Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467
Product:coziwow Pet Camera mini1 Model: CWP0467 Input: DC5V, 1A FCCID:2BVEG-CWP0467 Manufacturer: Shenzhen Smartrol Technology Co.,Ltd
Label Location
FCC ID: 2BVEG-CWP0467 Antenna FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467 FCC ID: 2BVEG-CWP0467
SAR evaluation FCC ID: 2BVEG-CWP0467 MPE Calculation Method E (V/m) = (30*P*G) 0.5 /d Power Density: Pd (W/m2) = E 2 /377 E = Electric Field (V/m) P = Peak RF output Power (W) G = EUT Antenna numeric gain (numeric) d = Separation distance between radiator and human body (m) The formula can be changed to Pd = (30*P*G) / (377*d 2 ) From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of the used antenna, the RF power density can be obtained. Calculated WIFI Result and Limit (WORSE CASE IS AS BELOW) Antenna Gain (Numeric) Peak Output Power (mW) Power Density (S) (mW/cm2) Limit of Power Density (S) (mW/cm2) Test Result 1.88 7.10 0.002655 1 Compiles Note: Antenna Gain: 2.74dBi (2.4G Band) Assembly Antenna Gain (Numeric): 1.88dBi ERP=8.51+2.74-2.15=9.1dBm(8.128mW) Calculated Bluetooth Result and Limit (WORSE CASE IS AS BELOW) eirp = pt x gt = (EXd) 2 /30 where: pt = transmitter output power in watts, gt = numeric gain of the transmitting antenna (unitless), E = electric field strength in V/m, --- 10 ((dBuV/m)/20) /10 6 d = measurement distance in meters (m)---3m So pt = (EXd) 2 /(30 x gt) Ant gain =2.74dBi so Ant numeric gain= 1.88 Field strength =91.90dBμV/m @3m@2440MHz So Pt={[10 (91.90/20) /10 6 x3] 2 /(30x1.88)}x1000 mW = 0.25mW Antenna Gain (Numeric) Peak Output Power (mW) Power Density (S) (mW/cm2) Limit of Power Density (S) (mW/cm2) Test Result 1.88 0.25 0.000094 1 Compiles Note: Antenna Gain: 2.74dBi (2.4G Band) Assembly Antenna Gain (Numeric): 1.88dBi ERP=-6.02+2.74-2.15=-5.43 dBm(0.286mW) BT BDR/EDR and BLE cannot transmit Simultaneously =7.10/3060 +0.25/3060=0.002402 = (8.128+0.286)/3060 =0.002750 =( 0.002655+ 0.000094)/1=0.002749 0.002402+0.002750+0.002749=0.007901<1
Report No.: TW2602003-01E Applicant: JAXPETY CORP Product: coziwow Pet Camera mini1 Model No.: CWP0467, CW12U0860, CW12E0866 Trademark: N/A Test Standards: FCC Part 15.247 Test Result: It is herewith confirmed and found to comply with the requirements set up by ANSI C63.10, FCC Part 15.247 for the evaluation of electromagnetic compatibility Approved By Terry Tang Manager Dated: March 16, 2026 Results appearing herein relate only to the sample tested The technical reports is issued errors and omissions exempt and is subject to withdrawal at SHENZHEN TIMEWAY TESTING LABORATORIES Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China Tel (755) 83448688, Fax (755) 83442996, E-Mail:[email protected] Report No.: TW2602003-01E Page 2 of 120 Date: 2026-03-13 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Special Statement: FCC-Registration No.: 744189 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. The acceptance letter from the FCC is maintained in our files. Registration No.: 744189. ISED —Registration No.:5205A The EMC Laboratory has been registered by Certification and Engineering Bureau of ISED for radio equipment testing with Registration No.: 5205A. A2LA (Certification Number:5013.01) The EMC Laboratory has been accredited by the American Association for Laboratory Accreditation (A2LA). Certification Number:5013.01 CAB identifier: CN0033 FCC Designation Number: CN1251 Report No.: TW2602003-01E Page 3 of 120 Date: 2026-03-13 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. Test Report Conclusion Content 1.0 General Details................................................................................................. 4 1.1 Test Lab Details................................................................................................ 4 1.2 Applicant Details............................................................................................... 4 1.3 Description of EUT ........................................................................................... 4 1.4 Submitted Sample.............................................................................................. 5 1.5 Test Duration................................................................................................... 5 1.6 Test Uncertainty............................................................................................... 5 1.7 Test By.......................................................................................................... 5 2.0 List of Measurement Equipment.......................................................................... 6 3.0 Technical Details............................................................................................. 8 3.1 Summary of Test Results..................................................................................... 8 3.2 Test Standards.................................................................................................. 8 4.0 EUT Modification............................................................................................ 8 5.0 Power Line Conducted Emission Test................................................................... 9 5.1 Schematics of the Test........................................................................................ 9 5.2 Test Method and Test Procedure............................................................................ 9 5.3 Configuration of the EUT.................................................................................... 9 5.4 EUT Operating Condition....................................................................................10 5.5 Conducted Emission Limit................................................................................... 10 5.6 Test Result...................................................................................................... 10 6.0 Radiated Emission test...................................................................................... 13 6.1 Test Method and Test Procedure............................................................................ 13 6.2 Configuration of the EUT.............................…
Text truncated - open the document above for the full version.
中讯智控样品承认书 文件编号(FILES NO.): 版本编码(REV. ): 物料名称(PART NAME): FPC 2.4G天线 规格型号(PART NO.): YCX08N-1642-90B内置FPC 2.4G天线 黑色1.13线 长90mm带端子 物料编码(PART NO.): 3.02.00090-001 供应商(SUPPLIER):源创星电子(深圳)有限公司 签名 /日期(SIGNATURE / DATE ): 客户承认会签供应商技术发行 核准品质工程采购核准审核技术 Zouyc 王 俊 许军波 源创星电子(深圳)有限公司 Yuanchuangxing electronics (Shenzhen)CO.,LTD. Customer Name: Customer Moder: Customer P/N: Customer Describe : YCX P/N: Customer Describe : Signature and seal of confirmation YCX Approved Customer Approved Sampleaudit approved validation audit approved YCX Approved ByCustomer Approved By DateDate 中讯智控 PRODUCT SPECIFICATION YCX08N-1642-90B 内置FPC 2.4G天线黑色1.13线 长90mm带端子 3.02.00090-001 zouyc 源创星签字盖单 2024-12-232024-12-23 王俊 许军波 源创星电子(深圳)有限公司 Yuanchuangxing electronics (Shenzhen)CO.,LTD. 3、Directory 1、directory..................................................1 2、File for amendment/revocation/resume.......................2 3、directory..................................................3 4、Product drawings...........................................4 5、Passive performance test paramete........................5 6、2D、3D Performance figure..................................6 7、Electrical performance test report.........................7 源创星电子(深圳)有限公司 Yuanchuangxing electronics (Shenzhen)CO.,LTD. 4 、 Product drawings 8 NO. PART OR IDENTIFYING NO. 6 7 NOMENCLATURE OR DESCRIPTION 4 5 MATERIAL AS DIMENSION A B TOLERANCE C D 7 6 5 4 2 3 CAD FILE: SCALE : 1 : 1 1 3 2 1 A B C D QTY PART NO.: TITLE: DWG TYPE: UNIT .XXX ±0.05 .XX ±0.1 .X ±0.2 X. ±0.25 XX. ±1 XXX. ±2 CHANGE DESCRIPTION SIGNATURE DATE REV. PRODUCT DRAWING UNIT mm DRAWED BY CHECKED BY APPROVED BY zyc Mike Sky 源创星电子(深圳)有限公司 Yuanchuangxing electronics (Shenzhen)CO.,LTD. www.yuanchuangxing.cn www.yuanchuangxing.cn A1 New 202 4 . 12 . 13 zyc Technical requirements: 1. Electrical parameters: 1.1 Impedance 1.2 Frequency 1.3 VSWR 1.4 Peak Gain 1.5 Polarization : 50Ω : 2400-2500MHz : < 2.0 : 2.74 dBi MAX : Linear 1.6 Radiation Patten: Omni directional 2. Mechanical properties: 2.1 Storage Temperature Range: -40 TO +85°C2.2 Operating Temperature Range: -40 TO +85°C 3. All material must meet ROHS request 4. Mark( )as the key control dimensions cable connect Black 1.13 Black IPEX 1 1 11 31,8±0.2 10±0.2 80±3 Y08N-FPC146A YCX08N-1642-90B 内 置 2.4 G FPC天 线 黑色1.13 线 90mm 带 端子 源创星电子(深圳)有限公司 Yuanchuangxing electronics (Shenzhen)CO.,LTD. 5、Passive performance test parameters Frequency(GHz)2.42.452.5 VSWR 1.66 1. 35 1.46 5.15 5.55 5.85 源创星电子(深圳)有限公司 Yuanchuangxing electronics (Shenzhen)CO.,LTD. 6、2D、3D Performance figure Passive Test For WiFi Freq (MHz) Effi (%) Gain (dBi) 2400 60 2.65 2450 61 2.74 2500 62 2. 73 源创星电子(深圳)有限公司 Yuanchuangxing electronics (Shenzhen)CO.,LTD. 7、Electrical performance test report Electrical parameters Frequency range 2.4-2.5GHz&&5.15-5.85GHz input impedance 50Ω VSWR <2.0 Gain 2.74dBi MAX Polarization mode Linear polarization Radiation direction omnidirectional connection method Mechanical parameters Cable Salt spray test Environmental parameters Working temperature -40~85°C IPEX 1.13
FCC ID: 2BVEG-CWP0467 Conducted Emission Test Setup: FCC ID: 2BVEG-CWP0467 Radiated Emission Test Setup: FCC ID: 2BVEG-CWP0467 RF test Setup:
904 S 2ND ST APT B · ALHAMBRA, California, 91801 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 7.10 mW |
| 2 | 15C | 2.42 GHz - 2.45 GHz | 6.71 mW |