Equipment Class
DTS - Digital Transmission System
Date of Grant
May 26, 2026
Application Purpose
Original Equipment
Equipment Note
Skimmer Robot
Frequency Range
2402.00000000 - 2480.00000000
Company
Shenzhen Huoxin Jiyuan Intelligent Co., Ltd.
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China U.S. Agent Letter of Attestation To: Federal Communications Commission Date: 2026-04-29 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Attestation Statement – Part 2.911(d)(7) filing FCC ID: 2BVWJ-S1 Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd. (“the applicant”) certifies that, as of the date of the filing of the application Mars Register Agent LLC (“the agent”) is our designated U.S. agent for service of process for the above reference FCC ID. The applicant accepts to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges it is our responsibility to inform the FCC whenever the agent information changes. Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd (“the agent”) understand it is the agent's obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address. APPLICANT Company Name: Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Contact Person: Beibei Qian Address: Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China Tel.: +86 13026689225 Email: [email protected] FCC FRN: 0038354452 U.S. Agent Company Name: Mars Register Agent LLC Contact Person: Zhihui Peng Address:8932 Mission Dr, Unit 207, Rosemead, California 91770, United States Tel.: +1818-668-3208 Email: [email protected] FCC FRN:0038354452 Sincerely yours, The Applicant The Agent Company Name Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Mars Register Agent LLC Contact Person Beibei Qian Zhihui Peng Signature

Attestation Statements

Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 2026-04-29 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BVWJ-S1 Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Applicant Signature Print name: Beibei Qian Title: Product Manager Address: Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China Telephone: +86 13026689225 Email: [email protected]

Attestation Statements

Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 2026-04-29 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BVWJ-S1 Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Applicant Signature Print name: Beibei Qian Title: Product Manager Address: Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China Telephone: +86 13026689225 Email: [email protected]

Cover Letter(s)

Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China Page 1 of 1 TCB Authority to Act as Agent Date: 2026-04-29 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint _Jonathan Li/TÜV Rheinland (Shenzhen) Co., Ltd._ to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Xiamen Hanin Co.,Ltd./ Room 305A, Angye Building, Pioneering Park, Torch High-tech Zone, Xiamen City, Fujian Province, P.R. China. For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 2026-04-29 Agreement is valid for 12 months from the above date. By: __ ________________ Beibei Qian (Signature) (Print name) _Product Manager : +86 13026689225 (Title) (Telephone) On behalf of: Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd (Company Name)

Cover Letter(s)

Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenue, Shenzhen City, Guangdong Province, 51800, China MS-0044715 Page 1 of 1 Revision 1 TCB FCC Request for Confidentiality Letter Date: 2026-04-29 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BVWJ-S1 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Gain Information Datasheet Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecsting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of specify number of days not to exceed 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, Sincerely, By: ____________________ /__ Product Manager Beibei Qian __ (Signature/Title) (Print name) Telephone: +86 13026689225 Email: [email protected]

External Photos

FCC ID: 2BVWJ-S1 FCC ID: 2BVWJ-S1 FCC ID: 2BVWJ-S1 FCC ID: 2BVWJ-S1 FCC ID: 2BVWJ-S1

ID Label/Location Info

Label location

RF Exposure Info

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26O4C2 004 Auftrags-Nr.: Order no.: 168572468 Seite 1 von 9 Page 1 of 9 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-07-11 Auftraggeber: Client: Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenuw, Xili Community, Xili Street, Nanshan District, Shenzhen City, Guangdong Province Prüfgegenstand: Test item: Skimmer Robot Bezeichnung / Typ-Nr.: Identification / Type no.: S1 Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 2: Section 2.1091 Wareneingangsdatum: Date of sample receipt: 2025-11-15 Prüfmuster-Nr.: Test sample no: A004127548-001~002 Prüfzeitraum: Testing period: 2026-03-02 - 2026-03-18 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass Please refer to photo documents geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2026-05-12 Ausstellungsdatum: Issue date: 2026-05-12 Stellung / Position:Sachverständige(r)/ExpertStellung / Position:Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BVWJ-S1 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende:P(ass) = entspricht o.g. Prüfgrundlage(n)F(ail) = entspricht nicht o.g. Prüfgrundlage(n)N/A = nicht anwendbarN/T = nicht getestet * Legend:P(ass) = passed a.m. test specification(s)F(ail) = failed a.m. test specification(s)N/A = not applicableN/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26O4C2 004 Test report no.: Seite 2 von 9 Page 2 of 9 Anmerkungen Remarks 1Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision rule for statements of conformity, based …

Text truncated - open the document above for the full version.

Test Report

TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 地址:深圳市宝安区航空路锦驰中心3015 深圳市云顶通讯电子有限公司 SHENZHEN 客户 : 火芯纪元 品名规格 DESCRIPTION: FPC(SY-WIFI-01)-2.4G-1.13线-L90MM-IPEX1代 料号 PARTNO.: YD-C03-1527 客户料号 CUSPARTNO.: 日期 DATE : 2026-3-16 云顶呈样签章 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 业务 SALESDEPARTMENT 客户承认签章 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 采购 PURCHASINGDEPARTMENT 联系电话:075523073599 ж承认书一式三份,惠蒙贵司承认签章 жApprovalinduplicate,pleasesignedbyyourcompany. 承認書 APPROVALSHEET TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 地址:深圳市宝安区航空路锦驰中心3015 深圳市云顶通讯电子有限公司 SHENZHEN 1. 测试项目与设备 测试项目设备 1.S11参数 (S-parameter) 1.回波损耗(ReturnLoss) 2.电压驻波比(VSWR) 网络分析仪:AgilentE5071B HP8753D 2.有源测试 (Active) 1.发射功率(TRP) 2.接收灵敏度(TIS) 1.暗室:ETS7x4x3m(3D)Chamber ETS5x3x3m(3D)Chamber 2.综合测试仪:Agilent8960E5515B×2 StarPointSP6011Cmw500 3.无源测试 (Passive) 1.天线增益(Gain)2.天线效 率(Efficiency) 1.暗室:ETS7x4x3m(3D)Chamber ETS5x3x3m(3D)Chamber 2.网络分析仪:AgilentE5071B HP8753D TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 地址:深圳市宝安区航空路锦驰中心3015 深圳市云顶通讯电子有限公司 SHENZHEN 2. 天线性能 SWR TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 地址:深圳市宝安区航空路锦驰中心3015 深圳市云顶通讯电子有限公司 SHENZHEN 3. 天线效率与增益 Frequency/MhzEfficiency/%MaxGain/dBi 240058.882.87 241057.682.71 242055.852.66 243056.492.78 244055.852.69 245056.12.53 246055.462.48 247056.752.49 248056.892.47 249057.412.34 250057.812.35 TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 地址:深圳市宝安区航空路锦驰中心3015 深圳市云顶通讯电子有限公司 SHENZHEN 4. 天线结构图: TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 地址:深圳市宝安区航空路锦驰中心3015 深圳市云顶通讯电子有限公司 SHENZHEN 电器技术参数 电性能指标 ElectricalSpecifications 频率范围2400~2500MHz FrequencyRange 2400~2500MHz 电压驻波比≤2.0 VSWR ≤2.0 输入阻抗 50ΩInputImpedance50Ω 最大增益 2.87DBIMAXGain3.7DBI 机械指标 MechanicalSpecifications 天线颜色黑色 AntennaColorBlack 接口形式IPEX一代 InputconnectorIPEX1 天线线长 90mmCablelength90mm 工作温度-40°C~+85°C WorkingTemperature -40°C~+85°C 工作湿度 20~80%WorkingHumidity20~80%

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26O4C2 002 Auftrags-Nr.: Order no.: 168572468 Seite 1 von 23 Page 1 of 23 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-07-11 Auftraggeber: Client: Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenuw, Xili Community, Xili Street, Nanshan District, Shenzhen City, Guangdong Province Prüfgegenstand: Test item: Skimmer Robot Bezeichnung / Typ-Nr.: Identification / Type no.: S1 Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15: Subpart C Section 15.247 Wareneingangsdatum: Date of sample receipt: 2025-11-15 Please refer to photo documents Prüfmuster-Nr.: Test sample no: A004127548-001~002 Prüfzeitraum: Testing period: 2026-03-02 - 2026-03-18 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2026-05-12 Ausstellungsdatum: Issue date: 2026-05-12 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BVWJ-S1 This report is for 2.4GHz Wi-Fi. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26O4C2 002 Test report no.: Seite 2 von 23 Page 2 of 23 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC …

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26O4C2 003 Auftrags-Nr.: Order no.: 168572468 Seite 1 von 22 Page 1 of 22 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2025-07-11 Auftraggeber: Client: Shenzhen Huoxin Jiyuan Intelligent Co.,Ltd Room 1208, Block C, Building 1, Section 1, Chuangzhi Yuncheng, Liuxian Avenuw, Xili Community, Xili Street, Nanshan District, Shenzhen City, Guangdong Province Prüfgegenstand: Test item: Skimmer Robot Bezeichnung / Typ-Nr.: Identification / Type no.: S1 Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15: Subpart C Section 15.247 Wareneingangsdatum: Date of sample receipt: 2025-11-15 Prüfmuster-Nr.: Test sample no: A004127548-001~002 Prüfzeitraum: Testing period: 2026-03-02 - 2026-03-18 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass Please refer to photo documents geprüft von: tested by: genehmigt von: authorized by: Datum: Date: 2026-05-12 Ausstellungsdatum: Issue date: 2026-05-12 Stellung / Position:Sachverständige(r)/ExpertStellung / Position:Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BVWJ-S1 This report is for BLE. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende:P(ass) = entspricht o.g. Prüfgrundlage(n)F(ail) = entspricht nicht o.g. Prüfgrundlage(n)N/A = nicht anwendbarN/T = nicht getestet * Legend:P(ass) = passed a.m. test specification(s)F(ail) = failed a.m. test specification(s)N/A = not applicableN/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26O4C2 003 Test report no.: Seite 2 von 22 Page 2 of 22 Anmerkungen Remarks 1Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decision ru…

Text truncated - open the document above for the full version.

Test Setup Photos

Prüfbericht - Produkte Test Report - Products Appendix B CN26O4C2 003 Page 1 of 3 Appendix B: Photographs of the Test Set-Up APPENDIX B: PHOTOGRAPHS OF THE TEST SET-UP ....................................................................................................... 1 PHOTOGRAPH 1: SET-UP PHOTO FOR RADIATED SPURIOUS EMISSION, BELOW 1GHZ ......................................................................... 2 PHOTOGRAPH 2: SET-UP PHOTO FOR RADIATED SPURIOUS EMISSION, ABOVE 1GHZ ......................................................................... 2 PHOTOGRAPH 3: SET-UP PHOTO FOR CONDUCTED EMISSION ......................................................................................................... 3 Prüfbericht - Produkte Test Report - Products Appendix B CN26O4C2 003 Page 2 of 3 Photograph 1: Set-up photo for Radiated Spurious Emission, Below 1GHz Photograph 2: Set-up photo for Radiated Spurious Emission, Above 1GHz Prüfbericht - Produkte Test Report - Products Appendix B CN26O4C2 003 Page 3 of 3 Photograph 3: Set-up photo for Conducted Emission

Contact Information

Applicant

Beibei Qian
[email protected]Fax: +8617688539225

Technical Contact

Mars Register Agent LLCZhihui Peng
[email protected]

8932 Mission Dr, Unit 207 · Rosemead, California, 91770 · United States

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz309.00 mW
215C2.40 GHz - 2.48 GHz19.00 mW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End user must be provided with transmitter operating conditions for satisfying RF exposure compliance.