2BVIV-S03SCamera-S03S

MC Garcia Importacion y Exportacion Ltda
Camera-S03S - FCC ID 2BVIV-S03S - MC Garcia Importacion y Exportacion Ltda
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 18, 2026
Application Purpose
Original Equipment
Equipment Note
Camera-S03S
Frequency Range
2412.00000000 - 2462.00000000
Company
MC Garcia Importacion y Exportacion Ltda
Country
Chile

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Tuya Smart WiFi Camera User Manual Download App to Add Camera Power and Reset Note: Search for Tuya Smart in APP store or Google Play or Scan the QR Code below to download and install. Scan QR Code to download Power on the camera, turn on the device, it will hear a power-on prompt ƐŽƵŶĚ͕ůĨƚŚĞĐĂŵĞƌĂĚŽĞƐŶŽƚŚĂǀĞĂƉƌŽŵƉƚƐŽƵŶĚĨŽƌĂůŽŶŐƟŵĞ͕LJŽƵ ĐĂŶƉƌĞƐƐĂŶĚŚŽůĚƚŚĞĐĂŵĞƌĂZĞƐĞƚďƵƩŽŶƵŶƟůLJŽƵŚĞĂƌƚŚĞƉƌŽŵƉƚ ͞ZĞƐƚŽƌĞĨĂĐƚŽƌLJƐĞƫŶŐƐ͕ƉůĞĂƐĞĚŽŶŽƚƉŽǁĞƌŽīΗĂŶĚƌĞůĞĂƐĞŝƚƚŽƌĞƐƚŽƌĞ ƚŚĞĐĂŵĞƌĂƚŽĨĂĐƚŽƌLJƐĞƫŶŐƐĂŶĚƚŚĞŶĐŽŶĮŐƵƌĞƚŚĞŶĞƚǁŽƌŬ͘ ůĨLJŽƵŶĞĞĚůŽĐĂůƐƚŽƌĂŐĞ͕ƉůĞĂƐĞŝŶƐƚĂůůƚŚĞŵĞŵŽƌLJĐĂƌĚĮƌƐƚůLJ͕ĂŶĚ then power on the device (the memory card does not support hot swapping, please plug and unplug the memory car d when the device is powered oī). Cloud stor age is recommended, which is safe and convenient. Register/Log ϭ͘/ĨLJŽƵĂůƌĞĂĚLJŚĂǀĞĂŶĂĐĐŽƵŶƚ͕ƉůĞĂƐĞĐůŝĐŬΗ>ŽŐŝŶΗ;LJŽƵĐĂŶĂůƐŽĐŚŽŽƐĞ to log in using a third-party account). Ϯ͘/ĨLJŽƵĚŽŶΖƚŚĂǀĞĂŶĂĐĐŽƵŶƚLJĞƚ͕LJŽƵĐĂŶƌĞŐŝƐƚĞƌŽŶĞ͘ůŝĐŬΗ^ŝŐŶhƉΗ ƌĞĂĚƚŚĞƉƌŝǀĂĐLJƉŽůŝĐLJŽŶƚŚĞĂƉƉ͕ĐůŝĐŬΗŐƌĞĞΗƚŽĞŶƚĞƌƚŚĞƌĞŐŝƐƚƌĂƟŽŶ ƉĂŐĞ͕ĞŶƚĞƌLJŽƵƌĞŵĂŝůĂĚĚƌĞƐƐƚŽƌĞĐĞŝǀĞƚŚĞǀĞƌŝĮĐĂƟŽŶĐŽĚĞ͕ĂŶĚ ĐŽŵƉůĞƚĞƚŚĞƌĞŐŝƐƚƌĂƟŽŶ͘ Sign up account>ĂƵŶĐŚƚŚĞdƵLJĂ^ŵĂƌƚ>ŽŐŝŶĂĐĐŽƵŶƚ Add Device Connect to 2.4G WiFi and turn on Bluetooth Connecting 2.4G WiFiTurn on Bluetooth ŽŶŶĞĐƚLJŽƵƌƉŚŽŶĞƚŽtŝ&ŝĂŶĚƚƵƌŶŽŶůƵĞƚŽŽƚŚ͕ŬĞĞƉLJŽƵƌƉŚŽŶĞĂŶĚ ĚĞǀŝĐĞĂƐĐůŽƐĞĂƐƉŽƐƐŝďůĞǁŚĞŶĐŽŶĮŐƵƌŝŶŐ͘ Note: This device currently only supports 2.4GHz Wi-Fi and does not support 5GHz Wi-Fi. The Wi-Fi password should not contain any special characters, such as !@#S%&*(). IPC IPC Method 1: Bluetooth Quick Connection (Recommended) ǁĂŝƟŶŐ^ƵĐĐĞƐƐĨƵů Device Provisioning ^ĞƫŶŐĂŶĂŵĞĨŽƌƚŚĞĚĞǀŝĐĞ ĐŽŵƉůĞƚĞƐƚŚĞĂĚĚŝƟŽŶ ůŝĐŬŽŶ͟͞ŝŶƚŚĞƉŽƉͲƵƉ window on the home page Enter WiFi password Method 2: QR Code Connection dĂƉ͞ĂŵĞƌĂΘ>ŽĐŬ͟Ͳ Smart Camera (Fi-Wi) dĂƉ͞н͟Žƌ͞ĚĚĞǀŝĐĞ͟ to add device Default is QR Code mode and Tap next Power on and reset the ĚĞǀŝĐĞ͖ƚŚĞƐƚĂƚƵƐ>ǁŝůů ŇĂƐŚƌĂƉŝĚůLJ IPC Enter WiFi passwordScan the QR code on your cell phone with the camera ǁĂŝƟŶŐ^ƵĐĐĞƐƐĨƵů Device Provisioning ^ĞƫŶŐĂŶĂŵĞĨŽƌƚŚĞĚĞǀŝĐĞ ĐŽŵƉůĞƚĞƐƚŚĞĂĚĚŝƟŽŶ APP Function WůĂLJďĂĐŬƚŚĞ recordings Device Volume ^ĞƫŶŐƐ ^ŝƌĞŶĂůĂƌŵ;dŽŵĂŬĞ alarm sound to scare the suspicious person) Photo album Feature Editor Enable Auto ƚƌĂĐŬŝŶŐƚŽĨŽůůŽǁ the movement Theme color ;>ŝŐŚƚŵŽĚĞĂŶĚ ĚĂƌŬŵŽĚĞͿ DŽƟŽŶĚĞƚĞĐƟŽŶ alarm (Send alarm ŶŽƟĨĂĐƟŽŶŝĨĂŶLJ movement detected) Private Mode (Camera display ƚƵƌŶŽīŽŶĂƉƉͿ ^ŽƵŶĚĞƚĞĐƟŽŶ (Send alarm ŶŽƟĨĂĐƟŽŶŝĨ anysound detected) EŽƚĞ͗&ƵŶĐƟŽŶĂůŝƚLJŵĂLJĚŝīĞƌĂĐƌŽƐƐŵŽĚĞůƐ͘^ƉĞĐŝĮĐĂƟŽŶƐƐƵďũĞĐƚƚŽĂĐƚƵĂůƉƌŽĚƵĐƚ͘ Google Assistant And Alexa 1.Family management 10.Capture the current live view 2.AI assistant 11.ĚŝƟŶŐĨƵŶĐƟŽŶ 3.Add a new device 12.Home device management 4.Room management 5.Enter the device live view page ς͘WƌĞǀŝĞǁďƵƩŽŶĨŽƌĂĚĚĞĚĚĞǀŝĐĞƐ 8.ŽŶĮŐƵƌĞƚŚĞĚĞǀŝĐĞ 9.ůŽƵĚƐƚŽƌĂŐĞƐĞƌǀŝĐĞ;ƐƵďƐĐƌŝƉƟŽŶƌĞƋƵŝƌĞĚͿ 7.View device alarm messages 13.My account center 14.^ŵĂƌƚ;ŝīĞƌĞŶƚĨƌŽŵŚŽŵĞƉĂŐĞ͕ƚŚŝƐ ƐŵĂƌƚŝƐƚŽƐĞƚŽŶůLJĐĂŵĞƌĂƐŵĂƌƚĂĐƟŽŶƐͿ 15.More service assistants ϭϳ͘>ŝǀĞsŝĞǁ^ŽƵŶĚ^ǁŝƚĐŚ 16.Device name 18.DŽƌĞĚĞǀŝĐĞƐĞƫŶŐƐ 19.ZĞƐŽůƵƟŽŶƐǁŝƚĐŚŝŶŐ 20.>ŝǀĞsŝĞǁůĞĐƚƌŽŶŝĐDĂŐŶŝĮĐĂƟŽŶ 21.Monitoring live stream view 22.WƌĞƐƐĂŶĚŚŽůĚƚŚĞŵŝĐƌŽƉŚŽŶĞƚŽƐƉĞĂŬ 23.dĂŬĞĂƐĐƌĞĞŶƐŚŽƚŽĨƚŚĞĐƵƌƌĞŶƚůŝǀĞƐƚƌĞĂŵ 24.Record a video of the current live stream view 25.Display the live stream view in full screen Ϯς͘&ƵŶĐƟŽŶŵĞŶƵĐŽůůĂƉƐĞďƵƩŽŶ Ϯϳ͘sŝĞǁĂůůŵĞƐƐĂŐĞƐĨƌŽŵƚŚĞĚĞǀŝĐĞĚĞƚĞĐƟŽŶ ϮΘ͘&ƵŶĐƟŽŶDĞŶƵ Ϯε͘ŽŶƚƌŽůƚŚĞWdƌŽƚĂƟŽŶĚŝƌĞĐƟŽŶŽĨƚŚĞĐĂŵĞƌĂ 30.Set preset points for area surveillance ϯϭ͘ůŽƵĚƐƚŽƌĂŐĞƐĞƌǀŝĐĞ;ƐƵďƐĐƌŝƉƟŽŶƌĞƋƵŝƌĞĚͿ ϯϮ͘^ŵĂƌƚ;ŝīĞƌĞŶƚĨƌŽŵŚŽŵĞƉĂŐĞ͕ƚŚŝƐ ƐŵĂƌƚŝƐƚŽƐĞƚŽŶůLJĐĂŵĞƌĂƐŵĂƌƚĂĐƟŽŶƐͿ Please make sure your device have enable this function WƌĞĐŽŶĚŝƟŽŶ Pariing Tuya Smart to Smart Speaker APP (1) Download and install the Google Home or Amazon Alexa APP according to the Smart ƐƉĞĂŬĞƌLJŽƵŚĂǀĞ͘ ;ϭͿ>ŽŐŝŶŽŶ'ŽŽŐůĞ,ŽŵĞWWĐůŝĐŬƚŚĞƌŝŐŚƚĐŽƌŶŶĞƌŽĨŝŶĚŝǀŝĚƵĂůƐĞƫŶŐƐͲƐƐŝƐƚĂŶƚ^ĞƫŶŐƐ ͲͲĐŚŽŽƐĞƐƐŝƐƚĂŶƚͲͲ,ŽŵĞΗŽŶƚƌŽůͲͲ^ĞĂƌĐŚƚŚĞdƵLJĂ^ŵĂƌƚWW͕ƚŚĞƉĂŐĞǁŝůůĚŝƌĞĐƚƚŽƚŚĞ ƚƵLJĂƐŵĂƌƚůŽŐŝŶƉĂŐĞƉůĞĂƐĞŝŶƉƵƚLJŽƵƌƚƵLJĂƐŵĂƌƚĂƉƉĂĐĐŽƵŶƚĂŶĚƉĂƐƐǁŽƌĚĂŶĚĐůŝĐŬ ƵƚŚŽƌŝƐĞΗƚŽůŝŶŬƚƵLJĂƐŵĂƌƚĂƉƉǁŝƚŚLJŽƵƌ'ŽŽŐůĞ,ŽŵĞWW͕dŚĞŶLJŽƵǁŝůůďĞĂďůĞƚŽ see the devices support Google Assistant in your home device list. (2)Control your devices through Google Home APP .For the smart camera you could say as below: ͞KŬ'ŽŽŐůĞ͕ƐŚŽǁŵĞƚŚĞƐŵĂƌƚĐĂŵĞƌĂ͟ ͞KŬ'ŽŽŐůĞ͕ƐŚŽǁŵĞƚŚĞ/W͟ ͞KŬ'ŽŽŐůĞ͕ƐŚŽǁŵĞƚŚĞƐĞĐƵƌŝƚLJĐĂŵĞƌĂ͟ ŶĚLJŽƵĐŽƵůĚĂůƐŽŐŝǀĞƐŽŵĞĨĂŵŝůŝĂƌŶĂŵĞƚŽƚŚĞĚĞǀŝĐĞůŝŬĞĨƌŽŶƚĚŽŽƌ͕ďĞĚƌŽŽŵ͕ŚĂŚĂĞƚĐ͘ ͞KŬŐŽŽŐůĞƐŚŽǁŵĞĨƌŽŶƚĚŽŽƌͬďĞĚƌŽŽŵͬŚĂŚĂ͟ >ŝŶŬǁŝƚŚ'ŽŽŐůĞ,ŽŵĞWW^ƵƉƉŽƌƚ'ŽŽŐůĞEĞƐƚ,Ƶď͕ŚƌŽŵĞĐĂƐƚŝƐƉůĂLJĞƚĐ ;ϮͿZĞŐŝƐƚĞƌƚŚĞĂĐĐŽƵŶƚĂŶĚƉĂŝƌLJŽƵƌƐŵĂƌƚƐƉĞĂŬĞƌǁŝƚŚWW͘ FQA ;ϭͿ>ŽŐŝŶŽŶŵĂnjŽŶůĞdžĂWWĂŶĚĐůŝĐŬŵĞŶƵŽŶƚŚĞůĞŌĐŽƌŶŶĞƌ͘^ĞůĞĐƚƐŬŝůůŵĞŶƵƚŽĞŶƚĞƌƐŬŝůů ƐƚŽƌĞͲƐĞĂƌĐŚdƵLJĂƐŵĂƌƚͲͲůŝĐŬŶĂďůĞďƵƩŽŶͲͲŝƚǁŝůůĚŝƌĞĐƚƚŽƚƵLJĂƐŵĂƌƚůŽŐŝŶƉĂŐĞƉůĞĂƐĞ ŝŶƉƵƚLJŽƵƌƚƵLJĂƐŵĂƌƚĂƉƉĂĐĐŽƵŶƚĂŶĚƉĂƐƐǁŽƌĚͲͲƚŚĞŶƐƉĞĂŬƚŽĐŚŽΗůĞdžĂ͕ŝƐĐŽǀĞƌƚŚĞ ĚĞǀŝĐĞƐΗͲͲƚŚĞŶLJŽƵǁŝůůĂďůĞƚŽƐĞĞƚŚĞĚĞǀŝĐĞƐŝŶLJŽƵƌƚƵLJĂƐŵĂƌƚĂƉƉĂĐĐŽƵŶƚ͘ (2)Control your devices through Amazon Alexa APP .For the smart camera you could say as below: ͞ůĞdžĂ͕ƐŚŽǁŵĞƚŚĞƐŵĂƌƚĐĂŵĞƌĂ͟ ͞ůĞdžĂ͕ƐŚŽǁŵĞƚŚĞ/W͟ ͞ůĞdžĂ͕ƐŚŽǁŵĞƚŚĞƐĞĐƵƌŝƚLJĐĂŵĞƌĂ͟ >ŝŶŬǁŝƚŚŵĂnjŽŶůĞdžĂWW͘^ƵƉƉŽƌƚĐŚŽ^ƉŽƚ͕ĐŚŽ^ŚŽǁρͬΘͬϭϬĞƚĐ Yϭ͗,ŽǁĚŽ/ƌĞƐĞƚŵLJĐĂŵĞƌĂƚŽĨĂĐƚŽƌLJƐĞƫŶŐƐ͍ ϭ͗ĞůĞƚĞƚŚĞĐĂŵĞƌĂĨƌŽŵLJŽƵƌĂƉƉůŝƐƚĚŝƌĞĐƚůLJŽƌůŽŶŐƉƌĞƐƐƚŚĞƌĞƐĞƚďƵƩŽŶĨŽƌΘƐƵŶƟůLJŽƵ ŚĞĂƌƚŚĞǀŽŝĐĞ͞ZĞƐĞƚ͕ĐĂŵĞƌĂƌĞƚ͟ YϮ͗/ŚĂǀĞƐĞůĞĐƚƚŚĞϮ͘κ'Θρ',njt/Ͳ&ůĂŶĚŝŶƉƵƚƉĂƐƐǁŽƌĚĐŽƌƌĞĐƚůLJǁŚLJ…

Text truncated - open the document above for the full version.

External Photos

FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Appendix III EUT External Photographs Photo 1 Appearance of EUT Photo 2 Appearance of Adapter FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 3 Appearance of EUT Photo 4 Appearance of EUT FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 5 Appearance of EUT Photo 6 Appearance of EUT FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 7 Appearance of EUT Photo 8 Appearance of EUT

ID Label/Location Info

FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Appendix IID Label Appendix II ID Label Location Camera-S03S FCC ID: 2BVIV-S03S Model: S03S

Internal Photos

FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Appendix IV EUT Internal Photographs Photo 9 Internal of EUT Photo 10 Internal of EUT FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 11 Internal of EUT Photo 12 Internal of EUT 2.4G WIFI Antenna Non-emitting Antenna FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 13 Internal of EUT Photo 14 Appearance of PCB FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 15 Appearance of PCB Photo 16 Appearance of PCB FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 17 Appearance of PCB Photo 18 Appearance of PCB FCC ID: 2BVIV-S03S www.cotecna-toby.com TB-RF-073-3.1 Photo 19 Appearance of PCB Photo 20 Appearance of PCB

RF Exposure Info

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202603-0361-2 Page: 1 of 8 TB-RF-073-3.1 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Email: [email protected] www.cotecna-toby.com Maximum Permissible Exposure Evaluation FCC ID: 2BVIV-S03S Report No. : TBR-C-202603-0361-2 Applicant : MC Garcia Importacion y Exportacion Ltda Equipment Under Test (EUT) EUT Name : Camera-S03S Model No. : S03S Series Model No. : S05S, S06S, S07S, S08S, S09S, Q25, Q27, Q28, Q29, Q32, Q34, Q56, Q58, Q59, C32, C34, C36, C38 Brand Name : Veloti Sample ID : HC-C-202603-0361-01-01-1#&HC-C-202603-0361-01-01-2# Receipt Date : 2026-04-02 Test Date : 2026-04-02 to 2026-04-28 Issue Date : 2026-04-28 Standards : FCC Part 2.1091 Test Method : KDB 447498 D01 General RF Exposure Guidance v06 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Tested By : Gold. zhang Reviewed By : Wade. Lv Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202603-0361-2 Page: 2 of 8 www.cotecna-toby.com TB-RF-073-3.1 CONTENTS CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 4 1.1 Client Information ................................................................................................................. 4 1.2 General Description of EUT (Equipment Under Test) ................................................... 4 2. MEASUREMENT UNCERTAINTY .......................................................................................... 5 3. TEST FACILITY.......................................................................................................................... 6 4. METHOD OF MEASUREMENT FOR FCC............................................................................ 7 5. TEST RESULT............................................................................................................................ 8 Report No.: TBR-C-202603-0361-2 Page: 3 of 8 www.cotecna-toby.com TB-RF-073-3.1 Revision History Report No. Version Description Issued Date TBR-C-202603-0361-2 Rev.01 Initial issue of report 2026-04-28 Report No.: TBR-C-202603-0361-2 Page: 4 of 8 www.cotecna-toby.com TB-RF-073-3.1 1. General Information about EUT 1.1 Client Information Applicant : MC Garcia Importacion y Exportacion Ltda Address : Americo Vespucio Norte, 2500, Santiago - Chile Manufacturer : MC Garcia Importacion y Exportacion Ltda Address : Americo Vespucio Norte, 2500, Santiago - Chile 1.2 General Description of EUT (Equipment Under Test) EUT Name : Camera-S03S Models No. : S03S, S05S, S06S, S07S, S08S, S09S, Q25, Q27, Q28, Q29, Q32, Q34, Q56, Q58, Q59, C32, C34, C36, C38 Model Different : All these models are identical in the same PCB layout and electrical circuit, only difference is model name. Product Description : Operation Frequency: 802.11b/g/n(HT20): 2412MHz~2462MHz Modulation Type: 802.11b: DSSS (DQPSK, DBPSK, CCK) 802.11g: OFDM (BPSK, QPSK,16QAM, 64QAM) 802.11n: OFDM (BPSK, QPSK,16QAM, 64QAM) Antenna Gain: 2.73dBi Dipole Antenna Power Rating : Power Supply (Model: CS-0501000) Input: 100-240V~0.5A Max. 50/60Hz Output: 5V/1.0A Software Version : ---- Hardware Version : ---- Remark: The above antenna information is declared by manufacturer and for more detailed features description, please refer to the manufacturer's specifications, the laboratory shall not be held responsible. Report No.: TBR-C-202603-0361-2 Page: 5 of 8 www.cotecna-toby.com TB-RF-073-3.1 2. Measurement Uncertainty The reported uncertainty of measurement y±U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %. Test Item Parameters Expanded Uncertainty (U Lab ) Conducted Emission Level Accuracy: 9kHz~150kHz 150kHz to 30MHz ±3.50 dB ±3.10 dB Radiated Emission Level Accuracy: 9kHz to 30 MHz ±4.60 dB Radiated Emission Level Accuracy: 30MHz to 1000 MHz ±4.50 dB Radiated Emission Level Accuracy: Above 1000MHz ±4.20 dB RF Power-Conducted Level Accuracy: Above 1000MHz ±0.95 dB Power Spectral Density- Conducted Level Accuracy: Above 1000MHz ±3dB Occupied Bandwidth Level Accuracy: 30MHz to 1000 MHz Above 1000MHz ±3.8% Unwanted Emission- Conducted Level Accuracy: 30MHz to 1000 MHz Above 1000MHz ±2.72 dB Temperature / ±0.6°C Humidity / ±4% Supply voltages / ±2% Time / ±4% Report No.: TBR-C-202603-0361-2 Page: 6 of 8 www.cotecna-toby.com TB-RF-073-3.1 3. Test Facility The testing report were performed by the Shenzhen Toby Technology Co., Ltd., in their facilities located at 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. At the time of testing, the following bodies accredited the Laboratory: CNAS (L5813) The Laboratory has been accredited by CNAS to ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories for the competence in the field of testing. And the Registration No.: CNAS L5813. A2LA Certificate No.: 4750.01 The laboratory has been accredited by American Association for Laboratory Accreditation(A2LA) to ISO/IEC 17025:2017 General Requirements for the Competence of Testing and Calibration Laboratories for the technical competence in the field of Electrical Testing. And the A2LA Certificate No.: 4750.01.FCC Accredited Test Site Number: 854351. Designation Number: CN1223. IC Registration No.: (11950A) The Laboratory has been registered by Certificatio…

Text truncated - open the document above for the full version.

Test Report

QR/RD-P01-06B SPECIFICATION ShenzhenFeixinWirelessCommunication 深圳飞芯无线通讯有限公司 ShenzhenFeixinWirelessCommunicationCo.,Ltd. 2.4GAntenna Productspecification CustomerFrequency 2400MHz——2500MHz RFdesign XIAOBIN VersionA1 Technical director ANDYdate2026-05-06 Customerconfirmation: Whethertheassemblymeetsyourcompany'srequirements :□ OK □ NG ShenzhenFeixinWirelessCommunicationCo.,LTD Confidentialityrequirement TheinformationprovidedbytheproprietarytechnologyalreadyownedbytheCompanyshallbekeptstrictlyconfidentialandshallnotbe disclosedtoanypersonorcompanywithoutthepriorwrittenconsentofShenzhenFeixinWirelessCommunicationCo.,LTD. ShenzhenCompany:3rdFloor,BuildingA,ChangjingRobotIndustrialPark,GuanhuStreet,LonghuaDistrict,Shenzhen ShanghaiCompany:202,Building16,No.618DingyuanRoad,SongjiangDistrict,ShanghaiTel:+86-021-52060235Fax: +86-021-34711533 http://www.flxant.comhttp://www.fly-core.comPage Page2 Directory Cover.......................................................................................................1 1、Directory...........................................................................2 2、Productpictures...............................................................................3 3、S11data.................................................................................4 4、 Antennapassivetestdata: ....................................................................4 5、Productstructuredrawing..........................................................9 ShenzhenFeixinWirelessCommunicationCo.,LTD Confidentialityrequirement TheinformationprovidedbytheproprietarytechnologyalreadyownedbytheCompanyshallbekeptstrictlyconfidentialandshallnotbe disclosedtoanypersonorcompanywithoutthepriorwrittenconsentofShenzhenFeixinWirelessCommunicationCo.,LTD. ShenzhenCompany:3rdFloor,BuildingA,ChangjingRobotIndustrialPark,GuanhuStreet,LonghuaDistrict,Shenzhen ShanghaiCompany:202,Building16,No.618DingyuanRoad,SongjiangDistrict,ShanghaiTel:+86-021-52060235Fax: +86-021-34711533 http://www.flxant.comhttp://www.fly-core.comPage Page3 1、Productpictures 2、Productparameters 产品测试参数 产品名称(Name) 2.4GFPCantenna 产品型号(ModelType) FX-2.4-2DB-1.13B-220- 1 电性能指标 (ElectricalSpecifications) 频率范围(FrenquencyRange) 2400-2500MHz 极化方式 ( Polarization ) 垂直(vertical) 输入阻抗(Impedance) 50Ω 辐射方向(Radiation direction) 全向(Omnidirectional) 驻波比(VSWR)≦3.0功率容量(Power) \ 增益(Gain) 2.73dBi 带宽(Bandwidth 100 机械指标 (MechanicalSpecifications) 尺寸(Dimensions)105±1mm天线颜色(AntColor) white 连接器型号(Connector) IPEX1D 引线长度(CableLength)220±3mm 天线材料(AntMaterial) FPC 工作温度 (WorkingTemperature) -40°C-+85°C 存放温度 (LimitTemperature) -40°C-+85°C ShenzhenFeixinWirelessCommunicationCo.,LTD Confidentialityrequirement TheinformationprovidedbytheproprietarytechnologyalreadyownedbytheCompanyshallbekeptstrictlyconfidentialandshallnotbe disclosedtoanypersonorcompanywithoutthepriorwrittenconsentofShenzhenFeixinWirelessCommunicationCo.,LTD. ShenzhenCompany:3rdFloor,BuildingA,ChangjingRobotIndustrialPark,GuanhuStreet,LonghuaDistrict,Shenzhen ShanghaiCompany:202,Building16,No.618DingyuanRoad,SongjiangDistrict,ShanghaiTel:+86-021-52060235Fax: +86-021-34711533 http://www.flxant.comhttp://www.fly-core.comPage Page4 3.VSWR,ReturnlossandSmithdata (1)Antennaefficiencyandgain: ShenzhenFeixinWirelessCommunicationCo.,LTD Confidentialityrequirement TheinformationprovidedbytheproprietarytechnologyalreadyownedbytheCompanyshallbekeptstrictlyconfidentialandshallnotbe disclosedtoanypersonorcompanywithoutthepriorwrittenconsentofShenzhenFeixinWirelessCommunicationCo.,LTD. ShenzhenCompany:3rdFloor,BuildingA,ChangjingRobotIndustrialPark,GuanhuStreet,LonghuaDistrict,Shenzhen ShanghaiCompany:202,Building16,No.618DingyuanRoad,SongjiangDistrict,ShanghaiTel:+86-021-52060235Fax: +86-021-34711533 http://www.flxant.comhttp://www.fly-core.comPage Page5 Passive-Freq2470.00MHZ ShenzhenFeixinWirelessCommunicationCo.,LTD Confidentialityrequirement TheinformationprovidedbytheproprietarytechnologyalreadyownedbytheCompanyshallbekeptstrictlyconfidentialandshallnotbe disclosedtoanypersonorcompanywithoutthepriorwrittenconsentofShenzhenFeixinWirelessCommunicationCo.,LTD. ShenzhenCompany:3rdFloor,BuildingA,ChangjingRobotIndustrialPark,GuanhuStreet,LonghuaDistrict,Shenzhen ShanghaiCompany:202,Building16,No.618DingyuanRoad,SongjiangDistrict,ShanghaiTel:+86-021-52060235Fax: +86-021-34711533 http://www.flxant.comhttp://www.fly-core.comPage Page6 ShenzhenFeixinWirelessCommunicationCo.,LTD Confidentialityrequirement TheinformationprovidedbytheproprietarytechnologyalreadyownedbytheCompanyshallbekeptstrictlyconfidentialandshallnotbe disclosedtoanypersonorcompanywithoutthepriorwrittenconsentofShenzhenFeixinWirelessCommunicationCo.,LTD. ShenzhenCompany:3rdFloor,BuildingA,ChangjingRobotIndustrialPark,GuanhuStreet,LonghuaDistrict,Shenzhen ShanghaiCompany:202,Building16,No.618DingyuanRoad,SongjiangDistrict,ShanghaiTel:+86-021-52060235Fax: +86-021-34711533 http://www.flxant.comhttp://www.fly-core.comPage Page7 4、Productstructuredrawing 2 2 0 ± 3

Test Report

Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202603-0361-1 Page: 1 of 25 FCC ID: 2BVIV-S03S TB-RF-073-3.1 RF Test Data for 2.4G Wi-Fi (Conducted Measurements) General Description of EUT EUT Name: Camera-S03S Model: S03S Sample ID: HC-C-202603-0361-01-01-2# Test Standard: FCC Part 15.247 Environmental Conditions Ambient Temperature: 25°C Ambient Humidity: 45%RH Test Power Supply: DC 5V Test Engineer: Gold. Zhang Note: For a more detailed features description, please refer to the report TBR-C-202603-0361-1 Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202603-0361-1 Page: 2 of 25 FCC ID: 2BVIV-S03S TB-RF-073-3.1 Contents 1: DTS Bandwidth ............................................................................................................................................... 3 1.1Test Result .......................................................................................................................................... 3 1.2 Test Graphs ....................................................................................................................................... 4 2: Occupied Channel Bandwidth ........................................................................................................................ 6 2.1 Test Result ......................................................................................................................................... 6 2.2 Test Graphs ....................................................................................................................................... 7 3: Maximum conducted output power .............................................................................................................. 9 3.1 Test Result Average .......................................................................................................................... 9 4: Maximum power spectral density ............................................................................................................... 10 4.1 Test Result ....................................................................................................................................... 10 4.2 Test Graphs ..................................................................................................................................... 11 5: Band edge measurements ........................................................................................................................... 13 5.1 Test Result ....................................................................................................................................... 13 5.2 Test Graphs ..................................................................................................................................... 14 6: Conducted Spurious Emission ...................................................................................................................... 15 6.1 Test Result ....................................................................................................................................... 15 6.2 Test Graphs ..................................................................................................................................... 16 7: Duty Cycle .................................................................................................................................................... 21 7.1 Test Result ....................................................................................................................................... 21 7.2 Test Graphs ..................................................................................................................................... 22 8: Emissions in Restricted Bands ...................................................................................................................... 23 8.1 Test Result ....................................................................................................................................... 23 8.2 Test Graphs ..................................................................................................................................... 24 Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202603-0361-1 Page: 3 of 25 FCC ID: 2BVIV-S03S TB-RF-073-3.1 1: DTS Bandwidth 1.1Test Result Test Mode Ant. Frequency [MHz] DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 9.56 2407.44 2417.00 0.5 PASS 11B Ant1 2437 10.04 2431.96 2442.00 0.5 PASS 11B Ant1 2462 10.04 2456.96 2467.00 0.5 PASS 11G Ant1 2412 16.04 2403.96 2420.00 0.5 PASS 11G Ant1 2437 14.20 2430.64 2444.84 0.5 PASS 11G Ant1 2462 16.32 2453.84 2470.16 0.5 PASS 11N20SISO Ant1 2412 17.16 2403.44 2420.60 0.5 PASS 11N20SISO Ant1 2437 16.56 2428.80 2445.36 0.5 PASS 11N20SISO Ant1 2462 16.68 2453.60 2470.28 0.5 PASS Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202603-0361-1 Page: 4 of 25 FCC ID: 2BVIV-S03S TB-RF-073-3.1 1.2 Test Graphs 11B-Ant1-2412-PASS 11B-Ant1-2437-PASS 11B-Ant1-2462-PASS 11G-Ant1-2412-PASS 11G-Ant1-2437-PASS 11G-Ant1-2462-PASS Shenzhen Toby Technology Co., Ltd. Http://www.cotecna-toby.com Add:1/F.,Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China. Report No.: TBR-C-202603-0361-1 Page: 5 of 25 FCC ID: 2BVIV-S03S TB-RF-073-3.1 11N20SISO-Ant1-2412-PASS 11N20SISO-Ant1-2437-PASS 11N20SISO-Ant1-2462-PASS Shenzhen Toby Technol…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Toby Technology Co., Ltd. Report No.: TBR-C-202603-0361-1 Page: 1 of 36 TB-RF-073-3.1 1/F., Building 6, Rundongsheng Industrial Zone, Longzhu, Xixiang, Bao'an District, Shenzhen, Guangdong, China Tel: +86 75526509301 Email: [email protected] www.cotecna-toby.com RF Test Report FCC ID: 2BVIV-S03S Report No. : TBR-C-202603-0361-1 Applicant : MC Garcia Importacion y Exportacion Ltda Equipment Under Test (EUT) EUT Name : Camera-S03S Model No. : S03S Series Model No. : S05S, S06S, S07S, S08S, S09S, Q25, Q27, Q28, Q29, Q32, Q34, Q56, Q58, Q59, C32, C34, C36, C38 Brand Name : Veloti Sample ID : HC-C-202603-0361-01-01-1#&HC-C-202603-0361-01-01-2# Receipt Date : 2026-04-02 Test Date : 2026-04-02 to 2026-04-28 Issue Date : 2026-04-28 Standards : FCC Part 15 Subpart C 15.247 Test Method : ANSI C63.10: 2020+Cor.1:2023+C63.10a:2024 +Errata to C63.10a:2024 KDB 558074 D01 15.247 Meas Guidance v05r02 Conclusions : PASS In the configuration tested, the EUT complied with the standards specified above. Tested By : Gold. zhang Reviewed By : Wade. Lv Approved By : Ivan Su This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in the report. Report No.: TBR-C-202603-0361-1 Page: 2 of 36 www.cotecna-toby.com TB-RF-073-3.1 Contents CONTENTS ............................................................................................................................................. 2 1. GENERAL INFORMATION ABOUT EUT.............................................................................. 5 1.1 Client Information ................................................................................................................. 5 1.2 General Description of EUT (Equipment Under Test) ................................................... 5 1.3 Block Diagram Showing the Configuration of System Tested ...................................... 7 1.4 Description of Support Units .............................................................................................. 7 1.5 Description of Test Mode .................................................................................................... 8 1.6 Description of Test Software Setting ................................................................................ 9 1.7 Measurement Uncertainty ................................................................................................ 10 1.8 Test Facility ......................................................................................................................... 11 2. TEST SUMMARY ..................................................................................................................... 12 3. TEST SOFTWARE ................................................................................................................... 12 4. TEST EQUIPMENT AND TEST SITE ................................................................................... 13 5. CONDUCTED EMISSION TEST ........................................................................................... 15 5.1 Test Standard and Limit .................................................................................................... 15 5.2 Test Setup ........................................................................................................................... 15 5.3 Test Procedure ................................................................................................................... 15 5.4 Deviation From Test Standard ......................................................................................... 16 5.5 EUT Operating Mode ........................................................................................................ 16 5.6 Test Data ............................................................................................................................. 16 6. RADIATED AND CONDUCTED UNWANTED EMISSIONS ............................................ 17 6.1 Test Standard and Limit .................................................................................................... 17 6.2 Test Setup ........................................................................................................................... 18 6.3 Test Procedure ................................................................................................................... 19 6.4 Deviation From Test Standard ......................................................................................... 20 6.5 EUT Operating Mode ........................................................................................................ 21 6.6 Test Data ............................................................................................................................. 21 7. RESTRICTED BANDS AND BAND EDGE REQUIREMENT .......................................... 22 7.1 Test Standard and Limit .................................................................................................... 22 7.2 Test Setup ........................................................................................................................... 22 7.3 Test Procedure ................................................................................................................... 23 7.4 Deviation From Test Standard ......................................................................................... 24 Report No.: TBR-C-202603-0361-1 Page: 3 of 36 www.cotecna-toby.com TB-RF-073-3.1 7.5 EU…

Text truncated - open the document above for the full version.

Contact Information

Applicant

David Santana(Purchase)
[email protected]Fax: N/A

Technical Contact

ACT Lab LLCScott Huber
[email protected]

3280 East 59th Street,Long Beach, · United States

Test Firm

Shenzhen Toby Technology Co., Ltd.Ray Lai
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz41.30 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is average conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.