Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 10, 2026
Application Purpose
Original Equipment
Equipment Note
AQPU PET SMART TRACKER
Frequency Range
2402.00000000 - 2480.00000000
Company
ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Product Name: AQPU PET SMART TRACKER Model No.: O-001 Charging & Power On This tracker has no power button. First time use: Charge for about 2 hours using the magnetic charging cable. The tracker will power on automatically while charging.  Charging: Red ring light stays ON.  Fully charged: Red ring turns OFF; small green light stays ON. Important:  Always use the original charging cable to ensure proper power-on and charging.  To prevent battery failure, charge the tracker at least once a month if not in use. Quick activation 1. Get the app. Scan the QR code to download the Aqpu app. 2. Sign up or log in. Open the app and create an account or log in. 3. Add your tracker. Enter the tracker ID or scan the QR code on the back. 4. Activate. Choose a subscription plan and follow the prompts. Note: A subscription is required for cellular connectivity, which enables real‑ time tracking. Add a pet 1. Tap Account on the bottom bar. 2. Select Pets, then tap Add New Pet. 3. Enter your pet's details and tap Save. Link tracker to pet You can link a tracker to a pet in two ways: From the Pets page Account > Pets > select a pet > Linked Tracker > choose a tracker From the Trackers page Account > Trackers > select a tracker > Linked Pet > choose a pet Get in touch Thank you for choosing Aqpu. We're committed to providing you with reliable support. If you have any questions, please reach out to us: Email: [email protected] Regulatory & Safety Information FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. Important Safety Instructions Medical Devices This product contains magnets and radio transmitters that may interfere with pacemakers, defibrillators, and other implanted medical devices. Maintain a minimum distance of 6 inches (15 cm) between the tracker and the medical device. Consult your physician and medical device manufacturer before use. Battery Safety This device contains a lithium-ion battery. Do not disassemble, crush, or puncture the device. Do not expose to fire or high temperatures. Use only the provided magnetic charging cable. Charge in a well-ventilated area. Discontinue use if the battery swells or overheats. Choking Hazard This device contains small components. Keep away from children and pets to prevent accidental swallowing. Disposal Please recycle the device and battery according to local laws and regulations. Do not dispose of in household waste. For support, contact: [email protected]

RF Exposure Info

         !"#$" %&'()*+&,-./011102033045670899:;,9-//&<&=&>?&1@(A)&BC DEFGHIJKL MNGEOOMINP Q RQIHKJ HS TJ RNFMUKOOIQFMRQNSVFNEIKNNE VQFNN MRRQIWOIUXYZ[DE FMUIQLNFIMJIMNFM HE Q FMFGNIP KG H IMO\UIQNE RKQRIG UIQVEFJEFNFGGKPLFNN HMHFGMINNIP Q O G HFMVEIO IQRQNVFNEIKNVQFNN MRRQIWOIUXYZ[     ] ^_`abcde`fb_  ghfei_cajk` l mabcde`gkeafn`fb_ l] o_apq^_barp`fb_sssssssssssssssssssssssssssssssssssssssssssssssssssssss  tpkdar_`t`ubcv ] `da_wbkkxdfar_`kssssssssssssssssssssssssssssssssssssssssssssssssssv  teup_fepqxdfar_`ksssssssssssssssssssssssssssssssssssssssssssssssssssv v tpkdar_`i_ea`pf_`yv v] `da_wbkkssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssv v gfr_kfb_tpkdar_`sssssssssssssssssssssssssssssssssssssssssssssssssssv vl zpqfcp`fb_tpkdar_`ssssssssssssssssssssssssssssssssssssssssssssssssssssv { pqf|ap`fb_tpkdar_`kdq`k{ {] `da_wbkkp_c^rncp_e^_}pcwfxdfcssssssssssssssssssssssssssssssssssss{ { `da_wbkkp_c^rncp_e^_bcywfxdfcssssssssssssssssssssssssssssssssssss{ {l teup_fepqgfr_kfb_kssssssssssssssssssssssssssssssssssssssssssssssssssss~ ~ zpqfcp`fb_rpkdar_`~ ~] }pcwfxdfctpkdar_`ssssssssssssssssssssssssssssssssssssssssssssssssss ~ tpkdar_`kdq`f`u}pcwfxdfcssssssssssssssssssssssssssssssssssss ~l bcywfxdfctpkdar_`sssssssssssssssssssssssssssssssssssssssssssssssss]] ~ tpkdar_`kdq`f`ubcywfxdfcssssssssssssssssssssssssssssssssss]  wfk`bxdfnr_`]l 3 9        !"#$% &'()*+,'-./01222131441567819::;<-:.00'='>'?@'2A)B*'CD EFGHIJKLM NOHFPPNJOQ R SRJILK IT UK SOGNVLPPJRGNSROTWGOFJLOOF WRGOO NSSRJXPJVYZ[\EF GNVJRMOGJNKJNOGN IF R GNGHOJQ LH I JNP]VJROF SLRSJH VJRWFGKFGOGHHLQMGOO INIGHNJOOJQ R P H IGNWFJP JRSROWGOFJLOWRGOO NSSRJXPJVYZ[\ ^  _  `abcdefghijfeijkbickcghhklmejalngblhijccjeljaomjapqprstuvwk id xyzrwrrzsvcjkidkldcelllifdb{e|cgcdelhkcglhijcmcjh }k|bdkjbeickidja hkcglhijcjakj~l{lelhdje}lbmjakjja{ledgfjfeh{|bc~bjaja elhijbeidcjkidkldc  € _  ‚ƒ„…‚†‡ˆ‚‰Š‚‹Œ z}bf`m{ŽvssŽx‘zp’“ ŽkigkfjgllŽ”• Žed|pzvss lbk|‘ghol ’ledgfjeidbjbei–i~qgcd—‘~ ˜  _    ™v•‘“p‘xŽ`p‘ Ž”•š›œž”k|bdkjbeizb{e|cklogb|jbikffeldkifjejapqprstuvwkid xyzrwrrz svcjkidkldc`a{ledgfjbcdcbŸidelgc~bjajaŽjcjoifa ei|m  ¡¢£¤^¥YZ[¦§Y§ ̈©ªZPGIOGJN«GSJP 3 t t 9 SN 30/14 DIP1G900-333        !"#$% &'()*+,'-./01222131441567819::;<-:.00'='>'?@'2A)B*'CD EFGHIJKLM NOHFPPNJOQ R SRJILK IT UK SOGNVLPPJRGNSROTWGOFJLOOF WRGOO NSSRJXPJVYZ[\EF GNVJRMOGJNKJNOGN IF R GNGHOJQ LH I JNP]VJROF SLRSJH VJRWFGKFGOGHHLQMGOO INIGHNJOOJQ R P H IGNWFJP JRSROWGOFJLOWRGOO NSSRJXPJVYZ[\ ^_`__a bcdedfghijklmnopqfkffqgjrslmnltnrutvwxntyzxt{msrvttt m| nxuv}rzrnvtr~rs{wl}xnlsxvm{lrzt{msrbcv}}vxm€{lrzt{msrtutvt{nsv wtx~s clsscutvnz|s|v{u}xrxscscvt{msxvmnrslmnltnr jb‚ƒ„…d†‚b bcnxuv}zrnvtr~rs{wl}xnlsxvm{lrzt{msrlmn|c|‡r{zrsclwltsztm}vrrvig nvtˆ sstbctsztm}vrr{lrzt{msrcl}}ˆutvt{nl€lxmrsl}xyzxnx}}n}lsuclmsv{‰ xscscuclm sv{|vmrstz|snlrvzs}xmnxmscvt{msxvmnrslmnltnrnxt|s{scvnxrzrn xsclmsvt‡lml} ~rtlmnxsr|l}xˆtlsxvm‡xs‰ˆvscxsclwl}xnd„jŠgk|l}xˆtlsxvm †‹‚dƒ…d†‚b bcdedfghijklmnopqfkffqgjrslmnltnrru|x~sc{|clmx|l}|v{uvmmsr lmnnx{mrxvŒŽ‘’“”•–—”–ŽŒ—–˜Ž•’™š–‘‘’—–›’Œ–ŽŒœ’žŸ’Œ|~lmnuclmsv{rc}} scx|‡mrrnumnmsbc„†„srsˆm|c{u}v~rl{{uclmsv{rc}}scx|‡mrrsctvt scnxuv}rrv}nvtzrxscsc„†„ srsˆm|c|v{u}~xscsctyzxt{msrrsvtscvtl {{uclmsv{rc}}scx|‡mrrnxt|s{scvnxr zrnxscld„jŠgk|l}xˆtlsn|l}xut _`_` ¡ }}zm|tslxmsxr}xrsnˆ}vtut rmslm¢ulmnnzm|tslxms~¢utrrnlsluutv¢x{ls}~schk£ |vmxnm|}w}zrxm€l|vwtl€l|s vtv‡¤‰stl|lˆ}svscdmstmlsxvml}}~||usn¥zxnrsv †lrzt{msm|tslxms~ kjb‚ƒ„ bcv}}vxm€zm|tslxmsxrluu}~svsctsztm}vrr{lrzt{ms ¦§ ̈©§ª«¬­®ª ̄°±®ª ̄§ ̄`ª«§¦²®³ª²¬ ́ª§²©¦ª ́μμ ggifggg†‹¶ggƒd‚ kqd†‚d„‚††‚b bcv}}vxm€zm|tslxmsxrluu}~svscnx{mrxvm{lrzt{msr §ª·² ̧¹ºº»°±®ª ̄§ ̄`ª«§¦²®³ª²¬ ́ª §ª·² ̧ gi¼gggg{{ ¼…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Report No.: psi2604010-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Appendix I Test Setup Photo FCC ID: 2BVQR-O-001 Spurious Radiation Emissions Test (<1G) Spurious Radiation Emissions Test (>1G) Page 2 of 2 Report No.: psi2604010-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Conducted emission Test ------End------

Test Setup Photos

SAR Setup photos for FCC ID: 2BVQR-O-001 Body Back side(separation distance is 0mm) Body Left side(separation distance is 0mm) Body Right side(separation distance is 0mm) Body Bottom side(separation distance is 0mm) Body Top side(separation distance is 0mm)

Test Report

TIME:2026/04/16 Customer: ZheJiang Shenchenkaidong Technology CO., Ltd Project: Pet Locator (Overseas Version) Antenna System: 4G&GPS&WIFI&BT Shenzhen DBT Telecommunication Technology CO.,LTD Antenna Test Report OTA-800 Brand: ETS Frequency Range: 370MHz-8.5GHz Functions: Passive and active testing; TRP and TIS testing for GSM, CDMA, 2G/3G/4G, WIFI, BT, and other standards. 5071C Brand: Agilent Frequency Range: 9KHz-8.5GHz Functions: Comprehensive passive antenna testing for 2G/3G/4G/BT/WIFI, etc. 8960 Brand: Agilent Frequency Range: 292MHz-2700GHz Functions: Meets the requirements for 2G/3G active testing. CMW500 Brand: Rohde & Schwarz Frequency Range: 70KHz-6GHz Functions: Comprehensive active antenna testing for 2G/3G/4G/BT/WIFI/NB-IoT, etc. Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 4G Matching of Wi-Fi Antenna and BT Antenna GPS Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 FreqEffiGain (MHz)(%)(dBi) 7009.38-6.92 71011.9-4.73 72012.65-4.05 73014.74-3.74 74014.52-4.07 75016.82-3.77 76016.71-4.13 77017.92-4.26 78017.96-4.64 79018.7-4.61 80020.43-4.27 81022.53-3.57 82017.11-4.26 83011.84-5.17 8406.55-7.4 8504.41-8.89 8602.67-10.94 8702.4-11.36 8801.77-12.69 8901.63-12.98 9001.31-13.74 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 FreqEffiGain (MHz)(%)(dBi) 171022.92-3.26 173025.02-2.89 175029.06-2.27 177031.62-1.82 179033.7-1.47 181038.32-0.94 183035.35-1.16 185036.97-1.08 187037.13-1.23 189033.65-1.99 191030.78-2.29 193027.24-2.68 195030.44-2.4 197028.33-2.46 199025.3-2.85 201024.37-2.9 203021.61-3.28 205020.68-3.87 207020.41-2.81 209018.76-3.28 211017.63-2.51 213018.77-2.02 215016.1-2.72 217015.85-3.74 219015.57-4.62 220015.54-4.8 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 FreqEffiGain (MHz)(%)(dBi) 156516.29-3.87 157017.91-3.6 157520.73-3.29 158020.13-3.52 158519.8-3.44 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 FreqEffiGain (MHz)(%)(dBi) 240048.291.6 241047.691.85 242044.551.79 243046.662.13 244048.752.5 245050.262.47 246048.541.84 247049.62.06 248047.851.98 249052.382.53 250046.082.17 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 FreqEffiGain (MHz)(%)(dBi) 240046.731.47 241049.851.88 242046.491.64 2430522.25 244049.762.21 245051.232.33 246045.51.79 247048.722.05 248045.791.71 249046.441.9 250043.651.88 Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯 TesteMTC2 TRP Result1865019150 Frequency (MHz)18551905 Txp Ave(dBm)12.6813.67 TesteMTC2 TIS Result1150 Frequency (MHz)1985 Sens Ave(dBm)-87.82 TesteMTC4 TRP Result2000020350 Frequency (MHz)17151750 Txp Ave(dBm)13.2612.57 TesteMTC4 TIS Result2350 Frequency (MHz)2150 Sens Ave(dBm)-85.44 TesteMTC5 TRP Result2045020600 Frequency (MHz)829844 Txp Ave(dBm)4.184.67 TesteMTC5 TIS Result2600 Frequency (MHz)889 Sens Ave(dBm)-80.89 TesteMTC12 TRP Result2303523155 Frequency (MHz)700.5712.5 Txp Ave(dBm)4.276.37 Test eMTC12 TIS Result5155 Frequency (MHz)742.5 Sens Ave(dBm)-85.93 TesteMTC66 TRP Result132022132623 Frequency (MHz)17151775.099 Txp Ave(dBm)13.5212.27 Test eMTC66 TIS Result67087 Frequency (MHz)2175.1 Sens Ave(dBm)-85.28 Conductive cloth attached to speaker magnet for grounding Separate routing of charging serial port cable and battery cable Shenzhen DBT Telecommunication Technology CO.,LTD R&D Department 让人人分享优质通讯

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 38 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2BVQR-O-001 On Behalf of ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD. AQPU PET SMART TRACKER Model No.: O-001 Prepared for : ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD. Address : 3rd Floor, Building 1, Hangzhou Bay joint Innovation Center, West Wuxing Road, Cao'e Street, Shangyu District, Shaoxing, Zhejiang, China Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2604010-C01-R03 Date of Receipt : April 16, 2026 Date of Test : April 16, 2026–June 4, 2026 Date of Report : June 4, 2026 Version Number : V0 Page 2 of 38 Report No.: psi2604010-C01-R03 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Pag e 1. Summary Of Standards And Results ------------------------------------------------------------------------- 6 1.1. Description of Standards and Results ------------------------------------------------------------------ 6 2. General Information ------------------------------------------------------------------------------------------------ 7 2.1. Description of Device (EUT) ------------------------------------------------------------------------------ 7 2.2. Accessories of Device (EUT) ----------------------------------------------------------------------------- 8 2.3. Tested Supporting System Details ---------------------------------------------------------------------- 8 2.4. Block Diagram of Connection Between EUT and Simulators ------------------------------------ 8 2.5. Test Mode Description -------------------------------------------------------------------------------------- 9 2.6. Software test version and power setting information ----------------------------------------------- 9 2.7. Test Conditions ----------------------------------------------------------------------------------------------- 9 2.8. Test Facility ---------------------------------------------------------------------------------------------------- 9 2.9. Measurement Uncertainty -------------------------------------------------------------------------------- 10 2.10. Test Equipment List ---------------------------------------------------------------------------------------- 11 3. Spurious Emission ------------------------------------------------------------------------------------------------ 12 3.1. Test Limits ---------------------------------------------------------------------------------------------------- 12 3.2. Block Diagram of Test setup ----------------------------------------------------------------------------- 13 3.3. Test Procedure ---------------------------------------------------------------------------------------------- 14 3.4. Test Results -------------------------------------------------------------------------------------------------- 15 4. Power Line Conducted Emission ----------------------------------------------------------------------------- 20 4.1. Test Limits ---------------------------------------------------------------------------------------------------- 20 4.2. Test Procedure ---------------------------------------------------------------------------------------------- 20 4.3. Test Setup ---------------------------------------------------------------------------------------------------- 20 4.4. Test Results -------------------------------------------------------------------------------------------------- 21 5. Out-of-band Emissions ------------------------------------------------------------------------------------------ 24 5.1. Test Limits ---------------------------------------------------------------------------------------------------- 24 5.2. Test Procedure ---------------------------------------------------------------------------------------------- 24 5.3. Test Setup ---------------------------------------------------------------------------------------------------- 24 5.4. Test Results -------------------------------------------------------------------------------------------------- 24 6. Conducted Maximum Output Power ------------------------------------------------------------------------ 27 6.1. Test limits ----------------------------------------------------------------------------------------------------- 27 6.2. Test Procedure ---------------------------------------------------------------------------------------------- 27 6.3. Test Setup ---------------------------------------------------------------------------------------------------- 27 6.4. Test Results -------------------------------------------------------------------------------------------------- 27 7. Peak Power Spectral Density ---------------------------------------------------------------------------------- 30 7.1. Test limits ----------------------------------------------------------------------------------------------------- 30 7.2. Test Procedure ---------------------------------------------------------------------------------------------- 30 7.3. Test Setup ---------------------------------------------------------------------------------------------------- 30 7.4. Test Results -------------------------------------------------------------------------------------------------- 30 8. Occupied Bandwidth ---------------------------------------------------------------------------------------------- 32 8.1. Test limits ----------------------------------------------------------------------------------------------------- 32 8.2. Test Procedure -------------…

Text truncated - open the document above for the full version.

Test Report

Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 58 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China FCC TEST REPORT FCC ID: 2BVQR-O-001 On Behalf of ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD. AQPU PET SMART TRACKER Model No.: O-001 Prepared for : ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD. Address : 3rd Floor, Building 1, Hangzhou Bay joint Innovation Center, West Wuxing Road, Cao'e Street, Shangyu District, Shaoxing, Zhejiang, China Prepared By : Shenzhen PSI Testing Co., Ltd. Address : 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number : psi2604010-C01-R02 Date of Receipt : April 16, 2026 Date of Test : April 16, 2026–June 4, 2026 Date of Report : June 4, 2026 Version Number : V0 Page 2 of 58 Report No.: psi2604010-C01-R02 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China TABLE OF CONTENTS Description Pag e 1. Summary Of Standards And Results ------------------------------------------------------------------------- 6 1.1. Description of Standards and Results ------------------------------------------------------------------ 6 2. General Information ------------------------------------------------------------------------------------------------ 7 2.1. Description of Device (EUT) ------------------------------------------------------------------------------ 7 2.2. Accessories of Device (EUT) ----------------------------------------------------------------------------- 8 2.3. Tested Supporting System Details ---------------------------------------------------------------------- 8 2.4. Block Diagram of Connection Between EUT and Simulators ------------------------------------ 8 2.5. Test Mode Description -------------------------------------------------------------------------------------- 9 2.6. Software test version and power setting information ----------------------------------------------- 9 2.7. Test Conditions ---------------------------------------------------------------------------------------------- 10 2.8. Test Facility --------------------------------------------------------------------------------------------------- 10 2.9. Measurement Uncertainty -------------------------------------------------------------------------------- 10 2.10. Test Equipment List ---------------------------------------------------------------------------------------- 11 3. Spurious Emission ------------------------------------------------------------------------------------------------ 12 3.1. Test Limits ---------------------------------------------------------------------------------------------------- 12 3.2. Block Diagram of Test setup ----------------------------------------------------------------------------- 13 3.3. Test Procedure ---------------------------------------------------------------------------------------------- 14 3.4. Test Results -------------------------------------------------------------------------------------------------- 15 4. Power Line Conducted Emission ----------------------------------------------------------------------------- 21 4.1. Test Limits ---------------------------------------------------------------------------------------------------- 21 4.2. Test Procedure ---------------------------------------------------------------------------------------------- 21 4.3. Test Setup ---------------------------------------------------------------------------------------------------- 21 4.4. Test Results -------------------------------------------------------------------------------------------------- 22 5. Out-of-band Emissions ------------------------------------------------------------------------------------------ 25 5.1. Test Limits ---------------------------------------------------------------------------------------------------- 25 5.2. Test Procedure ---------------------------------------------------------------------------------------------- 25 5.3. Test Setup ---------------------------------------------------------------------------------------------------- 25 5.4. Test Results -------------------------------------------------------------------------------------------------- 25 6. Conducted Maximum Output Power ------------------------------------------------------------------------ 36 6.1. Test limits ----------------------------------------------------------------------------------------------------- 36 6.2. Test Procedure ---------------------------------------------------------------------------------------------- 36 6.3. Test Setup ---------------------------------------------------------------------------------------------------- 36 6.4. Test Results -------------------------------------------------------------------------------------------------- 36 7. Peak Power Spectral Density ---------------------------------------------------------------------------------- 43 7.1. Test limits ----------------------------------------------------------------------------------------------------- 43 7.2. Test Procedure ---------------------------------------------------------------------------------------------- 43 7.3. Test Setup ---------------------------------------------------------------------------------------------------- 43 7.4. Test Results -------------------------------------------------------------------------------------------------- 43 8. Occupied Bandwidth ---------------------------------------------------------------------------------------------- 47 8.1. Test limits ----------------------------------------------------------------------------------------------------- 47 8.2. Test Procedure -------------…

Text truncated - open the document above for the full version.

RF Exposure Info

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Shenzhen STS Test Services Co., Ltd. SAR Test Report Report No.: STS2605083H01 Issued for ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD. 3rd Floor, Building 1, Hangzhou Bay joint Innovation Center, West Wuxing Road, Cao’e Street, Shangyu District, Shaoxing, Zhejiang, China Product Name: AQPU PET SMART TRACKER Brand Name: AQPU Model Name: O-001 Series Model(s): N/A FCC ID: 2BVQR-O-001 Test Standard: ANSI/IEEE Std. C95.1 FCC 47 CFR Part 2 (2.1093) IEEE Std. 1528-2013 Max. Report SAR (1g) Body: 0.864 W/kg Page 2 of 62 Report No.: STS2605083H01 TEST REPORT CERTIFICATION Applicant’s name ................. : ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD. Address ................................. : 3rd Floor, Building 1, Hangzhou Bay joint Innovation Center, West Wuxing Road, Cao’e Street, Shangyu District, Shaoxing, Zhejiang, China Manufacturer's Name .......... : ZHEJIANG SHENCHEN KAI DONG TECHNOLOGY CO., LTD. Address ................................. : 3rd Floor, Building 1, Hangzhou Bay joint Innovation Center, West Wuxing Road, Cao’e Street, Shangyu District, Shaoxing, Zhejiang, China Product description Product name ........................ : AQPU PET SMART TRACKER Brand name ......................... : AQPU Model name ......................... : O-001 Series Model .......................... : N/A Standards ............................. : ANSI/IEEE Std. C95.1 FCC 47 CFR Part 2 (2.1093) IEEE Std. 1528-2013 The device was tested by Shenzhen STS Test Services Co., Ltd. in accordance with the measurement methods and procedures specified in KDB 865664 The test results in this report apply only to the tested sample of the stated device/equipment. Other similar device/equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Date of Test ........................................... : Date (s) of performance of tests ............. : 03 Jun. 2026 Date of Issue .......................................... : 12 Jun. 2026 Test Result.............................................. : Pass Testing Engineer : (Xin.Liu) Technical Manager : (Eric. Zhou) Authorized Signatory : (Bovey Yang) Page 3 of 62 Report No.: STS2605083H01 Table of Contents 1. General Information 5 1.1 EUT Description 5 1.2 Test Environment 6 1.3 Test Factory 6 2. Test Standards and Limits 7 3. SAR Measurement System 8 3.1 Definition of Specific Absorption Rate (SAR) 8 3.2 SAR System 8 4. Tissue Simulating Liquids 11 4.1 Simulating Liquids Parameter Check 11 5. SAR System Validation 14 5.1 Validation System 14 5.2 Validation Result 14 6. SAR Evaluation Procedures 15 7. EUT Test Position 16 8. Uncertainty 17 8.1 Measurement Uncertainty 17 10. Conducted Power Measurement 20 10.1 Test Result 20 11. EUT and Test Setup Photo 30 11.1 EUT Photo 30 11.2 Setup Photo 33 12. SAR Result Summary 37 12.1 Body-worn SAR 37 12.2 Simultaneous Multi-band Transmission Evaluation 38 13. Equipment List 39 Appendix A. System Validation Plots 40 Appendix B. SAR Test Plots 50 Appendix C. Probe Calibration and Dipole Calibration Report 62 Page 4 of 62 Report No.: STS2605083H01 Revision History Rev. Issue Date Report No. Effect Page Contents 00 12 Jun. 2026 STS2605083H01 ALL Initi…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Haoquan Huang(Software Engineer)
[email protected]Fax: N/A

Technical Contact

HOPEK CORPORATION INCYangyang Xu
[email protected]

16755 Coyote Bush Dr Unit 84 · CA · United States

Test Firm

Shenzhen PSI Testing Co., Ltd.Simple Guan
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz7.05 mW
215C2.43 GHz - 2.43 GHz750.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. Highest reported SAR for Body-worn accessory and simultaneous transmission are 0.06W/kg,0.93W/kg respectively.