FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. CHUNJITEK CO., Ltd/
  3. 2BW2XSMC-V1

2BW2XSMC-V1CONTROLLER-SMART KEY

CHUNJITEK CO., Ltd

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Aug 14, 2026
Application Purpose
Original Equipment
Equipment Note
CONTROLLER-SMART KEY
Frequency Range
0.12500000 - 0.12500000
Company
CHUNJITEK CO., Ltd
Country
South Korea

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

CHUNJITEK CO., Ltd Attestation Statement Letter I Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 22/Jul/2026 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC Application for FCC ID: 2BW2XSMC-V1 CHUNJITEK CO., Ltd certifies that the equipment for which authorization is sought is not “covered” equipment prohibited for receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, Applicant’s Signature: Applicant’s Name: Ji-Hoon, Kim

Attestation Statements

CHUNJITEK CO., Ltd Attestation Statement Letter II Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 22/Jul/2026 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC Application for FCC ID: 2BW2XSMC-V1 CHUNJITEK CO., Ltd certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, Applicant’s Signature: Applicant’s Name: Ji-Hoon, Kim

Cover Letter(s)

Date: 04/17/2018 VCB_F-01: Operating Procedures Form – FCC Authorization v02 Page 1 of 1 CHUNJITEK CO., Ltd Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 22/Jul/2026 SUBJECT: FCC Application for (FCC ID: 2BW2XSMC-V1) To Whom It May Concern: We, the undersigned, hereby authorize Eun-Hye, Kwak in ICR Co., Ltd. on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by ICR Co., Ltd. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, (Must be signed by the person that is listed on the FCC Website) Client’s signature: Client’s name & title: Ji-Hoon, Kim & Manager Contact information / address: +82-10-5767-7220 & 18, Gajeong-ro 38beon-gil, Seo-gu, Incheon, South Korea

Cover Letter(s)

Date: 04/17/2018 VCB_F-01: Operating Procedures Form – FCC Confidentiality v03 Page 1 of 1 CHUNJITEK CO., Ltd Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2BW2XSMC-V1 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Type of Confidentiality Requested Exhibit Type ☐Short Term ☒Permanent Block Diagrams ☒Short Term External Photos ☒Short Term ☐Permanent* Internal Photos ☐Short Term ☒Permanent Operation Description ☐Short Term ☒Permanent Parts List/BOM ☐Short Term ☒Permanent Schematics ☒Short Term Test Setup Photos ☒Short Term ☐Permanent* User manual *Requires further justification before permanent confidentiality will be allowed. The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below for an initial period of 180 days. Sincerely, Client’s signature: Client’s name & title: Ji-Hoon, Kim & Manager Contact information / address: +82-10-5767-7220 & 18, Gajeong-ro 38beon-gil, Seo-gu, Incheon, South Korea

Cover Letter(s)

CHUNJITEK CO., Ltd 18, Gajeong-ro 38beon-gil, Seo-gu, Incheon, South Korea Date: 22/Jul/2026 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2BW2XSMC-V1 US Agent – Attestation Statement / Part 2.911(d)(7) CHUNJITEK CO., Ltd certifies, that as of 22/Jul/2026, we have designated LOS ANGELES LANERS, INC. to accept service of process on our behalf for FCC ID: 2BW2XSMC-V1. CHUNJITEK CO., Ltd, accepts to maintain an agent of service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission related administrative or judicial proceeding involving the equipment, whichever is later. LOS ANGELES LANERS, INC., accepts as of the date of the filing of this application, the obligation of being the designated agent for the purpose of accepting service of process on behalf of CHUNJITEK CO., Ltd for FCC ID: 2BW2XSMC-V1. Designated Agent Information: Company Name: LOS ANGELES LANERS, INC. FRN: 0038012399 Address: 3141 Michelson Dr Unit 1503, Irvine CA 92612 Contact Person: Bali Bai Phone: 949-988-0609 Email: [email protected] Sincerely, Company: CHUNJITEK CO., Ltd Designated Agent: Bali Bai Company Representative: Ji-Hoon, Kim Designated Agent Representative: Signature: Signature:

ID Label/Location Info

CONTROLLER-SMART KEY (SMC-V1) KC Certificate R-R-cJt-SMC-V1 (주)천지테크 CHUNJITEK CO., Ltd. MADE IN KOREA FCC ID : 2BW2XSMC-V1 IC : 35907-SMC-V1

RF Exposure Info

1.Regulation RF Exposure FCC rule part 1.1310(d) (1) Evaluation with respect to the SAR limits in this section must demonstrate compliance with both the whole-body and peak spatial-average limits using technically supported measurement or computational methods and exposure conditions in advance of authorization (licensing or equipment certification) and in a manner that facilitates independent assessment and, if appropriate, enforcement. Numerical computation of SAR must be supported by adequate documentation showing that the numerical method as implemented in the computational software has been fully validated; in addition, the equipment under test and exposure conditions must be modeled according to protocols established by FCC-accepted numerical computation standards or available FCC procedures for the specific computational method. (2) For operations within the frequency range of 300 kHz and 6 GHz (inclusive), the limits for maximum permissible exposure (MPE), derived from whole-body SAR limits and listed in Table 1 in paragraph (e)(1) of this section, may be used instead of whole-body SAR limits as set forth in paragraphs (a) through (c) of this section to evaluate the environmental impact of human exposure to RF radiation as specified in § 1.1307(b) of this part, except for portable devices as defined in § 2.1093 of this chapter as these evaluations shall be performed according to the SAR provisions in § 2.1093. 2.Evaluation Method OET Bulletin 65 Section 2: PREDICTION METHODS_Equations for Predicting RF Fields S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) EIRP = equivalent (or effective) isotropically radiated power 1 / 3 3.Limit Table 1 to § 1.1310(e)(1)—Limits for Maximum Permissible Exposure (MPE) 2 / 3 ± 1.0 Power density at 20 ㎝ [mW/cm 2 ] 0.000 14 Notes. 1. Power density(S) = 10^((Max Tune-up Power + Ant Gain )/10) / (4 x π x R 2 ) 2. Since the EUT employs an integral antenna and the EIRP was derived from the measured radiated field strength of the complete device, no additional antenna gain was applied. 3. E-Field level is 92.66 dBuV/m at 3m, EIRP [dBm] = E-Field [dBuV/m] - 95.2 EIRP [dBm] -2.54 Ant Gain [dBi] Limit [mW/cm 2 ] 125-1.0 4.Result Frequency [kHz] Tolerance [dBm] 3 / 3

Test Report

page : (2) / Total (14) 14 5. Used equipment 2. Equipment under Test(EUT) Information Contents 5 6 7 3. Test Summary 4. Test Result 1. Applicant & Manufacturer & Test Laboratory Information 4 ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (2) / Total (14) ICRT-TR-E262235-0A2026.07.21 Revision History Issued Report No.Issued DateRevisionsEffect Section Initial IssueAll ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (2) / Total (14) +82-2-6351-9002Telephone No. 0.58% ICR Co., Ltd. +82-2-6351-9007 KT652 KR0165 KOLAS No. KC & FCC Occupied Channel Bandwidth RF output power, conducted 1.95 dB Fax No. 1.4 Measurement Uncertainty 1. Applicant & Manufacturer & Test Laboratory Information ±6 dB Time All emissions, radiated (Range 30 MHz ~ 1 GHz) Address Laboratory ParameterUncertaintyLimit 0.14%±5 % 0.85 dB±1.5 dB 1.44 dB±3 dB Applicant 1.1 Applicant information 1.2 Manufacturer Information 1.3 Test Laboratory Information Applicant All emissions, radiated (Under the 30 MHz)±6 dB2.10 dB 1.35 dB ±3 dB 0.02%±3 %Supply voltages Power Spectral Density, conducted Unwanted Emissions, conducted ±5 % Address CHUNJITEK CO., Ltd 18, Gajeong-ro 38beon-gil, Seo-gu, Incheon, South Korea (youngchang technotown 1-9) CHUNJITEK CO., Ltd 18, Gajeong-ro 38beon-gil, Seo-gu, Incheon, South Korea (youngchang technotown 1-9) Address 112, Hwanggeum 3-ro 7beon-gil, Hagun-ri, Yangchon-eup, Gimpo-si, Gyeonggi-do, Korea ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (3) / Total (14) FCC ID2BW2XSMC-V1 ISED certification number 35907-SMC-V1 Tx : 125 kHz, Rx : 433.92 MHz - The EUT is continuous transmission mode during the test. Stand-alone DCD - Part 15 Low Power Transmitter Below 1705 kHz Operating Frequency Equipment Class Device Type Modulation TypeASK 2.3 Mode of operation during the test Product Name Model Name Additional Model Name Power SupplyDC 12.0 V - SMC-V1 CONTROLLER-SMART KEY 2. Equipment under Test(EUT) Information 2.1 General Information 2.2 Additional Information ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (4) / Total (14) PASS 3.1 Test standards and results ※The X-, Y-, and Z-axis orientations were compared, and the X-axis orientation was selected for testing because it exhibited the highest output level. FCC Part 15 Subpart C & RSS-Gen & RSS-210 RSS-Gen 8.9 RSS-210 8.2, 8.3 Applied ■ ResultsRSS Clause PASS Test itemsFCC Part Clause §15.209 (a) RSS-Gen 8.8 ■ PASS AC power-line conducted emissions limits §15.207 (a) Radiated Spurious Emission -RSS-Gen 6.799 % Bandwidth ■ 3. Test Summary 3.3 Test Methodology - Both conducted and radiated testing was performed according to the procedures in ANSI C63.10-2020. Radiated testing was performed at a distance of 3 m from EUT to the antenna. 3.4 Configuration of Test System - To determine whether the equipment under test fulfills the requirements of the standards stated in FCC Part 15 Subpart C Section 15.209 & RSS-Gen 3.2 Purpose of the test - Both conducted and radiated testing was performed according to the procedures in ANSI C63.10-2020. Radiated testing was performed at a distance of 3 m from EUT to the antenna. 3.4.1 Radiated emission test - Preliminary radiated emissions test were conducted using the procedure in ANSI C63.10-2020 to determine the worse operating conditions. Final radiated emission tests were conducted at 3 m Semi Anechoic Chamber. The turntable was rotated through 360 degrees and the EUT was tested by positioned three orthogonal planes to obtain the highest reading on the field strength meter. Once maximum reading was determined, the search antenna was raised and lowered in both vertical and horizontal polarization. ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (2) / Total (14) - 4. Test Result 99% Bandwidth Measured Value (kHz) 9.23 Result : Pass Frequency (kHz) Limit (kHz) 125- 4.1 99 % Bandwidth 4.1.1 Test procedure ANSI C63.10-2020 6.9.3 & RSS-Gen 6.7 4.1.2 Limit 4.1.3 Test data ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (3) / Total (14) ANSI C63.10-2020 Clause 6.4, 6.5, 6.6 RSS-Gen 8.9 & RSS-210 8.2, 8.3 4.2.1 Test procedure 4.2.2 Limit 4.2 Radiated Spurious Emission According to §15.209(a), for an intentional device, the general requirement of field strength of radiated emissions from intentional radiators at a distance of 3 meters shall not exceed the following values: ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (4) / Total (14) ※ Limit =at 0.009-0.490MHz and 3m distance, 20log(2400/F(kHz)) + 40log(300m/3m) ※ Limit =at 0.490-1.705MHz and 3m distance, 20log(24000/F(kHz)) + 40log(30m/3m) 1.47828.03QPH19.9047.9364.2116.28- 0.61924.73QPV19.9044.6371.7827.15- 19.9058.6196.2237.61- Factor (dB) Result (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) note 0.37138.71QPH 4.2.3 Test data Result : Pass - Below 30 MHz Frequency (MHz) Reading (dBuV/m) DetectorPol. 0.12472.76QPH19.9092.66105.7613.10- 0.10937.16QPH19.9057.06106.8949.83- 0.15040.37QPH19.9060.27104.0843.81- 4.2.4 Measured Graph ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (5) / Total (14) 163.18152.83QPH-19.3033.5343.529.99 127.58251.61QPH-19.30 27.3740.0012.63- 41.64049.90QPV-15.3034.6040.005.40- 31.64945.87QPV-18.50 40.008.73- 41.05849.89QPV-15.3034.5940.005.41- 32.3143.5211.21- Frequency (MHz) Reading (dBuV/m) DetectorPol. Factor (dB) Result (dBuV/m) Limit (dBuV/m) Margin (dBuV/m) note 36.11148.17QPV-16.9031.27 Result : Pass - 30 MHz ~ 1 GHz - 4.2.6 Measured Graph 4.2.5 Test data ICRT-QPA-17-03 Rev.2 Report No. ICRT-TR-E262235-0A page : (6) / Total (14) 4.3 Power Line Conducted Emission 4.3.1 Test procedure ANSI C63.10-2020 Clause 6.2 & RSS-Gen 8.8 4.3.2 Limit §15.207 (a) Except as shown in paragraphs (b) and (c) of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed the limits in t…

Text truncated - open the document above for the full version.

Test Report

RFID物联网发射模块C款-6.8*16*80mm Emitter Antenna6.8*16*80mmHousing plastic base-potted and outside connector unsealed or sealed 山东省威海市高区文化西路190-1银丰大厦B1310,电话: 13563182375,18769198975,0631-5682375,[email protected] The antenna C is designed for emission of a LF field to allow hands free access towards the Customer Device Identification for automotive application. This type antenna are inserted in the vehicle being integrated into the Access and Start Hand Free subsystem for requirements Passive Entry and Remote keyless Go System. Housing plastic base Polyamide (ABS optional) assuring extreme conditions of humidity, liquids, substance and extreme environments. The connector is optional and it can be customized to required features. It can be sealed or unsealed with 2P, 3P,...,6P male or female and located outside the assembly of the antenna with 2 cables type SCA 105ºC. Inside of the housing plastic base the serial inductance, capacitance and resistance can be customized to required values. Designed to allow long emitting-reading distances in the smallest volume. Variety of mounting requirements and solutions which to incorporate features to accommodate different fastening anchors and mechanical robustness.Nomenclature description: Name L (mH)Frequency(khz) Length (mm) Width (mm) Height (mm) standard C-0500J0.512580166.8 IPX 6 Dimensions The specification chart is a reference guide for the most common required values at working frequencies of 125 kHz, 20 kHz and 134.2 kHz. Any other inductance value at LF or tighter tolerances can be provided. Please contact our sales deparment for any inquiry. Electrical diagram

Contact Information

Applicant

Ji-Hoon KIM
[email protected]Fax: 82-10-5767-7220

Technical Contact

LOS ANGELES LANERS, INC.Bali BAI
[email protected]

3141 Michelson Dr Unit 1503 · Irvine, California · United States

Test Firm

ICR Co., Ltd.Sim Sang-Woo
[email protected]Fax: +82-2-6351-9007

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term