FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Moen Incorporated/
  3. 2BVX2-920010

2BVX2-920010Smart Water Detector

Moen Incorporated

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jun 26, 2026
Application Purpose
Original Equipment
Equipment Note
Smart Water Detector
Frequency Range
2412.00000000 - 2462.00000000
Company
Moen Incorporated
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗
↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Moen Incorporated Certification Designating a U.S. Agent for Service of Process Date: 23-05-2026 To: Federal Communications Commission 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Section 2.911(d)(7) filing FCC ID: 2BVX1-920010 [Moen Incorporated] (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC ID. The applicant acknowledges that they will maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the agent information changes. FCC US Agent from Applicant Company Company Name: Moen Incorporated Contact Name: Andrew Posta Address: 25300 Al Moen Dr, North Olmsted, OH 44070 United States Phone No.: (440) 962-2000 Email Address: [email protected] FCC FRN (optional): 0038382065 Sincerely yours, Andrew Posta Applicant Signature Printed Name: Andrew Posta Title: Senior Compliance Engineer Email: [email protected]

Attestation Statements

Moen Incorporated Attestation Statements Not Covered Entity Applicant To: Federal Communications Commission Date: 23-05-2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(ii) filing FCC ID: 2BVX1-920010 Moen Incorporated (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely yours, Andrew Posta Applicant Signature Printed Name: Andrew Posta Title: Senior Compliance Engineer Address: 25300 Al Moen Dr, North Olmsted, OH 44070 United States Tel.: (440) 962-2000 Email: [email protected]

Attestation Statements

Moen Incorporated Attestation Statements Not Covered Equipment To: Federal Communications Commission Date: 23-05-2026 7435 Oakland Mills Road, Columbia, MD 21046, USA Ref: Information Required by Section 2.911(d)(5)(i) filing FCC ID: 2BVX1-920010 Moen Incorporated (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section § 2.903 of the FCC rules. Sincerely yours, Andrew Posta Applicant Signature Printed Name: Andrew Posta Title: Senior Compliance Engineer Address: 25300 Al Moen Dr, North Olmsted, OH 44070 United States Tel.: (440) 962-2000 Email: [email protected]

Cover Letter(s)

TCB Authority to Act as Agent Number: MS-0045317 Revision: 0 Effective date: Oct 8, 2021 Page 1 of 1 Authority to Act as Agent Date: 27 Mai 2026 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TUV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Moen Incorporated / 25300 Al Moen Dr, North Olmsted, OH 44070 United States For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 12 Months Agreement is valid for 12 months from the above date. By: __ Andrew Posta Andrew Posta (Signature) (Print name) (440) 962-2000 (Title: Senior Compliance Engineer) (Telephone) On behalf of: Moen Incorporated (Company Name)

Cover Letter(s)

Moen Incorporated MS-0044715 Page 1 of 1 Revision 1 Date: __2026.05.23___ Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road, Columbia, MD 21046, USA Subject: Confidentiality Request for FCC ID: 2BVX1-920010 Pursuant to FCC 47 CRF 0.457(d), the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term n/a External Photo Short Term Permanent Internal Photos *** Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Schematics Short Term Permanent Test Setup*** Short Term Permanent Tune-Up Procedure Short Term Permanent User’s Manual*** Short Term Permanent Part List/ Antenna Construction Moen Incorporated has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. (*** Exceptional case for Permanent Confidentiality for these Exhibits by PAG only) Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: _____ Andrew Posta _______ Andrew Posta Signature/ Senior Compliance Engineer (Print name) Tel: (440) 962-2000 Email: [email protected]

RF Exposure Info

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26O08Z 003 Auftrags-Nr.: Order no.: 27223943 Seite 1 von 9 Page 1 of 9 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2026-03-13 Auftraggeber: Client: Moen Incorporated 25300 Al Moen Dr, North Olmsted, OH 44070 United States Prüfgegenstand: Test item: Smart Leak Detector Bezeichnung / Typ-Nr.: Identification / Type no.: 920-010, 920-011 (3 pack) (Trademark: Moen) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 2: Section 2.1091 RSS-102 Issue 6 December 2023 Wareneingangsdatum: Date of sample receipt: 2026-03-14 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004223725-002~007 Prüfzeitraum: Testing period: 2026-03-17 - 2026-04-20 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Breeze Jiang genehmigt von: authorized by: Datum: Date: 2026-04-24 Ausstellungsdatum: Issue date: 2026-04-24 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BVX2-920010 IC: 35553-920010 HVIN: 920010A Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR X Signed by: Bell Hu Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26O08Z 003 Test report no.: Seite 2 von 9 Page 2 of 9 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheidungsregel siehe ILAC G8:2019. The decisio…

Text truncated - open the document above for the full version.

Test Report

SPECIFICATION Shenzhen Strongpower Communication Co., Ltd ShenzhenStrongpowerCommunicationCo.,Ltd SPECIFICATION CustomerSolex Frequency Band 2400MHz-2500MHz ModelB39040 RF designer Zheng Zhou Structural engineer Peng Yaohui Technical director Fu YichengDate2026/4/29 Antenna Type Steel plate antenna Company Address Shenzhen Ruiqiang Communication Co., Ltd. Address: Room 502, W2-A, High-Tech Industrial Village, South High-Tech 4th Road, Nanshan District, Shenzhen Manufacturer Address Shenzhen Zhongxinda Hardware Spring Products Co., Ltd. Address:Room 101, Building 1, Area B, Zhuyin Lake Industrial Park, No.1 Huangshan Road, Qingxi Town, Dongguan City Confirm by customer : Confidential Information Page 2 Contents 1.TheEquipmentofActive&PassiveTest............................................................................................................3 2.Passive Test Data...................................................................................................................................................... 4 2.1 S-Parameters (Free Space)...................................................................................................................................... 4 2.2 Efficiency and Gain (Free Space)........................................................................................................................... 4 2.3 Passive Radiation Pattern (Free Space).................................................................................................................. 5 3 . MatchingCircuit.................................................................................................................................................... 5 4.Engineeringdrawing...............................................................................................................................................5 Confidential Information Page 3 1. TheEquipmentofActive&PassiveTest Confidential Information Page 4 2.PassiveTestData 2.1 S-Parameters (Free Space) 2.2 Efficiency and Gain (Free Space) Frequency/MhzEfficiency/%Efficiency/dBMaxGain/dBi 2400 66.99-1.743.75 2410 65.77-1.824.18 2420 68.87-1.624.44 2430 67.76-1.694.63 2440 70.47-1.524.75 2450 71.12-1.484.72 2460 73.28-1.354.59 2470 71.61-1.454.28 2480 72.95-1.373.93 2490 72.28-1.413.5 2500 72.95-1.373.12 AVG70.37 -1.534.17 Confidential Information Page 5 2.3 Passive Radiation Pattern (Free Space) 3 . MatchingCircuit MatchingE1E2E3 ValueNC1NH1.2PF 4.Engineeringdrawing (seenextpage) Shenzhen Ruiqiang Communication Co., Ltd. NOTES: 1.Dimensions marked with * are key dimensions (must be controlled within the specified tolerances). Undimensioned fillets: R0.2mm. Undimensioned tolerances shall comply with drawing specifications. The dimensional tolerance of all notches and holes is ±0.05mm, and the burr height shall not exceed 0.02mm. 2.Material of shrapnel: 304 stainless steel with nickel plating. 3.24-hour salt spray test pass required. 4.All materials shall comply with the environmental ROHS standards.

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: CN26O08Z 002 Auftrags-Nr.: Order no.: 27223943 Seite 1 von 19 Page 1 of 19 Kunden-Referenz-Nr.: Client reference no.: N/A Auftragsdatum: Order date: 2026-03-13 Auftraggeber: Client: Moen Incorporated 25300 Al Moen Dr, North Olmsted, OH 44070 United States Prüfgegenstand: Test item: Smart Leak Detector Bezeichnung / Typ-Nr.: Identification / Type no.: 920-010, 920-011 (3 pack) (Trademark: Moen) Auftrags-Inhalt: Order content: Test Report Prüfgrundlage: Test specification: CFR Title 47 FCC Part 15: Subpart C Section 15.247 RSS-247 Issue 4 July 2025 RSS-Gen Issue 5 February 2021 Wareneingangsdatum: Date of sample receipt: 2026-03-14 Please refer to Photo Document Prüfmuster-Nr.: Test sample no: A004223725-002~007 Prüfzeitraum: Testing period: 2026-03-17 - 2026-04-20 Ort der Prüfung: Place of testing: TÜV Rheinland (Shenzhen) Co., Ltd. Prüflaboratorium: Testing laboratory: TÜV Rheinland (Shenzhen) Co., Ltd. Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Breeze Jiang genehmigt von: authorized by: Datum: Date: 2026-06-02 Ausstellungsdatum: Issue date: 2026-06-02 Stellung / Position: Sachverständige(r)/Expert Stellung / Position: Sachverständige(r)/Expert Sonstiges / Other: FCC ID: 2BVX2-920010 IC: 35553-920010 HVIN: 920010A Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TUV Rheinland (Shenzhen) Co., Ltd., 1601-1604, 1801-1804, Tower A Building 2, Shenzhen International Innovation Valley, Dashi 1st Road, Xili Street, Xili Community, Nanshan District, Shenzhen, 518000 Mail: [email protected] · Web: www.tuv.com V101023GCNSR X Signed by: Bell Hu Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: CN26O08Z 002 Test report no.: Seite 2 von 19 Page 2 of 19 Anmerkungen Remarks 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezueglich des Risikos durch diese Entscheid…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 1 of 83 Appendix A: Test Results of 2.4GHz Wi-Fi APPENDIX A: TEST RESULTS OF 2.4GHZ WI-FI ................................................................................................................ 1 APPENDIX A.1: TEST RESULTS OF 6DB BANDWIDTH .............................................................................................................. 2 Test Result ............................................................................................................................................................. 2 Test Graphs ........................................................................................................................................................... 3 APPENDIX A.2: TEST RESULTS OF 99% BANDWIDTH ............................................................................................................. 8 Test Result ............................................................................................................................................................. 8 Test Graphs ........................................................................................................................................................... 9 APPENDIX A.3: TEST RESULTS OF CONDUCTED POWER SPECTRAL DENSITY ............................................................................... 14 Test Result ........................................................................................................................................................... 14 Test Graphs ......................................................................................................................................................... 15 APPENDIX A.4: TEST RESULTS OF BAND EDGE MEASUREMENTS ............................................................................................. 20 Test Result ........................................................................................................................................................... 20 Test Graphs ......................................................................................................................................................... 21 APPENDIX A.5: TEST RESULTS OF CONDUCTED SPURIOUS EMISSIONS ...................................................................................... 24 Test Result ........................................................................................................................................................... 24 Test Graphs ......................................................................................................................................................... 25 APPENDIX A.6: TEST RESULTS OF RADIATED SPURIOUS EMISSIONS ......................................................................................... 38 30MHz - 1GHz, W25Q32JVSSIQ ............................................................................................................................ 38 1GHz - 18GHz, W25Q32JVSSIQ ............................................................................................................................. 40 1GHz - 18GHz, ZB25VQ32BSIG.............................................................................................................................. 52 1GHz - 18GHz, GD25Q32ESIGR ............................................................................................................................. 56 APPENDIX A.7: TEST RESULTS OF RADIATED EMISSIONS IN RESTRICTED BANDS ......................................................................... 60 W25Q32JVSSIQ .................................................................................................................................................... 60 ZB25VQ32BSIG .................................................................................................................................................... 76 GD25Q32ESIGR .................................................................................................................................................... 80 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 2 of 83 Appendix A.1: Test Results of 6dB Bandwidth Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 8.840 2407.480 2416.320 0.5 PASS 2437 8.760 2432.480 2441.240 0.5 PASS 2462 8.920 2457.360 2466.280 0.5 PASS 11G Ant1 2412 16.320 2403.840 2420.160 0.5 PASS 2437 16.160 2428.920 2445.080 0.5 PASS 2462 16.280 2453.880 2470.160 0.5 PASS 11N20SISO Ant1 2412 17.040 2403.440 2420.480 0.5 PASS 2437 17.080 2428.480 2445.560 0.5 PASS 2462 16.880 2453.600 2470.480 0.5 PASS 11N40SISO Ant1 2422 33.360 2405.440 2438.800 0.5 PASS 2437 32.800 2420.600 2453.400 0.5 PASS 2452 32.480 2435.600 2468.080 0.5 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 3 of 83 Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 4 of 83 11G_Ant1_2412 11G_Ant1_2437 11G_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 5 of 83 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 6 of 83 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 7 of 83 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 8 of 83 Appendix A.2: Test Results of 99% Bandwidth Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 12.978 2405.4738 2418.4518 --- PASS 2437 13.027 2430.4321 2443.4591 --- PASS 2462 12.987 2455.4602 2468.4472 --- PASS 11G Ant1 2412 16.519 2403.7268 2420.2458 --- PASS 2437 16.564 2428.6968 2445.2608 --- PASS 2462 16.573 2453.6965 2470.2695 --- PASS 11N20SISO Ant1…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 24 of 83 Appendix A.5: Test Results of Conducted Spurious Emissions Test Result TestMode Antenna Channel FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11B Ant1 2412 Reference 1.28 1.28 --- PASS 30~1000 1.28 -28.19 ≤-18.72 PASS 1000~26500 1.28 -37.07 ≤-18.72 PASS 2437 Reference 0.02 0.02 --- PASS 30~1000 0.02 -28.42 ≤-19.98 PASS 1000~26500 0.02 -37.64 ≤-19.98 PASS 2462 Reference 0.94 0.94 --- PASS 30~1000 0.94 -28.32 ≤-19.06 PASS 1000~26500 0.94 -37.57 ≤-19.06 PASS 11G Ant1 2412 Reference 0.30 0.30 --- PASS 30~1000 0.30 -28.08 ≤-19.7 PASS 1000~26500 0.30 -36.15 ≤-19.7 PASS 2437 Reference -0.24 -0.24 --- PASS 30~1000 -0.24 -28.2 ≤-20.24 PASS 1000~26500 -0.24 -36.26 ≤-20.24 PASS 2462 Reference 0.22 0.22 --- PASS 30~1000 0.22 -28.11 ≤-19.78 PASS 1000~26500 0.22 -35.37 ≤-19.78 PASS 11N20SISO Ant1 2412 Reference -0.19 -0.19 --- PASS 30~1000 -0.19 -27.97 ≤-20.19 PASS 1000~26500 -0.19 -36.3 ≤-20.19 PASS 2437 Reference -0.41 -0.41 --- PASS 30~1000 -0.41 -28.11 ≤-20.41 PASS 1000~26500 -0.41 -36.18 ≤-20.41 PASS 2462 Reference 0.32 0.32 --- PASS 30~1000 0.32 -28.19 ≤-19.68 PASS 1000~26500 0.32 -35.51 ≤-19.68 PASS 11N40SISO Ant1 2422 Reference -2.99 -2.99 --- PASS 30~1000 -2.99 -27.21 ≤-22.99 PASS 1000~26500 -2.99 -36.53 ≤-22.99 PASS 2437 Reference -3.45 -3.45 --- PASS 30~1000 -3.45 -27.24 ≤-23.45 PASS 1000~26500 -3.45 -36.16 ≤-23.45 PASS 2452 Reference -2.76 -2.76 --- PASS 30~1000 -2.76 -27.21 ≤-22.76 PASS 1000~26500 -2.76 -35.46 ≤-22.76 PASS Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 25 of 83 Test Graphs 11B_Ant1_2412_0~Reference 11B_Ant1_2412_30~1000 11B_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 26 of 83 11B_Ant1_2437_0~Reference 11B_Ant1_2437_30~1000 11B_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 27 of 83 11B_Ant1_2462_0~Reference 11B_Ant1_2462_30~1000 11B_Ant1_2462_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 28 of 83 11G_Ant1_2412_0~Reference 11G_Ant1_2412_30~1000 11G_Ant1_2412_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 29 of 83 11G_Ant1_2437_0~Reference 11G_Ant1_2437_30~1000 11G_Ant1_2437_1000~26500 Prüfbericht - Produkte Test Report - Products Appendix A CN26O08Z 002 Page 30 of 83 11G_Ant1_2462_0~Reference 11G_Ant1_2462_30~1000 11G_Ant1…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Andrew Posta
[email protected]Fax: 4409622000

Technical Contact

Moen IncorporatedAndrew Posta
[email protected]

25300 Al Moen Dr, North Olmsted · North Olmsted, Ohio · United States

Test Firm

TUV Rheinland (Shenzhen) Co., Ltd.Gina Yang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz155.20 mW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End user must be provided with transmitter operating conditions for satisfying RF exposure compliance. This device has 20/40MHz bandwidth modes.