2BVFB-S71-2WVideo door phone intercom

Shenzhen FARHD Tech Co.,Ltd.
Video door phone intercom - FCC ID 2BVFB-S71-2W - Shenzhen FARHD Tech Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 03, 2026
Application Purpose
Original Equipment
Equipment Note
Video door phone intercom
Frequency Range
2412.00000000 - 2462.00000000
Company
Shenzhen FARHD Tech Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ConnectVideodoorphoneintercomtoApp Step1.ConnectyourphonetothesameWi-FiastheIndoorMonitor. DownloadTuyaSmartorSmartLife-SmartLivingfromGooglePlayor AppStore,thenregisterorlogintoyouraccount. Step2.OpenthemobileappandtapAddDevice,thenscancode,The appwillautomaticallysearchandconnecttoyourIndoorMonitor. Step3.ClickonSmartFacetoconnectWiFiandtobindApp. 1.HomePage 1.1.SilentMode Inrighttopcorner,tapthisicontoturnON/OFFsilentmode. 1.2.Settings Taptheicontoentersettings. 1.3.Turnoff Touchtoturnoffthescreen. 1.4.GateLock Taptheicon,andchoosethedoortounlock. 1.5.Media Viewvideosandphotosofcallrecords. 1.6.Intercom Tapandchooseamonitortocall. 1.7.Monitor Taptoviewthelivevideoofoutdoorcallpanel. 2.Intercom TaptocallMonitor2,3or4,ifconnected. 3.Monitor 3.1.Menu Taptoadjustbrightnessandvolume. 3.2.Video Taptostartrecordingavideo,andthenonemoretouchtostop. 3.3.Photo Taptotakeaphoto. 3.4.Doorlock Taptoopendoorlock. 3.5.Answer Taptostartconversation. 3.6.Hangup Taptohangupthemonitor. 3.7.Gatelock Taptoopengatelock. 4.Media Viewcallrecords,videosandphotos. 4.1.Callrecords Viewcallrecords.Tapdeletealltodeleteallcallrecords. 4.2.Video Viewvideorecords.TapDeletealltodeleteallvideos. 4.3.Photo Viewphotorecords.TapDeletealltodeleteallphotos. 5.Settings 5.1.System Setlanguage,keytone,videoorphotorecord,factorysetting,restartsystem, formattingSD,pedestriandetectionanddeviceID. 5.2.Time Settimeanddate. 5.3.Sound Setringtone,ringvolumeandcallvolume. 5.4.TuyaWiFi WiFiconnectionstate.TapresettounbindwithApp. 5.5.IPC ConnectIPcameras. 1.InSystemSettings-SecurityManagement-SystemServices,EnableOnvif service. 2.InSettings-SystemManagement-UserManagement-ONVIFUser,click AddUser,enterthenewusernameandnewpassword(usedtoaddacameratothe intercomdevice),selectuserfortheusergroup,andclickOK.(WeneedthisONVIF usernameandpassword). 3.InIPCsettings,clicktheIPaddressofcamera.Andthen,inputtheONVIF usernameandpassword.Afterthat,EnableandSave. 5.6.Doorlock Setunlockduration. FCCStatement Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates, usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoes causeharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturning theequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneor moreofthefollowingmeasures: —Reorientorrelocatethereceivingantenna. —Increasetheseparationbetweentheequipmentandreceiver. —Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. —Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Note:TheGranteeisnotresponsibleforanychangesormodificationsnotexpresslyapprovedby thepartyresponsibleforcompliance.suchmodificationscouldvoidtheuser'sauthorityto operatetheequipment. ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirement. TomaintaincompliancewithFCC'sRFexposureguidelines,thedistancemustbeatleast20cm betweentheradiatorandyourbody,andfullysupportedbytheoperatingandinstallation configurationsofthetransmitteranditsantenna(s).

Attestation Statements

ShenzhenFARHDTechCo.,Ltd. Address:6/F,SanheScienceandTechnologyPark,No.1,SanheRoad,GaofengCommunity, DalangStreet,LonghuaDistrict,ShenzhenCity,GuangdongProvince,China Date:2026-03-31 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2BVFB-S71-2W FRN:0038213112 (“ShenzhenFARHDTechCo.,Ltd.”)certifiesthat,asofthedateofthefilingoftheapplication, GOLDENVICTORYINTERNATIONALTRADINGCOLTDisourdesignatedU.S.agentfor serviceofprocessfortheabovereferencedFCCID.(“ShenzhenFARHDTechCo.,Ltd.”) acceptstomaintainanagentfornolessthanoneyearafterthegranteehasterminatedall marketingandimportationortheconclusionofanyCommission-relatedproceedinginvolving theequipment. GOLDENVICTORYINTERNATIONALTRADINGCOLTDaccepts,asofthedateofthefiling oftheapplication,theobligationofthedesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID. DesignatedU.S.AgentInformation: Name:GOLDENVICTORYINTERNATIONALTRADINGCOLTD Address:11016THSTREETSUITE1400DENVER,CO80202UnitedStates FRN:0036377570 ContactPerson:LeonHowar Tel.:(337)255-0461 Email:[email protected] Sincerely, Signedonbehalfof(ShenzhenFARHD TechCo.,Ltd.) SignedonbehalfofGOLDENVICTORY INTERNATIONALTRADINGCOLTD Name:ChuhuaZhouName:LeonHowar Title:SalesManagerTitle:Manager Date:2026-03-31Date:2026-03-31

Attestation Statements

Rev1/26/2023 (ShenzhenFARHDTechCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:3-31-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BVFB-S71-2W (“ShenzhenFARHDTechCo.,Ltd.”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903of theFCCrules. (“ShenzhenFARHDTechCo.,Ltd.”)certifiesthattheequipmentforwhichauthorizationissoughtdoes notincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofits successorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):ChuhuaZhou Rev1/26/2023 (ShenzhenFARHDTechCo.,Ltd.) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:3-31-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BVFB-S71-2W (“ShenzhenFARHDTechCo.,Ltd.”)certifiesthat,asofthedateofthefilingoftheapplication,Shenzhen FARHDTechCo.,Ltd.isnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature): (Applicantprintedname):ChuhuaZhou

Cover Letter(s)

ShenzhenFARHDTechCo.,Ltd. Date:March31,2026 ProductModelNumber:S71-2W,S70-2W,S72-2W,S73-2W,S74-2W, S75-2W,S76-2W,S70-4W-AHD,S71-4W-AHD,S72-4W-AHD, S73-4W-AHD,S74-4W-AHD,S76-4W-AHD,S77-SW-AHD,S10-4W-AHD, S101-4W-AHD,S102-4W-AHD,V1-2W,V2-2W,V3-2W,V3-2W,V5-2W, V6-2W,V7-2W,V1-4W-AHD,V2-4W-AHD,V3-4W-AHD,V4-4W-AHD, V5-4W-AHD,V6-4W-AHD,V7-4W-AHD,V901/02/03/04-4W-AHD, V901/02/03/04-4W,V901/02/03/04-2W,A1/2/3/4/6//8-2W, B8/10/12/14/16/24/32-2W,5A/6A/8A/16A/24A-2W,G-2WG10-2W,G7-2W, G5-2W,G10-IP,G7-IP,G8-IP,ICR-IP,IDR-IP,S43-IP,S45-IP,S46-IP, S73-IP,S70-IP,S72-IP,S71-IP,S75-IP,S74-IP,S76-IP,S10-IP, S72-IP-TUYA,S70-IP-TUYA,S71-IP-TUYA,S75-IP-TUYA,S76-IP-TUYA, S77-IP-TUYA,S78-IP-TUYA,S101-IP,S102-IP,S7-IP-TUYA,S10-IP-TUYA, S101-IP-TUYA,S102-IP-TUYAD21-IP,D22-IPD43-IP,D41-IP,D42-IP, D45-IP,D46-IP,IP-2W,IP01,IP02,IC01-IP,IC02-IP,IC03-IP, A1/2/3/4/6/8-IP,LW-4W,B8/10/12/14/16/24/32-IP,4A/8A/10A/16A/24A-IP, D5-IP,D6-IP,D7-IP,D8-IP,D9-IP,D10-IP FCCID:2BVFB-S71-2W Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:SalesManager Email:[email protected] Telephone:18565841485 Onbehalfof:ShenzhenFARHDTechCo.,Ltd.

Cover Letter(s)

ShenzhenFARHDTechCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:March31,2026 Subject;RequestforConfidentiality FCCID:2BVFB-S71-2W ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:ChuhuaZhou Title:SalesManager

Cover Letter(s)

ShenzhenFARHDTechCo.,Ltd. ModelDifference Date:March31,2026 Productdescription:Videodoorphoneintercom Modelname:S71-2W,S70-2W,S72-2W,S73-2W,S74-2W,S75-2W,S76-2W,S70- 4W-AHD,S71-4W-AHD,S72-4W-AHD,S73-4W-AHD,S74-4W-AHD,S76-4W-AHD, S77-SW-AHD,S10-4W-AHD,S101-4W-AHD,S102-4W-AHD,V1-2W,V2-2W,V3- 2W,V3-2W,V5-2W,V6-2W,V7-2W,V1-4W-AHD,V2-4W-AHD,V3-4W-AHD,V4- 4W-AHD,V5-4W-AHD,V6-4W-AHD,V7-4W-AHD,V901/02/03/04-4W-AHD, V901/02/03/04-4W,V901/02/03/04-2W,A1/2/3/4/6//8-2W,B8/10/12/14/16/24/32-2W, 5A/6A/8A/16A/24A-2W,G-2WG10-2W,G7-2W,G5-2W,G10-IP,G7-IP,G8-IP,ICR- IP,IDR-IP,S43-IP,S45-IP,S46-IP,S73-IP,S70-IP,S72-IP,S71-IP,S75-IP,S74-IP, S76-IP,S10-IP,S72-IP-TUYA,S70-IP-TUYA,S71-IP-TUYA,S75-IP-TUYA,S76-IP- TUYA,S77-IP-TUYA,S78-IP-TUYA,S101-IP,S102-IP,S7-IP-TUYA,S10-IP-TUYA, S101-IP-TUYA,S102-IP-TUYAD21-IP,D22-IPD43-IP,D41-IP,D42-IP,D45-IP,D46- IP,IP-2W,IP01,IP02,IC01-IP,IC02-IP,IC03-IP,A1/2/3/4/6/8-IP,LW-4W, B8/10/12/14/16/24/32-IP,4A/8A/10A/16A/24A-IP,D5-IP,D6-IP,D7-IP,D8-IP,D9-IP, D10-IP FCCID:2BVFB-S71-2W S71-2Wisthetestmodel,whileothermodelsarederivativemodels.Thesemodelsarethe sameonthecircuit,withonlydifferentmodelnames.Therefore,thetestdataofS71-2Wcan representtheremainingmodels. Client’ssignature: Client’sname/title:ChuhuaZhou/SalesManager Contactinformation/address:6/F,SanheScienceandTechnologyPark,No.1, SanheRoad,GaofengCommunity,DalangStreet,LonghuaDistrict,ShenzhenCity, GuangdongProvince,China

External Photos

FCCID:2BVFB-S71-2W EUTPHOTOSExternalPhotos FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Size:40mm*70mm

Internal Photos

FCCID:2BVFB-S71-2W EUTPHOTOSInternalPhotos FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W ANT FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W FCCID:2BVFB-S71-2W ※※※※※ENDOFREPORT※※※※※

RF Exposure Info

FCCID:2BVFB-S71-2W RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091, UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactof humanexposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency range (MHz) Electricfield strength (V/m) Magneticfield strength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthe totalpowerinputtotheantenna,throughthecalculation,wewillknowthedistancerwhere theMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middle andhighestchannelindividually. TestResultofRFExposureEvaluation Mode Max.Output powerto antenna (dBm) Max.Output powerto antenna (mW) Max.Power Densityat R=20cm (mW/cm2) Limit (mW/cm2) Result 2.4GWIFI11.0512.740.00571.0PASS Remark:Antennagain=3.62dBi

Test Report

ShenzhenYuShengCommunicationsElectronicsco.,LTD TEL:+860755-28640107FAX:+8675528694967 深圳市 Address: Floor 1-3, No. 102, Ouxi Road, Oubai Village, Shenzhen 深圳市 雨盛通讯电子 雨盛通讯电子 有限公司 有限公司 v ersion :A1 客户 : 品名规格 DESCRIPTION: 料号 PARTNO.: 客户料号 CUSPARTNO.: 日期 DATE: 呈样签章: 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 业务 SALESDEPARTMENT 客户承认签章: 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 采购 PURCHASINGDEPARTMENT ж Customer confirms sample attachment column: 承认书 APPROVAL 20 YS030-0151 26-1-6 2.4 built-in PCB spring antenna 100m ShenzhenYuShengCommunicationsElectronicsco.,LTD TEL:+860755-28640107FAX:+8675528694967 Floor1-3,No.102,OuxiRoad,OubaiVillage,Shenzhen 深圳市 深圳市 雨盛通讯电子 雨盛通讯电子 有限公司 有限公司 电器技术参数/Electrical technical parameters 电性能指标 ElectricalSpecifications 频率范围 Frequency2400-2500MHZRange2400-2500MHZ 电压驻波比 ≤2.0 VSWR ≤2.0 最大增益 MAX 3.62dBi GAIN 3 .62dBi 输入阻抗 50ΩInputImpedance50Ω 机械指标 MechanicalSpecifications 天线颜色 黑色 AntennaColorBLACK 接口形式 IPEXInputconnectorIPEX 工作温度 -40°C~+85°C WorkingTemperature -40°C~+85°C 工作湿度 20~80%WorkingHumidity20~80% Product image: ShenzhenYuShengCommunicationsElectronicsco.,LTD TEL:+860755-28640107FAX:+8675528694967 Floor1-3,No.102,OuxiRoad,OubaiVillage,Shenzhen 深圳市 深圳市 雨盛通讯电子 雨盛通讯电子 有限公司 有限公司 200PCS1袋 Specification Drawing: packaging diagram: Size:mm Shenzhen Sample testing: YuShengCommunicationsElectronicsco.,LTD TEL:+860755-28640107FAX:+8675528694967 Floor1-3,No.102,OuxiRoad,OubaiVillage,Shenzhen 深圳市 深圳市 雨盛通讯电子 雨盛通讯电子 有限公司 有限公司 proj e ct storage environmen test conditionsSpecifications t Test temperature, humidity, and air pressure without specifying as follows: high and low temperature te 1. The temperature ranges from -30 to+80 Normal ele ct ri c al and mechanical performanc 2. Relative humidity is 45% -85% 3. The air pressure ranges from 86kpa to 16kpa e st Constant humidity and heat resistance te The size should meet the requirements and should Satisfy and satisfy Regarding mechanical and electrical performanc Perf orm 5 cyc le s be tw een 70 °C and 40 °C, and then under normal conditions 1-2H, C he c k t he appearan c e q uali ty . e st vibration te The s ize s hould mee t t he requirements and should Sa t i sfy and s a t i sfy Regarding me c hani c al and electrical performanc Relat i v e humidi ty 95 ± 3%, t e st t empera t ure : 40 °C A ft er a co ntinuous action of 2 hours, Mea s ure t he ele ct ri c al per f orman c e o f t he t e st s ample within 5 minutes after removal, and the test sample should be in normal condition A ft er 1-2 hour s , c he c k t he appearan c e q uali ty e st drop te Normal electrical and mecha Vibration frequency range 10-55HZ, displacement amplitude: 0. 35MM, acceleration amplitude: 50.0M/S , Frequency sweep cycle times: 30 times nical performance st Normal electrical and Free fall 3 times from a height of 1M along mutually perpendicular axes mechanical performance Environmental performance testing: ShenzhenYuShengCommunicationsElectronicsco.,LTD FAX:+86755TEL:+860755-2864010728694967 Floor1-3,No.102,OuxiRoad,OubaiVillage,Shenzhen 深圳市 深圳市 雨盛通讯电子 雨盛通讯电子 有限公司 有限公司 Gain test: ShenzhenYuShengCommunicationsElectronicsco.,LTD TEL:+860755-28640107FAX:+8675528694967 Floor1-3,No.102,OuxiRoad,OubaiVillage,Shenzhen 深圳市 深圳市 雨盛通讯电子 雨盛通讯电子 有限公司 有限公司

Test Report

ProjectNo.:ZHT-260309127W02 Page 1 of 86 FCCTESTREPORT FCCID:2BVFB-S71-2W ApplicantName...............:ShenzhenFARHDTechCo.,Ltd. Address............................:6/F,SanheScienceandTechnologyPark,No.1,SanheRoad,Gaofeng Community,DalangStreet,LonghuaDistrict,ShenzhenCity,Guangdong Province,China ManufacturerName.........:ShenzhenFARHDTechCo.,Ltd. Address............................:6/F,SanheScienceandTechnologyPark,No.1,SanheRoad,Gaofeng Community,DalangStreet,LonghuaDistrict,ShenzhenCity,Guangdong Province,China Product/PMN...................:Videodoorphoneintercom Model(s)/HVIN.................:S71-2W AdditionalModel(s)..........:PleaserefertoChapter2.2 Trademark.......................:FARHD ModelDifference..............:S71-2Wisthetestmodel,whileothermodelsarederivativemodels. Thesemodelsarethesameonthecircuit,withonlydifferentmodel names.Therefore,thetestdataofS71-2Wcanrepresenttheremaining models. Preparedby.....................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:Mar.9,2026 DateofTest(s).................:Mar.9,2026-Mar.20,2026 DateofIssue....................:Mar.23,2026 TestRequested................:Selecttest(s)asrequestedbytheclient. TestStandard(s)..............:FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure................:KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10-2020+Cor1-2023 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. ProjectNo.:ZHT-260309127W02 Page 2 of 86 TableofContents Page 1.SUMMARYOFTESTRESULTS................................................................................................................4 2.GENERALINFORMATION........................................................................................................................5 2.1GENERALDESCRIPTIONOFEUT..................................................................................................5 2.3DESCRIPTIONOFTESTMODES.....................................................................................................6 2.4BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED................................7 2.5DESCRIPTIONOFSUPPORTUNITS...............................................................................................7 3.TESTFACILITYANDTESTINSTRUMENTUSED...................................................................................8 3.1TESTFACILITY..................................................................................................................................8 3.2EQUIPMENTSLISTFORALLTESTITEMS....................................................................................8 3.3TESTINGSOFTWARE.......................................................................................................................9 3.4MEASUREMENTUNCERTAINTY...................................................................................................10 4.EMCEMISSIONTEST.............................................................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT...................................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits....................................................................11 4.1.2TESTPROCEDURE................................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD...................................................................................11 4.1.4TESTSETUP...........................................................................................................................12 4.1.5EUTOPERATINGCONDITIONS............................................................................................12 4.1.6TESTRESULT.........................................................................................................................13 4.2RADIATEDEMISSIONMEASUREMENT.......................................................................................15 4.2.1RADIATEDEMISSIONLIMITS...............................................................................................15 4.2.2TESTPROCEDURE................................................................................................................15 4.2.3DEVIATIONFROMTESTSTANDARD..................................................................................16 4.2.4TESTSETUP...........................................................................................................................16 4.2.5EUTOPERATINGCONDITIONS............................................................................................17 4.2.6TESTRESULTS......................................................................................................................17 5.RADIATEDBANDEMISSIONMEASUREMENT.....................................................................................23 5.1TESTREQUIREMENT:....................................................................................................................23 5.2TESTPROCEDURE.........................................................................................................................23 5.3DEVIATIONFROMTESTSTANDARD...........................................................................................23 5.4TESTSETUP....................................................................................................................................24 5.5EUTOPERATINGCONDITIONS.............…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BVFB-S71-2W EUTTESTPHOTOS FCCID:2BVFB-S71-2W ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

Chuhua Zhou(Sales Manager)
[email protected]Fax: 18565841485

Technical Contact

GOLDEN VICTORY INTERNATIONAL TRADING CO LTDLeon Howar
[email protected]

110 16TH STREET SUITE 1400 DENVER, · United States

Test Firm

Guangdong Zhonghan Testing Technology Co., Ltd.Alex Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz12.70 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.