2BVPX-DIANYILBHC001Remote control

GuangZhou DianYi DianZiShangWu Co., Ltd.
Remote control - FCC ID 2BVPX-DIANYILBHC001 - GuangZhou DianYi DianZiShangWu Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 21, 2026
Application Purpose
Original Equipment
Equipment Note
Remote control
Frequency Range
2412.00000000 - 2462.00000000
Company
GuangZhou DianYi DianZiShangWu Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Local Representative Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(7), of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2BVPX-DIANYILBHC001 DianYiLBHC001 We hereby acknowledge as follows: i.both signees confirm that the point of contact accepts responsibility to act as a US- American Representative on behalf of the applicant ii.the point of contact provides the physical U.S. address and email as listed below iii.both parties maintain the requirements of this agreement for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. iv.An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. US-American Point of Contact Applicant/Approval Holder Signature Date: 2026-5-18 Signature Date: 2026-5-18 Company Name: GLOCERTS TECHNOLOGY INC GuangZhou DianYi DianZiShangWu Co., Ltd. FRN: 0036339737 0038310496 Contact Name: Huiying Fan Xiaowei Wu Addres: 19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507 BaiYunQuJiChangLu657Hao101Pu, GuangZhouShi,GuangDong Sheng,China Phone: (626) 588-803913265371009 Email: [email protected] [email protected] 如ovvei W从

External Photos

Page 1 of 3 FCC ID: 2BVPX-DIANYILBHC001 External Photos Page 2 of 3 FCC ID: 2BVPX-DIANYILBHC001 Page 3 of 3 FCC ID: 2BVPX-DIANYILBHC001

ID Label/Location Info

Label FCC ID: 2BVPX-DIANYILBHC001

Internal Photos

Page 1 of 2 FCC ID: 2BVPX-DIANYILBHC001 Internal Photos PCB ANT Page 2 of 2 FCC ID: 2BVPX-DIANYILBHC001

RF Exposure Info

Page 1 of 8 Report No.: AiTSZ-260325017FW2 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited. If there is a need to alter or revise this document, the right belongs to Guangdong Asia Hongke Test Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. RF Exposure evaluation Product Name : Remote control Brand Name : TFZBA Model : DianYiLBHC001 Series Model : N/A FCC ID : 2BVPX-DIANYILBHC001 Applicant : GuangZhou DianYi DianZiShangWu Co., Ltd. Address : BaiYunQuJiChangLu657Hao101Pu,GuangZhouShi,GuangDong Sheng,China Manufacturer : GuangZhou DianYi DianZiShangWu Co., Ltd. Address : BaiYunQuJiChangLu657Hao101Pu,GuangZhouShi,GuangDong Sheng,China Standard(s) : 47CFR §1.1310, 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Date of Receipt : Mar. 25, 2026 Date of Test : Mar. 25, 2026~ May. 07, 2026 Issued Date : May. 07, 2026 Issued By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Reviewed by: Approved by: Nels Wang Allen Wang Page 2 of 8 Report No.: AiTSZ-260325017FW2 Report Revise Record Report Version Issued Date Notes M0 May. 07, 2026 Initial Release Page 3 of 8 Report No.: AiTSZ-260325017FW2 Contents 1 GENERAL INFORMATION .......................................................................................................................................... 4 1.1 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 4 1.2 GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 4 1.3 TEST FACILITY .............................................................................................................................................................. 5 1.4 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5 2 METHOD OF MEASUREMENT ................................................................................................................................... 6 2.1 APPLICABLE STANDARD.................................................................................................................................................. 6 2.2 LIMIT ......................................................................................................................................................................... 6 2.3 MPE CALCULATION METHOD ......................................................................................................................................... 7 2.4 MANUFACTURING TOLERANCE ........................................................................................................................................ 7 2.5 STANDALONE MPE RESULT ............................................................................................................................................ 8 2.6 CONCLUSION ............................................................................................................................................................... 8 Page 4 of 8 Report No.: AiTSZ-260325017FW2 1 GENERAL INFORMATION 1.1 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Normal Temperature: 25°C Relative Humidity: 55 % Air Pressure: 101 kPa 1.2 General Description of EUT Product Name: Remote control Model/Type reference: DianYiLBHC001 Serial Model: N/A Power Ratings DC 24V from adapter Adapter information: MODEL: HXS-2420 INPUT: AC110-240V 50/60Hz OUTPUT: DC 24V2A Hardware Version: N/A Software Version: N/A Sample(s) Status: AiTSZ-260325017-1(Normal sample) AiTSZ-260325017-2(Engineer sample) 2.4G WIFI: Supported type: 802.11b/802.11g /802.11n(HT20)/802.11n(HT40) Modulation: 802.11b(DSSS):CCK,DQPSK,DBPSK 802.11g(OFDM):BPSK,QPSK,16-QAM,64-QAM 802.11n(OFDM):BPSK,QPSK,16-QAM,64-QAM Operation frequency: 802.11b/802.11g/802.11n(HT20): 2412MHz~2462MHz 802.11n(HT40): 2422MHz~2452MHz Channel number: 802.11b/802.11g/802.11n(HT20): 11 802.11n(HT40): 7 Channel separation: 5MHz Antenna type: PCB Antenna Antenna gain: -2.44dBi Remark: The above DUT's information was declared by manufacturer. For more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Page 5 of 8 Report No.: AiTSZ-260325017FW2 1.3 Test Facility Test Laboratory: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China The test facility is recognized, certified or accredited by the following organizations: FCC-Registration No.: 251906 Designation Number: CN1376 Guangdong Asia Hongke Test Technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC —Registration No.: 31737 CAB identifier: CN0165 The 3m Semi-anechoic chamber of Guangdong Asia Hongke Test Technology Limited has been registered by Certification and Engineering Bure…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 31 Report No.: AiTSZ-260325017FW1 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited. If there is a need to alter or revise this document, the right belongs to Guangdong Asia Hongke Test Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. TEST REPORT Product Name : Remote control Brand Name : TFZBA Model : DianYiLBHC001 Series Model : N/A FCC ID : 2BVPX-DIANYILBHC001 Applicant : GuangZhou DianYi DianZiShangWu Co., Ltd. Address : BaiYunQuJiChangLu657Hao101Pu,GuangZhouShi,GuangDong Sheng,China Manufacturer : GuangZhou DianYi DianZiShangWu Co., Ltd. Address : BaiYunQuJiChangLu657Hao101Pu,GuangZhouShi,GuangDong Sheng,China Standard(s) : FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of Receipt : Mar. 25, 2026 Date of Test : Mar. 25, 2026~ May. 07, 2026 Issued Date : May. 07, 2026 Issued By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Reviewed by: Approved by: Nels Wang Allen Wang Page 2 of 31 Report No.: AiTSZ-260325017FW1 Report Revise Record Report Version Issued Date Notes M0 May. 07, 2026 Initial Release Page 3 of 31 Report No.: AiTSZ-260325017FW1 Contents 1 TEST SUMMARY ....................................................................................................................................................... 4 1.1 TEST STANDARDS ......................................................................................................................................................... 4 1.2 TEST SUMMARY ........................................................................................................................................................... 4 1.3 TEST FACILITY .............................................................................................................................................................. 5 1.4 MEASUREMENT UNCERTAINTY ........................................................................................................................................ 5 2 GENERAL INFORMATION .......................................................................................................................................... 6 2.1 ENVIRONMENTAL CONDITIONS ........................................................................................................................................ 6 2.2 GENERAL DESCRIPTION OF EUT ...................................................................................................................................... 6 2.3 DESCRIPTION OF TEST MODES AND TEST FREQUENCY .......................................................................................................... 7 2.4 SPECIAL ACCESSORIES ................................................................................................................................................... 8 2.5 EQUIPMENT LIST FOR THE TEST ....................................................................................................................................... 9 3 TEST CONDITIONS AND RESULTS ............................................................................................................................ 10 3.1 CONDUCTED EMISSIONS TEST ....................................................................................................................................... 10 3.2 RADIATED EMISSIONS AND BAND EDGE .......................................................................................................................... 13 3.3 MAXIMUM PEAK CONDUCTED OUTPUT POWER ............................................................................................................... 20 3.4 POWER SPECTRAL DENSITY .......................................................................................................................................... 21 3.5 6DB BANDWIDTH ....................................................................................................................................................... 22 3.6 OUT-OF-BAND EMISSIONS ........................................................................................................................................... 23 3.7 ANTENNA REQUIREMENT ............................................................................................................................................. 25 4 TEST SETUP PHOTOGRAPHS OF EUT ....................................................................................................................... 26 5 PHOTOS OF EUT ..................................................................................................................................................... 27 Page 4 of 31 Report No.: AiTSZ-260325017FW1 1 TEST SUMMARY 1.1 Test Standards The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz ANSI C63.10: 2020: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 15.247 Meas Guidance v05r02: Guidance for Compliance Measurements on Digital Transmission System, Frequency Hopping Spreda Spectrum System, and Hybrid System Devices Op…

Text truncated - open the document above for the full version.

Test Report

Antenna Study 1  Project Name : ZJ -BWCK-SPI- VC-3K  Debugging frequency band: 2400 ‐ 2500HMz  Valuation date : 2024.10.288 ADD: No. 101, Building 2, No. 9 Xinfa Road, Lincun, Tangxia, Dongguan, Guangdong, China PCB Antenna 2 Testing 3D microwave darkroom(6m*6m*6m) Testing environment PCB Antenna 3 Antenna • Antenna name: 2.4G • Antenna Type : PCB • Covers : 2400/2500MHz 4 S Parameter_Return Loss&VSWR‐Smith 5 Efficiency and Gain Frequency ID 1 2 3 4 5 6 7 8 9 10 11 Frequency (MHz) 2400.0 2410.0 2420.0 2430. 0 2440.0 2450.0 2460.0 2470.0 2480.0 2490.0 2500.0 Gain (dBi) -3.06 -3.84 -4.63 -5.25 -5.45 -5.72 -6.35 -6.59 -2.63 -2.44 -6.39 Efficiency (%) 17.13 15.69 12.86 10.75 9.64 9.11 8.44 7.58 6.51 5.63 5.03 2400.0MHz Total, Eff: 17.1%Back View2400.0MHz Total(E1-XZ), Max= -3.62dBi2400.0MHz Total(E2-YZ), Max= -5.51dBiTotal(H-XY), Max= -5.79dBi, CirD=10.78 -3.06 -4.9 -6.75 -8.59 -10.43 -12.27 -14.11 -15.96 -17.8 -19.64 -21.48 -23.32 -25.17 -27.01 -28.85 -30.69 -32.54 -34.38 2410.0MHz Total, Eff: 15.7%Back View2410.0MHz Total(E1-XZ), Max= -4.28dBi2410.0MHz Total(E2-YZ), Max= -5.60dBiTotal(H-XY), Max= -6.41dBi, CirD=10.16 -3.84 -5.68 -7.53 -9.37 -11.21 -13.05 -14.89 -16.74 -18.58 -20.42 -22.26 -24.1 -25.95 -27.79 -29.63 -31.47 -33.31 -35.16 2420.0MHz Total, Eff: 12.9%Back View2420.0MHz Total(E1-XZ), Max= -5.13dBi2420.0MHz Total(E2-YZ), Max= -6.44dBiTotal(H-XY), Max= -7.53dBi, CirD=10.15 -4.63 -6.47 -8.31 -10.15 -11.99 -13.84 -15.68 -17.52 -19.36 -21.21 -23.05 -24.89 -26.73 -28.57 -30.42 -32.26 -34.1 -35.94 2430.0MHz Total, Eff: 10.7%Back View2430.0MHz Total(E1-XZ), Max= -5.62dBi2430.0MHz Total(E2-YZ), Max= -7.38dBiTotal(H-XY), Max= -8.17dBi, CirD=11.23 -5.25 -7.09 -8.93 -10.78 -12.62 -14.46 -16.3 -18.14 -19.99 -21.83 -23.67 -25.51 -27.35 -29.2 -31.04 -32.88 -34.72 -36.57 2440.0MHz Total, Eff: 9.6%Back View2440.0MHz Total(E1-XZ), Max= -5.86dBi2440.0MHz Total(E2-YZ), Max= -7.77dBiTotal(H-XY), Max= -8.44dBi, CirD=12.60 -5.45 -7.29 -9.13 -10.97 -12.81 -14.66 -16.5 -18.34 -20.18 -22.03 -23.87 -25.71 -27.55 -29.39 -31.24 -33.08 -34.92 -36.76 2450.0MHz Total, Eff: 9.1%Back View2450.0MHz Total(E1-XZ), Max= -6.20dBi2450.0MHz Total(E2-YZ), Max= -7.90dBiTotal(H-XY), Max= -8.51dBi, CirD=12.81 -5.72 -7.56 -9.4 -11.25 -13.09 -14.93 -16.77 -18.61 -20.46 -22.3 -24.14 -25.98 -27.82 -29.67 -31.51 -33.35 -35.19 -37.03 2460.0MHz Total, Eff: 8.4%Back View2460.0MHz Total(E1-XZ), Max= -6.93dBi2460.0MHz Total(E2-YZ), Max= -8.28dBiTotal(H-XY), Max= -8.69dBi, CirD=11.40 -6.35 -8.2 -10.04 -11.88 -13.72 -15.57 -17.41 -19.25 -21.09 -22.93 -24.78 -26.62 -28.46 -30.3 -32.14 -33.99 -35.83 -37.67 2470.0MHz Total, Eff: 7.6%Back View2470.0MHz Total(E1-XZ), Max= -7.63dBi2470.0MHz Total(E2-YZ), Max= -8.79dBiTotal(H-XY), Max= -9.35dBi, CirD=9.33 -6.59 -8.44 -10.28 -12.12 -13.96 -15.8 -17.65 -19.49 -21.33 -23.17 -25.01 -26.86 -28.7 -30.54 -32.38 -34.23 -36.07 -37.91 2480.0MHz Total, Eff: 6.5%Back View2480.0MHz Total(E1-XZ), Max= -7.84dBi2480.0MHz Total(E2-YZ), Max= -9.76dBiTotal(H-XY), Max= -10.25dBi, CirD=7.86 -2.63 -4.47 -6.31 -8.16 -10 -11.84 -13.68 -15.52 -17.37 -19.21 -21.05 -22.89 -24.73 -26.58 -28.42 -30.26 -32.1 -33.95 2490.0MHz Total, Eff: 5.6%Back View2490.0MHz Total(E1-XZ), Max= -8.35dBi2490.0MHz Total(E2-YZ), Max= -10.61dBiTotal(H-XY), Max= -10.98dBi, CirD=8.31 -2.44 -4.28 -6.12 -7.96 -9.81 -11.65 -13.49 -15.33 -17.17 -19.02 -20.86 -22.7 -24.54 -26.38 -28.23 -30.07 -31.91 -33.75 2500.0MHz Total, Eff: 5.0%Back View2500.0MHz Total(E1-XZ), Max= -9.02dBi2500.0MHz Total(E2-YZ), Max= -10.97dBiTotal(H-XY), Max= -11.57dBi, CirD=9.35 -6.39 -8.23 -10.07 -11.92 -13.76 -15.6 -17.44 -19.28 -21.13 -22.97 -24.81 -26.65 -28.49 -30.34 -32.18 -34.02 -35.86 -37.7

Test Report

Page 1 of 47 Report No.: AiTSZ-260325017FW1 Appendix RF test data for WIFI2.4G Page 2 of 47 Report No.: AiTSZ-260325017FW1 1. Duty Cycle 1.1 Test Result 1.1.1 Ant1 Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) 802.11b SISO 2412 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2462 100.000 100.000 100.00 0.00 0.00 802.11g SISO 2412 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2462 100.000 100.000 100.00 0.00 0.00 802.11n (HT20) SISO 2412 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2462 100.000 100.000 100.00 0.00 0.00 802.11n (HT40) SISO 2422 100.000 100.000 100.00 0.00 0.00 2437 100.000 100.000 100.00 0.00 0.00 2452 100.000 100.000 100.00 0.00 0.00 Page 3 of 47 Report No.: AiTSZ-260325017FW1 1.2 Test Graph 1.2.1 Ant1 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV Page 4 of 47 Report No.: AiTSZ-260325017FW1 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV Page 5 of 47 Report No.: AiTSZ-260325017FW1 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV Page 6 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV Page 7 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_LCH_2422MHz_Ant1 (SISO)_NTNV Page 8 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT40)_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_HCH_2452MHz_Ant1 (SISO)_NTNV Page 9 of 47 Report No.: AiTSZ-260325017FW1 2. Bandwidth 2.1 Test Result 2.1.1 OBW Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit 802.11b SISO 2412 1 12.831 / Pass 2437 1 12.783 / Pass 2462 1 12.772 / Pass 802.11g SISO 2412 1 16.492 / Pass 2437 1 16.491 / Pass 2462 1 16.539 / Pass 802.11n (HT20) SISO 2412 1 17.645 / Pass 2437 1 17.570 / Pass 2462 1 17.609 / Pass 802.11n (HT40) SISO 2422 1 36.355 / Pass 2437 1 36.435 / Pass 2452 1 36.513 / Pass 2.1.2 6dB BW Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 802.11b SISO 2412 1 8.170 >=0.5 Pass 2437 1 8.166 >=0.5 Pass 2462 1 8.168 >=0.5 Pass 802.11g SISO 2412 1 16.142 >=0.5 Pass 2437 1 16.135 >=0.5 Pass 2462 1 16.234 >=0.5 Pass 802.11n (HT20) SISO 2412 1 17.340 >=0.5 Pass 2437 1 17.293 >=0.5 Pass 2462 1 17.372 >=0.5 Pass 802.11n (HT40) SISO 2422 1 35.678 >=0.5 Pass 2437 1 35.433 >=0.5 Pass 2452 1 35.815 >=0.5 Pass Page 10 of 47 Report No.: AiTSZ-260325017FW1 2.2 Test Graph 2.2.1 OBW 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV Page 11 of 47 Report No.: AiTSZ-260325017FW1 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV Page 12 of 47 Report No.: AiTSZ-260325017FW1 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV Page 13 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV Page 14 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_LCH_2422MHz_Ant1 (SISO)_NTNV Page 15 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT40)_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_HCH_2452MHz_Ant1 (SISO)_NTNV Page 16 of 47 Report No.: AiTSZ-260325017FW1 2.2.2 6dB BW 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV Page 17 of 47 Report No.: AiTSZ-260325017FW1 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV Page 18 of 47 Report No.: AiTSZ-260325017FW1 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV Page 19 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV Page 20 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_LCH_2422MHz_Ant1 (SISO)_NTNV Page 21 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT40)_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_HCH_2452MHz_Ant1 (SISO)_NTNV Page 22 of 47 Report No.: AiTSZ-260325017FW1 3. Maximum Conducted Output Power 3.1 Test Result 3.1.1 Power Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 802.11b SISO 2412 15.05 <=30 Pass 2437 15.26 <=30 Pass 2462 15.19 <=30 Pass 802.11g SISO 2412 14.44 <=30 Pass 2437 14.49 <=30 Pass 2462 14.26 <=30 Pass 802.11n (HT20) SISO 2412 14.54 <=30 Pass 2437 14.59 <=30 Pass 2462 14.37 <=30 Pass 802.11n (HT40) SISO 2422 14.78 <=30 Pass 2437 14.76 <=30 Pass 2452 14.65 <=30 Pass Note1: Antenna Gain: Ant1: -2.44dBi; Page 23 of 47 Report No.: AiTSZ-260325017FW1 4. Maximum Power Spectral Density 4.1 Test Result 4.1.1 PSD Mode TX Type Frequency (MHz) Maximum PSD (dBm) Verdict ANT1 Limit(dBm/3kHz) 802.11b SISO 2412 4.81dBm/100kHz <=8 Pass 2437 4.58dBm/100kHz <=8 Pass 2462 4.75dBm/100kHz <=8 Pass 802.11g SISO 2412 -6.50dBm/100kHz <=8 Pass 2437 -6.47dBm/100kHz <=8 Pass 2462 -6.06dBm/100kHz <=8 Pass 802.11n (HT20) SISO 2412 -6.08dBm/100kHz <=8 Pass 2437 -6.29dBm/100kHz <=8 Pass 2462 -6.81dBm/100kHz <=8 Pass 802.11n (HT40) SISO 2422 -9.39dBm/100kHz <=8 Pass 2437 -9.32dBm/100kHz <=8 Pass 2452 -9.72dBm/100kHz <=8 Pass Note1: Antenna Gain: Ant1: -2.44dBi; Page 24 of 47 Report No.: AiTSZ-260325017FW1 4.2 Test Graph 4.2.1 PSD 802.11b_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11b_MCH_2437MHz_Ant1 (SISO)_NTNV Page 25 of 47 Report No.: AiTSZ-260325017FW1 802.11b_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11g_LCH_2412MHz_Ant1 (SISO)_NTNV Page 26 of 47 Report No.: AiTSZ-260325017FW1 802.11g_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11g_HCH_2462MHz_Ant1 (SISO)_NTNV Page 27 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_LCH_2412MHz_Ant1 (SISO)_NTNV 802.11n(HT20)_MCH_2437MHz_Ant1 (SISO)_NTNV Page 28 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT20)_HCH_2462MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_LCH_2422MHz_Ant1 (SISO)_NTNV Page 29 of 47 Report No.: AiTSZ-260325017FW1 802.11n(HT40)_MCH_2437MHz_Ant1 (SISO)_NTNV 802.11n(HT40)_HCH_24…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 FCC ID: 2BVPX-DIANYILBHC001 Page 2 of 2 FCC ID: 2BVPX-DIANYILBHC001

Contact Information

Applicant

Xiaowei Wu
[email protected]Fax: 13265371009

Technical Contact

GLOCERTS TECHNOLOGY INCHuiying Fan
[email protected]

19784 SUNKISSED RIDGE DR · United States

Test Firm

Guangdong Asia Hongke Test Technology LimitedCoin Tang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz33.60 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.