Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
HyperionSim LLC Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 [April 23, 2026] U.S. Agent Designation [HyperionSim LLC] acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought FCC ID: 2BVSR-V4RX Name and company of U.S. agent: [GLOCERTS TECHNOLOGY INC] Physical U.S. address of agent: [19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507] FRN of U.S. agent: [0036339737] Email address of U.S. agent: [[email protected]] Telephone of U.S.agent: (626) 588-8039 [GLOCERTS TECHNOLOGY INC] acknowledges their obligation to accept service of process on behalf of [HyperionSim LLC]. [HyperionSim LLC] with the FRN [0038334868] accepts its obligation to maintain an agent for service of process in the United States for no less than 1 year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. Sincerely, Signature Signature [Wei shang] [Huiying Fan] [CEO] [Director] [HyperionSim LLC] [GLOCERTS TECHNOLOGY INC]
HyperionSim LLC 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: HyperionSim LLC Address: 32268 Corte Sabrinas, Temecula, CA 92592, USA Product Name: Hyper Fusion Transmitter FCC ID: 2BVSR-V4RX Model(s): V4RX 2.911(d)(5)(i) Equipment Type We, [HyperionSim LLC] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Wei shang Date: April 23, 2026 Title and Company name: CEO / HyperionSim LLC NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
HyperionSim LLC 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: HyperionSim LLC Address: 32268 Corte Sabrinas, Temecula, CA 92592, USA Product Name: Hyper Fusion Transmitter FCC ID: 2BVSR-V4RX Model(s): V4RX 2.911(d)(5)(ii) Applicant filing We, [HyperionSim LLC] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Wei shang Date: April 23, 2026 Title and Company name: CEO / HyperionSim LLC NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
FCC Software Configuration Control Declaration Rev1.1 HyperionSim LLC FCC Software Configuration Control Declaration Date: 2026.04.23 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: Hyper Fusion Transmitter / V4RX Regarding FCC Country Code Selection guidelines identified in KDB 594280. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Name: Wei shang Date: 2026.04.23 Title: CEO Signatureof applicant
HyperionSim LLC Agent Authorization Company: HyperionSim LLC Address: 32268 Corte Sabrinas, Temecula, CA 92592, USA Product Name: Hyper Fusion Transmitter Model Number(s): V4RX Product Description: Hyper Fusion Transmitter We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: April 23, 2026 Name: Wei shang Title: CEO Company: HyperionSim LLC
HyperionSim LLC Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: April 23, 2026 Subject; Request for Confidentiality FCC ID: 2BVSR-V4RX To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description FCC Software Security Requirements for UNII devices Rev 2.1 In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Wei shang Title: CEO
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 5 Model: V4RX External Photos WIFI ANT1 WIFI ANT2 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 5 of 5
FCC ID LABEL: Label Location: FCC ID: 2BVSR-V4RX Model No.: V4RX
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 5 Model: V4RX Internal Photos Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 5 Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 5 of 5 BT ANT
FCC §15.247 (i), §2.1091 – RF Exposure FCC ID: 2BVSR-V4RX Applied procedures / limit According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Note: ƒ is frequency in MHz * = Power density limit is applicable at frequencies greater than 100 MHz Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm 2 ) Averaging Time |E| 2 ,|H| 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1.0 30 Note: f = frequency in MHz * = Plane-wave equivalent power density MPE PREDICTION Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01 Where: S = power density P = power input to antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna,R=20cm Test Result of RF Exposure Evaluation Modes& Channel Freq. (MHz) Tune up Produce power Maximu m peak output power (dBm) Output power to antenna (mW) Antenna Gain (numeric) Power Density (S) (mW/ cm2) Limit (mW / cm2 ) Result EDR π/4DQPS K& MCH 0±1 1 1.2589 1.9770 (2.96dBi) 0.0005 1 Pass 5.8GWIFI ANT1 802.11n(H T20)& 5745 14±1 15 31.6228 1.2023 (0.8dBi) 0.0076 1 Pass 5.8GWIFI ANT2 802.11a&5 825 13±1 14 25.1189 1.2023 (0.8dBi) 0.006 1 Pass For the Max simultaneous transmission MPE: When a number of sources at different frequencies, and/or broadband sources, contribute to the total exposure, it becomes necessary to weigh each contribution relative to the MPE in accordance with the provisions of Table (A) and Table (B). To comply with the MPE, the fraction of the MPE in terms of E2, H2 (or power density) incurred within each frequency interval should be determined and the sum of all such fractions should not exceed unity. In order to ensure compliance with the MPE for a controlled environment, the sum of the ratios of the power density to the corresponding MPE should not exceed unity. That is BT+WIFI supported simultaneous transmission: EDR +5GWIFI MIMO: ∑MPE Ratio =0.0005/1+0.0136/1=0.0141≤1, So passed. Tech nolo gy Tune up Produce power(dBm) Maximum Tune-up (dBm) Antenna Gain(ANT 1/ANT 2) (numeric) Power Density (S) (mW/ cm2) MPE Limit (mW/ cm2) ∑ MPE Ratio ∑ MPE Ratio Limit Result ANT 1 ANT 2 ANT 1 ANT 2 ANT 1 ANT 2 5G WIFI MIM O 14 ±1 13 ±1 15 14 1.2023 (0.8dBi) 0.0076 0.006 1 0.0136 1 Pass
客户 CUSTOMER: 客户料号 5.8G圆极化天线 5.8GHz Circularly polarized antenna PART NAME: 供方料号 SUPPLIER NO: ANT-LHCP5.8-RPSMA 送样日期Date: 送样数量Q“TY: 供方确认SUPPLIER SIGNATURE APPROVALCHECKDESIGN 客户确认CUSTOMER APPROVED BY APPROVALCHIEFSUPERVISOR 日期2026/04/15 Date 编号260401B File No 版本1.0 Revision 规格承认书 SPECIFICATION FOR APPROVAL 品名 承认书项目表 NO. 内容 (Contents) 页数 (Number of Page) 页码 (Page Code) 1 承认书封面(Spec Cover) 11 2 承认书项目表(Spec Item ) 12 3 工程成品图(Drawing) 13 4 天线规格(Antenna Specification) 14 5 S参数测试(S Parameter ) 15 6 无源测试(Passive Test ) 26~7 7 天线辐射场型(Antenna Radiation Pattern) 28~9 8 天线图片(Antenna Profile) 110 9--- 10--- 11--- 12--- 工程成品图 Drawing 天线规格 Antenna Specification Electrical Properties Frequency 5725~5850MHz Impedance 50 Ohm Nominal V.S.W.R ≤3.5(Max) Return Loss ≤-10(Max) Radiation Omni-directional Gain (Peak) ≤1.0dBi(Max) Polarization Omnidirectional ConnectorIPEX Physical Properties Antenna MaterialABS Cable TypeRG-137 Operating Temp.-10 ~ +60 ̊C Storage Temp.-10 ~ +70 ̊C Cable Colorblack Agilent E5071C S Parameter Test // WIFI Antenna Performance Test Antenna Passive Test Passive Test For Antenna(5725-5850Mhz) Freq (MHz) Effi (%) Gain (dBi) 572533.180.72 575034.360.75 585038.470.8 Antenna Radiation Pattern Phi 0 2DPhi 90 2D Theta 90 2D 3D: Antenna Photo
Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 59 TEST REPORT Compiled by: Reviewed by: Approved by: Kai Chen Martin Feng Bin Mei / Director Note: If there is any objection to the inspection results in this report, please submit a written report to the company within 15 days from the date of receiving the report. The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. The tested sample(s) and the sample information are provided by the applicant. The authenticity, accuracy, and completeness of the provided information are the sole responsibility of the applicant. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report can’t be reproduced except in full. The result decision rules of our laboratory are based solely on the direct comparison between the actual measured values of test results and the standard limits, without considering the measurement uncertainty.“” indicates the testing items were fulfilled by subcontracted lab. “” indicates the items are not in CNAS accreditation scope. Test item description: Hyper Fusion Transmitter FCC ID: 2BVSR-V4RX Trademark(s): N/A Model/Type reference: V4RX Applicant’s name: HyperionSim LLC Address: 32268 Corte Sabrinas, Temecula, CA 92592, USA Manufacturer: HyperionSim LLC Address: 32268 Corte Sabrinas, Temecula, CA 92592, USA Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: 1&2/F., Building A, No.26, Xinhe Road, Xinqiao, Xinqiao Street, Bao'an District, Shenzhen, Guangdong, China Sample Received Date: Mar. 16, 2026 Sample tested Date: Mar. 16, 2026 to Apr. 28, 2026 Issue Date: Apr. 28, 2026 Report No.: CTB26031611404RF02 Test Standards FCC CFR Title 47 Part 15 Subpart E Section 15.407 Test Results PASS Remark: This is WIFI-5GHz band radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB26031611404RF02 Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 59 TABLE OF CONTENT Test Report Declaration Page 1. VERSION ....................................................................................................................... 4 2. TEST SUMMARY .......................................................................................................... 5 3. MEASUREMENT UNCERTAINTY .............................................................................. 6 4. PRODUCT INFORMATION AND TEST SETUP ....................................................... 7 4.1 Product Information ................................................................................................................. 7 4.2 Test Setup Configuration ....................................................................................................... 7 4.3 Support Equipment .................................................................................................................. 7 4.5 Test Mode .................................................................................................................................. 8 4.6 Test Environment ..................................................................................................................... 8 5. TEST FACILITY AND TEST INSTRUMENT USED .................................................. 9 5.1 Test Facility................................................................................................................................ 9 5.2 Test Instrument Used ............................................................................................................. 9 6. AC POWER LINE CONDUCTED EMISSION ......................................................... 12 6.1 Block Diagram Of Test Setup ............................................................................................. 12 6.2 Limit ........................................................................................................................................... 12 6.3 Test procedure ........................................................................................................................ 12 6.4 Test Result ............................................................................................................................... 14 7. RADIATED SPURIOUS EMISSIONS ...................................................................... 16 7.1 Block Diagram Of Test Setup ............................................................................................. 16 7.2 Limit ........................................................................................................................................... 16 7.3 Test procedure ........................................................................................................................ 17 7.4 Test Result ............................................................................................................................... 18 8. BAND EDGE ............................................................................................................... 21 8.1 Block Diagram Of Test Setup ............................................................................................. 21 8.2 Limit ........................................................................................................................................... 21 8.3 Test procedure ........................................................................................................................ 21 8.4 Test Result ............................................................................................................................... 22 9. CONDUCTED OUTPUT POWER ............................................................................ 24 9.1 Block Diagram Of Test Setup ............................................................................................. 24 9.2 Limit .............................................................................................................…
Text truncated - open the document above for the full version.
Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 1 of 2 Model: V4RX Radiated Emission Below 1G Above 1G Shenzhen CTB Testing Technology Co., Ltd. Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 2 Conducted emissions RF Conducted
19784 SUNKISSED RIDGE DR, RIVERSIDE, CA 92507 · RIVERSIDE, California, 92507 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15E | 5.75 GHz - 5.83 GHz | 53.14 mW |

Hyper Fusion Transmitter
Equipment Class
NII - Unlicensed National Information Infrastructure TX