolessthanoneyearafterthegranteehasterminatedallmarketingandimportation ortheconclusionofanyCommission-relatedproceedinginvolvingtheequipment. BERDAMLLCaccepts,asofthedateofthefilingoftheapplication,theobligationofthe designatedU.S.agentforserviceofprocessfortheabovereferencedFCCID. DesignatedU.S.AgentInformation: Name:BERDAMLLC Address:11016THSTSTE1400DENVERCO,CO80202UnitedStates FRN:0035972744 ContactPerson:LeonardoLei Tel.:+1-646-578-9260 Email:[email protected] Sincerely, Signedonbehalfof(LongMost InternationalCompanyLimited) SignedonbehalfofBERDAMLLC Name:EchoHongName:LeonardoLei Title:ManagerTitle:Manager Date:2026-05-22Date:2026-05-22
Rev1/26/2023 (LongMostInternationalCompanyLimited) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-05-22 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BV6C-KTMSM265 (“LongMostInternationalCompanyLimited”)certifiesthattheequipmentforwhichauthorizationis soughtisnot“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules. (“LongMostInternationalCompanyLimited”)certifiesthattheequipmentforwhichauthorizationis soughtdoesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc. oranyofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyof itssuccessorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB 986446D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):EchoHong Rev1/26/2023 (LongMostInternationalCompanyLimited) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-05-22 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BV6C-KTMSM265 (“LongMostInternationalCompanyLimited”)certifiesthat,asofthedateofthefilingoftheapplication, LongMostInternationalCompanyLimitedisnotidentifiedontheCoveredList(asaspecificallynamed entityoranyofitssubsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature): (Applicantprintedname):EchoHong
LongMostInternationalCompanyLimited Date:May22,2026 ProductModelNumber:KTM-SM156,KTM-SM101 FCCID:2BV6C-KTMSM265 Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+8613027941006 Onbehalfof:LongMostInternationalCompanyLimited
LongMostInternationalCompanyLimited OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:May25,2026 Subject;RequestforConfidentiality FCCID:2BV6C-KTMSM265 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:EchoHong Title:Manager
LongMostInternationalCompanyLimited ModelDifference Date:2026-05-22 Productdescription:SmartCalendar Modelname:KTM-SM156,KTM-SM101 FCCID:2BV6C-KTMSM265 KTM-SM156istestedmodel,othermodelsarederivativemodels.Themodelsare identicalincircuit,onlydifferentonthemodelnamesandcolors.SothetestdataofKTM- SM156canrepresenttheremainingmodels. Client’ssignature: Client’sname/title:EchoHong/Manager Contactinformation/address:RMS032,2/FLOORTHECAPITAL61-65CHATHAM RDSOUTHTSIMSHATSUIHK
LongMostInternationalCompanyLimited FCCSoftwareConfigurationControlDeclaration Date:May25,2026 FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Attn:OETDept. Product/ModelNumber:SmartCalendar/KTM-SM156 FCCID:2BV6C-KTMSM265 RegardingFCCCountryCodeSelectionguidelinesidentifiedinKDB594280. “Allapplicationsforequipmentauthorizationfortransmittersthatcanhave radioparameters,orothertechnicalparameters,reportedtotheCommission setbysoftwaremusthaveanattestationindicatingthatnothirdpartywillhave software,orconfigurationcontrol,toprogramthedeviceoutofcomplianceof thetechnicalrulesunderwhichithasbeencertified.” Wedeclarethatnothirdpartywillhavesoftware,orconfigurationcontrol,toprogram thedeviceoutofcomplianceofthetechnicalrulesunderwhichithasbeencertified. Name:EchoHongDate:May25,2026 Title:Manager Signatureofapplicant :
FCCID:2BV6C-KTMSM265 EUTPHOTOSExternalPhotos FCCID:2BV6C-KTMSM265 FCCID:2BV6C-KTMSM265 FCCID:2BV6C-KTMSM265 FCCID:2BV6C-KTMSM265 ※※※※※ENDOFREPORT※※※※※
Size:20mmX30mm FCCID:2BV6C-KTMSM265 Thisdevicecomplieswithpart15oftheFCCRules. Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation.
FCCID:2BV6C-KTMSM265 RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091, UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactof humanexposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency range (MHz) Electricfield strength (V/m) Magneticfield strength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthe totalpowerinputtotheantenna,throughthecalculation,wewillknowthedistancerwhere theMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middle andhighestchannelindividually. TestResultofRFExposureEvaluation Mode Max.Output powerto antenna (dBm) Max.Output powerto antenna (mW) Max.Power Densityat R=20cm (mW/cm2) Limit (mW/cm2) Result 2.4GWIFI 22.44175.390.05981.0PASS 5.2GWIFI 14.0224.040.00681.0PASS Remark:5.2GWIFIAntennagain=1.29dBi,2.4GWIFIAntennagain=2.34dBi Conclusion:NoRFExposureEvaluationSARtestisrequired.
ProjectNo.:ZHT-260427113W02-2 Page 1 of 42 ApplicantName...............:LongMostInternationalCompanyLimited Address............................:RMS032,2/FLOORTHECAPITAL61-65CHATHAMRDSOUTHTSIM SHATSUIHK ManufacturerName.........:I-TemptechnologyCompanyLimited Address............................:Room701No.2Building,No.11GemdaleViseenIntelligentPark,Bao LongFirstRoad,LonggangDistrict,Shenzhen Product............................:SmartCalendar Model(s)...........................:KTM-SM156 AdditionalModel(s)..........:KTM-SM101 Trademark........................:Kritem ModelDifference..............:KTM-SM156istestedmodel,othermodelsarederivativemodels.The modelsareidenticalincircuit,onlydifferentonthemodelnamesand colors.SothetestdataofKTM-SM156canrepresenttheremaining models. Preparedby......................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:Apr.27,2026 DateofTest(s)..................:Apr.27,2026toMay13,2026 DateofIssue....................:May14,2026 TestRequested................:Selecttest(s)asrequestedbytheclient. TestStandard(s)...............:FCCPart15SubpartE15.407 KDB789033D02GeneralU-NIITestProceduresNewRulesv02r01 Testprocedure..................:ANSIC63.10-2020+Cor1-2023 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. FCCTESTREPORT FCCID:2BV6C-KTMSM265 ProjectNo.:ZHT-260427113W02-2 Page 2 of 42 TableofContents Page 1.SUMMARYOFTESTRESULTS................................................................................4 2.GENERALINFORMATION........................................................................................5 2.1GENERALDESCRIPTIONOFEUT.................................................................................5 2.2DESCRIPTIONOFTESTMODES....................................................................................7 2.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED..............8 2.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE)........................................8 3.TESTFACILITYANDTESTINSTRUMENTUSED...................................................9 3.1TESTFACILITY.................................................................................................................9 3.2EQUIPMENTSLISTFORALLTESTITEMS...................................................................9 3.3TESTINGSOFTWARE....................................................................................................11 3.4MEASUREMENTUNCERTAINTY..................................................................................11 4.EMCEMISSIONTEST..............................................................................................12 4.1CONDUCTEDEMISSIONMEASUREMENT..................................................................12 4.1.1POWERLINECONDUCTEDEMISSIONLimits...................................................12 4.1.2TESTPROCEDURE...............................................................................................12 4.1.3DEVIATIONFROMTESTSTANDARD..................................................................12 4.1.4TESTSETUP...........................................................................................................12 4.1.5EUTOPERATINGCONDITIONS...........................................................................13 4.2RADIATEDEMISSIONMEASUREMENT......................................................................16 4.2.1APPLICABLESTANDARD.....................................................................................16 4.2.2CONFORMANCELIMIT.........................................................................................16 4.2.3MEASURINGINSTRUMENTS...............................................................................17 4.2.4TESTCONFIGURATION........................................................................................18 4.2.5TESTPROCEDURE...............................................................................................19 5.POWERSPECTRALDENSITYTEST......................................................................28 5.1APPLIEDPROCEDURES/LIMIT.............................................................................28 5.2TESTPROCEDURE..................................................................................................29 5.3DEVIATIONFROMSTANDARD...............................................................................29 5.4TESTSETUP..............................................................................................................29 5.5EUTOPERATIONCONDITIONS..............................................................................29 5.6TESTRESULTS.........................................................................................................30 6.26DB&6DB&99%EMISSIONBANDWIDTH........................................................31 6.1APPLIEDPROCEDURES/LIMIT.............................................................................31 6.2TESTPROCEDURE..................................................................................................31 6.3EUTOPERATIONCONDITIONS..............................................................................31 6.4TESTRESULTS.........................................................................................................31 ProjectNo.:ZHT-260427113W02-2 Page 3 of 42 TableofContents Page 7.MAXIMUMCONDUCTEDOUTPUTPOWER...........................................................32 7.1PLIEDPROCEDURES/LIMIT.........................................................…
Text truncated - open the document above for the full version.
TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City Ltd. 客户 : 悟腾/Wuteng 品 名 规 格 DESCRIPTION: EDP-1.13-L200-IPEXGeneration 1 料 PART 号 NO.: 客 户 料 号 CUS PART NO.: 日期 D A T E : 2025-7-2 云顶呈样签章 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 业务 SALESDEPARTMENT 客户承认签章 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 采购 PURCHASINGDEPARTMENT 承認 TEL:0755 23073599 ж The acknowledgement form is in three copies. Our company, Huimeng, hereby affirms and signs. ж Approval in duplicate, please signed by your company. 書 APPROVALSHEET SHENZHEN 天线 Antenna type: FPC Antenna TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 1. 测试项目与设备/Testing items and equipment 测试项目/Testing items 1.S11参数 (S-parameter 设备/Equipment ) 1.回波损耗(ReturnLoss) 2.电压驻波比(VSWR)HP8753 Network Analyzer: Agilent E5071B D 2.有源测试 (Active) 1.发射功率(TRP) 2.接收灵敏度(TIS) 1.Darkroom:ETS 7x4x3 m (3D) Chamber StarPointSP6011Cmw50 ETS 5x3x3 m (3D) Chamber 2. Comprehensive tester: Agilent 8960 E5515B ×2 0 3.无源测试 (Passive) 1.天线增益(Gain)2.天线效 率(Efficiency) 1.Darkroom:ETS 7x4x3 m (3D) Chamber HP8753 ETS 5x3x3 m (3D) Chamber 2.Network analyzer:Agilent E5071B D 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 2. 天线性能/Antenna performance SWR 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 3. 天线效率与增益/Antenna efficiency and gain PassiveTestForWIFI FreqEffiGain (MHz)(%)(dBi) 240052.681.71 241052.051.76 242050.391.71 243052.71.92 244055.752.13 245060.312.34 246061.162.26 247061.662.17 248062.542.13 249063.72.15 250064.072.23 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N PassiveTestForWIFI5.8 FreqEffiGain (MHz)(%)(dBi) 515057.651.29 520052.360.76 525046.790.16 530049.360.4 535058.051.13 540065.741.8 545058.961.53 550060.611.74 555063.452.28 560060.142.21 565056.982.02 570056.921.78 575059.282.02 580054.711.05 585047.40.66 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 4. 天线结构图/Antenna structure diagram: 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City Unit: mm TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 电器技术参数/Electrical technical parameters 电 性 能 指 标/ ElectricalSpecifications 频率范围2400~2500/5150~5850HzFrequencyRange2400~2500/5150~5850Hz 电压驻波比≤2.0VSWR≤2.0 输入阻抗50ΩInputImpedance50Ω 增益Gai2.34dBi Maxn2.34dBi Max 机械指标 MechanicalSpecifications 线材颜色黑色WirecolorBlack 接口形式IPEX一代InputconnectorIPEX1 天线线长200mmCablelength200mm 工作温度-40°C~+85°CWorkingTemperature-40°C~+85°C 工作湿度20~80%WorkingHumidity20~80% 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 环境性能测试( Environmentperformancetest ) : 项目测试条件测试结果 储存环境 在没有指定的情况下测试温度、湿度、气压如下: 1.温度为-30°C~+80°C 2.相对湿度为45%-85% 3.气压为86kpa-106kpa 电气机械性能正常 高低温试验 在70°C与-40°C之间进行5次循环,然后在正常条件下 1-2H,检查外观质量。 尺寸应满足规定并应 满足 于机械、电气性能 耐恒定湿热 试验 相对湿度95±3%,试验温度:40°C.持续2H作用后, 试品取出后5min之内测定电气性能,试品在正常条 件下1-2H,检查外观质量 尺寸应满足规定并应 满足 于机械、电气性能 振动试验 振频范围10-55HZ,位移幅值:0.35MM,加速度幅值: 50.0M/S,扫频循环次数:30次 电气机械性能正常 跌落试验1M高空按照互相垂直的轴方向自由跌落3次电气机械性能正常 ProjectTestconditionTestresults Storage environment Testtemperature,humidity,pressurewithout statedconditionasfollwings:1.Temperature:-30°C~ +80°C;2.Relativehumidity:45%-85%;3,Pressure: 86kpa-106kpa Electricaland mechanical performancenormal Highandlow temperaturetest Having5timescyclebetween-40°Cto70°C,Thenincommon condition1-2hourstestexteriorquality. Measurement satisfiedwith electricaland mechanical performancenormal. Resistance constanthotand humidtest Relativehumidity:95±3%,Testtemperature:40°C,last2 hours,putitafter5mintesttheelectricalfunction.Test productsduringcommoncondition1-2hours,Thentest exteriorquality. Measurement satisfiedwith electricaland mechanical performancenormal. Vibrationtest VibrateFrequency:10-55HZ; Distance:0.35mm;Acceleration:50.0m/s;Sweepfrequency cycle:30times Electricaland mechanical performancenormal FalltestFrom1mheightfalldown3timesfreely(verticaldirection) Electricaland mechanical performancenormal 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City
FCCID:2BV6C-KTMSM265Page1of48 AppendixAfor5.2GWIFITestData ProductName:SmartCalendar TestModel:KTM-SM156 EnvironmentalConditions Temperature: 25.7°C RelativeHumidity:54.9% ATMPressure:101.0kPa TestEngineer:LeonLi Supervisedby:BaretWu FCCID:2BV6C-KTMSM265Page2of48 DutyCycle ModeFrequency(MHz)AntennaT on ms T otal ms DutyCycle(%)Correction Factor(dB) 1/T (kHz) a5180Ant12.042.2690.270.440.49 a5200Ant12.042.1395.770.190.49 a5240Ant12.032.1196.210.170.49 n205180Ant11.891.9795.940.180.53 n205200Ant11.891.9696.430.160.53 n205240Ant11.891.9296.430.160.53 n405190Ant10.931.0786.920.611.08 n405230Ant10.931.0489.420.491.08 ac205180Ant11.902.1190.050.460.53 ac205200Ant11.902.1190.050.460.53 ac205240Ant11.902.0194.530.240.53 ac405190Ant10.941.1681.030.911.06 ac405230Ant10.941.0787.850.561.06 Note: 1.DutyCycle=T on /T otal 2.CorrectionFactor=10log(1/DutyCycle). 3.1/T=1/T on FCCID:2BV6C-KTMSM265Page3of48 TestGraphs DutyCycleNVNTa5180MHzAnt1 DutyCycleNVNTa5200MHzAnt1 FCCID:2BV6C-KTMSM265Page4of48 DutyCycleNVNTa5240MHzAnt1 DutyCycleNVNTn205180MHzAnt1 FCCID:2BV6C-KTMSM265Page5of48 DutyCycleNVNTn205200MHzAnt1 DutyCycleNVNTn205240MHzAnt1 FCCID:2BV6C-KTMSM265Page6of48 DutyCycleNVNTn405190MHzAnt1 DutyCycleNVNTn405230MHzAnt1 FCCID:2BV6C-KTMSM265Page7of48 DutyCycleNVNTac205180MHzAnt1 DutyCycleNVNTac205200MHzAnt1 FCCID:2BV6C-KTMSM265Page8of48 DutyCycleNVNTac205240MHzAnt1 DutyCycleNVNTac405190MHzAnt1 FCCID:2BV6C-KTMSM265Page9of48 DutyCycleNVNTac405230MHzAnt1 FCCID:2BV6C-KTMSM265Page10of48 MaximumConductedOutputPower ConditionModeFrequency (MHz) AntennaConducted Power(dBm) Duty Factor (dB) TotalPower (dBm) Limit (dBm) Verdict NVNTa5180Ant112.660.4413.124Pass NVNTa5200Ant113.630.1913.8224Pass NVNTa5240Ant113.810.1713.9824Pass NVNTn205180Ant112.90.1813.0824Pass NVNTn205200Ant113.480.1613.6424Pass NVNTn205240Ant113.640.1613.824Pass NVNTn405190Ant112.720.6113.3324Pass NVNTn405230Ant113.230.4913.7224Pass NVNTac205180Ant112.870.4613.3324Pass NVNTac205200Ant113.380.4613.8424Pass NVNTac205240Ant113.780.2414.0224Pass NVNTac405190Ant112.810.8813.6924Pass NVNTac405230Ant113.36013.3624Pass FCCID:2BV6C-KTMSM265Page11of48 TestGraphs PowerNVNTa5180MHzAnt1 PowerNVNTa5200MHzAnt1 FCCID:2BV6C-KTMSM265Page12of48 PowerNVNTa5240MHzAnt1 PowerNVNTn205180MHzAnt1 FCCID:2BV6C-KTMSM265Page13of48 PowerNVNTn205200MHzAnt1 PowerNVNTn205240MHzAnt1 FCCID:2BV6C-KTMSM265Page14of48 PowerNVNTn405190MHzAnt1 PowerNVNTn405230MHzAnt1 FCCID:2BV6C-KTMSM265Page15of48 PowerNVNTac205180MHzAnt1 PowerNVNTac205200MHzAnt1 FCCID:2BV6C-KTMSM265Page16of48 PowerNVNTac205240MHzAnt1 PowerNVNTac405190MHzAnt1 FCCID:2BV6C-KTMSM265Page17of48 PowerNVNTac405230MHzAnt1 FCCID:2BV6C-KTMSM265Page18of48 -26dBBandwidth&OccupiedChannelBandwidth ConditionModeFrequency(MHz)Antenna-26dBBandwidth(MHz)99%OBW(MHz)Verdict NVNTa5180Ant129.4216.681Pass NVNTa5200Ant125.816.669Pass NVNTa5240Ant127.5816.703Pass NVNTn205180Ant127.3117.847Pass NVNTn205200Ant126.8317.826Pass NVNTn205240Ant127.4717.873Pass NVNTn405190Ant146.7536.428Pass NVNTn405230Ant146.4036.475Pass NVNTac205180Ant126.7317.865Pass NVNTac205200Ant126.2117.824Pass NVNTac205240Ant127.6217.866Pass NVNTac405190Ant155.8536.501Pass NVNTac405230Ant155.4736.444Pass FCCID:2BV6C-KTMSM265Page19of48 TestGraphs OBWNVNTa5180MHzAnt1 OBWNVNTa5200MHzAnt1 FCCID:2BV6C-KTMSM265Page20of48 OBWNVNTa5240MHzAnt1 OBWNVNTn205180MHzAnt1 FCCID:2BV6C-KTMSM265Page21of48 OBWNVNTn205200MHzAnt1 OBWNVNTn205240MHzAnt1 FCCID:2BV6C-KTMSM265Page22of48 OBWNVNTn405190MHzAnt1 OBWNVNTn405230MHzAnt1 FCCID:2BV6C-KTMSM265Page23of48 OBWNVNTac205180MHzAnt1 OBWNVNTac205200MHzAnt1 FCCID:2BV6C-KTMSM265Page24of48 OBWNVNTac205240MHzAnt1 OBWNVNTac405190MHzAnt1 FCCID:2BV6C-KTMSM265Page25of48 OBWNVNTac405230MHzAnt1 FCCID:2BV6C-KTMSM265Page26of48 MaximumPowerSpectralDensityLevel ConditionModeFrequency (MHz) AntennaConductedPSD (dBm) Duty Factor(dB) TotalPSD (dBm) Limit (dBm) Verdict NVNTa5180Ant12.230.442.6711Pass NVNTa5200Ant13.630.193.8211Pass NVNTa5240Ant13.810.173.9811Pass NVNTn205180Ant12.550.182.7311Pass NVNTn205200Ant12.890.163.0511Pass NVNTn205240Ant13.30.163.4611Pass NVNTn405190Ant1-1.140.61-0.5311Pass NVNTn405230Ant1-0.20.490.2911Pass NVNTac205180Ant12.270.462.7311Pass NVNTac205200Ant12.850.463.3111Pass NVNTac205240Ant13.490.243.7311Pass NVNTac405190Ant1-1.40.88-0.5211Pass NVNTac405230Ant1-0.230-0.2311Pass FCCID:2BV6C-KTMSM265Page27of48 TestGraphs PSDNVNTa5180MHzAnt1 PSDNVNTa5200MHzAnt1 FCCID:2BV6C-KTMSM265Page28of48 PSDNVNTa5240MHzAnt1 PSDNVNTn205180MHzAnt1 FCCID:2BV6C-KTMSM265Page29of48 PSDNVNTn205200MHzAnt1 PSDNVNTn205240MHzAnt1 FCCID:2BV6C-KTMSM265Page30of48 PSDNVNTn405190MHzAnt1 PSDNVNTn405230MHzAnt1 FCCID:2BV6C-KTMSM265Page31of48 PSDNVNTac205180MHzAnt1 PSDNVNTac205200MHzAnt1 FCCID:2BV6C-KTMSM265Page32of48 PSDNVNTac205240MHzAnt1 PSDNVNTac405190MHzAnt1 FCCID:2BV6C-KTMSM265Page33of48 PSDNVNTac405230MHzAnt1 FCCID:2BV6C-KTMSM265Page34of48 BandEdge ConditionModeFrequency(MHz)AntennaMaxValue(dBm/MHz)Limit(dBm/MHz)Verdict NVNTa5180Ant1-31.59-27Pass NVNTa5240Ant1-46.88-27Pass NVNTn205180Ant1-28.18-27Pass NVNTn205240Ant1-45.85-27Pass NVNTn405190Ant1-31.43-27Pass NVNTn405230Ant1-43.72-27Pass NVNTac205180Ant1-28.81-27Pass NVNTac205240Ant1-46.59-27Pass NVNTac405190Ant1-31.32-27Pass NVNTac405230Ant1-43.23-27Pass FCCID:2BV6C-KTMSM265Page35of48 TestGraphs BandEdgeNVNTa5180MHzLowAnt1 BandEdgeNVNTa5240MHzHighAnt1 FCCID:2BV6C-KTMSM265Page36of48 BandEdgeNVNTn205180MHzLowAnt1 BandEdgeNVNTn205240MHzHighAnt1 FCCID:2BV6C-KTMSM265Page37of48 BandEdgeNVNTn405190MHzLowAnt1 BandEdgeNVNTn405230MHzHighAnt1 FCCID:2BV6C-KTMSM265Page38of48 BandEdgeNVNTac205180MHzLowAnt1 BandEdgeNVNTac205240MHzHighAnt1 FCCID:2BV6C-KTMSM265Page39of48 BandEdgeNVNTac405190MHzLowAnt1 BandEdgeNVNTac405230MHzHighAnt1 FCCID:2BV6C-KTMSM265Page40of48 FrequencyStability Voltage Test Mode Channel Voltage [Vdc] Temperature (°C) MeasuredFrequency (MHz) Limit (MHz) Verdict a5180 NVNT5180.02 Within 5150-5250MHz PassLVNT5180.03 HVNT5180.01 Temperature Test Mode Channel Voltage [Vdc] Temperature (°C) MeasuredFrequency (MHz) Limit (MHz) Verd…
Text truncated - open the document above for the full version.
FCCID:2BV6C-KTMSM265 EUTTESTPHOTOS FCCID:2BV6C-KTMSM265 ※※※※※ENDOFREPORT※※※※※
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.18 GHz - 5.24 GHz | 25.20 mW |