FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Safety Electronic Technology (Huizhou) Co., Ltd/
  3. 2BVVZ-CLZ-3373-C

2BVVZ-CLZ-3373-CCentralite Water Leak Sensor

Safety Electronic Technology (Huizhou) Co., Ltd
Centralite Water Leak Sensor - FCC ID 2BVVZ-CLZ-3373-C - Safety Electronic Technology (Huizhou) Co., Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 30, 2026
Application Purpose
Original Equipment
Equipment Note
Centralite Water Leak Sensor
Frequency Range
2405.00000000 - 2480.00000000
Company
Safety Electronic Technology (Huizhou) Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

• Press and hold the reset button for 5 seconds, until the network indicator light begins flashing. Follow the A pp instructions to add the device. • Once the device has been successfully added, you will be able to find the device in the "My home" list. Product description This Water Leak Sensor adops Zigbee wireless technology is used for detecting leaked water and flooded water indoor, and works in conjunction with other devices to design and implement smart application scenarios. Place the product in a locaiton wherer likely to occur water leaking. Probe Product specifications Product name Water Leakage Sensor Model number Battery specifications CLZ-3373-C 2*AAA battery Operating temperature -10 ° (- 50 ° ( Operating humidity 10%-90%RH (no condensation) Wireless connection ZigBee Preparation for use G) Ensure that the product is within the effective coverage of the smart host (gateway) ZigBee network to ensure an effective connection between the product and the smart host (gateway) ZigBee network. *Make sure the smart host has been added. Items not under warranty 1. Unauthorized repairs, misuse, collisions, negligence, abuse, exposure of the product to moisture or water, accidents, alterations, improper use of accessories, tearing or al teration of stickers or anti-counterfeiting marks; 2. The validity period of the warranty has passed. 3. Damage caused by force majeure; 4. Damage or malfunction caused by problems other than the design, technology, manufacturing, quality of the product. Preparation for use @ Download and open the App In the App Store, search for "Smart Life" or scan the QR code on the package/manual to download and install the smart App. If you are downloading this App for the first time, please tap the "Register''button to register your account; If you already have an account, click the "Login" button. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. -This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Attestation Statements

1/1 USAgentforServiceofProcessLETTEROFATTESTATION TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USAgentforServiceofProcess: CompanyName:HerlandInternationalTradingInc FRN:36324101 ContactName:JianfengGao Address:1370ValleyVistaDrSte200DiamondBarCalifornia91765-3921 TelephoneNo:001-909-772-1888 Email:[email protected] Applicant: Companyname:SafetyElectronicTechnology(Huizhou)Co.,Ltd. ProductDescription:CentraliteWaterLeakSensor Granteecode:2BVVZ FCCID:2BVVZ-CLZ-3373-C FRN:0038354429 ContactName:Jackbu Address:A1004,JieshunTechnologyCenter,No.5Guansheng2ndRoad,LuhuCommunity, GuanhuStreet,LonghuaDistrict,Shenzhen,China. TelephoneNo:18906679427 Email:[email protected] [SafetyElectronicTechnology(Huizhou)Co.,Ltd.]certifiesthat,asofthedate ofthisfilingoftheapplicationwiththeTCB,[HerlandInternationalTradingInc] isourdesignatedUSagentforserviceofprocessfortheabovereferencedFCC ID.[SafetyElectronicTechnology(Huizhou)Co.,Ltd.]acceptstomaintainan agentfornolessthanoneyearafterthegranteehasterminatedallmarketing andimportationortheconclusionofanycommissionrelatedproceeding involvingequipment.[HerlandInternationalTradingInc]accepts,asofthedate ofthefilingoftheapplication,theobligationofthedesignatedUSagentfor serviceofprocessfortheabovereferenceFCCID. TheUSAgentforServiceofProcessisawareofandagreestocomplywiththerequirements outlinedintheFCCEquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause §2.911. TheApplicantisawareofandagreestocomplywiththerequirementsoutlinedintheFCC EquipmentAuthorizationProgram,ReportandOrderFCC22-84,andclause§2.911. Date:2026/4/29 Applicant’sName:JackbuUSAgent’sName:JianfengGao Title:ManagerTitle:Manager SignatureSignature

Attestation Statements

AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1 SafetyElectronicTechnology(Huizhou)Co.,Ltd. TO: OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 TheCommissionadoptedrulesthatprohibitequipmentauthorizationfor“covered” telecommunicationsequipmentandvideosurveillanceequipmentproducedbyentitiesidentified ontheCommission’sCoveredList 1 ,whichisperiodicallyupdated.SeetheCoveredListformore details.ThisAttestationStatementistoconfirmthatwefollowtheSection2.911(d)(5)(i)-(ii) Applicant Companyname:SafetyElectronicTechnology(Huizhou)Co.,Ltd. Granteecode:2BVVZ FCCID:2BVVZ-CLZ-3373-C FRN:0038354429 ContactName:Jackbu Address:A1004,JieshunTechnologyCenter,No.5Guansheng2ndRoad,Luhu Community,GuanhuStreet,LonghuaDistrict,Shenzhen,China. TelephoneNo:18906679427 FaxNo:18906679427 Email:[email protected] i.[SafetyElectronicTechnology(Huizhou)Co.,Ltd.](“theapplicant”)certifies thattheequipmentforwhichauthorizationissoughtisnot“covered” equipmentprohibitedfromreceivinganequipmentauthorizationpursuantto section2.903oftheFCCrules.Theapplicantmustsignthiscertification. ii.[SafetyElectronicTechnology(Huizhou)Co.,Ltd.](“theapplicant”)certifies that,asofthedateofthefilingoftheapplication,theapplicant[isnot](asa specificallynamedentityoranyofitssubsidiariesoraffiliates)identifiedon theCoveredListasanentityproducing“covered”equipment.Theapplicant mustsignthiscertification. [SafetyElectronicTechnology(Huizhou)Co.,Ltd.](“theapplicant”)certifiesthat,as ofthedateofthefilingoftheapplication,theapplicant[isnot]identifiedonthe CoveredListasanentityproducing“covered”equipment. Date:2026/4/29 Applicant’sName:Jackbu Title:Manager Signature: 1 TheCommission’sCoveredListispublishedbythePublicSafetyandHomelandSecurityBureauandpostedonthe Commission’swebsite.ThisCoveredList,whichisperiodicallyupdated,identifiesparticularequipment,producedby particularentities,thatconstitutes“covered”equipment.https://www.fcc.gov/supplychain/coveredlist AttestationStatement. OldCode:C526609124NewCode:00015544Ed.3 Changereason:FRNisaddedtotheApplicantinformationsection. 1/1

Attestation Statements

SafetyElectronicTechnology(Huizhou)Co.,Ltd. Code00018768Ed.1 Item1.Thedeviceisabletoinstallsoftware/programinstallation? ☐ Yes,gotoItem2. ☒ No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky cybersecurityoranti-virussoftware. Item2.TechnicalRequirementsforKasperskyCybersecuritySoftware: #GeneralRequirements(ForallDevices)Yes/NoorN/AComments 1Internetconnectionforactivationandupdates(ForallOperating Systems) N/A DeviceCentraliteWaterLeakSensor CompanynameSafetyElectronicTechnology(Huizhou)Co.,Ltd. Granteecode2BVVZ FCCID2BVVZ-CLZ-3373-C FRN0038354429 ContactnameJackbu AddressA1004,JieshunTechnologyCenter,No.5 Guansheng2ndRoad,LuhuCommunity,Guanhu Street,LonghuaDistrict,Shenzhen,China Telephonenumber18906679427 [email protected] Chipset/moduleinformationMG21A02011 OperatingSystem(ifapplicable)N/A StorageCapacity(harddriveorother permanentmemorystorage,ifapplicable) N/A 2 #GeneralRequirements(ForWindowsDevices)Yes/NoorN/AComments 1Storage:1500MBfreespaceontheharddriveN/A 2OperatingSystem: MicrosoftWindows8,8.1,10&11Home/Pro/Enterprise Microsoft Windows7Starter/HomeBasic&Premium/Professional/ UltimateSP1orhigher N/A 3Processor:1GHzorhigher(x86orx64)N/A 4Memory(RAM)1GB(32-bit)or2GB(64-bit)N/A 5ScreenResolution:Minimumresolutionof1024x768N/A #GeneralRequirements(FormacOSdevices)Yes/NoorN/AComments 1OperatingSystemmacOS®13–14N/A 2Memory(RAM)4GBN/A 3Storage:3455MBfreespaceontheharddriveN/A #GeneralRequirements(ForAndroidDevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:Android™10–14N/A 3ScreenResolution:Minimumresolutionof320x480N/A #GeneralRequirements(foriOSdevices)Yes/NoorN/AComments 1Storage:150MBfreespaceN/A 2OperatingSystem:iOS®17N/A #GeneralRequirements(ForLinuxsystem)Yes/NoorN/AComments 3 1Harddrive:1GBoffreespaceN/A 2CPU:IntelPentium1GHzorhigherN/A 3RAM:1GBN/A 4Minimumsoftwarerequirements: AlmaLinuxOS8orlater; AlterOS7.5orlater; AstraLinuxCommonEdition2.12orlater; CentOS6.7orlater; DebianGNU/Linux10.0orlater; EulerOS2.0orlater; OracleLinux7.3orlater; RedHatEnterpriseLinux6.7orlater; RockyLinux8.5orlater; SUSELinuxEnterpriseServer12.5orlater; Ubuntu12.04orlater; UncomOSHome/Business/Education/Enterprise2.2orlater; ALTLinuxWorkstaton/WorkstationK/Server/Education8or later; ROSALinuxWorkstation/Server12orlater; REDOS7.3andlater; N/A Afterreviewedthetechnicalrequirements,isthedevicecapableofsupportingtheinstallationof Kasperskysoftware? ☐ Yes,gotoItem3. ☒No.Inthiscase,therestoftheitemsdonotapply.ThedevicecannotsupportinstallationofKaspersky software Item3.ConnectivityCapabilities: 4 #PhysicalInterfacePurposeJustification 1 1 #WirelessInterfacePurposeJustification 1 1 Afterthereviewofthisitems,thedevice: ☒Cannotsupportinstallationofanycybersecurityoranti-virussoftwareonthecoveredlist. ☐ Potentiallycanoperatewithanycybersecurityoranti-virussoftwareonthecoveredlist–additionalthird- partyproofisprovidedtodemonstratecompliancewithrequirementsasof2.911(d)5(i),(ii)–“Proofof CompliancewithCoveredListSoftwareRequirements”ofthisdocumentapplies ignature:Name:Jackbu Date:2026-4-29 1 Thejustificationfieldisusedtojustifywhythesoftwarecannotbereceivedthroughthatinterface.Checktheannexformore indications.

Attestation Statements

TCBCALLpágina1 1-IstheaddressoftheagentavalidphysicalUSmailingaddress(notaUSpostofficebox,notavirtualmailbox,notP.O.Boxes,notavacantlot,notapublicbuilding, etc. File FCC ID: 2BVVZ-CLZ-3373-C Please upload an exhibit that explains how does the TCB verify the new agent information: ) ○Wehavecheckediftheaddressexistsinarealandpotentialbuilding(Googlemaps)+officialUSregister,afterthisverificationandtheevidencebelowwecan guaranteethefollowing: notaUSpostofficebox notavirtualmailbox notP.O.Boxes notavacantlot notapublicbuilding(note) ►WecheckedtheFCCFRNSearchbasedontheinformationprovidedbythegrantee. Ontheofficialregisterfrom:Search|CaliforniaSecretaryofState TCBCALLpágina2 TCBCALLpágina3 TCBCALLpágina4 TCBCALLpágina5 TCBCALLpágina6 TCBCALLpágina7 TCBCALLpágina8 TCBCALLpágina9 ►CONCLUSIONbyTCB:TheASOPdefinedandprovidedbygranteeisVALIDandconfirmed.Thereforetheexhibit"C5266091_X23_Ed1_US_Agent_Letter" includedinthefileisok. 2-IstheagentphysicallylocatedatthatvalidUSaddresssuchthattheagentcanbelegallyservedatthataddress? Yes,checkabove 3-Hasthelistedagentclearlyagreedinwritingtoserveastheagentforthegranteeatthataddress? Yes,itisincludedintheexhibit"C5266091_X23_Ed1_US_Agent_Letter" >

Cover Letter(s)

C5266091_X10_Ed.2 1/1 SafetyElectronicTechnology(Huizhou)Co.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:2026.4.29 Subject:RequestforConfidentiality FCCID:2BVVZ-CLZ-3373-C ToWhomItMayConcern, PursuanttotheprovisionsofSections0.457and0.459ofCommission'srules (47CFR0.457,0.459),wearerequestingtheCommissiontowithholdthefollowing attachment(s)asconfidentialdocumentfrompublicdisclosure. ExhibitsLong-Term Confidentiality Short-Term Confidentiality NOTE2 IDLabel/LocationNoNo AttestationStatementNoNo ExternalPhotosNo ☐ BlockDiagram ☒☐ Schematics ☒☐ TestReportNoNo TestSetupPhotosNo ☐ User’sManual ☐ NOTE 1 ☐ InternalPhotos ☐ NOTE 1 ☐ PartsList/TuneUp ☐☐ RFExposureInfoNoNo OperationalDescription ☒☐ CoverLetter(s)NoNo SDRSoftware/SecurityInfo ☐ No NOTE1:Long-TermConfidentialitymaybepermittedunderspecialconditions(SeeII.LONG-TERMCONFIDENTIALITY,Section3of KDB726920,uselastinforce) NOTE2:Short-TermConfidentialitycanberequestedforamaximumof180daysfromthedateofthegrant. Abovementioneddocumentcontainsdetailedsystemandequipmentdescriptionare consideredasproprietaryinformationinoperationoftheequipment.Thepublic disclosureofabovedocumentsmightbeharmfultoourcompanyandwouldgive competitoranunfairadvantageinthemarket. Incaseofshort-termConfidentiality,theapplicantrequeststheexhibitsselected abovearewithheldfrompublicviewforaperiodof______daysfromthedateofthe GrantofEquipmentAuthorizationandpriortomarketing. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondentduringcertificationreviewprocesscannotbegrantedasconfidential documentsandthoseinformationwillbeavailableforpublicreviewoncethegrantof equipmentauthorizationisissued. Sincerely, C5266091_X10_Ed.2 1/1 Signature: Name:Jackbu Title:Manager 2026.4.29

Cover Letter(s)

C5266091_X8_Ed.1 1/1 LetterofAuthorization SafetyElectronicTechnology(Huizhou)Co.,Ltd. Company:SafetyElectronicTechnology(Huizhou)Co.,Ltd. Address:A1004,JieshunTechnologyCenter,No.5Guansheng2nd Road,LuhuCommunity,GuanhuStreet,LonghuaDistrict,Shenzhen, China. ProductName:CentraliteWaterLeakSensor ModelNumber:CLZ-3373-C FCCIdentifier:2BVVZ-CLZ-3373-C WeauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdelCarme,s/n, 08193Bellaterra,Spain,toactonourbehalfonallmattersconcerningthe abovenamedequipment. AnyindividualwithinLGAITechnologicalCenterS.A.isauthorizedtoactonour behalfandtakeactionontheapplication. WedeclarethatauthorizeLGAITechnologicalCenterS.A.,RondadelaFontdel Carme,s/n,08193Bellaterra,Spain,isallowedtoforwardallinformation relatedtotheapprovalprojecttotheFederalCommunicationCommissionand todiscussanyissuesconcerningtheapprovalapplication.Anyandallacts carriedoutbyLGAITechnologicalCenterS.A.onourbehalfshallhavethe sameeffectasactsofourown. Name:JackbuDate:2026.4.29 Title:Manager Signatureofapplicant:

External Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(External Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※

ID Label/Location Info

Size:26*12mm M/N: CLZ-3373-C FCC ID: 2BVVZ-CLZ-3373-C Label location

Internal Photos

Shenzhen DL Testing Technology Co., Ltd. EUT PHOTO(Internal Photos) Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. ※※※※※ END OF REPORT ※※※※※ Zigbee ANT

RF Exposure Info

FCC ID: 2BVVZ-CLZ-3373-C RF Exposure Evaluation Limits KDB 447498 D01 General RF Exposure Guidance v06 FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (minutes) (A) Limits for Occupational/Controlled Exposures 0.3–3.0 614 1.63 *(100) 6 3.0–30 1842/f 4.89/f *(900/f 2 ) 6 30–300 61.4 0.163 1.0 6 300–1500 f/300 6 1500–100,000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3–1.34 614 1.63 *(100) 30 1.34–30 824/f 2.19/f *(180/f 2 ) 30 30–300 27.5 0.073 0.2 30 300–1500 f/1500 30 1500–100,000 1.0 30 f = frequency in MHz Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 , Pout = output power to antenna in mW; G = gain of antenna in linear scale, Pi = 3.1416; R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. EIRP=EMeas+20log(dMeas)-104.7 EIRP is the equivalent isotropically radiated power, in dBm EMeas is the field strength of the emission at the measurement distance, in dBμV/m dMeas is the measurement distance, in m Test Result of RF Exposure Evaluation For zigbee Output power to antenna (dBm) Output power to antenna (mW) Power Density at R=20cm (mW/cm 2 ) Limit (mW/cm 2 ) Result 7.78 5.9979 0.00200 1.0 PASS Remark: antenna gain=2.42dBi

Test Report

Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260422013R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 1 of 32 FCC Part 15C Test Report FCC ID: 2BVVZ-CLZ-3373-C Applicant: Safety Electronic Technology (Huizhou) Co., Ltd Address: A1004, Jieshun Technology Center, No. 5 Guansheng 2nd Road, Luhu Community, Guanhu Street, Longhua District, Shenzhen, China Manufacturer: Safety Electronic Technology (Huizhou) Co., Ltd Address: 7th Floor, Unit 1, Building C1-3, Qunyi intelligent Manufacturing industrial Park, South of Sanhe Avenue, Tonghu Tow, Zhongkai High tech Zone, Huizhou, Guangdong, China Product Name: Centralite Water Leak Sensor Trade Mark: N/A Model Number: CLZ-3373-C Date of Receipt: Apr. 21, 2026 Test Date: Apr. 21, 2026 – Apr. 27, 2026 Date of Report: Apr. 27, 2026 Prepared By: Shenzhen DL Testing Technology Co., Ltd. Address: 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang District, Shenzhen, China Applicable Standards: FCC PART 15 C 15.247 ANSI C63.10-2020+Cor 1-2023 Test Result: Pass Report Number: DLE-260422013R Prepared (Test Engineer): Ken Tan Reviewer (Supervisor): Jack Bu Approved (Manager): Jade Yang This test report is based on a single evaluation of one sample of above mentioned products. It is not permitted to be duplicated in extracts without written approval of Shenzhen DL Testing Technology Co., Ltd. Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260422013R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 2 of 32 Table of Contents Page 1 . SUMMARY OF TEST RESULTS 4 1.1 MEASUREMENT UNCERTAINTY 4 2 . GENERAL INFORMATION 5 2.1 GENERAL DESCRIPTION OF EUT 5 2.2 DESCRIPTION OF TEST MODES 6 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 6 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 7 2.5 TABLE OF PARAMETERS OF TEST SOFTWARE SETTING 7 2.6 EQUIPMENTS LIST FOR ALL TEST ITEMS 8 3 . EMC EMISSION TEST 9 3.1 CONDUCTED EMISSION MEASUREMENT 9 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 9 3.1.2 TEST PROCEDURE 9 3.1.3 DEVIATION FROM TEST STANDARD 9 3.1.4 TEST SETUP 10 3.1.5 EUT OPERATING CONDITIONS 10 3.1.6 TEST RESULTS 10 3.2 RADIATED EMISSION MEASUREMENT 11 3.2.1 RADIATED EMISSION LIMITS 11 3.2.2 TEST PROCEDURE 12 3.2.3 DEVIATION FROM TEST STANDARD 12 3.2.4 TEST SETUP 12 3.2.5 EUT OPERATING CONDITIONS 13 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 14 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 15 3.2.8 TEST RESULTS (1GHZ~25GHZ) 17 3.3 RADIATED BAND EMISSION MEASUREMENT 18 3.3.1 TEST REQUIREMENT: 18 3.3.2 TEST PROCEDURE 18 3.3.3 DEVIATION FROM TEST STANDARD 18 3.3.4 TEST SETUP 19 3.3.5 EUT OPERATING CONDITIONS 19 3.4 CONDUCTED BAND EDGE EMISSION&CONDUCTED SPURIOUS EMISSIONS MEASUREMENT 21 3.4.1 APPLICABLE STANDARD 21 3.4.2 TEST PROCEDURE 21 3.4.3 DEVIATION FROM STANDARD 21 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260422013R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 3 of 32 Table of Contents Page 3.4.4 TEST SETUP 21 3.4.5 EUT OPERATION CONDITIONS 21 3.4.6 TEST RESULTS 21 4 . PEAK OUTPUT POWER 24 4.1 APPLIED PROCEDURES / LIMIT 24 4.1.1 TEST PROCEDURE 24 4.1.2 DEVIATION FROM STANDARD 24 4.1.3 TEST SETUP 24 4.1.4 EUT OPERATION CONDITIONS 24 4.1.5 TEST RESULTS 25 5 . POWER SPECTRAL DENSITY TEST 26 5.1 APPLIED PROCEDURES / LIMIT 26 5.1.1 TEST PROCEDURE 26 5.1.2 DEVIATION FROM STANDARD 26 5.1.3 TEST SETUP 26 5.1.4 EUT OPERATION CONDITIONS 26 5.1.5 TEST RESULTS 27 6 . 6DB BANDWIDTH TEST 29 6.1 APPLIED PROCEDURES / LIMIT 29 6.1.1 TEST PROCEDURE 29 6.1.2 DEVIATION FROM STANDARD 29 6.1.3 TEST SETUP 29 6.1.4 EUT OPERATION CONDITIONS 29 6.1.5 TEST RESULTS 30 7 . ANTENNA REQUIREMENT 32 7.1 STANDARD REQUIREMENT 32 7.2 EUT ANTENNA 32 8 . TEST SETUP PHOTO 32 9 . EUT PHOTO 32 Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260422013R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 4 of 32 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.205, 15.209, 15.247(d) Radiated Spurious Emission PASS 15.205, 15.247(d) Band Edge Emission& Conducted Spurious Emissions PASS 15.247(b) Peak Output Power PASS 15.247(a)(2) 6dB Bandwidth PASS 15.247(e) Power Spectral Density PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report 1.1 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±2.56dB 2 RF power,conducted ±0.42dB 3 Spurious emissions,conducted ±2.76dB 4 All emissions,radiated(<1G) ±3.65dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% 8 6dB Bandwidth ±0.2MHz 9 PSD ±0.42dB Shenzhen DL Testing Technology Co., Ltd. Report No.: DLE-260422013R Test Report Tel: 400-688-3552 Web:www.dl-cert.com Email: [email protected] Page 5 of 32 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product Name: Centralite Water Leak Sensor Trademark N/A Model Number: CLZ-3373-C Model Difference N/A Operation Frequency: 2405~2480 MHz Channel numbers: 16 Channels Channel separation: 5MHz Modulation technology: GFSK Antenna Type: Internal Antenna Antenna gain: 2.42dBi Power supply: DC 3V from battery Note: 1.For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2.The EUT’s all information provided by client. 2. Channel List Channel Frequency (MHz) Channel Frequency (MHz) 11 2405 19 2445 12 2410 20 2450 13 2415 21 2455 14 2420 22 2460 15 2425 23 2465 16 2430 24 2470 17 2435 25 2475 18 2440 26 2480 Shenzhen DL Testing Technology Co., Ltd. Report No.: …

Text truncated - open the document above for the full version.

Test Report

Antenna Internal Antenna Location of measurement(company name) Shenzhen Saifuli Electronic Technology Development Co., Ltd. Manufacturer: A1004, Jieshun Technology Center, No. 5 Guansheng 2nd Road, Luhu Community, Guanhu Street, Longhua District, Shenzhen, China 测试条件 Test Conditions 常温环境下温度:21°C, 湿度:50%RH Humidity:50%,Temperature:21°C, 测试设备 Test Equipment SATIMO-OTA实验室;CMW500;MT8000;E5071C等 SATIMO-OTA Lab, 测试环境 Test Ambient 温度(Temperature):____25___°C 湿度(Humidity):____40____RH 判定标准 Decision criteria 见下表TRP/TIS 故障判定标准 Look at the table of TRP and TIS 1.External View Drawing: Antenna Photo & Length (mm) Antenna Test Report 2. Antenna Test Data

Test Setup Photos

Shenzhen DL Testing Technology Co., Ltd. EUT TEST PHOTO Radiated Measurement Photos Shenzhen DL Testing Technology Co., Ltd. RF Conducted Test Photos ※※※※※ END OF REPORT ※※※※※

Contact Information

Applicant

Jack bu
[email protected]Fax: 18906679427

Technical Contact

Herland International Trading IncJianfeng Gao
[email protected]

Diamond Bar, California, 91765-3921 · United States

Test Firm

Shenzhen DL Testing Technology Co., Ltd.Jade Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz6.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Safety Electronic Technology (Huizhou) Co., Ltd

Centralite Indoor Entry Sensor - FCC ID 2BVVZ-CLZ-3372-C - Safety Electronic Technology (Huizhou) Co., Ltd
2BVVZ-CLZ-3372-C

Centralite Indoor Entry Sensor

Apr 30, 2026

Equipment Class

DTS - Digital Transmission System
Centralite Temperature & Humidity Sensor - FCC ID 2BVVZ-CLZ-3374-C - Safety Electronic Technology (Huizhou) Co., Ltd
2BVVZ-CLZ-3374-C

Centralite Temperature & Humidity Sensor

Apr 30, 2026

Equipment Class

DTS - Digital Transmission System
Centralite Indoor Entry Sensor w/ rechargeable battery - FCC ID 2BVVZ-CLZ-3371-C - Safety Electronic Technology (Huizhou) Co., Ltd
2BVVZ-CLZ-3371-C

Centralite Indoor Entry Sensor w/ rechargeable battery

Apr 30, 2026

Equipment Class

DTS - Digital Transmission System
Centralite Motion Sensor w/ rechargeable battery - FCC ID 2BVVZ-CLZ-3370-C - Safety Electronic Technology (Huizhou) Co., Ltd
2BVVZ-CLZ-3370-C

Centralite Motion Sensor w/ rechargeable battery

Apr 30, 2026

Equipment Class

DTS - Digital Transmission System