FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Veritas Vans LLC/
  3. 2BVTF-VBAT5

2BVTF-VBAT5Veritas Battery

Veritas Vans LLC
Veritas Battery - FCC ID 2BVTF-VBAT5 - Veritas Vans LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 14, 2026
Application Purpose
Original Equipment
Equipment Note
Veritas Battery
Frequency Range
2402.00000000 - 2480.00000000
Company
Veritas Vans LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Veritas 5-Hour Veritas Vans Battery User Manual Veritas 5-Hour Battery | Model VBAT5 | By Veritas Vans Veritas Vans LLC · San Luis Obispo, CAPage 1 Veritas 5-Hour Battery Portable Power Bank | Product Manual | By Veritas Vans Product Na ItemContent BrandVeritas Vans meVeritas 5-Hour Battery ModelVBAT5 I. Product Introduction •Built-in foldable stand, compatible with Starlink Mini for convenient use while charging. •Bluetooth connectivity for real-time battery m onitoring and charge/discharge tracking on your phone. •Supports solar panel charging for continuous off-grid power, compatible with standard 12– •Compatible with laptops, drones, portable monitors, phones, and more—covers all your power needs. 36V panels. II. Important Safety Precautions 1.Do not disassemble, puncture, crush, or expose to fire to avoid risk of injury. 2.Do not use or store the product in extreme temperature environments. 3.Although the unit is IP67 waterproof and dustproof, do not expose it to corrosive liquids. 4.Only use original or certified charging cables, chargers, and solar panels. 5.During solar charging, keep the panel away from flammable materials. 6.This product contains small parts (e.g., cables). Keep away from children. 7.If the product emits an unusual odor, overheats, swells, leaks, or shows any other abnormality, stop using it immediately. Move it away from fire sources and contact Veritas Vans support. Do not attempt to repair it yourself. III. Product Specifications SpecificationDetail Battery Capacity27,500mAh / 99Wh Thank you for choosing this Veritas Vans portable power bank! With a large capacity (27, 500mAh / 99Wh), 100W fast charging,multiple interfaces, IP67 waterproof and dustproof rating, and solar panel charging, this product is designed for outdoor adventures, field work, business travel, and emergency backup power. Core Advantages Veritas 5-Hour Battery | Model VBAT5 | By Veritas Vans Veritas Vans LLC · San Luis Obispo, CAPage 2 DC Input 12 – 48V Solar Input 12–36V (supports MPPT fast charging) DC Output 15–21V (65W max) —voltage auto-negotiated USB-C (Bidirectional) Input / Output , PD Protocol Supported PD Voltages 5V/3A · 9V/3A · 12V/3A · 15V/5A · 20V/5A · 28V/5A Max USB-C Power 100W Approx . Charge Time ~1.5 hrs via 100W PD · ~2–3 hrs via DC · Varies by solar irradiance Operating Temperature 14°F to 104°F (-10°C to 40°C) Storage Temperature 32°F to 95°F (0°C to 35°C) Weight [INSERT WEIGHT] Dimensions (L×W×H) [241 x 161 x 26 mm] Special Features Bluetooth power monitoring , foldable stand Protection Rating IP67 —dustproof; protected against brief submersion up to 1m Manufactured In China for Veritas Vans LLC, San Luis Obispo, CA Compliance FCC ID: [INSERT] · CE: [INSERT] · RoHS Coliant n All [INSERT ...] placeholders must be completed before final publication. IV. User Guide Button Functions & LED Indicators 1.Short press: Wake / check display. 2.Long press 3 sec: Activate DC 5.5×2.1 output (15–21V, up to 65W). LED flashes green. Long press again 3 sec to deactivate. 3.Long press 15 sec: Reset the screen. LED StateMeaning Solid greenFully charged / standby Flashing greenDC output active LED Status Reference Veritas 5-Hour Battery | Model VBAT5 | By Veritas Vans Veritas Vans LLC · San Luis Obispo, CAPage 3 Solid blueCharging in progress Flashing blue Low battery ( ≤ 20%) Solid/flashing redFault — stop use, contact support n Confirm exact LED behavior with firmw are team before final publication. Port & Interface Reference •Display : •DC 5.5×2.1 Input (Front) : Accepts 12– •DC 5.5×2.1 Output (Rear) : Outputs 15–21V at up to 65W. Voltage auto-negotiated; no manual •USB-C Port : Bidirectional input/output, PD protocol , 100W max. selection required. 48V from chargers, adapters, or solar panels. Shows battery %, voltage, current, wattage, and charge/discharge time. •Mounting : M6 screws on top ; 1/4" screw on top (center) ; support bracket. (I) Charging the Power Bank MethodStepsEst. Time Recommended (PD Fast Charging) Use a PD-compatible charger (100W max) + USB-C cable →USB-C input port. ~1.5 hrs Alternative (DC Charging) Use a compatible DC power supply (12–48V) → DC input port. Varies byOutdoor ~2 - 3 hrs (Solar Charging) 2. Connect DC cable from panel output → 1. Use 12 - 36V MPPT-equipped solar panel. DC input port. 3. Aim panel at sun,unobstructed. Chargingstarts automatically .4. Monitor via Bluetooth on your phone. irradiance n Pass-Through: Simultaneous charge + discharge is supported (e.g. solar while powering a device). Total output may be reduced. Avoid sustained pass-through at maximum load to preserve battery longevity. 1.Make sure the power bank is actively charging or discharging. 2.Open Bluetooth on your phone, find the device named "Veritas Battery", and complete (II) Powering External Devices pairing. 1.Starlink Mini: Connect the DC output port (rear) to the device using a matching DC cable. 2.Laptops (High-Power Devices): Connect the USB-C port using a USB-C to USB-C cable (supports 100Wmax output). 3.Phones / Tablets / Other USB Devices: Connect the USB-C port using a USB-C cable. The fast charging protocol will be detected automatically. (III) Bluetooth Power Monitoring Veritas 5-Hour Battery | Model VBAT5 | By Veritas Vans Veritas Vans LLC · San Luis Obispo, CAPage 4 3.Once paired , check remaining battery percentage, voltage, current, and wattage in real time. 1.Unfold the stand and adjust the support angle. V. Maintenance 1. Before long-term storage (>1 month), charge to 50–70% and store in a dry, ventilated area (32–95°F /0–35°C). 2. Run one full charge-discharge cycle (full charge → drain below 20% → recharge) every 3 months to maintain battery health. 3. Clean the body and ports with a dry, soft cloth. Never use chemical cleaners or allow water into the ports. 4. When storing solar cables, avoid kinking or crushing them. Keep out of direct sunlight. Inspect cable jacket regularly. Replace if damaged. VI. Troubleshooting Unable to Power On / Charge 1.Verify…

Text truncated - open the document above for the full version.

Attestation Statements

VeritasVansLLC 249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates AttestationStatements NotCoveredEntityApplicant&NotCoveredEquipment To:FederalCommunicationsCommissionDate:May.13,26 7435OaklandMillsRoad, Columbia,MD21046,USA Ref:InformationRequiredbySection2.911(d)(5)(i)&(ii) FCCID:2BVTF-VBAT5 VeritasVansLLC(“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicantisnotidentifiedontheCoveredList,establishedpursuantto§1.50002ofreferencechapter, asanentityproducing“covered”communicationequipment.Theequipmentforwhichauthorizationis soughtisnot“covered”telecommunicationsequipmentandvideosurveillanceequipmentproducedby entitiesidentifiedontheCommission’sCoveredListthatprohibitedfromreceivinganequipment authorizationpursuanttosection§2.903oftheFCCrules. Sincerelyyours, ApplicantSignature PrintedName:CherryGao Title:Manager Address:249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates Tel.:8057624633 Email:[email protected]

Attestation Statements

VeritasVansLLC 249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates 1|Page AttestationStatements To:FederalCommunicationsCommissionDate:May.13,26 7435OaklandMillsRoad, Columbia,MD21046,USA Subject:AttestationofCompliancewithFCCCoveredListSoftwareRequirements FCCID:2BVTF-VBAT5 ProductName:VeritasBattery Thisletterservesasanattestationthattheequipmentidentifiedabove☐is/☒isnot(selectone)"covered" softwareasdefinedundertheFederalCommunicationsCommission(FCC)CoveredListrequirements,as outlinedinFCC22-84andKDB986446. Specifically,theundersignedcertifiesthattheequipmentforwhichauthorizationissought: 1.Doesnotcontaincybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab, Inc.oranyofitssuccessors,assignees,parents,subsidiaries,affiliates,oranyentitythathasrebranded orrelabeledsoftwareproducedbytheaforementionedentities. 2.Doesnothavethecapabilitytostore,run,ordeliveranysoftwareidentifiedontheFCCCoveredList, includingbutnotlimitedtocybersecurityandanti-virussoftware. Tosupportthisattestation,theappendixevaluationdocumentationhasbeenpreparedandisincludedinthe certificationfiling. Thisattestationisbasedonathoroughevaluationofthedevice'sdesign,functionality,andsoftware environment.Theundersignedaffirmsthattheinformationprovidedisaccurateandcompletetothebestof theirknowledge. Sincerelyyours, ApplicantSignature PrintedName:CherryGao Title:Manager Address:249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates Tel.:8057624633 Email:[email protected] VeritasVansLLC 249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates 2|Page EvaluationregardingtotheCoveredListSoftware: Compliance Methodology EvaluationProcessResults Deviceis Inherent compliance ☒ TheChipset(s)usedislimitedtorun theCybersecurityoranti-virus software. Compliance ☒ TheMemoryusedislimitedtorunthe Cybersecurityoranti-virussoftware. Compliance ☒ Thereisstoragecapacitylimitationfor storeorinstalltheCybersecurityor anti-virussoftware. Compliance ☒ Operatingsystemusedislimitedto run,installordelivertheCybersecurity oranti-virussoftware. Compliance Deviceisnot Inherent compliance ☐ EvaluationBasedonSoftware BillofMaterials(SBoM) ☐ EvaluationBasedonScanfor Softwareonthedevice ☐ EvaluationBasedonFilesystemscan ☐ EvaluationBasedonRunning softwarecheck

Attestation Statements

VeritasVansLLC 249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates U.S.AgentLetterofAttestation To:FederalCommunicationsCommission 7435OaklandMillsRoad,Columbia,MD21046,USA Date:May.9,26 Ref:AttestationStatement–Part2.911(d)(7)filing FCCID:2BVTF-VBAT5 VeritasVansLLC(“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,[LOBOS IOWAINC](“theagent”)isourdesignatedU.S.agentforserviceofprocessfortheabovereference FCCID.TheapplicantacceptstomaintainanagentforserviceofprocessintheUnitedStatesfor nolessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketingand importationoftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission- relatedadministrativeorjudicialproceedinginvolvingtheequipment,whicheverislater.The applicantfurtheracknowledgesitisourresponsibilitytoinformtheFCCwhenevertheagent informationchanges. [LOBOSIOWAINC]("theagent)understanditistheagent'sobligationtoacceptserviceofprocess intheUnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S. addressandemailaddress. DesignatedU.S.Agent CompanyName:LOBOSIOWAINC FRN:0036413961 Address:4623BittercreekDrColoradoSpringsco 80922Us Signature: ContactPerson:HarleyLi Tel:(818)818-0538Email:[email protected] Applicant CompanyName:VeritasVansLLC FRN:0038335352 Address:249TankFarmRoad,SanLuisObispo, California,Zipcode:93401,UnitedStates Signature: ContactPerson:CherryGao Tel:8057624633Email:[email protected]

Cover Letter(s)

VeritasVansLLC 249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates May.13,26 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:ConfidentialityRequestfor:FCCID:2BVTF-VBAT5 PursuanttoSections0.457and0.459oftheCommission’sRules,weherebyrequestpermanent confidentialtreatmentoftheexhibitsaccompanyingthiscertificationapplicationasoutlinedbelow:  BlockDiagram Schematics  OperationalDescription Theaboveexhibitscontaintradesecretsand/orproprietaryinformationthatarenotpubliclyavailableand materialsthattheApplicanthasspentconsiderableeffortsindeveloping.Publicdisclosureofthesemay beharmfultotheApplicantandgiveanunfairadvantagetocompetitorsonthemarket. PursuanttoDA04-1705,theapplicantalsorequeststemporaryconfidentialtreatmentoftheexhibits outlinedbelowforaperiodof()daysfromthedateofequipmentauthorizationandpriortomarketingin theUnitedStatestopreventtheprematurereleaseofanysensitiveinformation.Applicantisawareof theirresponsibilitytonotifyDERYCOMintheeventinformationregardingtheproductortheproductis madeavailabletothepublicbeforetherequestedperiodhasexpired. Sincerely, (Signature) PrintedName:CherryGao Title:Manager Address:249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates Tel.:8057624633 Email:[email protected]

Cover Letter(s)

VeritasVansLLC 249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates May.13,26 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Subject:AgentAuthorizationforFCCID:2BVTF-VBAT5 I,theundersigned,herebyauthorize(FluxComplianceServiceLaboratory)toactonourbehalfinall mattersrelatingtothisapplicationforequipmentcertification. Anyactcarriedoutby(FluxComplianceServiceLaboratory)shallhavethesameeffectasourown andIacknowledgethatallresponsibilityforcomplyingwiththetermsandconditionsofcertification,as specifiedbyDERYCOMCERTIFICATIONSERVICES,INC.,stillresideswith(VeritasVansLLC). WecertifythatwearenotsubjecttoadenialoffederalbenefitsthatincludesFCCbenefitspursuantto Section5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862,andthatnopartytotheapplication,as definedin47CFR§1.2002(b),issubjecttoadenialoffederalbenefitsthatincludesFCCbenefits pursuanttothatsection. Sincerely, (Signature) PrintedName:CherryGao Title:Manager Address:249TankFarmRoad,SanLuisObispo,California,Zipcode:93401,UnitedStates Tel.:8057624633 Fax:8057624633 Email:[email protected]

Cover Letter(s)

VeritasVansLLC ProductSimilarityDeclaration EUTDescription:VeritasBattery ModelNo.:5-Hour SeriesModel:4-Hour,6-Hour,7-Hour,8-Hou,44-Hour,45-Hour, 46-Hour,47-Hour,48-Hour We(VeritasVansLLC)herebystatethatallthemodelsare electricalidenticalincludingthesamesoftwareparameterand hardwaredesign(i.e.,circuitdesign,PCBLayout,RF module/circuit,antennatype(s)andantennalocation,components onPCB,etc.,),samemechanicalstructureanddesign(including productenclosure,materials,etc.,),theonlydifferenceisthe modelnameandcolour. Signature: Name:CherryGao Title:Manager Place,date:Apr.28,2026

External Photos

Page1of4ReportNo.:FCS202603241 Externalphotos Photo1 Photo2 Page2of4ReportNo.:FCS202603241 Photo3 Photo4 Page3of4ReportNo.:FCS202603241 Photo5 Photo6

ID Label/Location Info

LabelandLabelLocation FCCID:2BVTF-VBAT5 L*W:10mm*5mm labelandWhitefont

Internal Photos

Page1of2ReportNo.:FCS202603241 Internalphotos Photo1 Photo2 Page2of2ReportNo.:FCS202603241 Photo3 Photo4 Page3of2ReportNo.:FCS202603241 Photo5 Photo6

RF Exposure Info

FCS202603241H01 FCCRFExposure EUTDescription:VeritasBattery ModelNo.:5-Hour FCCID:2BVTF-VBAT5 Equipmenttype:portabledevice AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093,Unlessspecifically requiredbythepublishedRFexposureKDBprocedures,standalone1-gheadorbodyand10-g extremitySARevaluationforgeneralpopulationexposureconditions,bymeasurement ornumenicasimulation,isnotrequiredwhenthecorrespondingSARTest ExclusionThresholocondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances<50mm,the1-gand10-gSARtestexclusion thresholdsaredeterminedbythefollowing: f(GHz)istheRFcharneltransmitfrequencyinGHzTheresultisroundedtoonedecimalplacefor comparison [(max.powerofchannel,includingtune-upfolerance,mW)/(mintestseparation distancemm)](viGHz)]<3.0for1-gSAR,ands7.5for10-gextremitySAR,where PoweranddistanceareroundedtothenearestmWandmmbeforecalculation LimitsforMaximumPermissibleExposure(MPE) Frequency(MHz) conducted output power (dBm) MaxTurn upPower (dBm) M axTurnup Power (mW) Antenna Gain(dBi) Min. distance( mm) Result limit 24022.953+/-0.52.242.05 0.694 3 24401.391+/-0.51.412.05 0.438 3 24803.883.5+/-0.52.512.050.779 3 Conclusion:NoSARisrequired

Test Report

ConfirmationLetterProjectTable NO. Contents Number ofPage Page Code 1 SpecCover 11 2 SpecItem 12 3 Drawing 1 3 4 TestReports 14 5 SParameter 1 5 6 GainTest 1 6 7 8 9 10 --- 11 --- 12 --- Tel:0769-33691210Fax:0769-82381572 SIGNDATEDESCRIPTIONAPPROVER B D Note: 1.Take"*"istheimportantdimension. 2.Tolerance:Unmarkedtolerancereferto thestandardtoleranceplease. 3FW2509FPCBFPCB25*09mm1 2 R-CB-113BCableO.D.1.13mmBlack1 1CI-113 Connector MiniConnector1 No.PartNumberNameMaterial Q'ty TITLE:ANTENNA PARTNO.:FW2509-113B-IX060 APPROVEDBYCHECKEDBY jeffleon 2022-01-102022-01-10 DESIDNEDBY YD 2022-01-10 UNITS:mm SCALE:1/1 REVISION:A DWGNAME:FW2509-113B-IX060.DWG X.X±0.20 X.XX±0.10 X°±3° Tolerance C Tel:0769-33691210Fax:0769-82381572 TestReports SamplePhoto A.ElectricalCharacteristics Frequency 2400~2500MHz4900~5900MHz S.W.R. <=2.5 AntennaGain 2.0±0.7dBi Impedance 500hmNominal ReturnLoss-10dBMax Radiation Omni-directional CableLoss4.9dB/mMax@5000MHz PolarizationLinear,Vertical AdmittedPower1W Connector 13 PhysicalProperties AntennaMaterialFPCB CableType O.D.1.13mm//060mm OperatingTemp. -35~+60 ̊C StorageTemp. -35~+70 ̊C Tel:0769-33691210Fax:0769-82381572 SParameterTest AgilentE5071C ProductName:Antenna 5.Antenna-RadiationPatternTestData XY-PLANE 2400MHz2450MHz2500MHz 5000MHz5500MHz5800MHz ProductName:Antenna 5.Antenna-RadiationPatternTestData XZ-PLANE 2400MHz2450MHz2500MHz 5000MHz5500MHz5800MHz ProductName:Antenna 5.Antenna-RadiationPatternTestData YZ-PLANE 2400MHz2450MHz2500MHz 5000MHz5500MHz5800MHz

Test Report

FCCTestReport ReportNo:FCS202603241W01 Issuedfor Applicant: VeritasVansLLC Address: 249TankFarmRoad,SanLuisObispo,California,Zipcode: 93401,UnitedStates ProductName: VeritasBattery BrandName: ModelName: 5-Hour SeriesModel: 4-Hour,6-Hour,7-Hour,8-Hou,44-Hour,45-Hour,46-Hour,47-Hour, 48-Hour FCCID: 2BVTF-VBAT5 IssuedBy:FluxComplianceServiceLaboratory Add:Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial, SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com Page 2 of42ReportNo.:FCS202603241W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com TESTRESULTCERTIFICATION Applicant’sName......................:VeritasVansLLC Address......................................: 249TankFarmRoad,SanLuisObispo,California,Zipcode: 93401,UnitedStates Manufacture'sName ................ :ShenzhenXinChangjiangElectronicTechnologyCo.,Ltd. Address......................................: 4thFloor,BuildingD,GongheZhaochangIndustrialPark,Shajing Street,Bao'anDistrict,ShenzhenCity ProductDescription ProductName...........................:VeritasBattery BrandName...............................: ModelName..............................:5-Hour SeriesModel..............................: 4-Hour,6-Hour,7-Hour,8-Hou,44-Hour,45-Hour,46-Hour, 47-Hour,48-Hour TestStandards .......................... :FCCRulesandRegulationsPart15SubpartC,Section247 TestProcedure..........................:ANSIC63.10-2020+Cor.1-2023 ThisdevicedescribedabovehasbeentestedbyFluxComplianceServiceLaboratory,thetestresults showthattheequipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditis applicableonlytothetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofFluxCompliance ServiceLaboratory,thisdocumentmaybealteredorrevisedbyFluxComplianceServiceLaboratory, personalonly,andshallbenotedintherevisionofthedocument.. DateofTest..................................: Date(s)ofperformanceoftests.:Mar20,2026~Mar25,2026 DateofIssue.................................:Mar25,2026 TestResult ..................................... :Pass Testedby: (JojoWu) Reviewedby : (JojoWu) Approvedby: ( JackWang ) Page 3 of42ReportNo.:FCS202603241W01 FluxComplianceServiceLaboratory Room105FloorBaohaoTechnologyBuilding1NO.15GongyeWestRoadHi-TechIndustrial,SongshanlakeDongguan Tel:0769-27280901Fax:0769-27280901http://www.FCS-lab.com TableofContentsPage 1.SUMMARYOFTESTRESULTS..............................................................................................6 1.1TESTFACTORY................................................................................................................7 1.2MEASUREMENTUNCERTAINTY.....................................................................................7 2.GENERALINFORMATION.......................................................................................................8 2.1GENERALDESCRIPTIONOFTHEEUT..........................................................................8 2.2BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED.............10 2.3DESCRIPTIONOFNECESSARYACCESSORIESANDSUPPORTUNITS.................11 2.4EQUIPMENTSLIST.........................................................................................................12 3.6DBBANDWIDTH..................................................................................................................13 3.1Limit..................................................................................................................................13 3.2TestProcedure.................................................................................................................13 3.3Testsetup.........................................................................................................................13 3.4Testresults.......................................................................................................................14 3.5OriginalTestData.............................................................................................................15 4.CONDUCTEDOUTPUTPOWER...........................................................................................18 4.1LIMIT................................................................................................................................18 4.2TESTPROCEDURE........................................................................................................18 4.3TESTSETUP...................................................................................................................18 4.4TESTRESULTS...............................................................................................................18 5.BANDEDGEANDSPURIOUS(CONDUCTED)....................................................................19 5.1LIMIT................................................................................................................................19 5.2TESTPROCEDURE........................................................................................................19 5.3TESTSETUP...................................................................................................................19 5.4TESTRESULTS...............................................................................................................20 6.POWERSPECTRALDENSITY..............................................................................................24 6.1LIMIT................................................................................................................................24 6.2TESTPROCEDURE........................................................................................................24 6.3TESTSETUP...................................................................................................................24 6.4TESTRESULTS...................…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of2ReportNo.:FCS202603241 RE(Above1GHz) RE(Below1GHz) Page 2 of2ReportNo.:FCS202603241 CE

Contact Information

Applicant

Cherry Gao
[email protected]Fax: 805 762 4633

Technical Contact

LOBOS IOWA INCHarley Li
[email protected]

4623 Bittercreek Dr · Colorado Springs, Colorado, 80922 · United States

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.40 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.