Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Page 1 MeeXH COLLAR MAX User Manual 1. Product Overview The MeeXH COLLAR MAX is a state-of-the-art smart GPS/GNSS collar engineered to help enhance pet safety and provide real-time monitoring for pet owners. Designed to provide a portable, customizable alternative to traditional wired fences, this collar offers virtual boundaries that adapt to diverse environments, from urban apartments to rural properties. Leveraging advanced GPS/GNSS technology, the collar delivers location tracking, timely alerts, and humane feedback systems (sound, voice prompts, and vibration) to guide pets while supporting training. Suitable for daily use, outdoor adventures, and behavior training, this collar combines innovation, convenience, and pet-centric design for modern pet care. Important: This product is an aid to training and supervision. It is not a physical barrier and does not guarantee that your pet will remain within a designated area or prevent loss, injury, or property damage. You must supervise your pet and follow all applicable local laws at all times. Note: The collar provides feedback using sound, voice prompts, and vibration only. It does not deliver electric shocks or static corrections. 2. Important Safety Information & Limitations of Use Read all safety instructions before use. Failure to follow these instructions may result in injury to your pet, property damage, or reduced product performance. 2.1 Limitations of Use • This product is intended as an aid for pet training, location tracking, and virtual boundaries. • It does not guarantee the prevention of pet loss, injury, escape, or accidents. • GNSS location accuracy can be affected by buildings, trees, terrain, weather, indoor environments, and limited network coverage. Location information may sometimes be delayed, unavailable, or inaccurate. • The collar is not a physical fence, gate, or barrier and may not be suitable for all pets, properties, or local regulations. • This product is not recommended for aggressive dogs or pets with a history of repeated escaping or attacking. Consult a veterinarian or professional trainer if you are unsure. 2.2 Pet Health & Behavior • Consult your veterinarian before use if your pet has any medical conditions (such as heart disease, seizures, or skin sensitivities) or if your pet is very young, elderly, pregnant, or recovering from surgery. • Always introduce the collar and virtual fences gradually and use positive reinforcement. • Misuse of any training tool may cause stress or anxiety in pets. • If your pet shows signs of extreme or ongoing stress (trembling, excessive barking, avoidance behavior, refusal to move, persistent scratching at the collar), stop using the collar and consult a veterinarian or professional trainer. 2.3 Fitting and Skin Care Page 2 • Adjust the collar so it fits comfortably on your pet’s neck, leaving space for 2–3 fingers between the collar and your pet’s neck to avoid choking or skin irritation. Check the fit regularly, especially for growing puppies. • Remove the collar daily to inspect your pet’s neck for redness, irritation, sores, or hair loss. Clean both the collar and your pet’s neck area regularly to help prevent bacterial growth. • Discontinue use and consult a veterinarian if skin irritation persists. 2.4 Supervision and General Safety • Always supervise your pet when using the collar for the first time or in new environments. • Do not rely solely on the collar to prevent accidents—maintain visual contact with your pet when off-leash whenever possible. • The collar is not a substitute for proper pet supervision. In case of an emergency (e.g., your pet escapes and is in danger), contact local authorities or animal services immediately. • Follow all local leash laws and pet regulations even when virtual fences are active. 2.5 Water, Weather, and Environment • The collar is designed with an IP68 waterproof rating for typical outdoor use. • While the collar is waterproof, do not leave the collar on your pet during extended submersion (e.g., more than 30 minutes) unless specifically specified in the latest product specifications. • After saltwater exposure, rinse the collar with fresh water and dry it thoroughly. • Avoid using the collar in extreme weather (e.g., severe storms, extreme heat or cold), as it may affect performance or damage the device. 2.6 Children and Misuse • This product is intended to be installed, configured, and operated by adults. • Children should not install, operate, or charge the collar without adult supervision. • The collar and its accessories (e.g., chargers, cables, beacons) are not toys. Keep them out of reach of children to prevent choking hazards, ingestion, or electric shock. 2.7 Battery, Charging, and Disposal • Use only the included charging cable or manufacturer-approved accessories. • Do not attempt to open, disassemble, or replace the internal battery. There are no user- serviceable parts inside. • Do not charge the collar near flammable materials or in extreme temperatures (below 0 °C / 32 °F or above 45 °C / 113 °F). • Do not charge the device if it is wet. Ensure the charging port and contacts are dry before charging. • Charge the device on a dry, flat, non-flammable surface, away from bedding, paper, or other combustible materials. • Dispose of the collar’s battery in accordance with local regulations. Do not incinerate or puncture the battery as it may leak or explode. • If the device overheats, swells, leaks, emits an unusual smell, or behaves abnormally, stop using it immediately and contact MeeXH customer support. 3. Product Features Page 3 Virtual Fencing: Create customized virtual e-fences worldwide via the iPetLife mobile app. Fence information is stored in the collar for seamless offline use in many areas without cellular coverage. Real-Time Tracking & Alerts: Live GPS tracking provides continuous location updates for pets, and instant notifications for fence breaches and selected events (subject to network coverage and…
Text truncated - open the document above for the full version.
Meexh (Hangzhou) Tech Co., Ltd Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 2026/05/27 U.S. Agent Designation Meexh (Hangzhou) Tech Co., Ltd acknowledges their consent for the following contact located in the United States to act as their agent for service of process for the equipment for which authorization is sought (FCC ID: 2BVY9-MXH001): Name and company of U.S. agent: Bridgeport Advisory LLC Physical U.S. address of agent: 3330 W 38TH PL CHICAGO, IL 60632 United States FRN of U.S. agent: 0037566148 Phone of U.S. agent: (708) 680-6688 Email address of U.S. agent: [email protected] Bridgeport Advisory LLC acknowledges their obligation to accept service of process on behalf of Meexh (Hangzhou) Tech Co., Ltd with the FRN [0038394060] accepts its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. By signing this form, we confirm the above and that we are aware of the application requirements listed under § 2.911(d)(7). The information provided in this letter is based on the referenced rule parts of Title 47 of the CFR as well as KDB 986446 D01. An expiration date for this letter does not exist. In case the U.S. agent changes, the grantee is obligated to notify the FCC within 30 days via the granting TCB. An expiration date for this letter does not exist. Sincerely, Signature Shijie Zhang PM Meexh (Hangzhou) Tech Co., Ltd Signature Yong Liu Managing Member Bridgeport Advisory LLC 48_[mo del] US_Agent_2.911(d)(7) - U, V0 5
FCC ID: 2BVY9-MXH001 External Photos of the EUT FCC ID: 2BVY9-MXH001 FCC ID: 2BVY9-MXH001
Label and Location Size: L: 2.0cm*W: 1.0cm Label and Location FCC ID: 2BVY9-MXH001
FCC ID: 2BVY9-MXH001 Internal Photos of the EUT FCC ID: 2BVY9-MXH001 FCC ID:XMR2023EG800QNA FCC ID: 2BVY9-MXH001 FCC ID: 2BVY9-MXH001 BT Antenna FCC ID: 2BVY9-MXH001 LTE Antenna GPS RX Antenna
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn RF Exposure MPE Report Reference No. ..................... : FCC ID............................................. : CTA26051301208 2BVY9-MXH001 Compiled by ( position+printed name+signature) . : File administrators Zoey Cao Supervised by ( position+printed name+signature) . : Project Engineer Ace Chai Approved by ( position+printed name+signature) . : RF Manager Eric Wang Date of issue .................................... : May 18, 2026 Testing Laboratory Name .............. : Shenzhen CTA Testing Technology Co., Ltd. Address............................................ : Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : Meexh (Hangzhou) Tech Co., Ltd Address............................................ : Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China Standard ........................................... : 47CFR §1.1310 47CFR §2.1091 KDB447498 D01 General RF Exposure Guidance v06 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purpses as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description ..................... : MeeXH COLLAR MAX Trade Mark ....................................... : N/A Manufacturer .................................... : Meexh (Hangzhou) Tech Co., Ltd Model/Type reference ...................... : MXH001 Listed Models ................................... : N/A Rating ............................................... : Input: DC 5V Battery: 3.8V 1500mAh 5.7Wh Result ............................................... : PASS Report No.: CTA26051301208 Page 2 of 10 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : MeeXH COLLAR MAX Model /Type : MXH001 Listed Models : N/A Applicant : Meexh (Hangzhou) Tech Co., Ltd Address : Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China Manufacturer : Meexh (Hangzhou) Tech Co., Ltd Address : Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26051301208 Page 3 of 10 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ............................................................................................................ 4 2 SUMMARY .......................................................................................................................... 5 2.1 General Remarks ..................................................................................................... 5 2.2 Product Description ................................................................................................. 5 2.3 Special Accessories ................................................................................................. 6 2.4 Modifications ............................................................................................................ 6 3 TEST ENVIRONMENT ....................................................................................................... 7 3.1 Address of the test laboratory .................................................................................. 7 3.2 Test Facility .............................................................................................................. 7 3.3 Statement of the measurement uncertainty ............................................................. 7 4 Test limit .............................................................................................................................. 8 4.1 Requirement ............................................................................................................ 8 4.2 MPE Calculation Method ......................................................................................... 8 4.3 Conducted Power Results ....................................................................................... 8 4.4 Manufacturing tolerance .......................................................................................... 9 4.5 Standalone MPE Result ........................................................................................... 9 4.6 Simultaneous Transmission for MPE Result ......................................................... 10 5 Conclusion ......................................................................................................................... 10 Report No.: CTA26051301208 Page 4 of 10 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn 1 T E S T S T A N D A R…
Text truncated - open the document above for the full version.
1. Antenna Description: Antenna type Ceramic antenna Model MXH001 Frequency range 2400-2500MHz Manufacturer Meexh (Hangzhou) Tech Co., Ltd Address Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China ANT Peak Gain 1.36 dBi 2. Antenna Photo: 3. Test Equipment & Conditions 3.1 Test instrument VSWR is tested using Agilent E5071B connected to Length: 16.5mm Width: 3.29mm a hand mechanism, and the status is free space. 3.2 Test environment and methods 4.Antenna Radiation Pattern 2400MHz 2450MHz 2500MHz
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ...................: FCC ID. ......................................... : CTA26051301201 2BVY9-MXH001 Compiled by ( position+printed name+signature) : File administrators Zoey Cao Supervised by ( position+printed name+signature) : Project Engineer Ace Chai Approved by ( position+printed name+signature) : RF Manager Eric Wang Date of issue ...................................: May 18, 2026 Testing Laboratory Name .............: Shenzhen CTA Testing Technology Co., Ltd. Address ..........................................: Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name...........................: Meexh (Hangzhou) Tech Co., Ltd Address ...........................................: Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China Test specification ......................... : Standard ..........................................: FCC Part 15.247 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Equipment description ................ : MeeXH COLLAR MAX Trade Mark ......................................: N/A Manufacturer ...................................: Meexh (Hangzhou) Tech Co., Ltd Model/Type reference .....................: MXH001 Listed Models ..................................: N/A Modulation ......................................: GFSK Frequency .......................................: From 2402MHz to 2480MHz Ratings ............................................: Input: DC 5V Battery: 3.8V 1500mAh 5.7Wh Result ..............................................: PASS Report No.: CTA26051301201 Page 2 of 37 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn T E S T R E P O R T Equipment under Test : MeeXH COLLAR MAX Model /Type : MXH001 Listed Models : N/A Applicant : Meexh (Hangzhou) Tech Co., Ltd Address : Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China Manufacturer : Meexh (Hangzhou) Tech Co., Ltd Address : Room 1007, Building 7, Taihe Center 299 Pingshui Street Hangzhou, 310000 China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CTA26051301201 Page 3 of 37 Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao’an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:[email protected] Web:http://www.cta-test.cn Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5 2.1 General Remarks .............................................................................................................................. 5 2.2 Product Description* .......................................................................................................................... 5 2.3 Equipment Under Test ....................................................................................................................... 5 2.4 Short description of the Equipment under Test (EUT) ...................................................................... 5 2.5 EUT configuration .............................................................................................................................. 5 2.6 EUT operation mode ......................................................................................................................... 5 2.7 Block Diagram of Test Setup ............................................................................................................. 6 2.8 Related Submittal(s) / Grant (s) ......................................................................................................... 6 2.9 Modifications ...................................................................................................................................... 6 3 TEST ENVIRONMENT ................................................................................................................................. 7 3.1 Address of the test laboratory............................................................................................................ 7 3.2 Test Facility ....................................................................................................................................... 7 3.3 Environmental conditions .................................................................................................................. 7 3.4 Summary of measurement results .................................................................................................... 8 3.5 Statement of the measurement uncertainty .....…
Text truncated - open the document above for the full version.
1 FCC Appendix RF Test Data for BLE FCC ID : 2BVY9-MXH001 Company : Meexh (Hangzhou) Tech Co., Ltd EUT : MeeXH COLLAR MAX Model Number : MXH001 Report No. : CTA26051301201 Reviewed By : Eric Wang 2 Appendix A: DTS Bandwidth Test Result TestMode Antenna Freq(MHz) DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 0.644 2401.692 2402.336 0.5 PASS 2440 0.648 2439.692 2440.340 0.5 PASS 2480 0.692 2479.660 2480.352 0.5 PASS 3 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 4 5 Appendix B: Occupied Channel Bandwidth Test Result TestMode Antenna Freq(MHz) OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict BLE_1M Ant1 2402 1.0082 2401.5190 2402.5272 --- --- 2440 1.0003 2439.5176 2440.5179 --- --- 2480 1.0123 2479.5167 2480.5290 --- --- 6 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 7 8 Appendix C: Maximum conducted output power Test Result TestMode Antenna Freq(MHz) Conducted Peak Powert[dBm] Conducted Limit[dBm] Verdict BLE_1M Ant1 2402 -2.50 ≤30 PASS 2440 -2.57 ≤30 PASS 2480 -2.53 ≤30 PASS 9 Appendix D: Maximum power spectral density Test Result TestMode Antenna Freq(MHz) Result[dBm/3kHz] Limit[dBm/3kHz] Verdict BLE_1M Ant1 2402 -18.35 ≤8.00 PASS 2440 -18.38 ≤8.00 PASS 2480 -18.16 ≤8.00 PASS 10 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 11 12 Appendix E: Band edge measurements Test Result TestMod e Antenn a ChNam e Freq(MHz ) RefLevel[dBm ] Result[dBm ] Limit[dBm ] Verdic t BLE_1M Ant1 Low 2402 -3.40 -53.7 ≤-23.4 PASS High 2480 -2.91 -52.23 ≤-22.91 PASS 13 Test Graphs BLE_1M_Ant1_Low_2402 BLE_1M_Ant1_High_2480 14 Appendix F: Conducted Spurious Emission Test Result TestMode Antenna Freq(MHz) FreqRange [MHz] RefLevel [dBm] Result[dBm] Limit[dBm] Verdict BLE_1M Ant1 2402 Reference -3.15 -3.15 --- PASS 30~1000 -3.15 -67.26 ≤-23.15 PASS 1000~26500 -3.15 -43.64 ≤-23.15 PASS 2440 Reference -4.21 -4.21 --- PASS 30~1000 -4.21 -66.63 ≤-24.21 PASS 1000~26500 -4.21 -43.54 ≤-24.21 PASS 2480 Reference -3.90 -3.90 --- PASS 30~1000 -3.90 -67.56 ≤-23.9 PASS 1000~26500 -3.90 -46.83 ≤-23.9 PASS 15 Test Graphs BLE_1M_Ant1_2402_0~Reference BLE_1M_Ant1_2402_30~1000 BLE_1M_Ant1_2402_1000~26500 16 BLE_1M_Ant1_2440_0~Reference BLE_1M_Ant1_2440_30~1000 17 BLE_1M_Ant1_2440_1000~26500 BLE_1M_Ant1_2480_0~Reference BLE_1M_Ant1_2480_30~1000 18 BLE_1M_Ant1_2480_1000~26500 19 Appendix G: Duty Cycle Test Result TestMode Antenna Freq(MHz) ON Time [ms] Period [ms] X DC [%] xFactor Limit Verdict BLE_1M Ant1 2402 0.41 0.62 0.6613 66.13 1.80 --- --- 2440 0.41 0.62 0.6613 66.13 1.80 --- --- 2480 0.41 0.62 0.6613 66.13 1.80 --- --- 20 Test Graphs BLE_1M_Ant1_2402 BLE_1M_Ant1_2440 BLE_1M_Ant1_2480 21 22 Appendix H: Emissions in Restricted Bands Test Result TestMod e Antenn a ChNam e Freq(MH z) Detector Freq [MHz] Result [dBm] Gain [dB] DC Factor [dB] Result [dBuV/m] Limit [dBuV/m] Verdict BLE_1M Ant1 Low 2402 AV 2310.000 -59.99 2.00 1.80 39.01 ≤54 PASS AV 2386.940 -58.38 2.00 1.80 40.62 ≤54 PASS AV 2390.000 -59.21 2.00 1.80 39.79 ≤54 PASS Peak 2310.000 -53.28 2.00 0.00 43.92 ≤74 PASS Peak 2375.285 -47.71 2.00 0.00 49.49 ≤74 PASS Peak 2390.000 -50.22 2.00 0.00 46.98 ≤74 PASS High 2480 AV 2483.500 -57.68 2.00 1.80 41.32 ≤54 PASS AV 2483.760 -57.43 2.00 1.80 41.57 ≤54 PASS AV 2500.000 -58.76 2.00 1.80 40.24 ≤54 PASS Peak 2483.500 -49.09 2.00 0.00 48.11 ≤74 PASS Peak 2485.920 -47.11 2.00 0.00 50.09 ≤74 PASS Peak 2500.000 -50.74 2.00 0.00 46.46 ≤74 PASS Note: 1. The limit in dBm for average detector is conversion from 54dBuV/m, according to 15.209(a). The limit in dBm for peak detector is 20dB above the limit of average detector in dBm. 23 Test Graphs BLE_1M_Ant1_Low_2402_AV BLE_1M_Ant1_Low_2402_Peak BLE_1M_Ant1_High_2480_AV 24 BLE_1M_Ant1_High_2480_Peak
FCC ID: 2BVY9-MXH001 Test Setup Photos of the EUT FCC ID: 2BVY9-MXH001
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |