INS TRUCTION MANU AL ——Please read this manual carefully before using this product and ke ep it for future reference—— Instruct io ns Bef oreUse 1. Whe n tur ni ng on the spr ay func tion, pl ease make sur e tha t the re is enoughwater in the tank to avoi d dr y bur ni ng and cons eque nt ly caus ing ins trum ent failur e. 2. If the re is any di scom for t in the ski n or eyes dur ing us e, pl ease stop us ing immedi ately. 3. Thi s pr oduc t is ne ithe r a subs titut e for medi cal equi pm ent nor for the rape ut ic us e. 4. Please adj us t the appr opr iate leng th and freque nc y of us e accor di ng to your ow n state. 5. Do not wear cont act len ses dur ing us e. 6. Please do not us e thi s pr oduc t with make up on, or your make up may run. 7. Please do not us e the pr oduc t in the fol low ing situa tions : Whe n feeling sick or ha vi ng a feve r; The re are wounds, eczema, or swelling on the ski n; Ski n abnor malities suc h as de rmatitis or excessive sunburns 8. The fol low ing pe opl e shoul d not us e thi s pr oduc t: Thos e with allergi es or facial ski n sens itivi ties; Thos e with eye di seases, eye inf lammation, swelling , inj ur y, eczema, catar act, glauc om a, retina l de tachm ent and ot he r abnor malities; Thos e with facial ne rve di sor de rs or ski n sens or y di sor de rs; Thos e with hi gh myopi a (greater tha n -6 D); Pregna nt wom en; Thos e who ha ve or ha ve ha d eye di seases, or ha d eye sur gery resul ting in tempe ratur e sens itivi ty or retarda tion, or are unde rgoi ng eye treatment s. Our company is notbe liable forany problems due to fai lure to fol lowthe InstructionManual . Cautio ns for Use * Frequen cyof use Use as ne ede d with 15 minut es pe r us e. It is advi sed to rest for a whi le after one us e be for e us ing it aga in. * Cauti ons BeforeUse Whe n us ing thi s pr oduc t, pl ease adj us t to your pe rsona l com for tabl e pos ition to allow your bodyto com pl etely relax. Stop us ing if your ski n be com es sor e or you feel unc om for tabl e. * Clea ning of th e Pro duct 1. Whe n cleani ng the pr oduc t, pl ease make sur e tha t it is tur ne d of f withoutcha rgi ng; 2. If its appe aranc e ne eds to be cleane d, us e a dr y clot h with water to wipe the pol ishe d sur face and the n let it dr y na tur ally; 3. The main uni t cannotbe washe d with water. Do not us e water to rins e its body . The spr aying por t and water tank inl et can be wipe d gent ly with a cot ton swab. 4. Whe n the pr oduc t is not to be us ed for a long time, clean and dr y its bodyand com pone nt s and pl ace the m in a cool and dr y pl ace. Avoi d d irect sunl ight and ke ep away from he ating de vi ces and ope n flames. * Sta tus after Use After us ing , empt y the liqui d in the tank and ke ep the tank clean. Avoi d leavi ng the tank for a long time whe n the re is liqui d in it. Pro ductIntro duct io n Pro ductPara meters [Produc t Name] Smart Eye Massage r [Produc t Mode l] W6 [Rated Vol tage ] 5V [Rated Pow er] 5W [Smart Timer] 15m in [Massage Mode ] Vibr ation massage , eye moi stur izing spr ay, and eye warming the rmal mist Loos en/ Tighten the Strap Water Fill Por t Func tion Indicator Lights Charging Por t Lon g Press: On/ Off Shor t Press: Switch Mod e Dou ble Click: Off the Music Opera tin g Instruct io ns [Water Filling] 1. Add mine ral water or tap water int o the com pl iment ary small mout h bot tle; 2. Ope n the sof t rubbe r pl ug at the filling por t of the water tank upw ards , fill with the right amountof mine ral water or tap water with the small mout h bot tle, and the n fasten the pl ug . Not e: The wat er tank should notbe overfilled eac h time. Mode Description Ene rgi zing Mode : The rmal mist + Eye moi stur izing spr ay (large amount ) + Vibr ation massage + Soot hi ng m us ic Eye Exe rcises Mode : Vibr ation massage + Soot hi ng mus ic Soot hi ng Mode : The rmal mist + Eye moi stur izing spr ay (cont inuousspr ay) + Soot hi ng mus ic Sleep Mode : Vibr ation massage + Soot hi ng mus ic Steps forUse 1. Adj us t the strap to the appr opr iate pos ition, and wear the massager cor rectly to start us ing ; Not e: If the re is too little water in the tank, to avoi d dr y bur ni ng caus ed by ins trum ent failur e, do not lie dow n to us e; 2. Long pr ess for 2 seconds , and the ins trum ent will spe ak “Welcom e to us e thi s eye massage r, and pl ease select the mode ”, and the n pr ess the but ton aga in to ent er the ene rgi zing mode . Shor t pr ess to ent er the ne xt mode . The re are 4 mode s tha t can be switche d (for de tails, pl ease refer to the Mode Descript ion) ; 3. The massage r will be aut om atically tur ne d of f after 15 minut es of us e. Please remove the residua l water in the tank and dr y the ins trum ent , and the n pl ace it in a cool and dr y pl ace. * Press the button twice to turn of f/onthe music. * If youneed to stopduring using,long press the button for2 seconds to turn of f the instrument. Not e: Bluetooth will be aut om atically turne d on after the host is started, and you can just open your cell phone ’s Bluetoo th and search for the Bluetooth name “YBY” to connect. Charg in g Descriptio n Whe n the ins trum ent spe aks in a low ba ttery tone of “Low ba ttery, pl ease cha rge ”, pl ease cha rge in time to avoi d affecting the nor mal us e. Thi s pr oduc t us es recha rge abl e lithi um ba tteries, and the indi cator light will show“Red” whe n cha rgi ng , and “green” whe n the cha rgi ng is com pl eted. Please us e the pow er ada pt er meeting the rated vol tage (5V =1A ) of thi s pr oduc t to cha rge , and do not tur n on the pow er whe n cha rgi ng and do not put it ne ar ope n flame or he at it . Precautio ns 1. Stor e the pr oduc t out of the reach of inf ant s and chi ldr en. 2. Do not us e the pr oduc t in the ba thr oom . 3. Do not modi fy or repa ir the pr oduc t pr iva tely. 4. If any of the fol low ing malfunc tions oc cur s, pl ease stop us ing immedi ately and di sconne ct the pow er suppl y…
Text truncated - open the document above for the full version.
ShenZhenShisenYHongKiJiYouxianGongsie Unit 5A, Building C, Jingguang Haizhijuan Garden Tower, Xingnan Road, YuehaiStreet, Nanshan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/03/25 U.S. Agent Designation ShenZhenShisenYHongKiJiYouxianGongsie acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BVDZ-SHYY-001): Name and company of U.S. agent: GLOCERTS TECHNOLOGY INC Physical U.S. address of agent: 19784 SUNKISSED RIDGE DR RIVERSIDE, CA 92507 United States FRN of U.S. agent: 0036339737 Phone of U.S. agent: (626) 588-8039 Email address of U.S. agent: [email protected] GLOCERTS TECHNOLOGY INC acknowledges their obligation to accept service of process on behalf of ShenZhenShisenYHongKiJiYouxianGongsie with the FRN [0038203287] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature Dandan Zhuang Manager ShenZhenShisenYHongKiJiYouxianGongsie Signature Huiying Fan Director GLOCERTS TECHNOLOGY INC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID: 2BVDZ-SHYY-001 External Photos of the EUT FCC ID: 2BVDZ-SHYY-001 FCC ID: 2BVDZ-SHYY-001
Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID : 2BVDZ-SHYY-001
FCC ID: 2BVDZ-SHYY-001 Internal Photos of the EUT FCC ID: 2BVDZ-SHYY-001 FCC ID: 2BVDZ-SHYY-001 FCC ID: 2BVDZ-SHYY-001 ANT
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure evaluation Report Reference No. ..................... : FCC ID............................................. : CTA26022700602 2BVDZ-SHYY-001 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : Mar. 06, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : ShenZhenShisenYHongKiJiYouxianGongsie Address............................................ : Unit 5A, Building C, Jingguang Haizhijuan Garden Tower, Xingnan Road, YuehaiStreet, Nanshan District, Shenzhen, China Standard ........................................... : 47CFR §1.1310 47CFR §2.1093 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : Eye Massager Trade Mark ....................................... : N/A Manufacturer .................................... : Shenzhen Qianbaiyou Technology Co., LTD Model/Type reference ...................... : SHYY-001 Listed Models ................................... : N/A Rating ............................................... : DC 3.7V From battery and DC 5.0V From external circuit Result ............................................... : PASS Report No.: CTA26022700602 Page 2 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Eye Massager Model /Type : SHYY-001 Listed Models : N/A Applicant : ShenZhenShisenYHongKiJiYouxianGongsie Address : Unit 5A, Building C, Jingguang Haizhijuan Garden Tower, Xingnan Road, YuehaiStreet, Nanshan District, Shenzhen, China Manufacturer : Shenzhen Qianbaiyou Technology Co., LTD Address : Room B335, No. 142, Songyu Road, Hongxing Community,Songgang Subdistrict, Bao'an District, Shenzhen City, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26022700602 Page 3 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks .................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................ 5 2.4 Modifications ........................................................................................................... 5 3 TEST ENVIRONMENT ....................................................................................................... 6 3.1 Address of the test laboratory ................................................................................. 6 3.2 Test Facility ............................................................................................................. 6 3.3 Statement of the measurement uncertainty ............................................................ 6 4 Test limit .............................................................................................................................. 7 4.1 Requirement ........................................................................................................... 7 4.2 Conducted Power Results ...................................................................................... 7 4.3 Manufacturing tolerance ......................................................................................... 7 4.4 Evaluation Result .................................................................................................... 8 4.5 Simultaneous Transmission for SAR Exclusion ..................................................... 8 5 Conclusion ........................................................................................................................... 8 Report No.: CTA26022700602 Page 4 of 8 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www…
Text truncated - open the document above for the full version.
ANT 1、manufacturer: Manufacturer:ClouldhealthelectronicsCo.,Ltd. materialquality:PCBANT model:YK_ANT Companyaddress:The4thFloor,Building28,AreaA,TheFirstIndustrialZone, GongheCommunity,ShajingStreet,BaoanDistrict,ShenzhenCity 2、AntennaPhoto&Length(mm) 3、Data 3.1、3D 2400MHz: 2450MHz: 2500MHz 3.2、2D 3.3、Detaileddata Summary ITEMANTSPEC ModelName2.4GANT AntennaplatePCBantenna MAX.Gain2.6dBi PolarizationHorizontalandVertical Impedance50Ohm Manufacture
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA26022700601 2BVDZ-SHYY-001 Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: Mar. 06, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ..........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: ShenZhenShisenYHongKiJiYouxianGongsie Address ...........................................: Unit 5A, Building C, Jingguang Haizhijuan Garden Tower, Xingnan Road, YuehaiStreet, Nanshan District, Shenzhen, China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : Eye Massager Trade Mark ......................................: N/A Manufacturer ...................................: Shenzhen Qianbaiyou Technology Co., LTD Model/Type reference .....................: SHYY-001 Listed Models ..................................: N/A Modulation ......................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: DC 3.7V From battery and DC 5.0V From external circuit Result ..............................................: PASS Report No.: CTA26022700601 Page 2 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : Eye Massager Model /Type : SHYY-001 Listed Models : N/A Applicant : ShenZhenShisenYHongKiJiYouxianGongsie Address : Unit 5A, Building C, Jingguang Haizhijuan Garden Tower, Xingnan Road, YuehaiStreet, Nanshan District, Shenzhen, China Manufacturer : Shenzhen Qianbaiyou Technology Co., LTD Address : Room B335, No. 142, Songyu Road, Hongxing Community,Songgang Subdistrict, Bao'an District, Shenzhen City, China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26022700601 Page 3 of 36 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* ......................................................................................................................... 5 2.3 Equipment Under Test ...................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ..................................................................... 5 2.5 EUT configuration ............................................................................................................................. 5 2.6 EUT operation mode ........................................................................................................................ 5 2.7 Block Diagram of Test Setup ............................................................................................................ 6 2.8 Related Submittal(s) / Grant (s) ........................................................................................................ 6 2.9 Modifications ..................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory ........................................................................................................... 7 3.2 Test Facility ....................................................................................................................................... 7 3.3 Environmental conditions ................................................................................................................. 7 3.4 Summary of measurement results ......…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BLE FCC ID : 2BVDZ-SHYY-001 Company : ShenZhenShisenYHongKiJiYouxianGongsie EUT : Eye Massager Model Number : SHYY-001 Report No. : CTA26022700601 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result TestMode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.644 2401.692 2402.336 0.5 PASS 2440 0.636 2439.696 2440.332 0.5 PASS 2480 0.632 2479.700 2480.332 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0153 2401.5161 2402.5314 --- --- 2440 1.0142 2439.5160 2440.5302 --- --- 2480 1.0126 2479.5155 2480.5281 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result Peak TestMode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -3.46 ≤30 PASS 2440 -3.80 ≤30 PASS 2480 -3.87 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result TestMode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -19.41 ≤8.00 PASS 2440 -19.78 ≤8.00 PASS 2480 -19.76 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result TestMode Antenna ChName Freq(MHz) RefLevel[dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 Low 2402 -4.66 -55.59 ≤-24.66 PASS High 2480 -3.87 -57.74 ≤-23.87 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -5.65 -5.65 --- PASS 30~1000 -5.65 -34 ≤-25.65 PASS 1000~26500 -5.65 -46.27 ≤-25.65 PASS 2440 Reference -4.50 -4.50 --- PASS 30~1000 -4.50 -38.72 ≤-24.5 PASS 1000~26500 -4.50 -48.73 ≤-24.5 PASS 2480 Reference -4.26 -4.26 --- PASS 30~1000 -4.26 -38.96 ≤-24.26 PASS 1000~26500 -4.26 -50.3 ≤-24.26 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21 22 Appendix H: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -59.99 2.6 1.80 39.61 ≤54 PASS AV 2366.990 -58.79 2.6 1.80 40.81 ≤54 PASS AV 2390.000 -59.33 2.6 1.80 40.27 ≤54 PASS Peak 2310.000 -51.17 2.6 0.00 46.63 ≤74 PASS Peak 2352.080 -48.51 2.6 0.00 49.29 ≤74 PASS Peak 2390.000 -50.56 2.6 0.00 47.24 ≤74 PASS High 2480 AV 2483.500 -58.37 2.6 1.80 41.23 ≤54 PASS AV 2484.880 -58.12 2.6 1.80 41.48 ≤54 PASS AV 2500.000 -59.53 2.6 1.80 40.07 ≤54 PASS Peak 2483.500 -48.46 2.6 0.00 49.34 ≤74 PASS Peak 2483.520 -48.46 2.6 0.00 49.34 ≤74 PASS Peak 2500.000 -49.56 2.6 0.00 48.24 ≤74 PASS Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 23 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV 24 BLE_1M_Ant1_High_2480_Peak
FCC ID: 2BVDZ-SHYY-001 Test Setup Photos of the EUT FCC ID: 2BVDZ-SHYY-001
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 500.00 µW |