FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Dongguan Heshunkang Intelligent Technology Co., Ltd/
  3. 2BVUE-S11

2BVUE-S11Bluetooth smart watch

Dongguan Heshunkang Intelligent Technology Co., Ltd
Bluetooth smart watch - FCC ID 2BVUE-S11 - Dongguan Heshunkang Intelligent Technology Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 21, 2026
Application Purpose
Original Equipment
Equipment Note
Bluetooth smart watch
Frequency Range
2402.00000000 - 2480.00000000
Company
Dongguan Heshunkang Intelligent Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

EN Swipe Right Swipe down in the main interface to view control interface, click LIGHT Mobile phone system requirements: Android 5.0 and aboveIOS 11.0 or above One end of the charging cable is connected to the charging adapter via USB, and the other end is attached to the contact point on the back of the watch. The watch screen will display the charging indication, and the charging will start. Note: Connect USB interface to charger with output current of 1A or above or USB interface of computer for charging to turn on/off the Smart Watch User Guide 1 Touch And Key Operation Instructions 2 Watch Charging Use your mobile phone to scan the QR code below, download and install the APP, or use an Android phone to go directly to App Store, or use an Apple phone to go directly to the Apple Store, and search for "FitCloudPro" to download and install. 3 Download Installation APP 1. Scan code connection: open the "Device" column under the "FitCloudPro" APP in the mobile phone, click to add the binding device on the top right of the device, and the QR code in the scan watch is paired and bound 2. Manual connection: After the mobile phone turns on wireless, enter the "Device" column under the "FitCloudPro" APP, click Add Device, and directly search for the device for manual connection 4 Connect the Watch Swipe Down ----On/Off Key (Rotary Button) Swipe Left ---Mode Key Swipe UP Screen Operation Flashlight Introduction Swipe Up 1.SMS Notification Swipe Down 1. Control Interface Swipe Left 1. Function Interface Swipe Right 1. Quick Sidebar 英语:English Matters needing attention Smart watch supports:Answer/make calls, message notifications, breathing training, weather, sports mode, remote photography, music control, etc. 5 Functions on Smart Watch 1. wireless data transmission:When connected to the mobile phone, the watch will instantly synchronize data with the mobile phone through wireless, such as weather, notification messages, sports and health data, etc. These data will not be synchronized after disconnecting or turning off wireless 2 .Watch faces:Over 100 watch faces for choosing, you could download and custom watch face on FitCloudPro App 3.Notifications:Turn on the switch to sync related information to smartwatch(Phone, Messages, Facebook, X, WhatsApp, WeChat, Instagram, Skype, KakaoTalk,Line, Others) 6 FitCloudPro APP Function Before pairing, ensure that the power of the watch is above 20% to avoid pairing due to insufficient power · During the pairing connection, ensure that the wireless of the mobile phone is turned on, the call audio of the watch, and the media audio open · To turn off call audio, media audio, click the phone icon to turn it on and off · Do not disassemble, repair or modify the product without authorization · Common problem handling For more frequently asked questions, please check the mobile app [My>FAQ] The watch cannot be switched on Please fix the power key for more than 3 seconds · wireless is not connected or cannot be connected Please try to restart the watch and reconnect · Inaccurate measuremen It is generally caused by poor contact between the sensor of the watch and the human body during measurement FCC WARNING This device complies with part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) this device may notcause harmful interference, and (2) this device must accept anyinterference received,including interference that may causeundesired operation. Any changes or modifcations not expressly approved by the partyresponsible for compliance could void the user's authority tooperate the equipment. NOTE: This equipment has beentested and found to comply withthe limits for a Class B digita l device, pursuant to Part 15 of the FCCRules. These limits are designed to provide reasonabl e protectionagainst harmful interference in a residential installation. Thisequipment generates , uses and can radiate radiofrequency energyand, if not installed and used in accordance wit h the instructions,may causeharmfulinterference to radio communications.However, there is no quarantee that interference will not occur inaparticular installation. if this equipment does cause harmfulinterference to radio or television reception,which can bedetermined by turnin g the equipment of and on, the user isencouraged to try to correct the interference by one or more of thefollowing measures: - Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver.Connect the equipment into a n outlet on a circuit differentfromthat to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposurerequirement. The devicecan be used in portable exposurecondition without restriction. · Please pay attention to the full contact between the sensor and wrist when measuring · Keep your body still and watch close to your wrist during measurement · For people with darker skin color and more hair on their arms, please enable enhanced measurement in App [Equipment>Enhanced Measurement] · Please try to restart the mobile phone wireless and connect again · The mobile phone should not be connected to other wireless devices at the same time · The battery may be too low, please charge it in time · Do not collide the product violently to avoid product damage · Please avoid using in strong magnetic field, direct light or high temperature environment · This product is not used for disease diagnosis, treatment and prevention · If the watch is not connected to the mobile phone APP for a long time or the power is cut off for a long time, the time will be inaccurate, APP synchronization required · 英语:English DE Nach rechts wischen Wischen Sie in der Hauptschnittstelle nach unten, um die Steueroberfläche anzuzeigen, klicken Sie auf, um das Licht ein- und auszuschalten Mobile phone system requirements: Android 5.0 and aboveIOS 11.0 or above Ein Ende des Ladekabels wird über…

Text truncated - open the document above for the full version.

Attestation Statements

DongguanHeshunkangIntelligentTechnologyCo.,Ltd CoveredEquipmentCertificationAttestationLetter 7/15/2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa K1V1H2 Canada ATTN.:ReviewingEngineer FCCID:2BVUE-S11 DongguanHeshunkangIntelligentTechnologyCo.,Ltd(“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtisnot“covered”equipmentprohibitedfrom receivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. Note:Iftheequipmentforwhichtheapplicantseeksauthorizationisproducedby anyoftheentitiesidentifiedonthecurrentCoveredList,theapplicantshould includeanexplanationonwhytheequipmentisnot“covered”equipment. DongguanHeshunkangIntelligentTechnologyCo.,Ltd(“theapplicant”)certifiesthat,as ofthedateofthefilingoftheapplication,theapplicantisnotidentifiedontheCovered Listasanentityproducing“covered”equipment. DongguanHeshunkangIntelligentTechnologyCo.,Ltd(“theapplicant”)certifiesthatthe equipmentforwhichauthorizationissoughtdoesnotincludecybersecurityoranti-virus softwareproducedorprovidedbyKasperskyLab,Inc.oranyofitssuccessorsand assignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886 andKDB986446D01CoveredEquipmentGuidancesectionB(2a). Signed: Printedname:Zhuhuawen Title:Manager CompanyName:DongguanHeshunkangIntelligentTechnologyCo.,Ltd Date:7/15/2026

Cover Letter(s)

DongguanHeshunkangIntelligentTechnologyCo.,Ltd 7/15/2026 NemkoNorthAmerica,Inc. 303RiverRoad Ottawa,Ontario,Canada K1V1H2 REQUESTFORCONFIDENTIALITY-FCC FCCID:2BVUE-S11 PursuanttoSections0.457(d)(1)(ii)and0.459oftheCommission’sRulesandFCCGuidance document726920,weherebyrequestconfidentialtreatmentofinformationaccompanyingthis applicationasoutlinedbelow: PERMANENTLONG-TERMCONFIDENTIALITY: Schematics BlockDiagrams TheoryofOperation Theaboveinformationcontainstradesecretsandproprietaryinformationnotcustomarilyreleasedto thepublic.Thepublicdisclosureofthisinformationmightbeharmfultotheapplicantandprovide unjustifiedbenefitstoitscompetitors.TheApplicantunderstandsthatpursuanttoRule0.457(d)(1)(ii), disclosureofthisApplicationandallaccompanyingmaterialswillnotbemadebeforethedateofthe GrantforthisApplication. Sincerely, Signed: Printedname:Zhuhuawen Title:Manager

External Photos

FCCID:2BVUE-S11 FCCID:2BVUE-S11 FCCID:2BVUE-S11 FCCID:2BVUE-S11

ID Label/Location Info

S m a r t W a t c h M o d e l : S 1 1 F C C I D : 2 B V U E - S 1 1

Internal Photos

FCCID:2BVUE-S11 FCCID:2BVUE-S11 FCCID:2BVUE-S11

RF Exposure Info

Page1of2 RFEXPOSUREEVALUATION FCCID:2BVUE-S11 ProductName:Bluetoothsmartwatch ModelName:S11 BluetoothVersion:BTBDR+EDR Operatingfrequency:2402-2480MHz NumbersofChannel: 79channelsforBDR+EDR 40channelsForDTS AntennaType:Internalantenna AntennaGain:-4.04dBi TypeofModulation: GFSK,Π/4-DQPSK,8DPSKForDSS GFSK,ForDTS Powersupply: Input:DC5V⎓120mA Batterymodel:552124,3.8V,280mAh,1.064w HardwareVersion:N/A SoftwareVersion:N/A Page2of2 StandardRequirement Accordingto§15.247(i)and§1.1307b(1),systemsoperatingundertheprovisionsofthis sectionshallbeoperatedinamannerthatensuresthatthepublicisnotexposedtoradio frequencyenergylevelsinexcessoftheCommission’sguidelines.SeeKDB447498D01 GeneralRFExposureGuidancev06,section4.3.1. The1-gand10-gSARtestexclusionthresholdsfor100MHzto6GHzattestseparation distances≤50mmaredeterminedby: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparationdistance, mm)]*[√f(GHz)]≤3.0for1-gSARand≤7.5for10-gSARextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculation Theresultisroundedtoonedecimalplaceforcomparison. Thetestexclusionsareapplicableonlywhentheminimumtestseparationdistanceis≤ 50mmandfortransmissionfrequenciesbetween100MHzand6GHz.Whentheminimumtest separationdistanceis<5mm,adistanceof5mmisappliedtodetermineSARtestexclusion. RoutineSARevaluationreferstothatspecificallyrequiredby§2.1093,usingmeasurements orcomputersimulation.WhenroutineSARevaluationisnotrequired,portabletransmitters withoutputpowergreaterthantheapplicablelowthresholdrequireSARevaluationtoquality forTCBapproval. Channel (MHz) Maximum output power (dBm) Tuneup tolerance (dBm) MaxTune UpPower (mW) Distance (mm) Calculation results Limit Operating Mode 2480 3.463.46±1 2.79254450.87954033DH5 AccordingtoKDB447498,ThedeviceonlysupportBTfunction,andnosimultaneousSAR measurementisrequired. Signature SimonPu Manager Date:2026-06-08

Test Report

Address: Rooms 1516-1517, 15th Floor, Hung Kai Capital Building, 8 On Ping Street, Shek Mun, San Tin, Hong K Forbet International (Hong Kong) Limited ong Notesforantennainstallation Length Notesforantennainstallation Electronicwireinstallationrecommendations: 1:Theelectronlinelengthisinthe24.60mm. 2:Theelectronicwireisinstalledonthesideofthehorn. 3:Theendoftheelectronicwireisfixedwithadhesive papertomaketheconsistencyofthebatchproductiongood. Antennaparameters Freq 2.4GHz2.5GHz spce VSWR 1.481.79 <2 LogMag -14.15-10.93 <-10 Antennaparameters Frequency/MhzEfficiency/% Gain/dBi 24004.2-4.1 24104.21-5.07 24204.33 -4.05 24304.38 -4.04 24404.4 -4.3 24504.66 -5.29 24604.8 -5.2 24705.01 -4.14 24804.7 -4.25 24904.65 -5.26 25004.29 -5.3

Test Report

Page1of59 FCCTESTREPORT FCCID:2BVUE-S11 Product: Bluetoothsmartwatch ModelName: S11 Brand: N/A ReportNo.: PTC26041720601E-FC01 Preparedfor DongguanHeshunkangIntelligentTechnologyCo.,Ltd. Room302,Building1,No.23,GuestRoad,HuangjiangTown,DongguanCity,Guangdong Province,China Preparedby PreciseTesting&CertificationCo.,Ltd Building1,No.6,TongxinRoad,DongchengStreet,Dongguan,Guangdong,China ReportNo.:PTC26041720601E-FC01 Page2of59 1TESTRESULTCERTIFICATION Applicant’sname: DongguanHeshunkangIntelligentTechnologyCo.,Ltd. Address: Room302,Building1,No.23,GuestRoad,HuangjiangTown,Dongguan City,GuangdongProvince,China Manufacture'sname: DongguanGenaiTechnologyCo.,Ltd. Address: Room901,No.2Building,No.1,JiaopingRoad,TangxiaTown,Dongguan City,GuangdongProvince,China Productname: Bluetoothsmartwatch Modelname: S11 Standards:FCCCFR47Part15Section15.247 Testprocedure:ANSIC63.10-2020 TestDate: May.08,2026toJun.08,2026 DateofIssue: Jun.08,2026 TestResult:Pass ThisdevicedescribedabovehasbeentestedbyPTC,andthetestresultsshowthatthe equipmentundertest(EUT)isincompliancewiththeFCCrequirements.Anditisapplicableonlyto thetestedsampleidentifiedinthereport. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofPTC,thisdocument maybealteredorrevisedbyPTC,personalonly,andshallbenotedintherevisionofthedocument. TestEngineer: Jackzhou/Engineer TechnicalManager: SimonPu/Manager ReportNo.:PTC26041720601E-FC01 Page3of59 Contents Page 1TESTRESULTCERTIFICATION...............................................................................................................................2 2TESTSUMMARY..........................................................................................................................................................5 2.1TESTSITE............................................................................................................................................................6 3GENERALINFORMATION.......................................................................................................................................7 3.1GENERALDESCRIPTIONOFE.U.T.....................................................................................................................7 3.2CHANNELLIST.....................................................................................................................................................8 4EQUIPMENTDURINGTEST....................................................................................................................................9 4.1EQUIPMENTSLIST.............................................................................................................................................9 4.2MEASUREMENTUNCERTAINTY.........................................................................................................................11 4.3DESCRIPTIONOFSUPPORTUNITS...................................................................................................................12 5CONDUCTEDEMISSION..........................................................................................................................................13 5.1E.U.T.OPERATION............................................................................................................................................13 5.2EUTSETUP.......................................................................................................................................................13 5.3TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION).................................................................................14 5.4MEASUREMENTPROCEDURE............................................................................................................................14 5.5CONDUCTEDEMISSIONLIMIT...........................................................................................................................14 5.6MEASUREMENTDESCRIPTION..........................................................................................................................14 5.7CONDUCTEDEMISSIONTESTRESULT.............................................................................................................14 6RADIATEDSPURIOUSEMISSIONS......................................................................................................................17 6.1EUTOPERATION...............................................................................................................................................17 6.2TESTSETUP......................................................................................................................................................18 6.3SPECTRUMANALYZERSETUP..........................................................................................................................19 6.4TESTPROCEDURE.............................................................................................................................................20 6.5SUMMARYOFTESTRESULTS...........................................................................................................................22 7CONDUCTBANDEDGEANDSPURIOUSEMISSIONSMEASUREMENT....................................................30 7.1TESTPROCEDURE.............................................................................................................................................30 7.2TESTSETUP......................................................................................................................................................31 7.3TESTRESULT....................................................................................................................................................32 ReportNo.:PTC26041720601E-FC01 Page4of59 86DBBANDWIDTHMEASUREMENT......................................................................................................................38 TESTPROCEDURE..................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2BVUE-S11 ConductedEmissions RadiatedSpuriousEmissions From30MHz-1000MHz FCCID:2BVUE-S11 TestfrequencyfromAbove1GHz

Contact Information

Applicant

Zhu huawen
[email protected]Fax: 13430566138

Technical Contact

MIRAMONT SOLUTIONS LLCWenyi Wang
[email protected]

19 GEORGETOWN, IRVINE · IRVINE, 92612 · United States

Test Firm

Precise Testing & Certification Co., LTD.Yang Juan
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.59 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.