FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. I-Temp technology Company Limited/
  3. 2BVYD-TA101DB

2BVYD-TA101DBTable Display

I-Temp technology Company Limited
Table Display - FCC ID 2BVYD-TA101DB - I-Temp technology Company Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 27, 2026
Application Purpose
Original Equipment
Equipment Note
Table Display
Frequency Range
2412.00000000 - 2462.00000000
Company
I-Temp technology Company Limited
Country
China

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev1/26/2023 (I-TemptechnologyCompanyLimited) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-05-22 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2BVYD-TA101DB (“I-TemptechnologyCompanyLimited”)certifiesthattheequipmentforwhichauthorizationissoughtis not“covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection 2.903oftheFCCrules. (“I-TemptechnologyCompanyLimited”)certifiesthattheequipmentforwhichauthorizationissought doesnotincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.orany ofitssuccessorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):EchoHong Rev1/26/2023 (I-TemptechnologyCompanyLimited) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:2026-05-22 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2BVYD-TA101DB (“I-TemptechnologyCompanyLimited”)certifiesthat,asofthedateofthefilingoftheapplication,I- TemptechnologyCompanyLimitedisnotidentifiedontheCoveredList(asaspecificallynamedentityor anyofitssubsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature): (Applicantprintedname):EchoHong

Cover Letter(s)

I-TemptechnologyCompanyLimited Date:May22,2026 ProductModelNumber:TA101DB FCCID:2BVYD-TA101DB Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:Manager Email:[email protected] Telephone:+8613027941006 Onbehalfof:I-TemptechnologyCompanyLimited

Cover Letter(s)

I-TemptechnologyCompanyLimited OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:May25,2026 Subject;RequestforConfidentiality FCCID:2BVYD-TA101DB ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:EchoHong Title:Manager

External Photos

FCCID:2BVYD-TA101DB EUTPHOTOSExternalPhotos FCCID:2BVYD-TA101DB FCCID:2BVYD-TA101DB FCCID:2BVYD-TA101DB ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Size:20mmX30mm FCCID:2BVYD-TA101DB Thisdevicecomplieswithpart15oftheFCCRules. Operationissubjecttothefollowingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference,and (2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation.

RF Exposure Info

FCCID:2BVYD-TA101DB RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1091, UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. Limits Thecriterialistedinthefollowingtableshallbeusedtoevaluatetheenvironmentimpactof humanexposuretoradiofrequency(RF)radiationasspecifiedin1.1307(b) LimitsforMaximumPermissibleExposure(MPE) Frequency range (MHz) Electricfield strength (V/m) Magneticfield strength (A/m) Powerdensity (mW/cm 2 ) Averagingtime (minutes) (A)LimitsforOccupational/ControlledExposures 0.3–3.06141.63*(100)6 3.0–301842/f4.89/f*(900/f 2 )6 30–30061.40.1631.06 300–1500f/3006 1500–100,00056 (B)LimitsforGeneralPopulation/UncontrolledExposure 0.3–1.346141.63*(100)30 1.34–30824/f2.19/f*(180/f 2 )30 30–30027.50.0730.230 300–1500f/150030 1500–100,0001.030 f=frequencyinMHz Friistransmissionformula:Pd=(Pout*G)/(4*pi*r 2 ) Where Pd=powerdensityinmW/cm 2 ,Pout=outputpowertoantennainmW; G=gainofantennainlinearscale,Pi=3.1416; R=distancebetweenobservationpointandcenteroftheradiatorincm PdidthelimitofMPE,1mW/cm 2 .Ifweknowthemaximumgainoftheantennaandthe totalpowerinputtotheantenna,throughthecalculation,wewillknowthedistancerwhere theMPElimitisreached. TestProcedure SoftwareprovidedbyclientenabledtheEUTtotransmitandreceivedataatlowest,middle andhighestchannelindividually. TestResultofRFExposureEvaluation Mode Max.Output powerto antenna (dBm) Max.Output powerto antenna (mW) Max.Power Densityat R=20cm (mW/cm2) Limit (mW/cm2) Result BT 6.744.720.00161.0PASS 2.4GWIFI 21.93155.960.05311.0PASS 5.2GWIFI 11.4814.060.00401.0PASS Remark:5.2GWIFIAntennagain=1.29dBi,2.4GWIFIAntennagain=2.34dBi Conclusion:NoRFExposureEvaluationSARtestisrequired.

Test Report

ProjectNo.:ZHT-260421132W01-2 Page 1 of 85 ApplicantName...............:I-TemptechnologyCompanyLimited Address............................:Room701No.2Building,No.11GemdaleViseenIntelligentPark,Bao LongFirstRoad,LonggangDistrict,Shenzhen ManufacturerName.........:I-TemptechnologyCompanyLimited Address............................:Room701No.2Building,No.11GemdaleViseenIntelligentPark,Bao LongFirstRoad,LonggangDistrict,Shenzhen Product............................:TableDisplay Model(s)...........................:TA101DB AdditionalModel(s)..........:/ Trademark........................:Kritem,I-Temp,KRIZER ModelDifference..............:/ Preparedby......................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:Apr.21,2026 DateofTest(s)..................:May.1,2026toMay.9,2026 DateofIssue....................:May.9,2026 TestRequested................:Selecttest(s)asrequestedbytheclient. TestStandard(s)...............:FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure..................:KDB558074D0115.247MeasGuidancev05r02 ANSIC63.10-2020+Cor1-2023 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. FCCTESTREPORT FCCID:2BVYD-TA101DB ProjectNo.:ZHT-260421132W01-2 Page 2 of 85 TableofContents Page 1.SUMMARYOFTESTRESULTS................................................................................................................4 2.GENERALINFORMATION........................................................................................................................5 2.1GENERALDESCRIPTIONOFEUT..................................................................................................5 2.2DESCRIPTIONOFTESTMODES.....................................................................................................6 2.3BLOCKDIGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED................................7 2.4DESCRIPTIONOFSUPPORTUNITS(CONDUCTEDMODE).........................................................7 3.TESTFACILITYANDTESTINSTRUMENTUSED...................................................................................7 3.1TESTFACILITY..................................................................................................................................8 3.2EQUIPMENTSLISTFORALLTESTITEMS....................................................................................8 3.3TESTINGSOFTWARE.....................................................................................................................10 3.4MEASUREMENTUNCERTAINTY...................................................................................................10 4.EMCEMISSIONTEST.............................................................................................................................11 4.1CONDUCTEDEMISSIONMEASUREMENT...................................................................................11 4.2RADIATEDEMISSIONMEASUREMENT.......................................................................................15 5.RADIATEDBANDEMISSIONMEASUREMENT.....................................................................................22 5.1TESTREQUIREMENT:....................................................................................................................22 5.2TESTPROCEDURE.........................................................................................................................22 5.3DEVIATIONFROMTESTSTANDARD...........................................................................................22 5.4TESTSETUP....................................................................................................................................23 5.5EUTOPERATINGCONDITIONS.....................................................................................................23 5.6TESTRESULT..................................................................................................................................24 6.POWERSPECTRALDENSITYTEST.....................................................................................................26 6.1APPLIEDPROCEDURES/LIMIT...................................................................................................26 6.2TESTPROCEDURE.........................................................................................................................26 6.3DEVIATIONFROMSTANDARD......................................................................................................26 6.4TESTSETUP....................................................................................................................................26 6.5EUTOPERATIONCONDITIONS.....................................................................................................26 6.6TESTRESULT..................................................................................................................................27 7.CHANNELBANDWIDTH.........................................................................................................................28 7.1APPLIEDPROCEDURES/LIMIT...................................................................................................28 7.2TESTPROCEDURE.........................................................................................................................28 7.3DEVIATIONFROMSTANDARD......................................................................................................28 7.4TESTSETUP.......................................................…

Text truncated - open the document above for the full version.

Test Report

TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City Ltd. 客户 : 悟腾/Wuteng 品 名 规 格 DESCRIPTION: EDP-1.13-L200-IPEXGeneration 1 料 PART 号 NO.: 客 户 料 号 CUS PART NO.: 日期 D A T E : 2025-7-2 云顶呈样签章 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 业务 SALESDEPARTMENT 客户承认签章 工程 ENGINEERINGDEPARTMENT 品保 QCDEPARTMENT 采购 PURCHASINGDEPARTMENT 承認 TEL:0755 23073599 ж The acknowledgement form is in three copies. Our company, Huimeng, hereby affirms and signs. ж Approval in duplicate, please signed by your company. 書 APPROVALSHEET SHENZHEN 天线 Antenna type: FPC Antenna TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 1. 测试项目与设备/Testing items and equipment 测试项目/Testing items 1.S11参数 (S-parameter 设备/Equipment ) 1.回波损耗(ReturnLoss) 2.电压驻波比(VSWR)HP8753 Network Analyzer: Agilent E5071B D 2.有源测试 (Active) 1.发射功率(TRP) 2.接收灵敏度(TIS) 1.Darkroom:ETS 7x4x3 m (3D) Chamber StarPointSP6011Cmw50 ETS 5x3x3 m (3D) Chamber 2. Comprehensive tester: Agilent 8960 E5515B ×2 0 3.无源测试 (Passive) 1.天线增益(Gain)2.天线效 率(Efficiency) 1.Darkroom:ETS 7x4x3 m (3D) Chamber HP8753 ETS 5x3x3 m (3D) Chamber 2.Network analyzer:Agilent E5071B D 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 2. 天线性能/Antenna performance SWR 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 3. 天线效率与增益/Antenna efficiency and gain PassiveTestForWIFI FreqEffiGain (MHz)(%)(dBi) 240052.681.71 241052.051.76 242050.391.71 243052.71.92 244055.752.13 245060.312.34 246061.162.26 247061.662.17 248062.542.13 249063.72.15 250064.072.23 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N PassiveTestForWIFI5.8 FreqEffiGain (MHz)(%)(dBi) 515057.651.29 520052.360.76 525046.790.16 530049.360.4 535058.051.13 540065.741.8 545058.961.53 550060.611.74 555063.452.28 560060.142.21 565056.982.02 570056.921.78 575059.282.02 580054.711.05 585047.40.66 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 4. 天线结构图/Antenna structure diagram: 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City Unit: mm TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 电器技术参数/Electrical technical parameters 电 性 能 指 标/ ElectricalSpecifications 频率范围2400~2500/5150~5850HzFrequencyRange2400~2500/5150~5850Hz 电压驻波比≤2.0VSWR≤2.0 输入阻抗50ΩInputImpedance50Ω 增益Gai2.34dBi Maxn2.34dBi Max 机械指标 MechanicalSpecifications 线材颜色黑色WirecolorBlack 接口形式IPEX一代InputconnectorIPEX1 天线线长200mmCablelength200mm 工作温度-40°C~+85°CWorkingTemperature-40°C~+85°C 工作湿度20~80%WorkingHumidity20~80% 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City TEL:+860755-23073599FAX:+860755-23097189E-mail:[email protected] SHENZHE 深圳市云顶通讯电子有限公司 Shenzhen Yunding Communication Electronics Co., Ltd. N 环境性能测试( Environmentperformancetest ) : 项目测试条件测试结果 储存环境 在没有指定的情况下测试温度、湿度、气压如下: 1.温度为-30°C~+80°C 2.相对湿度为45%-85% 3.气压为86kpa-106kpa 电气机械性能正常 高低温试验 在70°C与-40°C之间进行5次循环,然后在正常条件下 1-2H,检查外观质量。 尺寸应满足规定并应 满足 于机械、电气性能 耐恒定湿热 试验 相对湿度95±3%,试验温度:40°C.持续2H作用后, 试品取出后5min之内测定电气性能,试品在正常条 件下1-2H,检查外观质量 尺寸应满足规定并应 满足 于机械、电气性能 振动试验 振频范围10-55HZ,位移幅值:0.35MM,加速度幅值: 50.0M/S,扫频循环次数:30次 电气机械性能正常 跌落试验1M高空按照互相垂直的轴方向自由跌落3次电气机械性能正常 ProjectTestconditionTestresults Storage environment Testtemperature,humidity,pressurewithout statedconditionasfollwings:1.Temperature:-30°C~ +80°C;2.Relativehumidity:45%-85%;3,Pressure: 86kpa-106kpa Electricaland mechanical performancenormal Highandlow temperaturetest Having5timescyclebetween-40°Cto70°C,Thenincommon condition1-2hourstestexteriorquality. Measurement satisfiedwith electricaland mechanical performancenormal. Resistance constanthotand humidtest Relativehumidity:95±3%,Testtemperature:40°C,last2 hours,putitafter5mintesttheelectricalfunction.Test productsduringcommoncondition1-2hours,Thentest exteriorquality. Measurement satisfiedwith electricaland mechanical performancenormal. Vibrationtest VibrateFrequency:10-55HZ; Distance:0.35mm;Acceleration:50.0m/s;Sweepfrequency cycle:30times Electricaland mechanical performancenormal FalltestFrom1mheightfalldown3timesfreely(verticaldirection) Electricaland mechanical performancenormal 地址:深圳市宝安区航空路锦驰中心 3015 Address: Room 3015, Jinchi Center, Aviation Road, Bao'an District, Shenzhen City

Test Setup Photos

FCCID:2BVYD-TA101DB EUTTESTPHOTOS FCCID:2BVYD-TA101DB ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

Echo Hong
[email protected]Fax: +8613027941006

Technical Contact

BERDAM LLCLeonardo Lei
[email protected]

110 16TH ST STE 1400 DENVER CO, · United States

Test Firm

Guangdong Zhonghan Testing Technology Co., Ltd.Alex Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz156.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. The antennas used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.