Velo ProductManual 2026-01-05 YOUSUPTE.LTD. ClitorisVibratorSeries FEV-A01 Version:1.0 1ProductInformation 1.ProductName:Velo 2.ProductModel:FEV-A01 3.ManufacturerInformation: Name:YOUSUPTE.LTD. Address:ROCCABALESTIER221BALESTIERROAD#03-006Singapore329928 Tel:65-80388543 2ProductOverview Veloisanadvancedwearablevibratordesignedforintimatepleasureanddiscreetwear. Featuringnext-generationwhisper-quiettechnology,extendedbatterylife,andenhanced connectivity,thispremiumproductofferspersonalizedexperiencesforsoloorpartneredplay. 2.1KeyFeatures Whisper-QuietMotor:Quietoperation ExtendedBatteryLife:Upto4hoursofcontinuoususe FlexibleMedical-GradeSilicone:Body-safeandwaterproof(IPX7rated) IntensityRange:9adjustablevibrationpatternswithcustomizablelevels MagneticCharging:Secureandconvenientchargingsystem DualConnectivity:Bluetooth5.0&Long-distanceconnectivityviaFyssaapp App-Controlled:Remoteoperationfromanywhereviainternet 2.2TechnicalSpecifications Material:Medical-gradesilicone,ABSplastic Waterproof:IPX7(submersibleupto1meterfor30minutes) Battery:Lithium-ion500mAh Connectivity:Bluetooth5.0 OperatingRange:Upto10meters(directBluetooth) ChargingTime:80minutes OperatingTemperature:10°Cto45°C Weight:68g 2.3PackageContents Velovibrator(1) Magneticchargingcable(1) Usermanual(1) 3SafetyInformation 3.1Warnings Notforusebypersonsunder18years Donotuseifyouhavecertainmedicalconditions(consultphysician) Discontinueuseifyouexperiencediscomfortorpain Keepawayfromopenwoundsorirritatedskin Notforuseduringpregnancywithoutmedicalconsultation 3.2Contraindications Pelvicinflammatorydisease Recentsurgeryormedicalprocedure Historyofseverepelvicpain Vaginaloranalbleeding Knownsiliconeallergies 3.3Precautions Pleasecleanthoroughlybeforeandafteruse Avoidusingwithsilicone-basedlubricants;water-basedlubricantsarerecommended Donotchargeorstoreinhigh-temperatureenvironments Pleasemakesuretheportisdrywhencharging. 4UserGuide 4.1GettingStarted 4.1.1Charging 1 . ConnectthemagneticchargingcabletoaUSBpowersource(5V/1Arecommended) 2 . AlignthemagneticendwiththechargingportonVelo 3 . LEDindicatorwillglowredduringcharging 4 . Chargingcompletesinapproximately80minutes(LEDturnsoff) 5 . Fullchargeprovidesupto4hoursofuse 4.1.2PowerControls Press&Hold(3seconds):PowerOn/Off SinglePress:Cyclethrough9presetvibrationpatterns LEDIndicator:Blue(poweron),Red(charging),Flashing(pairingmode) 4.1.3WearingGuide 1.Applyanappropriateamountofwater-basedlubricant 2.Gentlyplacethevibratorintothebody 3.Adjusttheflexibletailfintocomfortablyfittheoutsideofthebody 4.Makesureitissecurelywornbeforeuse 4.2ConnectivityGuide 4.2.1BluetoothPairing 1.EnableBluetoothonyoursmartphone 2.PoweronVelo 3.OpentheFyssaapp 4.Followin-apppairinginstructions 5.Connectionconfirmedbyappnotification 4.2.2Long-DistanceControl 1.BothusersmustinstallFyssaapp 2.ConnectVelotohostdeviceviaBluetooth 3.Sharecontrollinkviaappmessaging 4.Partnerconnectsremotelyviainternet 5.Real-timecontrolavailableworldwide 4.2.3AppFeatures Fyssaapp(availableoniOSandAndroid)includes: Custompatterncreator Synctomusicfeature Voicecontrolactivation Gameintegration Chatfunctionwithvibrationeffects Userprivacycontrols Firmwareupdates 4.3Troubleshooting IssueSolution Won’tpoweronChargefor30minutes,thentry NotconnectingtoappRestartdeviceandphoneBluetooth WeakvibrationsRechargefully OverheatingDiscontinueuse,allowtocool ConnectiondropsStaywithin10mrange,avoidinterference NotchargingCleanchargingcontacts,ensureproperalignment 5Care&Maintenance 5.1Cleaning 1 . Cleanbeforeandaftereachuse 2 . Usemildsoapandwarmwater 3 . Rinsethoroughly 4 . Patdrywithcleantowel 5 . Allowtoairdrycompletelybeforestorage 6 . Donotusealcohol-basedcleaners 5.2Storage&Maintenance Keepincool,dryplace Avoiddirectsunlight Keepawayfromsharpobjects Storeseparatelyfromothersiliconeproducts Ifnotusedforalongtime,chargeitonceeverythreemonthstoprotectthebattery. 6RegulatoryCompliance FCCCertified RoHSCompliant 7EnvironmentalNote Productisrecyclable Disposeaccordingtolocalelectronicwasteregulations Packagingmadefromrecycledmaterials 8FCCStatement ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice, pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotection againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcan radiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions, maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethat interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipment offandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthe followingmeasures: Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Caution:Anychangesormodificationstothisdevicenotexplicitlyapprovedbymanufacturer couldvoidyourauthoritytooperatethisequipment. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. RFExposureInformation ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement. Thedevicecanbeusedinportableexposurecondition,compliancewithexposurerequirements. Thisequipmentshouldbeinstalledandoperatedwithminimumdistance0mmbetweenthe radiator&yourbody.
Page1of5FCCID:2BVEX-FEVA01 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of5FCCID:2BVEX-FEVA01 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Fig.3 Fig.4 Page3of5FCCID:2BVEX-FEVA01 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Fig.5 Fig.6 Page4of5FCCID:2BVEX-FEVA01 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Fig.7 Fig.8 Page5of5FCCID:2BVEX-FEVA01 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com Fig.9
Page1of1FCCID:2BVEX-FEVA01 GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com LABELANDLOCATION (Size:L1.0cmxW0.5cm) LabelLocation Velo Model:FEV-A01 FCCID:2BVEX-FEVA01
Page 1 of 7FCC ID: 2BVEX-FEVA01 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Internal Photos of the EUT Fig. 1 Fig. 2 Page 2 of 7FCC ID: 2BVEX-FEVA01 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 3 Fig. 4 Page 3 of 7FCC ID: 2BVEX-FEVA01 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 5 Fig. 6 Page 4 of 7FCC ID: 2BVEX-FEVA01 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 7 Fig. 8 Page 5 of 7FCC ID: 2BVEX-FEVA01 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 9 Fig. 10 BluetoothAntenna Page 6 of 7FCC ID: 2BVEX-FEVA01 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 11 Fig. 12 Page 7 of 7FCC ID: 2BVEX-FEVA01 Guangzhou LCS Compliance Testing Laboratory Ltd. Add: No.44-1, Qianfeng North Road, Shiqi, Panyu District, Guangzhou, Guangdong, China Tel: +(86) 020-39166689 | E-mail: [email protected] | Web: www.lcs-cert.com Fig. 13 Fig. 14
Page 1 of 9 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation FOR YOUSUPTE.LTD. Velo TestModel:FEV-A01 Preparedfor:YOUSUPTE.LTD. Address: ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:March12,2026 Numberoftestedsamples:2 SampleNo.:C260312003-1,C260312003-2 Serialnumber:Prototype DateofTest:March12,2026~March25,2026 DateofReport:March26,2026 Page 2 of 9 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation ReportReferenceNo......................:LCSC03126001EB DateofIssue.......................................:March26,2026 TestingLaboratoryName..............:GuangzhouLCSComplianceTestingLaboratoryLtd. Address................................................: No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure.............:FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:YOUSUPTE.LTD. Address................................................:ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 TestSpecification Standard..............................................:FCCKDBpublication447498D01GeneralRFExposureGuidance v06 FCCCFR47part11.1310 FCCCFR47part22.1093 TestReportFormNo.........................:TRF-4-E-215A/0 TRFOriginator....................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription......................:Velo TradeMark..........................................:fyssa TestModel...........................................:FEV-A01 Ratings.................................................:PleaseRefertoPage6 Result..................................................:PASS Compiledby:Supervisedby:Approvedby: AceYao/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page 3 of 9 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RFExposureEvaluation TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC03126001EB March26,2026 Dateofissue TestModel.............................. : FEV-A01 EUT......................................... : Velo Applicant...............................:YOUSUPTE.LTD. Address...................................:ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:YOUSUPTE.LTD. Address...................................:ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 Telephone...............................:/ Fax..........................................:/ Factory...................................:DongguanImoonTechnologyCo.,Ltd. Address...................................:Building3,No.6FenghuangSouthRoad,LudongIndustrialPark, HumenTown,DongguanCity,GuangdongProvince,China Telephone...............................:/ Fax..........................................:/ Page 4 of 9 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000March26,2026InitialIssue--- Page 5 of 9 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EB GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS DescriptionPage 1.PRODUCTINFORMATION....................................................................................................................................6 2.EVALUATIONMETHODANDLIMIT....................................................................................................................7 3.REFEREVALUATIONMETHOD..........................................................................................................................7 4.CONDUCTEDPOWERRESULTS........................................................................................................................7 5.MANUFACTURINGTOLERANCE........................................................................................................................8 6.EVALUATIONRESULTS........................................................................................................................................8 7.CONCLUSION................................................................................................................................................…
Text truncated - open the document above for the full version.
Page 1 of 34 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT For YOUSUPTE.LTD. Velo TestModel:FEV-A01 Preparedfor:YOUSUPTE.LTD. Address:ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 Preparedby:GuangzhouLCSComplianceTestingLaboratoryLtd. Address:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China Tel:(+86)020-39166689 Fax:(+86)020-39166619 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:March12,2026 Numberoftestedsamples:2 SampleNo.:C260312003-1,C260312003-2 Serialnumber:Prototype DateofTest:March12,2026~March25,2026 DateofReport:March26,2026 Page 2 of 34 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSC03126001EA DateofIssue.......................................:March26,2026 TestingLaboratoryName..............:GuangzhouLCSComplianceTestingLaboratoryLtd. Address................................................:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou, Guangdong,China TestingLocation/Procedure............:FullapplicationofHarmonisedstandards■ PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:YOUSUPTE.LTD. Address................................................:ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo......................:TRF-4-E-145A/0 TRFOriginator....................................:GuangzhouLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 GuangzhouLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe GuangzhouLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.GuangzhouLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. EUTDescription...............................:Velo TradeMark..........................................:fyssa TestModel...........................................:FEV-A01 Ratings.................................................:PleaseRefertoPage6 Result..................................................:PASS Compiledby:Supervisedby:Approvedby: AceYao/AdministratorsJustinZhu/TechniqueDirectorGavinLiang/Manager Page 3 of 34 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com FCC--TESTREPORT TestModel...............................:FEV-A01 EUT.........................................:Velo Applicant...............................:YOUSUPTE.LTD. Address..................................:ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 Telephone...............................:/ Fax..........................................:/ Manufacturer........................:YOUSUPTE.LTD. Address...................................:ROCCABALESTIER221BALESTIERROAD#03-006Singapore 329928 Telephone...............................: Fax..........................................: Factory...................................:DongguanImoonTechnologyCo.,Ltd. Address...................................:Building3,No.6FenghuangSouthRoad,LudongIndustrialPark, HumenTown,DongguanCity,GuangdongProvince,China Telephone...............................:/ Fax..........................................:/ TestResultPASS Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSC03126001EA March26,2026 Dateofissue Page 4 of 34 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000March26,2026InitialIssue--- Page 5 of 34 FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TABLEOFCONTENTS 1.GENERALINFORMATION.....................................................................................................................................6 1.1.DESCRIPTIONOFDEVICE(EUT)........................................................................................................................6 1.2.SUPPORTEQUIPMENTLIST.................................................................................................................................7 1.3.EXTERNALI/OCABLE..........................................................................................................................................7 1.4.DESCRIPTIONOFTESTFACILITY........................................................................................................................7 1.5.STATEMENTOFTHEMEASUREMENTUNCERTAINTY..........................................................................................7 1.6.MEASUREMENTUNCERTAINTY............................................................................................................................8 1.7.DESCRIPTIONOFTESTMODES........................................................…
Text truncated - open the document above for the full version.
Page28of34FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2402 BLE_2M_Ant1_2440 Page29of34FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_2480 Page30of34FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com A.7EmissionsinRestrictedBands TestResult TestModeAntennaChNameFreq(MHz)Detector Freq [MHz] Result [dBm] Limit [dBm] Gain [dBi] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict BLE_1MAnt1 Low2402 AV2310.000-57.28≤-45.282.002.0842.00≤54PASS AV2388.095-55.95≤-45.282.002.0843.33≤54PASS AV2390.000-56.77≤-45.282.002.0842.51≤54PASS Peak2310.000-49.66≤-23.202.000.0047.54≤74PASS Peak2387.885-43.97≤-23.202.000.0053.23≤74PASS Peak2390.000-48.14≤-23.202.000.0049.06≤74PASS High2480 AV2483.500-53.24≤-45.172.001.9745.93≤54PASS AV2484.800-50.24≤-45.172.001.9748.93≤54PASS AV2500.000-56.38≤-45.172.001.9742.79≤54PASS Peak2483.500-43.61≤-23.202.000.0053.59≤74PASS Peak2485.040-35.56≤-23.202.000.0061.64≤74PASS Peak2500.000-47.5≤-23.202.000.0049.70≤74PASS BLE_2MAnt1 Low2402 AV2310.000-56.56≤-47.972.004.7745.41≤54PASS AV2348.090-56.39≤-47.972.004.7745.58≤54PASS AV2390.000-56.96≤-47.972.004.7745.01≤54PASS Peak2310.000-47.63≤-23.202.000.0049.57≤74PASS Peak2387.675-43.09≤-23.202.000.0054.11≤74PASS Peak2390.000-48.84≤-23.202.000.0048.36≤74PASS High2480 AV2483.500-51.72≤-47.972.004.7750.25≤54PASS AV2484.880-50.83≤-47.972.004.7751.14≤54PASS AV2500.000-56.62≤-47.972.004.7745.35≤54PASS Peak2483.500-41.13≤-23.202.000.0056.07≤74PASS Peak2484.800-34.75≤-23.202.000.0062.45≤74PASS Peak2500.000-48.48≤-23.202.000.0048.72≤74PASS Note: 1.TheAntennaGainiscompensatedinthegraph. 2.ThelimitindBmforaveragedetectorisconversionfrom54dBuV/m,accordingto15.209(a).The limitindBmforpeakdetectoris20dBabovethelimitofaveragedetectorindBm. Page31of34FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com TestGraphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV Page32of34FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_1M_Ant1_High_2480_Peak BLE_2M_Ant1_Low_2402_AV Page33of34FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com BLE_2M_Ant1_Low_2402_Peak BLE_2M_Ant1_High_2480_AV BLE_2M_Ant1_High_2480_Peak Page34of34FCCID:2BVEX-FEVA01ReportNo.:LCSC03126001EA GuangzhouLCSComplianceTestingLaboratoryLtd. Add:No.44-1,QianfengNorthRoad,Shiqi,PanyuDistrict,Guangzhou,Guangdong,China Tel:+(86)020-39166689|E-mail:[email protected]|Web:www.lcs-cert.com
Antenna SDC011P Datasheet Antenna Services Version: 1.0 Date: 2025-12-11 Status: Preliminary Antenna Services SDC011P Datasheet Antenna_Datasheet 1 / 12 At Quectel, our aim is to provide timely and comprehensive services to our customers. If you require any assistance, please contact our headquarters: Quectel Wireless Solutions Co., Ltd. Building 5, Shanghai Business Park Phase III (Area B), No.1016 Tianlin Road, Minhang District, Shanghai 200233, China Tel: +86 21 5108 6236 Email: [email protected] Or our local offices. For more information, please visit: http://www.quectel.com/support/sales.htm. For technical support, or to report documentation errors, please visit: http://www.quectel.com/support/technical.htm. Or email us at: [email protected]. Legal Notices We offer information as a service to you. The provided information is based on your requirements and we make every effort to ensure its quality. You agree that you are responsible for using independent analysis and evaluation in designing intended products, and we provide reference designs for illustrative purposes only. Before using any hardware, software or service guided by this document, please read this notice carefully. Even though we employ commercially reasonable efforts to provide the best possible experience, you hereby acknowledge and agree that this document and related services hereunder are provided to you on an “as available” basis. We may revise or restate this document from time to time at our sole discretion without any prior notice to you. Use and Disclosure Restrictions Copyright Our and third-party products hereunder may contain copyrighted material. Such copyrighted material shall not be copied, reproduced, distributed, merged, published, translated, or modified without prior written consent. We and the third party have exclusive rights over copyrighted material. No license shall be granted or conveyed under any patents, copyrights, trademarks, or service mark rights. To avoid ambiguities, purchasing in any form cannot be deemed as granting a license other than the normal non-exclusive, royalty-free license to use the material. We reserve the right to take legal action for noncompliance with abovementioned requirements, unauthorized use, or other illegal or malicious use of the material. Trademarks Except as otherwise set forth herein, nothing in this document shall be construed as conferring any rights to use any trademark, trade name or name, abbreviation, or counterfeit product thereof owned by Quectel or any third party in advertising, publicity, or other aspects. Antenna Services SDC011P Datasheet Antenna_Datasheet 2 / 12 Third-Party Rights This document may refer to hardware, software and/or documentation owned by one or more third parties (“third-party materials”). Use of such third-party materials shall be governed by all restrictions and obligations applicable thereto. We make no warranty or representation, either express or implied, regarding the third-party materials, including but not limited to any implied or statutory, warranties of merchantability or fitness for a particular purpose, quiet enjoyment, system integration, information accuracy, and non-infringement of any third-party intellectual property rights with regard to the licensed technology or use thereof. Nothing herein constitutes a representation or warranty by us to either develop, enhance, modify, distribute, market, sell, offer for sale, or otherwise maintain production of any our products or any other hardware, software, device, tool, information, or product. We moreover disclaim any and all warranties arising from the course of dealing or usage of trade. Privacy Policy To implement module functionality, certain device data are uploaded to Quectel’s or third-party’s servers, including carriers, chipset suppliers or customer-designated servers. Quectel, strictly abiding by the relevant laws and regulations, shall retain, use, disclose or otherwise process relevant data for the purpose of performing the service only or as permitted by applicable laws. Before data interaction with third parties, please be informed of their privacy and data security policy. Disclaimer a) We acknowledge no liability for any injury or damage arising from the reliance upon the information. b) We shall bear no liability resulting from any inaccuracies or omissions, or from the use of the information contained herein. c) While we have made every effort to ensure that the functions and features under development are free from errors, it is possible that they could contain errors, inaccuracies, and omissions. Unless otherwise provided by valid agreement, we make no warranties of any kind, either implied or express, and exclude all liability for any loss or damage suffered in connection with the use of features and functions under development, to the maximum extent permitted by law, regardless of whether such loss or damage may have been foreseeable. d) We are not responsible for the accessibility, safety, accuracy, availability, legality, or completeness of information, advertising, commercial offers, products, services, and materials on third-party websites and third-party resources. Copyright © Quectel Wireless Solutions Co., Ltd. 2021. All rights reserved.. Antenna Services SDC011P Datasheet Antenna_Datasheet 3 / 12 About the Document Revision History Version Date Author Note - 2025-12-11 Jaden Feng Creation of the document 1.0 2025-12-11 Jaden Feng…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.20 mW |