Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ProductManual HA-F834RemoteControl 1.ProductOverview ThisproductisawirelessRFremotecontrol(transmitter)operatinginthe 433 MHzband.Itusesasurfaceacousticresonatorforfrequencystabilization combinedwithanadvancedencodingIC,offeringhighfrequencystability,low powerconsumption,longtransmissiondistance,andstrongwallpenetration. Thislow-powerremotecontrolissuitableforshort-rangewirelesscontrol applications. ProductName:GeneralPurposeEngineRemoteControl Model:F834 ProductAppearance: 2.MainTechnicalParameters ParameterValue ProductDimensions:60mm*29.5mm*12mm(L×W×H) OperatingTemperature:-20°C~60°C OperatingVoltage: DC6V OperatingCurrent: <10mA StandbyCurrent: <1uA EncodingMethod: 1527 TransmissionDistance: 50 m(openarea) BatteryType: CR2016coincell× 2 3.WirelessTechnicalSpecifications(433 MHz) ItemSpecification OperatingFrequency433.92MHz ModulationOOK TransmitPower<-80dBm AntennaTypePCBantenna 4.RemoteControlInstructions ThisremotecontrolcanbepairedwiththeHA-0806,HA-0807,or HA-0808seriesgeneralpurposeenginemodules.Afterpairing,whenthe moduleisconnectedtoa12 Vpowersupply,itentersstandbymode.When theONbuttonontheremotecontrolispressed,a433 MHzstartsignalis transmittedviathehigh-frequencytransmissioncircuit.Theremotecontrol hostreceivesthis433 MHzsignalthroughitsantenna;themicrocontroller(CPU) decodesandanalyzesthesignal.Uponrecognizingastartcommand,thehost outputsastartsignalandgraduallyrotatesthesteppermotortoopentheair door,thencheckswhetherthegasolinegeneratorhasstartedsuccessfully. Conversely,whentheOFFbuttonontheremotecontrolispressedtosenda stopsignal,andafterconfirmingthatthegasolinegeneratorisrunning,the microcontroller(CPU)outputsastopsignaltoshutdownthegenerator.The steppermotorthenrotatestoclosetheairdoor. 5.Precautions Donotuseinametal-shieldedenvironment,asthismayreducethe remotecontroldistance. Avoidheavypressure,dropping,orimmersioninwater. Iftheremotecontroldistancebecomesnoticeablyshorter,checkthe batterylevelorwhetherthereisastronginterferencesource. FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Local Representative Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(7), of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC IDModel name 2BVS5-HA-F834HA-F834, HA-0806, HA-0807, HA-0808 We hereby acknowledge as follows: i.both signees confirm that the point of contact accepts responsibility to act as a US- American Representative on behalf of the applicant ii.the point of contact provides the physical U.S. address and email as listed below iii.both parties maintain the requirements of this agreement for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. iv.An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. US-American Point of ContactApplicant/Approval Holder Signature Date: 2026-4-27 Signature Date: 2026-4-27 Company Name:GLOCERTS TECHNOLOGY INCChongqing Hao'ai Technology Development Co., Ltd. FRN:00363397370038335428 Contact Name:Huiying FanWang zhihao Address:19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507 United States No. 11 Baihai Road, Baishi Yi Town, Jiulongpo District, Chongqing China Phone:(626) 588-803917782053007 Email:[email protected]@189.cn
Page 1 of 3 FCC ID: 2BVS5-HA-F834 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China External Photos Photo 1 Photo 2 Page 2 of 3 FCC ID: 2BVS5-HA-F834 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 Page 3 of 3 FCC ID: 2BVS5-HA-F834 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Photo 5 Photo 6 ------End------
Label FCC ID: 2BVS5-HA-F834
Page 1 of 2 FCC ID: 2BVS5-HA-F834 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Internal Photos Photo 1 Photo 2 433.92 Antenna Page 2 of 2 FCC ID: 2BVS5-HA-F834 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Photo 3 Photo 4 ------End------
Page 1 of 8 Report No.: AiTDG-260323015W2 Note: This device has been tested and found to comply with the standard(s) listed, this test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited. If there is a need to alter or revise this document, the right belongs to Guangdong Asia Hongke Test Technology Limited, and it should give a prior written notice of the revision document. This test report must not be used by the client to claim product endorsement. Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao’an District, Shenzhen, Guangdong, China RF Exposure evaluation Product Name: Remote control for the machine Brand Name: N/A Model: HA-F834 Series Model: HA-0806, HA-0807, HA-0808 FCCID: 2BVS5-HA-F834 Applicant: Chongqing Hao'ai Technology Development Co., Ltd. Address: No. 11 Baihai Road, Baishi Yi Town, Jiulongpo District, Chongqing China Manufacturer: Chongqing HaoAi tech Development Co., Ltd Address: No.6-2,lishuwan,Shapingba District,Chongqing China Standard(s): 47CFR §1.1310,47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Date of Receipt: Mar. 23, 2026 Date of Test: Mar. 23, 2026~Apr. 01, 2026 Issued Date: Apr. 02, 2026 Issued By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Reviewed by: Approved by: Aalen.Ye Allen Wang Page 2 of 8 Report No.: AiTDG-260323015W2 Report Revise Record Report VersionIssued DateNotes V1.0Apr. 02, 2026Initial Release Page 3 of 8 Report No.: AiTDG-260323015W2 Contents 1GENERAL INFORMATION............................................................................................................................4 1.1ENVIRONMENTAL CONDITIONS....................................................................................................................4 1.2GENERAL DESCRIPTIONOF EUT.................................................................................................................4 1.3TEST FACILITY..........................................................................................................................................6 1.4MEASUREMENT UNCERTAINTY....................................................................................................................7 2METHOD OF MEASUREMENT.....................................................................................................................8 2.1APPLICABLE STANDARD.............................................................................................................................8 2.2LIMIT........................................................................................................................................................8 2.3MPE CALCULATION METHOD.....................................................................................................................9 2.4MANUFACTURING TOLERANCE...................................................................................................................9 2.5STANDALONE MPE RESULT.....................................................................................................................10 2.6CONCLUSION..........................................................................................................................................11 Page 4 of 8 Report No.: AiTDG-260323015W2 1GENERAL INFORMATION 1.1Environmental conditions During the measurement the environmental conditions were within the listed ranges: Normal Temperature:25°C Relative Humidity:55 % Air Pressure:101 kPa 1.2General Descriptionof EUT Product Name:Remote control for the machine Model/Type reference:HA-F834 Serial Model:HA-0806, HA-0807, HA-0808 Model difference: All the models are the same, only the model names and colors are different. Power Supply:DC 6V(2*3V “CR2016” battery) Hardware version.: N/A Software version.: N/A Test sample(s) ID: AiTDG-260323015-1 SRD 433.92: Operation frequency:433.92MHz ModulationTechnology : OOK Antenna Type: PCB Antenna Antenna Gain: 0dBi Remark: The above DUT's information was declared by manufacturer. For more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Page 5 of 8 Report No.: AiTDG-260323015W2 1.3Test Facility TestLaboratory: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China The test facility is recognized, certified or accredited by the following organizations: FCC-Registration No.: 251906 Designation Number: CN1376 Guangdong Asia Hongke Test Technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC-Registration No.: 31737 CAB identifier: CN0165 The 3m Semi-anechoic chamber of Guangdong Asia Hongke Test Technology Limited has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 31737 A2LA-Lab Cert. No.: 7133.01 Guangdong Asia Hongke Test Technology Limited has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing. Page 6 of 8 Report No.: AiTDG-260323015W2 1.4Measurement uncertainty The data and results referenced in this document are true and…
Text truncated - open the document above for the full version.
Page 1 of 31 Report No.: AiTDG-260323015W1 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Test Report Client Information: Applicant: Chongqing Hao'ai Technology Development Co., Ltd. Applicant add.: No. 11 Baihai Road, Baishi Yi Town, Jiulongpo District, Chongqing China Product Information: Product Name:Remote control for the machine Model No.:HA-F834 Brand Name:N/A FCC ID:2BVS5-HA-F834 Standards: FCC 47 CFR PART 15 SUBPART C 15.231 Prepared By: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Tel.: +86 0755-230967639 Fax.: +86 0755-230967639 Date of Receipt: Mar. 23, 2026Date of Test: Mar. 23, 2026~Apr. 01, 2026 Date of Issue: Apr. 02, 2026Test Result: Pass This device described above has been tested by Guangdong Asia Hongke Test Technology Limited, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Guangdong Asia Hongke Test Technology Limited. Reviewed by: Approved by: Aalen.Ye Allen Wang Page 2 of 31 Report No.: AiTDG-260323015W1 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 1Contents Page COVER PAGE 1CONTENTS2 2TEST SUMMARY4 2.1STATEMENT OF THE MEASUREMENT UNCERTAINTY4 2.2MEASUREMENT UNCERTAINTY4 3TEST FACILITY5 3.1DEVIATION FROM STANDARD5 3.2ABNORMALITIES FROM STANDARD CONDITIONS5 3.3TEST LOCATION5 4GENERAL INFORMATION6 4.1GENERAL DESCRIPTION OF EUT6 5DESCRIPTION OF TEST CONDITIONS8 5.1E.U.T. OPERATION8 5.2EUT PERIPHERAL LIST9 5.3TEST PERIPHERAL LIST9 6EQUIPMENTS LIST FOR ALL TEST ITEMS10 7TEST RESULT12 7.1ANTENNA REQUIREMENT12 7.2TRANSMIT TIME13 7.2.1Applied procedures / Limit13 7.2.2Test procedure13 7.2.3Deviation from standard13 7.2.4Test setup13 7.2.5Test results14 7.3FIELD STRENGTH OF FUNDAMENTAL& FIELD STRENGTH OF UNWANTED EMISSIONS15 7.3.1Test procedure18 7.4OCCUPIED BANDWIDTH & BAND EDGE27 7.5CONDUCTED EMISSIONS AT MAINS TERMINALS 150 KHZ TO 30 MHZ29 7.5.1Test Result31 8PHOTOGRAPHS31 8.1RADIATED EMISSION TEST SETUP31 Page 3 of 31 Report No.: AiTDG-260323015W1 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Report Revise Record Report VersionRevise TimeIssued DateValid VersionNotes V1.0/Apr. 02, 2026ValidInitial release Page 4 of 31 Report No.: AiTDG-260323015W1 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 2Test Summary FCC RuleDescription of TestResult Section 15.203 RSS-Gen section 6.8 Antenna Requirement Pass Section 15.207(a)Conduction Emissions N/A Section 15.205,15.209,15.231(b) Radiated Emissions Pass Section 15.231(c)Occupied Bandwidth Pass Section 15.231(a)Transmit time Pass Note 1. Test according to ANSI C63.10:2020. 2. The measurement uncertainty is not included in the test result. 3. Test results in other test report (RF Exposure Evaluation Report) 2.1Statement of the Measurement Uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4 “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC Measurements” and is documented in the AiT quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. 2.2Measurement Uncertainty Test ItemFrequency RangeMeasurement UncertaintyNotes Radiated Emission0.009MHz-30MHz3.10dB(1) Radiated Emission30MHz-1GHz3.75dB(1) Radiated Emission1GHz-18GHz3.88dB(1) Radiated Emission18GHz-40GHz3.88dB(1) AC Power Line Conducted Emission 0.15MHz ~ 30MHz1.20dB(1) Occupied Channel Bandwidth0.009MHz-18GHz0.20dB(1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Page 5 of 31 Report No.: AiTDG-260323015W1 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 3Test Facility The test facility is recognized, certified or accredited by the following organizations: Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China The test facility is recognized, certified or accredited by the following organizations: FCC-Registration No.: 251906 Designation Number: CN1376 Guangdong Asia Hongke Test Technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. IC-Registration No.: 31737 CAB identifier: CN0165 The 3m Semi-anechoic chamber of Guangdong Asia Hongke Test Technology Limited has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 31737 A2LA-Lab Cert. No.: 7133.01 Guangdong Asia Hongke Test Technology Limited has been accredited by A2LA for technical competence in the field of electrical testing, and proved…
Text truncated - open the document above for the full version.
ANTENNASPECIFICATION Summary ITEMANT SPEC Model NameSRD ANT AntennaplatePCB antenna Center Frequency 433.92MHz MAX. Gain0dBi PolarizationHorizontaland Vertical Impedance50Ohm Manufacture ChongqingHaoAitech DevelopmentCo., Ltd Address No.6-2,lishuwan,Shapingba District,ChongqingChina AntennaPhoto Length43mmandwidth22mm Frequency (MHz) Gain(dBi) HorizontalVertical Max.MinMax.Min 433.920.00-33.86-0.11-33.99
Page 1 of 1 FCC ID: 2BVS5-HA-F834 Guangdong Asia Hongke Test Technology Limited B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Test Setup Photo Radiated Emission ------End------
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |