FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. POC SWEDEN AB/
  3. 2BVYI-OBEXCOM

2BVYI-OBEXCOMOBEX CONTOUR COMMUNICATION

POC SWEDEN AB
OBEX CONTOUR COMMUNICATION - FCC ID 2BVYI-OBEXCOM - POC SWEDEN AB
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Sep 09, 2026
Application Purpose
Original Equipment
Equipment Note
OBEX CONTOUR COMMUNICATION
Frequency Range
2402.00000000 - 2480.00000000
Company
POC SWEDEN AB
Country
Sweden

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Rev 1/26/2023 POC SWEDEN AB Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2026-8-11 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCCID:2BVYI-OBEXCOM [POC SWEDEN AB] (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. [POC SWEDEN AB] (“the applicant”) certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Device is inherently compliant based on hardware limitations or software controls. or A Software Bill of Materials (SBOM) is provided to the TCB for review, and The end-user or third parties cannot install additional software on this device. Sincerely, (Applicant signature) (Applicant printed name)Johan Weman Rev 1/26/2023 (POC SWEDEN AB) Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date:2026.8.11 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID:2BVYI-OBEXCOM [POC SWEDEN AB] (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (Applicant signature) (Applicant printed name)Johan Weman

Attestation Statements

* the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. SC6075239 U.S. Agent Designation for Service of Process - Certification Attestation Letter 8/3/2026 TO: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 ATTN.: Reviewing Engineer FCC ID: 2BVYI-OBEXCOM FRN of applicant: 0038385753 Per section 2.911(d)(7) of the FCC rules, POC SWEDEN AB FRN:0038385753(“the applicant”) certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: Global Product Services and Consultation LLC FCC Registration Number (FRN): 0033406703 Physical U.S. Company Address: 328 W Palm Ave. Monrovia, CA91016 Contact Person: Michael Chan Tel: +1 626 366 4358 Agent Email Address: [email protected] The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Agent Signed (if different from Applicant): Signed: Printed name: Johan Weman Title: Project Manager Company Name: POC SWEDEN AB Date: 8/3/2026 Signed: Printed name: Michael Chan Title: Technical Director Company Name: Global Product Services and Consultation LLC Date: 8/3/2026

Cover Letter(s)

POC SWEDEN AB Date:2026.8.12 Product Model Number: FCCID:2BVYI-OBEXCOM To whom it may concern, Re: Product Certification Representative Authorization Letter We authorize QAI Laboratories Ltd. 3980 North Fraser Way, Burnaby B.C. Canada V5J 5K5 to act on our behalf on all matters concerning the above named equipment. This shall include the following: • Testing • Approval applications and procedures We declare that QAI Laboratories Ltd. is allowed to forward all information related to the approval project to the applied certification body and to the notification entities and to discuss any issues concerning the approval application. Any and all acts carried out by QAI Laboratories Ltd. on our behalf shall have the same effect as acts of our own. By: Contact Listed on FCC Wesbite Title: Project Manager Email: [email protected] Telephone: 0046703852310 On behalf of: POC SWEDEN AB

Cover Letter(s)

POC SWEDEN AB Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: September 4, 2026 Subject; Request for Confidentiality FCCID:2BVYI-OBEXCOM To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure Software Security Requirements for UNII devices In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name:Johan Weman Title:Project Manager

External Photos

Model:OBEXCOMMUNICATIONHEADSET

Internal Photos

Model:OBEXCOMMUNICATIONHEADSET

RF Exposure Info

Page: 1/10 Ref : ACR.78.6.26.PAR.B Cancel and replace the report ACR.78.6.26.PAR.A WALTEK TESTING GROUP (SHENZHEN) CO., LTD 1/F., ROOM 101, BUILDING 1, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD, BLOCK 70 BAO'AN DISTRICT, SHENZHEN, GUANGDONG, 518101 CHINA MVG COMOSAR DOSIMETRIC E-FIELD PROBE SERIAL NO.: 0725-EPGO-446 Calibrated at MVG 13 Rue du Zephyr 91140 Villejust - FRANCE Calibration date: 03/03/2026 Scope available on :https://a2la.org/ Summary: This document presents the method and results from an accredited COMOSAR Dosimetric E-Field Probe calibration performed at MVG, using the CALIPROBE test bench, for use with a MVG COMO SAR system only. The test results covered by accreditation are traceable to the International System of Units (SI). COMOSAR E-Field Probe Calibration Report            COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.78.6.26.PAR.B Page: 2/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. Name Function Date Signature Prepared by : Pedro Ruiz Technical Manager 3/18/2026 Checked & approved by: Pedro Ruiz Technical Manager 3/18/2026 Authorized by: Christophe Barrot Quality Manager Customer Name Distribution : WALTEK TESTING GROUP (SHENZHEN) CO., LTD Issue Name Date Modifications A Pedro Ruiz 3/18/2026 Initial release B Pedro Ruiz 04/10/2026 Update customer address              COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.78.6.26.PAR.B Page: 3/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. TABLE OF CONTENTS 1 Device Under Test ..................................................................................................... 4 2 Product Description ................................................................................................... 4 2.1 General Information _______________________________________________________ 4 3 Measurement Method ................................................................................................ 4 3.1 Sensitivity _______________________________________________________________ 4 3.2 Linearity ________________________________________________________________ 4 3.3 Isotropy _________________________________________________________________ 5 3.4 Boundary Effect __________________________________________________________ 5 3.5 Probe Modulation Response _________________________________________________ 5 4 Measurement Uncertainty .......................................................................................... 6 5 Calibration Results ..................................................................................................... 6 5.1 Calibration in air __________________________________________________________ 6 5.2 Calibration in liquid _______________________________________________________ 7 6 Verification Results ................................................................................................... 8 7 List of Equipment ...................................................................................................... 9            COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.78.6.26.PAR.B Page: 4/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or part without written approval of MVG. 1 DEVICE UNDER TEST Device Under Test Device Type COMOSAR DOSIMETRIC E FIELD PROBE Manufacturer MVG Model SSE2 Serial Number 0725-EPGO-446 Product Condition (new / used) Used Frequency Range of Probe 0.15 GHz-7.5GHz Resistance of Three Dipoles at Connector Dipole 1: R1=0.248 M: Dipole 2: R2= 0.216 M: Dipole 3: R3=0.231 M: 2 PRODUCT DESCRIPTION 2.1 GENERAL INFORMATION MVG’s COMOSAR E field Probes are built in accordance to the IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards. Figure 1 – MVG COMOSAR Dosimetric E field Probe Probe Length 330 mm Length of Individual Dipoles 2 mm Maximum external diameter 8 mm Probe Tip External Diameter 2.5 mm Distance between dipoles / probe extremity 1 mm 3 MEASUREMENT METHOD The IEC/IEEE 62209-1528 and FCC KDB865664 D01 standards provide recommended practices for the probe calibrations, including the performance characteristics of interest and methods by which to assess their effect. All calibrations / measurements performed meet the fore-mentioned standards. 3.1 SENSITIVITY The sensitivity factors of the three dipoles were determined using a two step calibration method (air and tissue simulating liquid) using waveguides as outlined in the standards for frequency range 600- 7500MHz and using the calorimeter cell method (transfer method) as outlined in the standards for frequency 150-450 MHz. 3.2 LINEARITY The evaluation of the linearity was done in free space using the waveguide, performing a power sweep to cover the SAR range 0.01W/kg to 100W/kg.            COMOSAR E-FIELD PROBE CALIBRATION REPORT Ref: ACR.78.6.26.PAR.B Page: 5/10 Template_ACR.DDD.N.YY.MVGB.ISSUE_COMOSAR Probe vN This document shall not be reproduced, except in full or in part, without the written approval of MVG. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released…

Text truncated - open the document above for the full version.

RF Exposure Info

Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 1 of 39 TEST REPORT Reference No. .................... : WTX26X05135697W FCC ID ................................ : 2BVYI-OBEXCOM Applicant ........................... : POC SWEDEN AB Address.............................. : Nackagatan 4,11649 Stockholm, Sweden Manufacturer ..................... Guoguang Electric Co., Ltd Address.............................. No.8 Jinghu Road, Xinya Street, Huadu Reg, Guangzhou, Guangdong, P.R.China Product Name ................... : OBEX CONTOUR COMMUNICATION Model No.. .......................... : OBEX COMMUNICATION HEADSET Standards .......................... : FCC Part 2.1093, IEEE Std C95.1: 2019 IEEE C95.3: 2021 IEC/IEEE 62209-1528:2020 Date of Receipt sample .... : 2026-05-18 Date of Test........................ : 2026-05-19 to 2026-06-12 Date of Issue ..................... : 2026-06-12 Test Report Form No. ....... : WTX_Part2_1093W Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of approver. Prepared By: Waltek Testing Group (Shenzhen) Co., Ltd. Address: 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao'an District, Shenzhen, Guangdong, China Tel.: +86-755-33663308 Fax.: +86-755-33663309 Email: [email protected] Tested by: Approved by: Lily Yang /Project Engineer Jason Su/Manager Reference No.: WTX26X05135697W Waltek Testing Group (Shenzhen) Co., Ltd. Http://www.waltek.com.cn Page 2 of 39 TABLE OF CONTENTS 1. General Information ...................................................................................................................................................4 1.1 Product Description for Equipment Under Test (EUT) .........................................................................................4 1.2 Test Standards ....................................................................................................................................................5 1.3 Test Methodology ................................................................................................................................................5 1.4 Test Facility .........................................................................................................................................................5 2. Summary of Test Results ..........................................................................................................................................6 3. Specific Absorption Rate (SAR) ................................................................................................................................7 3.1 Introduction ..........................................................................................................................................................7 3.2 SAR Definition .....................................................................................................................................................7 4. SAR Measurement System ........................................................................................................................................8 4.1 The Measurement System ..................................................................................................................................8 4.2 Probe ...................................................................................................................................................................8 4.3 Probe Calibration Process ................................................................................................................................. 10 4.4 Phantom ............................................................................................................................................................ 10 4.5 Device Holder .................................................................................................................................................... 11 4.6 Test Equipment List ........................................................................................................................................... 12 5. Tissue Simulating Liquids ....................................................................................................................................... 13 5.1 Composition of Tissue Simulating Liquid ........................................................................................................... 13 5.2 Tissue Dielectric Parameters for Head and Body Phantoms ............................................................................. 14 5.3 Tissue Calibration Result ................................................................................................................................... 15 6. SAR Measurement Evaluation ................................................................................................................................ 16 6.1 Purpose of System Performance Check ............................................................................................................ 16 6.2 System Setup .................................................................................................................................................... 16 6.3 Validation Results .............................................................................................................................................. 17 7. EUT Testing Position ............................................................................................................................................... 18 7.1 Body Position .................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Website:www.cblueasia.com Tel:+86-755-23059481 Email:[email protected] ThetestreportiseffectiveonlywithbothsignatureandspecializedstampandTheresult(s)showninthisreportreferonlytothesample(s)tested.Without writtenapprovalofBlueAsia,thisreportcan ’ tbereproducedexceptinfull.Theresultsdescribedinthisreportdonotrepresentthequalityorcharacteristicsofthe sampledbatch,nordotheyrepresentanysimilaroridenticalproductsthatarenotexplicitlystated. TestReport Applicant:POCSWEDENAB Address:Nackagatan4,11649Stockholm,Sweden ProductName:OBEXCONTOURCOMMUNICATION BrandMark:N/A Model:OBEXCOMMUNICATIONHEADSET Seriesmodel:N/A ReportNumber:BLA-EMC-202604-A94-02 FCCID:2BVYI-OBEXCOM DateofReceipt:Apr.22,2026 DateofTest:Apr.27,2026toAug.27,2026 TestStandard: 47CFRPart15,SubpartC15.247 TestResult:Pass Compiledby:Reviewby:Approvedby: IssuedDate:Aug.28,2026 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Address: No.41,SouthofBeihuanRoad,ShangwuCommunity,Shiyan Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China ReportNo.:BLA-EMC-202604-A94-02 Page 2 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 TableofContents 1Generalinformation................................................................................................................................................5 1.1Generalinformation..........................................................................................................................................5 1.2GeneraldescriptionofEUT..............................................................................................................................5 2Testsummary..........................................................................................................................................................6 3TestConfiguration..................................................................................................................................................7 3.1Testmode.........................................................................................................................................................7 3.2OperationFrequencyeachofchannel.............................................................................................................8 3.3Testchannel.....................................................................................................................................................8 3.4ConfigurationdiagramofEUT..........................................................................................................................9 3.5Auxiliaryequipment........................................................................................................................................10 3.6Testenvironment............................................................................................................................................10 4Laboratoryinformation.........................................................................................................................................11 4.1Laboratoryandaccreditations........................................................................................................................11 4.2Measurementuncertainty...............................................................................................................................11 5Testequipment......................................................................................................................................................13 6Testresult..............................................................................................................................................................17 6.1Antennarequirement......................................................................................................................................17 6.2ConductedemissionsatACpowerline(150kHz-30MHz)...........................................................................18 6.3ConductedpeakoutputPower.......................................................................................................................22 6.420dBBandwidth.............................................................................................................................................24 6.5ConductedBandEdgesMeasurement..........................................................................................................26 6.6Conductedspuriousemissions......................................................................................................................28 6.7CarrierFrequenciesSeparation.....................................................................................................................30 6.8HoppingChannelNumber..............................................................................................................................32 6.9DwellTime......................................................................................................................................................34 6.10Radiatedspuriousemissions.........................................................................................................................36 6.11Radiatedemissionswhichfallintherestrictedbands...................................................................................48 7AppendixA............................................................................................................................................................55 7.1MaximumPKConductedOutputPower........................................................................................................55 7.2-20dBBandwidth............................................................................................................................................60 ReportNo.:BLA-EMC-202604-A94-02 Page 3 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:marketing@cb…

Text truncated - open the document above for the full version.

Test Report

ReportNo.:BLA-EMC-202604-A94-02 Page 46 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 [Testmode:TXHighchannel];[Polarity:Vertical];[Power:DC3.8V] TestResult:Pass Note:Whenscanningintherangeof1GHz~25GHzandtheinterferenceabove18GHzisverysmall,itisalownoisesignal.The pointshowninthefigureaboveisthehighestemissionthatcanbefoundduringthetest,soonlytheabovepointisshown.The fundamentalfrequencyisblockedbythefilter.Onlystrayemission. DH1,DH3,DH5allhavebeentested,duringthetest,GFSK,pi/4DQPSK,8DPSK,modulationwereallpre-scannedOnlythe (DH1/GFSK)oftheworstmodewouldberecordedinthisreport. ReportNo.:BLA-EMC-202604-A94-02 Page 47 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 ReportNo.:BLA-EMC-202604-A94-02 Page 48 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 6.11Radiatedemissionswhichfallintherestrictedbands TestStandard 47CFRPart15,SubpartC15.247(d) 47CFRPart15,SubpartC15.205 TestMethod ANSI C63.10-2020+Cor.1-2023+C63.10a-2024+ErratatoC63.10a-2024 Clause6.10.5 TestMode(Pre-Scan)TX TestMode(FinalTest)TX 6.11.1Limit Frequency(MHz) Field strength(microvolts/meter) Measurement distance(meters) 0.009-0.4902400/F(kHz)300 0.490-1.70524000/F(kHz)30 1.705-30.03030 30-881003 88-2161503 216-9602003 Above9605003 Remark:TheemissionlimitsshownintheabovetablearebasedonmeasurementsemployingaCISPR quasi-peakdetectorexceptforthefrequencybands9-90kHz,110-490kHzandabove1000MHz.Radiated emissionlimitsinthesethreebandsarebasedonmeasurementsemployinganaveragedetector,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation. ReportNo.:BLA-EMC-202604-A94-02 Page 49 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 6.11.2Testsetup Below1GHz: 30MHz-1GHz: Above1GHz: ReportNo.:BLA-EMC-202604-A94-02 Page 50 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 6.11.3Procedure a)Forbelow1GHz,theEUTwasplacedonthetopofarotatingtable0.8metersabovethegroundat a3or10metersemi-anechoicchamber.Thetablewasrotated360degreestodeterminethe positionofthehighestradiation. b)Forabove1GHz,theEUTwasplacedonthetopofarotatingtable1.5metersabovethegroundat a3meterfully-anechoicchamber.Thetablewasrotated360degreestodeterminethepositionof thehighestradiation. c)TheEUTwasset3or10metersawayfromtheinterference-receivingantenna,whichwasmounted onthetopofavariable-heightantennatower. d)Theantennaheightisvariedfromonemetertofourmetersabovethegroundtodeterminethe maximumvalueofthefieldstrength.Bothhorizontalandverticalpolarizationsoftheantennaare settomakethemeasurement. e)Foreachsuspectedemission,theEUTwasarrangedtoitsworstcaseandthentheantennawas tunedtoheightsfrom1meterto4meters(forthetestfrequencyofbelow30MHz,theantennawas tunedtoheights1meter)andtherotatabletablewasturnedfrom0degreesto360degreestofind themaximumreading. f)Thetest-receiversystemwassettoPeakDetectFunctionandSpecifiedBandwidthwithMaximum HoldMode. g)IftheemissionleveloftheEUTinpeakmodewas10dBlowerthanthelimitspecified,thentesting couldbestoppedandthepeakvaluesoftheEUTwouldbereported.Otherwisetheemissionsthat didnothave10dBmarginwouldbere-testedonebyoneusingpeak,quasi-peakoraverage methodasspecifiedandthenreportedinadatasheet. h)TesttheEUTinthelowestchannel,themiddlechannel,thehighestchannel. i)TheradiationmeasurementsareperformedinX,Y,ZaxispositioningforTransmittingmode,and foundtheXaxispositioningwhichitistheworstcase. j)Repeataboveproceduresuntilallfrequenciesmeasuredwascomplete. Note1:Level(dBuV)=Reading(dBuV)+Factor(dB/m) Note2:Forfrequenciesabove1GHz,thefieldstrengthlimitsarebasedonaveragelimits.However,thepeakfield strengthofanyemissionshallnotexceedthemaximumpermittedaveragelimitsspecifiedabovebymorethan20 dBunderanyconditionofmodulation.Fortheemissionswhosepeaklevelislowerthantheaveragelimit,only thepeakmeasurementisshowninthereport. ReportNo.:BLA-EMC-202604-A94-02 Page 51 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 6.11.4Testdata [Testmode:TXlowchannel];[Polarity:Horizontal];[Power:DC3.8V] TestResult:Pass ReportNo.:BLA-EMC-202604-A94-02 Page 52 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 [Testmode:TXlowchannel];[Polarity:Vertical];[Power:DC3.8V] TestResult:Pass ReportNo.:BLA-EMC-202604-A94-02 Page 53 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 [Testmode:TXHighchannel];[Polarity:Horizontal];[Power:DC3.8V] TestResult:Pass ReportNo.:BLA-EMC-202604-A94-02 Page 54 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 [Testmode:TXHighchannel];[Polarity:Vertical];[Power:DC3.8V] TestResult:Pass DH1,DH3,DH5allhavebeentested,duringthetest,GFSK,pi/4DQPSK,8DPSK,modulationwereallpre-scannedOnlythe (DH1/GFSK)oftheworstmodewouldberecordedinthisreport. ReportNo.:BLA-EMC-202604-A94-02 Page 55 of 110 BlueAsiaTechnicalServices(Shenzhen)Co.,Ltd Tel:+86-755-23059481 Email:[email protected]:V1.2 7AppendixA 7.1MaximumPKConductedOutputPower ConditionModeFrequency(MHz)AntennaConductedPower(dBm)Limit(dBm)Verdict NVNT1-DH12402Ant13.49521Pass NVNT1-DH12441Ant13.60121Pass NVNT1-DH12480Ant13.90621Pass NVNT2-DH12402Ant15.83521Pass NVNT2-DH12441Ant15.95221Pass NVNT2-DH12480Ant16.24921Pass NVNT3-DH1240…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Johan Weman
[email protected]Fax: 0046703852310

Technical Contact

Global Product Services and Consultation LLCMichael Chan
[email protected]

328 W Palm Ave. Monrovia, CA91016 · China

Test Firm

BLUEASIA TECHNICAL SERVICES (SHENZHEN) CO., LTD.Blue Zheng
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz4.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory is 0.15W/kg.