2BVWL-VOLTASMART ELECTRIC HEATING DEVICE

SHX CORPORATION

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 05, 2026
Application Purpose
Original Equipment
Equipment Note
SMART ELECTRIC HEATING DEVICE
Frequency Range
2402.00000000 - 2480.00000000
Company
SHX CORPORATION
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

SHXCORPORATION. To:FederalCommunicationsCommissionDate:2026/5/28 7435OaklandMillsRoad Columbia,MD21046 USA Attestation Section2.911(d)(5)(i)andSection2.911(d)(5)(ii) (KDB986446D01CoveredEquipment) Section2.911(d)(5)(i) SHXCORPORATION.(“theapplicant”)certifiesthattheequipmentforwhich authorizationissoughtisnot“covered”equipmentprohibitedfromreceivingan equipmentauthorizationpursuanttosection2.903oftheFCCrules. Section2.911(d)(5)(ii) SHXCORPORATION(“theapplicant”)certifiesthat,asofthedateofthefilingofthe application,theapplicant[isnot]identifiedontheCoveredList(asaspecifically namedentityoranyofitssubsidiariesoraffiliates)asanentityproducing“covered” equipment. TypeofEquipmentsubjecttoFCCCertification:SMARTELECTRICHEATING DEVICE FCCID:2BVWL-VOLTA Ifyouhaveanyquestions,pleasefeelfreetocontactme. ContactPerson:KristinaTabakharniuk PositionintheCompany:GeneralManager DateofSignature:2026/5/28 ___________________________ Signatory (signatureoftheapplicant)

Cover Letter(s)

SHXCORPORATION. PHOENIXTESTLABGmbHDate:03June2026 ProductCertification Königswinkel10 D32825Blomberg FCCID:2BVWL-VOLTA ToWhomItMayConcerns, Pursuanttosections0.457(d)and0.459ofCFR47andtoavoidprematurereleaseof sensitiveinformationpriortomarketingorreleaseoftheproducttothepublic,wehereby requestlong-termconfidentialtreatmentofinformationaccompanyingthisapplicationas outlinedbelow: ☒Schematics☐PartsList ☒BlockDiagram☐Tune-UpInfo ☒OperationalDescription ☐ securityinformation Inadditionweherebyrequestthefollowingexhibitscontainedinthisapplicationtobe temporarily(short-termconfidentiality)withheldfromthepublicdisclosure ☒foraninitialperiodof180days☐until:☐not applicable ☒ExternalPhotos☒TestSetupPhotos ☒InternalPhotos☒UsersManual Theabovematerialscontaintradesecretsandproprietaryinformationnotcustomarily releasedtothepublic.Thepublicdisclosureofthesemattersmightbeharmfultothe applicantandprovideunjustifiedbenefitstoitscompetitors. Theapplicantunderstandsthatpursuanttorule0.457(d),disclosureofthisapplicationand allaccompanyingdocumentationwillnotbemadebeforethedateoftheGRANTforthis application. Ifyouhaveanyquestions,pleasefeelfreetocontactme. Yourssincerely, Signatory PrintedName:KristinaTabakharniuk Position:GeneralManager

ID Label/Location Info

Page 1 of 1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION Material: tagboard Glue: adhesive sticker Front color: black Label color: White (Size: L3.0cm x W2.0cm) SMART ELECTRIC HEATING DEVICE Model/HVIN: VOLTA FCC ID: 2BVWL-VOLTA IC: 35521-VOLTA Label Location

RF Exposure Info

Page 1 of 11 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation For SHX CORPORATION SMART ELECTRIC HEATING DEVICE Test Model: VOLTA Prepared for : SHX CORPORATION Address : 1602 Lockness Place, Torrance, California 90501 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 27, 2026 Number of tested samples : 2 Sample No. : A260427001-1, A260427001-2 Serial number : Prototype Date of Test : April 27, 2026 ~ May 15, 2026 Date of Report : May 18, 2026 Page 2 of 11 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report Reference No. ................. : LCSA04276071EC Date of Issue ................................... : May 18, 2026 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : SHX CORPORATION Address ........................................... : 1602 Lockness Place, Torrance, California 90501 Test Specification Standard.......................................... : FCC KDB publication 447498 D01 General RF Exposure Guidance v06 FCC CFR 47 part1 1.1310 FCC CFR 47 part2 2.1091 Test Report Form No. ................... : TRF-4-E-214 A/0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : SMART ELECTRIC HEATING DEVICE Trade Mark ...................................... : Test Model ...................................... : VOLTA Ratings ............................................ : Please Refer to Page 6 Result ............................................ : PASS Compiled by: Reviewed by: Approved by: Vera Deng/ Administrator Kevin Huang/ RF Manager Gavin Liang/ Manager Page 3 of 11 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Test Result PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA04276071EC May 18, 2026 Date of issue Test Model.............................. : VOLTA EUT......................................... : SMART ELECTRIC HEATING DEVICE Applicant............................... : SHX CORPORATION Address................................... : 1602 Lockness Place, Torrance, California 90501 Telephone............................... : / Fax.......................................... : / Manufacturer......................... : SHX CORPORATION Address................................... : 1602 Lockness Place, Torrance, California 90501 Telephone............................... : / Fax.......................................... : / Factory................................... : FOCUS HI-TECH CO.,LTD Address................................... : Building C,Jingfukang Industrial zone, FengHuang Road No.9, Torch development district, Zhongshan, China, 528437 Telephone............................... : / Fax.......................................... : / Page 4 of 11 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 May 18, 2026 Initial Issue --- Page 5 of 11 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EC Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS Description Page 1. Product Information .................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix B RF Test Data for 2.4GWIFI (Conducted Measurement) Product Name: SMART ELECTRIC HEATING DEVICE Test Model: VOLTA Environmental Conditions Temperature: 23.7C Relative Humidity: 54.6% ATM Pressure: 100.0 kPa Test Engineer: Jerry Chu Supervised by: Can Kun Page 2 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity B.1 -6dB Bandwidth Condition Mode Frequency (MHz) Antenna -6 dB Bandwidth (MHz) Limit -6 dB Bandwidth (MHz) Verdict NVNT b 2412 Ant1 9.089 0.5 Pass NVNT b 2437 Ant1 9.102 0.5 Pass NVNT b 2462 Ant1 9.116 0.5 Pass NVNT g 2412 Ant1 16.29 0.5 Pass NVNT g 2437 Ant1 16.35 0.5 Pass NVNT g 2462 Ant1 16.4 0.5 Pass NVNT n20 2412 Ant1 17.37 0.5 Pass NVNT n20 2437 Ant1 17.22 0.5 Pass NVNT n20 2462 Ant1 17.48 0.5 Pass NVNT n40 2422 Ant1 35.82 0.5 Pass NVNT n40 2437 Ant1 35.9 0.5 Pass NVNT n40 2452 Ant1 35.9 0.5 Pass Note :offset=System attenuation +cabal loss Page 3 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2412MHz Ant1 Page 4 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2437MHz Ant1 Page 5 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT b 2462MHz Ant1 Page 6 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2412MHz Ant1 Page 7 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2437MHz Ant1 Page 8 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT g 2462MHz Ant1 Page 9 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2412MHz Ant1 Page 10 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2437MHz Ant1 Page 11 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n20 2462MHz Ant1 Page 12 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n40 2422MHz Ant1 Page 13 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -6dB Bandwidth NVNT n40 2437MHz Ant1 Page 14 of 101 FCC-ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzh…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 35 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For SHX CORPORATION SMART ELECTRIC HEATING DEVICE Test Model: VOLTA Prepared for : SHX CORPORATION Address : 1602 Lockness Place, Torrance, California 90501 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 27, 2026 Number of tested samples : 2 Sample No. : A260427001-1, A260427001-2 Serial number : Prototype Date of Test : April 27, 2026 ~ May 15, 2026 Date of Report : May 18, 2026 Page 2 of 35 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA04276071EA Date of Issue ................................... : May 18, 2026 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : SHX CORPORATION Address ........................................... : 1602 Lockness Place, Torrance, California 90501 Test Specification Standard.......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. ................... : TRF-4-E-145 A/0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : SMART ELECTRIC HEATING DEVICE Trade Mark ...................................... : Test Model ...................................... : VOLTA Ratings ............................................ : Please Refer to Page 6 Result ............................................ : PASS Compiled by: Reviewed by: Approved by: Vera Deng/ Administrator Kevin Huang/ RF Manager Gavin Liang/ Manager Page 3 of 35 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Result PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA04276071EA May 18, 2026 Date of issue Test Model.............................. : VOLTA EUT......................................... : SMART ELECTRIC HEATING DEVICE Applicant............................... : SHX CORPORATION Address................................... : 1602 Lockness Place, Torrance, California 90501 Telephone............................... : / Fax.......................................... : / Manufacturer......................... : SHX CORPORATION Address................................... : 1602 Lockness Place, Torrance, California 90501 Telephone............................... : / Fax.......................................... : / Factory................................... : FOCUS HI-TECH CO.,LTD Address................................... : Building C,Jingfukang Industrial zone, FengHuang Road No.9, Torch development district, Zhongshan, China, 528437 Telephone............................... : / Fax.......................................... : / Page 4 of 35 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 May 18, 2026 Initial Issue --- Page 5 of 35 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION ........................................................................................................................ 6 1.1. DESCRIPTION OF DEVICE (EUT) ..............................................…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 36 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For SHX CORPORATION SMART ELECTRIC HEATING DEVICE Test Model: VOLTA Prepared for : SHX CORPORATION Address : 1602 Lockness Place, Torrance, California 90501 Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 27, 2026 Number of tested samples : 2 Sample number : A260427001-1, A260427001-2 Serial number : Prototype Date of Test : April 27, 2026 ~ May 15, 2026 Date of Report : May 18, 2026 Page 2 of 36 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.247) Report Reference No. ................. : LCSA04276071EB Date of Issue ................................... : May 18, 2026 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ........... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .......................... : SHX CORPORATION Address ........................................... : 1602 Lockness Place, Torrance, California 90501 Test Specification Standard .......................................... : FCC CFR 47 PART 15 C(15.247) Test Report Form No. ................... : TRF-4-E-147 A/0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : SMART ELECTRIC HEATING DEVICE Trade Mark ...................................... : Test Model ...................................... : VOLTA Ratings ............................................ : Please Refer to Page 6 Result ........................................... : PASS Compiled by: Reviewed by: Approved by: Vera Deng/ Administrator Kevin Huang/ RF Manager Gavin Liang/ Manager Page 3 of 36 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Result PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA04276071EB May 18, 2026 Date of issue Test Model.............................. : VOLTA EUT......................................... : SMART ELECTRIC HEATING DEVICE Applicant............................... : SHX CORPORATION Address................................... : 1602 Lockness Place, Torrance, California 90501 Telephone............................... : / Fax.......................................... : / Manufacturer......................... : SHX CORPORATION Address................................... : 1602 Lockness Place, Torrance, California 90501 Telephone............................... : / Fax.......................................... : / Factory................................... : FOCUS HI-TECH CO.,LTD Address................................... : Building C,Jingfukang Industrial zone, FengHuang Road No.9, Torch development district, Zhongshan, China, 528437 Telephone............................... : / Fax.......................................... : / Page 4 of 36 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 May 18, 2026 Initial Issue -- Page 5 of 36 FCC ID: 2BVWL-VOLTA Report No.: LCSA04276071EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION ........................................................................................................................ 6 1.1. DESCRIPTION OF DEVICE (EUT) ............................................…

Text truncated - open the document above for the full version.

Test Report

2026 Antenna Matching Test Report Customer: Zhongshan Jutailai Electronic Technology Co., Ltd.Test Date: March 17, 2026 Engineer Chen: 18028016875 Guangzhou Hanwuji Electronic Technology Co., Ltd. 2026/3/17 Guangzhou Hanwuji Electronic Technology Co., Ltd.:Contact Person: Engineer Chen,18028016875 Table of Contents Table of Contents..............................................................................................................................1 OA‐FW4006Antenna2.4GCoaxialCable10cmIPEX4thGeneration......................................................2 I Matching Debug Data ..............................................................................................................3 Antenna Matching Schematic Diagram After Debug .......................................................3 II S‐ParameterTest.......................................................................................................................4 Overall Test Environment .................................................................................................4 Antenna VSWR ..........................................................................................................................5 Return Loss ............................................................................................................................5 III 3DMicrowaveChamberTest....................................................................................................6 Gain and Efficiency Table ..................................................................................................7 Chamber Direction Diagram ..................................................................................................7 Product Chamber Test Environment Picture ....................................................................8 3DRadiationPattern ..............................................................................................................9 1 OA-FW4006 Antenna 2.4G Coaxial Cable 10cm IPEX 4th Generation2 Guangzhou Hanwuji Electronic Technology Co., Ltd.:Contact Person: Engineer Chen,18028016875 Guangzhou Hanwuji Electronic Technology Co., Ltd.:Contact Person: Engineer Chen,18028016875 IMatching Debug Data Antenna Matching Schematic Diagram After Debug Note: The peripheral component values required by the RF chip reference design shall be used in accordance with the chip manufacturer’s reference design. The above antenna matching components are independent of each other and cannot be replaced with each other. 2nH SDCL1005C2N0STDF 0402CG2R2C500NT Sunlord(顺络) FH(风华) 2.2pF 3 Guangzhou Hanwuji Electronic Technology Co., Ltd.:Contact Person: Engineer Chen,18028016875 II S-Parameter Test EquipmentModels:E5062A,ZVB8,N9020A Overall Test Environment 4 Guangzhou Hanwuji Electronic Technology Co., Ltd.:Contact Person: Engineer Chen,18028016875 Antenna VSWR Return Loss 5 Guangzhou Hanwuji Electronic Technology Co., Ltd.:Contact Person: Engineer Chen,18028016875 III 3DMicrowaveChamberTest Equipment Models: ATS‐200 、 E5071C 、 CMW50 6 Guangzhou Hanwuji Electronic Technology Co., Ltd.:Contact Person: Engineer Chen,18028016875 Gain and Efficiency Table              !    …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Kristina Tabakharniuk
[email protected]Fax: 1 (417) 924-0365

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place · Fullerton, California, 92835 · United States

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.20 mW
215C2.41 GHz - 2.46 GHz37.00 mW
Confidentiality
Long Term
Grant Notes
WiFi Output power is maximum average conducted. <br> BLE Output power is maximum peak conducted. <br> This device supports IEEE 802.11 b/g/n20 and 40 MHz channel bandwidths. <br> This device must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with the transmitter operating conditions for satisfying RF exposure compliance